DATA-DOMAIN-MIB
AI MIB Summary
The DATA-DOMAIN-MIB enables SNMP-based monitoring and management of Dell EMC Data Domain storage appliances, exposing critical metrics for capacity utilization, deduplication ratios, replication status, and system health. It provides granular visibility into storage pool states, disk array performance, and backup job statistics to facilitate proactive infrastructure maintenance.
This MIB is used for managing the suite of Data Domain Products.
Main OID:
dataDomainMib.1.3.6.1.4.1.19746
1192
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
1192 total| Object Name |
|---|
dataDomainMibThis MIB is used for managing the suite of Data Domain Products. MODULE-IDENTITY .1.3.6.1.4.1.19746 |
dataDomainMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.19746.0 |
dataDomainMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.19746.0.1 |
dataDomainMibComplianceThe compliance statement for SNMP entities which implement this MIB module.deprecated Unknown .1.3.6.1.4.1.19746.0.1.1 |
dataDomainMibComplianceRev1The compliance statement for SNMP entities which implement this MIB module.deprecated Unknown .1.3.6.1.4.1.19746.0.1.2 |
dataDomainMibComplianceRev2The compliance statement for SNMP entities which implement this MIB module.deprecated Unknown .1.3.6.1.4.1.19746.0.1.3 |
dataDomainMibComplianceRev3The compliance statement for SNMP entities which implement this MIB module.deprecated Unknown .1.3.6.1.4.1.19746.0.1.4 |
dataDomainMibComplianceRev4The compliance statement for SNMP entities which implement this MIB module.deprecated Unknown .1.3.6.1.4.1.19746.0.1.5 |
dataDomainMibComplianceRev5The compliance statement for SNMP entities which implement this MIB module. Unknown .1.3.6.1.4.1.19746.0.1.6 |
dataDomainMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.19746.0.2 |
environmentalsGroupA collection of objects providing environmental monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.1 |
nvramGroupA collection of objects providing nvram monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.2 |
fileSystemGroupA collection of objects providing file system monitoring information.deprecated Unknown .1.3.6.1.4.1.19746.0.2.3 |
alertsGroupA collection of objects providing alert monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.4 |
statisticsGroupA collection of objects providing statistics information. Unknown .1.3.6.1.4.1.19746.0.2.5 |
internalDiskStorageGroupA collection of objects providing internal disk monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.7 |
externalUnmanagedDiskStorageGroupA collection of objects providing external unmanaged disk monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.8 |
basicNotificationsGroupA collection of objects providing basic notifications.deprecated Unknown .1.3.6.1.4.1.19746.0.2.9 |
internalDiskStorageNotificationsGroupA collection of objects providing internal disk storage notifications.deprecated Unknown .1.3.6.1.4.1.19746.0.2.10 |
replGroupa collection of objects providing replication pair config and monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.11 |
nfsGroupA collection of objects providing NFS monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.12 |
cifsGroupA collection of objects providing CIFS monitoring information.deprecated Unknown .1.3.6.1.4.1.19746.0.2.13 |
vtlGroupA collection of objects providing VTL monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.14 |
