DIGIPDU-MIB
AI MIB Summary
The DIGIPDU-MIB module provides SNMP-based monitoring and management capabilities for Schneider Electric's Digital Power Distribution Units (PDUs), exposing granular metrics including voltage, current, power consumption, temperature, and relay status for each outlet. This MIB enables centralized telemetry collection for power infrastructure health, load balancing, and environmental threshold alerting within data center environments.
This is the MIB module for the All DIGIPDU Device
Main OID:
smart.1.3.6.1.4.1.10456.3
233
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
233 total| Object Name |
|---|
digipdu OBJECT IDENTIFIER .1.3.6.1.4.1.10456 |
smartThis is the MIB module for the All DIGIPDU Device MODULE-IDENTITY .1.3.6.1.4.1.10456.3 |
product OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.1 |
productModelIndicate the Model of Device.ro DisplayString .1.3.6.1.4.1.10456.3.1.1 |
productPartNumberThe part number of this appliance as shown on the label.ro DisplayString .1.3.6.1.4.1.10456.3.1.2 |
productSerialNumberThe serial number of this appliance as shown on the label.ro DisplayString .1.3.6.1.4.1.10456.3.1.3 |
productFirmwareVersionThe version of the firmware of this product.ro DisplayString .1.3.6.1.4.1.10456.3.1.4 |
productTemperatureKindTemperature Kind(0:CELSIUS, 1:FAHRENHEIT).ro INTEGER .1.3.6.1.4.1.10456.3.1.11 |
productResetDetectorDisplay the Nearest Operated Time of Reset Buttom.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.1.21 |
deviceTable OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.2 |
deviceATSKindDevice ATS Kind.ro INTEGER .1.3.6.1.4.1.10456.3.2.1 |
deviceInFeedTotalInput Feed Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.2 |
deviceInFeedKindInput Feed Kind.ro INTEGER .1.3.6.1.4.1.10456.3.2.3 |
deviceInFeedBranchInput Feed Kind.ro INTEGER .1.3.6.1.4.1.10456.3.2.4 |
deviceOutTotalOut Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.5 |
deviceOutKindOut Kind.ro INTEGER .1.3.6.1.4.1.10456.3.2.6 |
deviceInbuiltTempTotalInbuilt Temperature Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.7 |
deviceExtendTemperatureTotalExtend ENV Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.8 |
deviceExtendRHTotalExtend ENV Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.9 |
devicePDUTotalPDU Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.10 |
deviceInputTotalInput Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.11 |
deviceUPSUPS.ro Enumeration .1.3.6.1.4.1.10456.3.2.12 |
deviceDaisyChainDaisy Chain.ro Enumeration .1.3.6.1.4.1.10456.3.2.13 |
deviceUnitTotalDevice Unit Total.ro INTEGER .1.3.6.1.4.1.10456.3.2.20 |
deviceUnitTableThe table of Device Unit. SEQUENCE OF DeviceUnitEntry .1.3.6.1.4.1.10456.3.2.21 |
deviceUnitEntryRow definition for Device Unit table. DeviceUnitEntry .1.3.6.1.4.1.10456.3.2.21.1 |
deviceUnitIndexDevice Unit table index.ro INTEGER .1.3.6.1.4.1.10456.3.2.21.1.1 |
deviceUnitStatusstatus in the Device Unit.ro INTEGER .1.3.6.1.4.1.10456.3.2.21.1.2 |
deviceUnitInfeedTotalInfeed Total of Device Unit.ro INTEGER .1.3.6.1.4.1.10456.3.2.21.1.3 |
deviceUnitOutTotalOut Total of Device Unit.ro INTEGER .1.3.6.1.4.1.10456.3.2.21.1.4 |
peripheralTables OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.3 |
aTSTableThe table of Auto Transfer Switch. SEQUENCE OF ATSEntry .1.3.6.1.4.1.10456.3.3.1 |
aTSEntryRow definition for Input Feed table. ATSEntry .1.3.6.1.4.1.10456.3.3.1.1 |
aTSIndexAuto Transfer Switch table index.ro INTEGER .1.3.6.1.4.1.10456.3.3.1.1.1 |
aTSStatusstatus in the Auto Transfer Switch.ro INTEGER .1.3.6.1.4.1.10456.3.3.1.1.2 |
aTSVoltageVoltage of Auto Transfer Switch.ro INTEGER .1.3.6.1.4.1.10456.3.3.1.1.3 |
aTSFrequencyFrequency of Auto Transfer Switch.ro INTEGER .1.3.6.1.4.1.10456.3.3.1.1.4 |
inFeedTableThe table of Input Feed. SEQUENCE OF InFeedEntry .1.3.6.1.4.1.10456.3.3.2 |
inFeedEntryRow definition for Input Feed table. InFeedEntry .1.3.6.1.4.1.10456.3.3.2.1 |
inFeedIndexInput Feed table index.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.1 |
inFeedStatusstatus in the Input Feed.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.2 |
inFeedVoltageVoltage of Input Feed.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.3 |
inFeedFrequencyFrequency of Input Feed.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.4 |
inFeedCurrentTotal Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.5 |
inFeedPowerLoadActual value of power in the Input Feed.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.6 |