ddboostGroupA collection of objects providing DDBoost monitoring information.deprecated Unknown .1.3.6.1.4.1.19746.0.2.15 |
ddsystemGroupA collection of objects providing system monitoring information.deprecated Unknown .1.3.6.1.4.1.19746.0.2.16 |
artGroupA collection of objects providing art monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.17 |
mtreeGroupA collection of objects providing mtree monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.18 |
enclosureGroupA collection of objects providing enclousure information. Unknown .1.3.6.1.4.1.19746.0.2.19 |
managedObjectsGroupA collection of objects providing ddms system information. Unknown .1.3.6.1.4.1.19746.0.2.20 |
networkGroupA collection of objects providing network information. Unknown .1.3.6.1.4.1.19746.0.2.21 |
fileSystemGroupRev1A collection of objects providing file system monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.22 |
ddsystemGroupRev1A collection of objects providing system monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.23 |
smtGroupA collection of objects providing Secure Multi-Tenancy (SMT) information. Unknown .1.3.6.1.4.1.19746.0.2.24 |
quotaGroupA collection of objects providing quota information. Unknown .1.3.6.1.4.1.19746.0.2.25 |
ddboostGroupRev1A collection of objects providing DDBoost monitoring information.deprecated Unknown .1.3.6.1.4.1.19746.0.2.26 |
ddboostGroupRev2A collection of objects providing DDBoost monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.27 |
highAvailabilityGroupA collection of objects providing High Availability information. Unknown .1.3.6.1.4.1.19746.0.2.28 |
scsitargetObjectGroupA collection of objects providing Scsitarget information. Unknown .1.3.6.1.4.1.19746.0.2.29 |
cifsGroupRev1A collection of objects providing CIFS monitoring information. Unknown .1.3.6.1.4.1.19746.0.2.30 |
generatedNotificationsGroupA collection of objects providing notifications, automatically generated by build. Unknown .1.3.6.1.4.1.19746.0.2.5000 |
dataDomainMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1 |
environmentals OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1 |
power OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1.1 |
powerModules OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1.1.1 |
powerModuleTableA table containing entries of PowerModuleEntry. SEQUENCE OF PowerModuleEntry .1.3.6.1.4.1.19746.1.1.1.1.1 |
powerModuleEntrypowerModuleTable Row Description PowerModuleEntry .1.3.6.1.4.1.19746.1.1.1.1.1.1 |
powerEnclosureIDPower Module Enclosure ID EnclosureID .1.3.6.1.4.1.19746.1.1.1.1.1.1.1 |
powerModuleIndexPower Module index PowerModuleIndexTC .1.3.6.1.4.1.19746.1.1.1.1.1.1.2 |
powerModuleDescriptionPower Module Descriptionro PowerModuleDescriptionTC .1.3.6.1.4.1.19746.1.1.1.1.1.1.3 |
powerModuleStatuscurrent enclosure Power Module statusro PowerModuleStatusTC .1.3.6.1.4.1.19746.1.1.1.1.1.1.4 |
temperatures OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1.2 |
temperatureSensors OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1.2.1 |
temperatureSensorTableA table containing entries of TemperatureSensorEntry. SEQUENCE OF TemperatureSensorEntry .1.3.6.1.4.1.19746.1.1.2.1.1 |
temperatureSensorEntrytemperatureSensorTable Row Description TemperatureSensorEntry .1.3.6.1.4.1.19746.1.1.2.1.1.1 |
tempEnclosureIDTemperature Sensor Enclosure ID EnclosureID .1.3.6.1.4.1.19746.1.1.2.1.1.1.1 |
tempSensorIndexTemperature Sensor Number TempSensorIndexTC .1.3.6.1.4.1.19746.1.1.2.1.1.1.2 |
tempSensorTrapIndexTemperature Sensor Number Used for Trapsro TempSensorIndexTC .1.3.6.1.4.1.19746.1.1.2.1.1.1.3 |
tempSensorDescriptionTemperature Sensor Descriptionro TempSensorDescriptionTC .1.3.6.1.4.1.19746.1.1.2.1.1.1.4 |
tempSensorCurrentValueCurrent Temperature Value of the sensorro Temperature .1.3.6.1.4.1.19746.1.1.2.1.1.1.5 |
tempSensorStatusCurrent status of the sensorro TempSensorStatusTC .1.3.6.1.4.1.19746.1.1.2.1.1.1.6 |
fans OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1.3 |
fanProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.1.3.1 |
fanPropertiesTableA table containing entries of FanPropertiesEntry. SEQUENCE OF FanPropertiesEntry .1.3.6.1.4.1.19746.1.1.3.1.1 |
fanPropertiesEntryfanPropertiesTable Row Description FanPropertiesEntry .1.3.6.1.4.1.19746.1.1.3.1.1.1 |
fanEnclosureIDEnclosure ID of fan EnclosureID .1.3.6.1.4.1.19746.1.1.3.1.1.1.1 |
fanIndexFan Number Index of the fan FanIndexTC .1.3.6.1.4.1.19746.1.1.3.1.1.1.2 |
fanTrapIndexFan Number trap index, used for trap notificationsro FanIndexTC .1.3.6.1.4.1.19746.1.1.3.1.1.1.3 |
fanDescriptionVendor supplied description of the fanro FanDescriptionTC .1.3.6.1.4.1.19746.1.1.3.1.1.1.4 |
fanLevelcurrent run level of fanro FanLevelTC .1.3.6.1.4.1.19746.1.1.3.1.1.1.5 |
fanStatusCurrent status of the fanro FanStatusTC .1.3.6.1.4.1.19746.1.1.3.1.1.1.6 |
nvram OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.2 |
nvramProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.2.1 |
nvramPropertiesTableA table containing entries of NvramPropertiesEntry. SEQUENCE OF NvramPropertiesEntry .1.3.6.1.4.1.19746.1.2.1.1 |
nvramPropertiesEntrynvramPropertiesTable Row Description NvramPropertiesEntry .1.3.6.1.4.1.19746.1.2.1.1.1 |
nvramPropertiesIndexNVRAM card index NvramIndexTC .1.3.6.1.4.1.19746.1.2.1.1.1.1 |
nvramMemorySizeSize of NVRAM Memory in bytesro NvramMemorySizeTC .1.3.6.1.4.1.19746.1.2.1.1.1.2 |
nvramWindowSizeWindow size of NVRAM in bytesro NvramWindowSizeTC .1.3.6.1.4.1.19746.1.2.1.1.1.3 |
nvramHCMemorySizeThe size of an NVRAM entity's memory in bytes, with support for high capacity modules. This entry may be used in place of nvramMemorySize.ro NvramHCPropertyBytesTC .1.3.6.1.4.1.19746.1.2.1.1.1.4 |
nvramStats OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.2.2 |
nvramStatsTableA table containing entries of NvramStatsEntry. SEQUENCE OF NvramStatsEntry .1.3.6.1.4.1.19746.1.2.2.1 |
nvramStatsEntrynvramStatsTable Row Description NvramStatsEntry .1.3.6.1.4.1.19746.1.2.2.1.1 |
nvramStatsIndexNVRAM card index NvramIndexTC .1.3.6.1.4.1.19746.1.2.2.1.1.1 |
nvramPCIErrorCountNumber of PCI Errors Encountered on NVRAM Cardro ErrorCount .1.3.6.1.4.1.19746.1.2.2.1.1.2 |
nvramMemoryErrorCountNumber of Memory Errors Encountered on NVRAM Cardro ErrorCount .1.3.6.1.4.1.19746.1.2.2.1.1.3 |
nvramBatteries OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.2.3 |
nvramBatteryTableA table containing entries of NvramBatteryEntry. SEQUENCE OF NvramBatteryEntry .1.3.6.1.4.1.19746.1.2.3.1 |
nvramBatteryEntrynvramBatteryTable Row Description NvramBatteryEntry .1.3.6.1.4.1.19746.1.2.3.1.1 |
nvramBatteriesIndexNVRAM card index NvramIndexTC .1.3.6.1.4.1.19746.1.2.3.1.1.1 |
nvramBatteryIndexNVRAM Battery Number NvramBatteryIndexTC .1.3.6.1.4.1.19746.1.2.3.1.1.2 |
nvramBatteryStatusNVRAM Battery Statusro NvramBatteryStatusTC .1.3.6.1.4.1.19746.1.2.3.1.1.3 |