inFeedPowerFactorActual value of power factor in the Input Feed.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.7 |
inFeedPowerEnergyActual value of energy in the Input Feed.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.8 |
inFeedOverLoadOverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.9 |
inFeedHighWarningHigh Warning of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.10 |
inFeedLowWarningLow Warning of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.11 |
inFeedBranchAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.12 |
inFeedBranch1CurrentAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.13 |
inFeedBranch1PowerLoadActual value of power in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.14 |
inFeedBranch1PowerFactorActual value of power factor in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.15 |
inFeedBranch1OverLoadOverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.16 |
inFeedBranch1HighWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.17 |
inFeedBranch1LowWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.18 |
inFeedBranch2CurrentAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.19 |
inFeedBranch2PowerLoadActual value of power in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.20 |
inFeedBranch2PowerFactorActual value of power factor in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.2.1.21 |
inFeedBranch2OverLoadOverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.22 |
inFeedBranch2HighWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.23 |
inFeedBranch2LowWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.2.1.24 |
outTableThe table of Outlet. SEQUENCE OF OutletEntry .1.3.6.1.4.1.10456.3.3.3 |
outEntryRow definition for Outlet table. OutletEntry .1.3.6.1.4.1.10456.3.3.3.1 |
outIndexOut table index.ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.1 |
outComputerStatusOut computer status.ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.2 |
outCurrentStatusOut Current status.ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.3 |
outSwitchStatusThis OID is provided for Outlet Status information. '0' if the out is Switch Off. '1' if the out is Switch On. '2' if the out is Switch Off Acting. '3' if the out is Switch On Acting.ro Enumeration .1.3.6.1.4.1.10456.3.3.3.1.4 |
outSwitchCtrlThis OID is provided for Outlet Status information. '0' if the out is None. '1' Switch Ctrl On. '2' Switch Ctrl Off. '3' Switch Ctrl Reboot. '4' Switch Ctrl On Off.rw Enumeration .1.3.6.1.4.1.10456.3.3.3.1.5 |
outVoltageVoltage of Outlet.ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.6 |
outCurrentCurrent of Outlet(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.7 |
outPowerFactorActual value of power factor in the Outlet.ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.8 |
outPowerLoadActual value of power in the Outlet.ro INTEGER .1.3.6.1.4.1.10456.3.3.3.1.9 |
outOverloadOverload of Outlet(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.3.1.10 |
outHighWarningHigh Warning of Outlet(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.3.1.11 |
outLowWarningLow Warning of Outlet(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.3.1.12 |
pduTablesThe table of PDU. SEQUENCE OF PDUEntry .1.3.6.1.4.1.10456.3.3.4 |
pduEntryRow definition for PDU table. PDUEntry .1.3.6.1.4.1.10456.3.3.4.1 |
pduIndexPDU table index.ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.1 |
pduModelNow Power Data Log of PDU(In tenths of amps, divide by 10 for value in amps).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.4.1.2 |
pduMonitorPDU Monitor Status.rw Enumeration .1.3.6.1.4.1.10456.3.3.4.1.3 |
pduStatusPDU Connect Status.ro Enumeration .1.3.6.1.4.1.10456.3.3.4.1.4 |
pduVoltageVoltage of PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.5 |
pduFrequencyFrequency of PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.6 |
pduCurrentTotal Current of PDU(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.7 |
pduPowerLoadActual value of power in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.8 |
pduPowerFactorActual value of power factor in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.9 |
pduPowerEnergyActual value of power in the PDU.ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.10 |
pduOverloadOverload of PDU(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.11 |
pduHighWarningHigh Warning of PDU(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.12 |
pduLowWarningHigh Warning of PDU(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.13 |
pduBranchAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.14 |
pduBranch1CurrentAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.15 |
pduBranch1OverloadOverload of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.16 |
pduBranch1HighWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.17 |
pduBranch1LowWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.18 |
pduBranch2CurrentAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).ro INTEGER .1.3.6.1.4.1.10456.3.3.4.1.19 |
pduBranch2OverloadOverload of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.20 |
pduBranch2HighWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.21 |
pduBranch2LowWarningAverage Current of Input Feed(In tenths of amps, divide by 10 for value in amps).rw INTEGER .1.3.6.1.4.1.10456.3.3.4.1.22 |
inbuiltTemperatureTableThe table of Inbuilt Temperature Sensor. SEQUENCE OF InbuiltTemperatureEntry .1.3.6.1.4.1.10456.3.3.5 |
inbuiltTemperatureEntryRow definition for Inbuilt Temperature Sensor table. InbuiltTemperatureEntry .1.3.6.1.4.1.10456.3.3.5.1 |
inbuiltTemperatureIndexIndex for the Inbuilt Temperature Sensor table.ro INTEGER .1.3.6.1.4.1.10456.3.3.5.1.1 |
inbuiltTemperatureStatusInbuilt Temperature Sensor Connect Status.ro Enumeration .1.3.6.1.4.1.10456.3.3.5.1.2 |
inbuiltTemperatureDetected Temperature from Inbuilt Temperature Sensor.ro INTEGER .1.3.6.1.4.1.10456.3.3.5.1.3 |
inbuiltTemperatureHighWarningHigh Warning Temperature from Inbuilt Temperature Sensor.rw INTEGER .1.3.6.1.4.1.10456.3.3.5.1.4 |
inbuiltTemperatureLowWarningLow Warning Temperature from Inbuilt Temperature Sensor.rw INTEGER .1.3.6.1.4.1.10456.3.3.5.1.5 |
extendTemperatureTableThe table of Extend Temperature Sensor. SEQUENCE OF ExtendTemperatureEntry .1.3.6.1.4.1.10456.3.3.6 |
extendTemperatureEntryRow definition for Extend Temperature Sensor table. ExtendTemperatureEntry .1.3.6.1.4.1.10456.3.3.6.1 |
extendTemperatureIndexIndex for the Extend Temperature Sensor table.ro INTEGER .1.3.6.1.4.1.10456.3.3.6.1.1 |
extendTemperatureDeviceIdExtend Temperature Monitor Status.ro INTEGER .1.3.6.1.4.1.10456.3.3.6.1.2 |
extendTemperaturePortExtend Temperature Monitor Status.ro INTEGER .1.3.6.1.4.1.10456.3.3.6.1.3 |
extendTemperatureMonitorExtend Temperature Monitor Status.ro Enumeration .1.3.6.1.4.1.10456.3.3.6.1.4 |
extendTemperatureStatusExtend Temperature Sensor Connect Status.ro Enumeration .1.3.6.1.4.1.10456.3.3.6.1.5 |
extendTemperatureDetected Temperature from Inbuilt Temperature Sensor.ro INTEGER .1.3.6.1.4.1.10456.3.3.6.1.6 |
extendTemperatureHighWarningHigh Warning Temperature from Extend Temperature Sensor.rw INTEGER .1.3.6.1.4.1.10456.3.3.6.1.7 |
extendTemperatureLowWarningLow Warning Temperature from Extend Temperature Sensor.rw INTEGER .1.3.6.1.4.1.10456.3.3.6.1.8 |
extendRHTableThe table of Extend RH Sensor. SEQUENCE OF ExtendRHEntry .1.3.6.1.4.1.10456.3.3.7 |
extendRHEntryRow definition for Extend RH table. ExtendRHEntry .1.3.6.1.4.1.10456.3.3.7.1 |
extendRHIndexIndex for the Extend RH Sensor table.ro INTEGER .1.3.6.1.4.1.10456.3.3.7.1.1 |
extendRHDeviceIdIndex for the Extend RH Sensor table.ro INTEGER .1.3.6.1.4.1.10456.3.3.7.1.2 |
extendRHPortIndex for the Extend RH Sensor table.ro INTEGER .1.3.6.1.4.1.10456.3.3.7.1.3 |
extendRHMonitorExtend RH Monitor Status.ro Enumeration .1.3.6.1.4.1.10456.3.3.7.1.4 |
extendRHStatusExtend RH Sensor Connect Status.ro Enumeration .1.3.6.1.4.1.10456.3.3.7.1.5 |
extendRHDetected RH from Inbuilt Temperature Sensor.ro INTEGER .1.3.6.1.4.1.10456.3.3.7.1.6 |
extendRHHighWarningHigh Warning RH from Extend Temperature Sensor.rw INTEGER .1.3.6.1.4.1.10456.3.3.7.1.7 |
extendRHLowWarningLow Warning RH from Extend Temperature Sensor.rw INTEGER .1.3.6.1.4.1.10456.3.3.7.1.8 |
inputTableThe table of Input. SEQUENCE OF InputEntry .1.3.6.1.4.1.10456.3.3.8 |
inputEntryRow definition for Input table. InputEntry .1.3.6.1.4.1.10456.3.3.8.1 |
inputIndexIndex for Input table.ro INTEGER (1) .1.3.6.1.4.1.10456.3.3.8.1.1 |
inputStatusThis OID is provided for Input Status. '0' NORMAL. '1' WARNING. '2' TIMEOUT.ro INTEGER .1.3.6.1.4.1.10456.3.3.8.1.2 |
inputStateThis OID is provided for Input Default. '0' NORMAL_CLOSE. '1' NORMAL_OPEN.rw INTEGER .1.3.6.1.4.1.10456.3.3.8.1.3 |
inputTimeoutTimeOut of Input Status.rw INTEGER .1.3.6.1.4.1.10456.3.3.8.1.4 |
inputDefaultThis OID is provided for Input Default. '0' NORMAL_CLOSE. '1' NORMAL_OPEN.rw INTEGER .1.3.6.1.4.1.10456.3.3.8.1.5 |