nvramBatteryChargeNVRAM Battery charge percentagero Percentage .1.3.6.1.4.1.19746.1.2.3.1.1.4 |
fileSystem OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3 |
fileSystemProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3.1 |
fileSystemStatusStatus of the file systemro FileSystemStatusTC .1.3.6.1.4.1.19746.1.3.1.1 |
fileSystemVirtualSpaceAmount of Uncompressed data that has been backed up by the systemro FileSystemSpaceUnitTC .1.3.6.1.4.1.19746.1.3.1.2 |
fileSystemUpTimeFile System Up timero DDMibTimeStampTC .1.3.6.1.4.1.19746.1.3.1.3 |
fileSystemStatusMessagefile system status messagero DDMibTableString256TC .1.3.6.1.4.1.19746.1.3.1.4 |
fileSystemSpace OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3.2 |
fileSystemSpaceTableA table containing entries of FileSystemSpaceEntry. SEQUENCE OF FileSystemSpaceEntry .1.3.6.1.4.1.19746.1.3.2.1 |
fileSystemSpaceEntryfileSystemSpaceTable Row Description FileSystemSpaceEntry .1.3.6.1.4.1.19746.1.3.2.1.1 |
fileSystemResourceIndexFile system resource index FileSystemResourceIndexTC .1.3.6.1.4.1.19746.1.3.2.1.1.1 |
fileSystemResourceTrapIndexFile system resource trap indexro FileSystemResourceIndexTC .1.3.6.1.4.1.19746.1.3.2.1.1.2 |
fileSystemResourceNameFile system resource namero FileSystemResourceNameTC .1.3.6.1.4.1.19746.1.3.2.1.1.3 |
fileSystemSpaceSizeSize of the file system resource in gigabytesro FileSystemSpaceUnitTC .1.3.6.1.4.1.19746.1.3.2.1.1.4 |
fileSystemSpaceUsedAmount of used space within the file system resource in gigabytesro FileSystemSpaceUnitTC .1.3.6.1.4.1.19746.1.3.2.1.1.5 |
fileSystemSpaceAvailAmount of available space within the file system resource in gigabytesro FileSystemSpaceUnitTC .1.3.6.1.4.1.19746.1.3.2.1.1.6 |
fileSystemPercentUsedPercentage of used space within the file system resourcero Percentage .1.3.6.1.4.1.19746.1.3.2.1.1.7 |
fileSystemSpaceCleanableAmount of cleanable space within the file system resourcero FileSystemSpaceUnitTC .1.3.6.1.4.1.19746.1.3.2.1.1.8 |
fileSystemResourceTierThe tier that a resource belongs to, such as active or archive.ro DDMibTableString128TC .1.3.6.1.4.1.19746.1.3.2.1.1.9 |
fileSystemCompression OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3.3 |
fileSystemCompressionTableA table containing entries of FileSystemCompressionEntry. SEQUENCE OF FileSystemCompressionEntry .1.3.6.1.4.1.19746.1.3.3.1 |
fileSystemCompressionEntryfileSystemCompressionTable Row Description FileSystemCompressionEntry .1.3.6.1.4.1.19746.1.3.3.1.1 |
fileSystemCompressionIndexFile system compression index FileSystemResourceIndexTC .1.3.6.1.4.1.19746.1.3.3.1.1.1 |
fileSystemCompressionPeriodFile system compression periodro FileSystemCompressionPeriodTC .1.3.6.1.4.1.19746.1.3.3.1.1.2 |
fileSystemCompressionStartTimeFile system compression start timero DateTC .1.3.6.1.4.1.19746.1.3.3.1.1.3 |
fileSystemCompressionEndTimeFile system compression end timero DateTC .1.3.6.1.4.1.19746.1.3.3.1.1.4 |
fileSystemPreCompressionSizeSize of the file system pre compression in gigabytesro FileSystemCompressionSizeTC .1.3.6.1.4.1.19746.1.3.3.1.1.5 |
fileSystemPostCompressionSizeSize of the file system post compression in gigabytesro FileSystemCompressionSizeTC .1.3.6.1.4.1.19746.1.3.3.1.1.6 |
fileSystemGlobalCompressionFactorFile system global compression factorro FileSystemCompressionFactorTC .1.3.6.1.4.1.19746.1.3.3.1.1.7 |
fileSystemLocalCompressionFactorFile system local compression factorro FileSystemCompressionFactorTC .1.3.6.1.4.1.19746.1.3.3.1.1.8 |
fileSystemTotalCompressionFactorFile system Total compression factorro FileSystemCompressionFactorTC .1.3.6.1.4.1.19746.1.3.3.1.1.9 |
fileSystemReductionPercentFile system Reduction Percentrodeprecated Percentage .1.3.6.1.4.1.19746.1.3.3.1.1.10 |
fileSystemReductionPercent1File system Reduction Percentro PercentageStr .1.3.6.1.4.1.19746.1.3.3.1.1.11 |
fileSystemOptions OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3.4 |
fileSystemOptionsTableA table containing entries of fileSystemOptionsEntry. SEQUENCE OF FileSystemOptionsEntry .1.3.6.1.4.1.19746.1.3.4.1 |
fileSystemOptionsEntryfileSystemOptionsTable Row Description FileSystemOptionsEntry .1.3.6.1.4.1.19746.1.3.4.1.1 |
fileSystemOptionsIndexfileSystem Options index FileSystemOptionsIndexTC .1.3.6.1.4.1.19746.1.3.4.1.1.1 |
fileSystemOptionsNameThis object represents the fileSystem Options type in text format. Below lists the possible options and their representations. -------------------------------- -------------------------- Option Name Representation in text -------------------------------- -------------------------- Local compression type gz/gzfast/lz Marker-type auto/cv1 Report-replica-as-writable enabled/disabled Low-bw-optim replication support enabled/disabled Current global compression type 1/9 Staging reserve % of the total space/disabled Staging clean % of staging reserve space Staging delete suspend % of staging reserve space -------------------------------- ---------------------------ro FileSystemOptionsNameTC .1.3.6.1.4.1.19746.1.3.4.1.1.2 |
fileSystemOptionsValuefileSystem Options Valuero FileSystemOptionsValueTC .1.3.6.1.4.1.19746.1.3.4.1.1.3 |
fileSystemClean OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3.5 |
fileSystemCleanTableA table containing entries of fileSystemCleanEntry. SEQUENCE OF FileSystemCleanEntry .1.3.6.1.4.1.19746.1.3.5.1 |
fileSystemCleanEntryfileSystemCleanTable Row Description FileSystemCleanEntry .1.3.6.1.4.1.19746.1.3.5.1.1 |
fileSystemCleanIndexfileSystem Clean index FileSystemCleanIndexTC .1.3.6.1.4.1.19746.1.3.5.1.1.1 |
fileSystemCleanStatusfileSystem Clean Statusro FileSystemCleanStatusTC .1.3.6.1.4.1.19746.1.3.5.1.1.2 |
fileSystemCleanSchedulefileSystem Clean Schedulero FileSystemCleanScheduleTC .1.3.6.1.4.1.19746.1.3.5.1.1.3 |
fileSystemCleanThrottlefileSystem Clean Throttlero FileSystemCleanThrottleTC .1.3.6.1.4.1.19746.1.3.5.1.1.4 |
fileSystemArchiveUnit OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.3.6 |
fileSystemArchiveUnitTableA table containing entries of fileSystemArchiveUnitEntry. SEQUENCE OF FileSystemArchiveUnitEntry .1.3.6.1.4.1.19746.1.3.6.1 |
fileSystemArchiveUnitEntryfileSystemArchiveUnitTable Row Description FileSystemArchiveUnitEntry .1.3.6.1.4.1.19746.1.3.6.1.1 |
fileSystemArchiveUnitIndexfileSystem ArchiveUnit index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.3.6.1.1.1 |
fileSystemArchiveUnitNamefileSystem ArchiveUnit Namero DDMibTableString256TC .1.3.6.1.4.1.19746.1.3.6.1.1.2 |
fileSystemArchiveUnitStatefileSystem ArchiveUnit Statero FileSystemArchiveUnitStateTC .1.3.6.1.4.1.19746.1.3.6.1.1.3 |
fileSystemArchiveUnitStatusfileSystem ArchiveUnit Statusro FileSystemArchiveUnitStatusTC .1.3.6.1.4.1.19746.1.3.6.1.1.4 |
fileSystemArchiveUnitStartTimefileSystem ArchiveUnit start Timero DDMibTimeStampTC .1.3.6.1.4.1.19746.1.3.6.1.1.5 |
fileSystemArchiveUnitEndTimefileSystem ArchiveUnit End Timero DDMibTimeStampTC .1.3.6.1.4.1.19746.1.3.6.1.1.6 |