inputDetectTimeDetect the nearest Changed Time of Input Status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.8.1.6 |
rfidReader OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.3.9 |
rfidCardNumRFID Card Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.9.1 |
rfidDetectTimeThe Nearest Time to detect RFID Card.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.9.2 |
uPS OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.3.10 |
uPSModelUPS Model.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.10.1 |
uPSConnectStatusUPS Connect Status.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.2 |
uPSFirmwareUPS Firmware.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.10.3 |
uPSSerialUPS Serial.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.10.4 |
uPSTemperatureUPS Temperature.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.5 |
uPSInputVoltageUPS Input Voltage.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.6 |
uPSOutputOnBatteryUPS Output On Battery.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.7 |
uPSOutputVoltageUPS Output Voltage.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.8 |
uPSOutputFrequencyUPS Output Voltage.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.9 |
uPSOutputCurrentUPS Output Current.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.10 |
uPSOutputLoadUPS Output Load.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.11 |
uPSOutputOverloadUPS Output Overload.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.12 |
uPSBatteryDateUPS Battery Date.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.10.13 |
uPSBatteryVoltageUPS Battery Voltage.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.14 |
uPSBatteryLevelUPS Battery Level.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.15 |
uPSBatteryRunTimeUPS Battery RunTime.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.16 |
uPSBatteryLowUPS Battery Low.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.17 |
uPSBatteryReplaceUPS Battery Need Replace.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.18 |
uPSUARTIdUPS UART Id.ro INTEGER .1.3.6.1.4.1.10456.3.3.10.19 |
micDetec OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.3.11 |
micDetectTimesMIC Detect Times.ro INTEGER .1.3.6.1.4.1.10456.3.3.11.1 |
micDetectPeriodMIC Detect Period.ro INTEGER .1.3.6.1.4.1.10456.3.3.11.2 |
micLastDetectTimeMIC Detect Detect Time.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.11.3 |
vibrationDetec OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.3.12 |
vibrationDetectTimesVibration Detect Times.ro INTEGER .1.3.6.1.4.1.10456.3.3.12.1 |
vibrationDetectPeriodVibration Detect Period.ro INTEGER .1.3.6.1.4.1.10456.3.3.12.2 |
vibrationLastDetectTimeVibration Detect Detect Time.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.3.12.3 |
dataLogTable OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.4 |
inFeedDataListInput Feed Data List.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.4.1 |
outDataListOutlet Data List.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.4.2 |
pduDataListPDU Data List.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10456.3.4.3 |
smartTraps OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.100 |
trap OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.100.1 |
testTraptestData NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.1 |
inFeedOverloadTrapdeviceIndex, inFeedIndex, inFeedStatus, inFeedCurrent, inFeedOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.101 |
inFeedHighCurrentTrapdeviceIndex, inFeedIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.102 |
inFeedLowCurrentTrapdeviceIndex, inFeedIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.103 |
inFeedBranchOverloadTrapinFeedIndex, BranchIndex, inFeedStatus, inFeedCurrent, inFeedOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.104 |
inFeedBranchHighCurrentTrapinFeedIndex, BranchIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.105 |
inFeedBranchLowCurrentTrapinFeedIndex, BranchIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.106 |
outWebOperationTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.201 |
outPanelOperationTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.202 |
outAPIOperationTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.203 |
outScheduleTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.211 |
outScheduleErrorTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.212 |
outPingTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.221 |
outPingRebootTrapOutlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.222 |
outOverloadTrapdeviceIndex, outIndex, outCurrentStatus, outCurrent, outHighWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.231 |
outHighCurrentTrapdeviceIndex, outIndex, outCurrentStatus, outCurrent, outHighWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.232 |
outLowCurrentTrapdeviceIndex, outIndex, outCurrentStatus, outCurrent, outLowWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.233 |
outConditionCtrlTrapdeviceIndex, outIndex, outCurrentStatus, outCurrent, outLowWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.241 |
outUPSACFaultOffTrapdeviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.311 |
outUPSBatteryLevelOffTrapdeviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.312 |
outUPSBatteryLowOffTrapdeviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.313 |
outUPSACRecoveryOnTrapdeviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.314 |
outUPSBatteryLevelOnTrapdeviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.315 |
outUPSBatteryLowRecoveryOnTrapdeviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.316 |
pduConnectTrapPDUIndex, PDUConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.401 |
pduOverloadTrapdeviceIndex, PDUIndex, PDUStatus, PDUCurrent, PDUOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.402 |
pduHighCurrentTrapdeviceIndex, PDUIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.403 |
pduLowCurrentTrapdeviceIndex, PDUIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.404 |
pduBranchOverloadTrapPDUIndex, BranchIndex, PDUStatus, PDUCurrent, PDUOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.405 |
pduBranchHighCurrentTrapPDUIndex, BranchIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.406 |
pduBranchLowCurrentTrapPDUIndex, BranchIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.407 |
inbuiltTemperatureHighTrapInTempId, InTempStatus, InTempTemperature, InTempTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.501 |
inbuiltTemperatureLowTrapInTempId, InTempStatus, InTempTemperature, InTempTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.502 |
envConnectTrapdeviceIndex, ENVIndex, ENVConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.511 |
envTemperatureConnectTrapdeviceIndex, ENVIndex, ENVConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.512 |
envTemperatureHighTrapdeviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.513 |
envTemperatureLowTrapdeviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.514 |
envRHConnectTrapdeviceIndex, EnvId, EnvStatus, EnvRH, EnvRHWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.515 |
envRHHighTrapdeviceIndex, EnvId, EnvStatus, EnvRH, EnvRHWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.516 |
envRHLowTrapdeviceIndex, EnvId, EnvStatus, EnvRH, EnvRHWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.517 |
inputTimeOutTrapdeviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.601 |
inputTrapdeviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.602 |
upsConnectTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.701 |
upsOnBatteryTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.702 |
upsOverloadTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.703 |
upsBatteryLowTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.704 |
upsBatteryReplaceModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.705 |
daisyChainConnectTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.801 |
micDetectOccurTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.901 |
vibrationDetectOccurTrapModel, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated. NOTIFICATION-TYPE .1.3.6.1.4.1.10456.3.100.1.902 |
arg OBJECT IDENTIFIER .1.3.6.1.4.1.10456.3.100.2 |
trapArg1Indicate the Trap Arg1.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.1 |
trapArg2Indicate the Trap Arg2.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.2 |
trapArg3Indicate the Trap Arg3.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.3 |
trapArg4Indicate the Trap Arg4.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.4 |
trapArg5Indicate the Trap Arg5.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.5 |
trapArg6Indicate the Trap Arg6.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.6 |
trapArg7Indicate the Trap Arg7.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.7 |
trapArg8Indicate the Trap Arg8.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.8 |
trapArg9Indicate the Trap Arg9.ro INTEGER .1.3.6.1.4.1.10456.3.100.2.9 |