fileSystemArchiveUnitSizefileSystem ArchiveUnit Size in Gibro DDMibTableSizeGibTC .1.3.6.1.4.1.19746.1.3.6.1.1.7 |
fileSystemArchiveUnitDiskGroupsfileSystem ArchiveUnit DiskGroupsro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.3.6.1.1.8 |
alerts OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.4 |
currentAlerts OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.4.1 |
currentAlertTableA table containing entries of CurrentAlertEntry. SEQUENCE OF CurrentAlertEntry .1.3.6.1.4.1.19746.1.4.1.1 |
currentAlertEntrycurrentAlertTable Row Description CurrentAlertEntry .1.3.6.1.4.1.19746.1.4.1.1.1 |
currentAlertIndexCurrent Alert Row index AlertIndexTC .1.3.6.1.4.1.19746.1.4.1.1.1.1 |
currentAlertTimestampTimestamp of current alertro AlertTimestampTC .1.3.6.1.4.1.19746.1.4.1.1.1.2 |
currentAlertDescriptionAlert Descriptionro AlertDescriptionTC .1.3.6.1.4.1.19746.1.4.1.1.1.3 |
currentAlertSeverityAlert Severityro DDMibAlertSeverityTC .1.3.6.1.4.1.19746.1.4.1.1.1.4 |
currentAlertIDAlert IDro DDMibTableString32TC .1.3.6.1.4.1.19746.1.4.1.1.1.5 |
alertHistory OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.4.2 |
alertHistoryTableA table containing entries of Alert History Entries. SEQUENCE OF AlertHistoryEntry .1.3.6.1.4.1.19746.1.4.2.1 |
alertHistoryEntryalertHistoryTable Row Description AlertHistoryEntry .1.3.6.1.4.1.19746.1.4.2.1.1 |
alertHistoryIndexAlert History Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.4.2.1.1.1 |
alertHistoryTimestampTimestamp of alertro DDMibTimeStampTC .1.3.6.1.4.1.19746.1.4.2.1.1.2 |
alertHistoryDescriptionAlert history Descriptionro DDMibTableString256TC .1.3.6.1.4.1.19746.1.4.2.1.1.3 |
alertHistorySeverityAlert history Severityro DDMibAlertSeverityTC .1.3.6.1.4.1.19746.1.4.2.1.1.4 |
alertHistoryStatusAlert history Status (Post or Cleared)ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.4.2.1.1.5 |
alertInfo OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.4.3 |
alertInfoTableA table containing entries of Alert Information. SEQUENCE OF AlertInfoEntry .1.3.6.1.4.1.19746.1.4.3.1 |
alertInfoEntryalertInfoTable Row Description AlertInfoEntry .1.3.6.1.4.1.19746.1.4.3.1.1 |
alertInfoIndexAlert Info Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.4.3.1.1.1 |
alertInfoDescriptionAlert Info Descriptionro DDMibTableString256TC .1.3.6.1.4.1.19746.1.4.3.1.1.2 |
statistics OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.5 |
systemStats OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.5.1 |
systemStatsTableA table containing entries of SystemStatsEntry. SEQUENCE OF SystemStatsEntry .1.3.6.1.4.1.19746.1.5.1.1 |
systemStatsEntrysystemStatsTable Row Description SystemStatsEntry .1.3.6.1.4.1.19746.1.5.1.1.1 |
systemStatsIndexSystem Stats Row index SystemStatsIndexTC .1.3.6.1.4.1.19746.1.5.1.1.1.1 |
cpuAvgPercentageBusyCPU Average Percentage Busyro Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.2 |
cpuMaxPercentageBusyCPU Max Percentage Busyro Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.3 |
nfsOpsPerSecondNumber of NFS Operations performed per secondro OpsPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.4 |
nfsIdlePercentagePercentage of time NFS was Idlero Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.5 |
nfsProcPercentagePercentage of time NFS was processingro Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.6 |
nfsSendPercentagePercentage of time NFS was sending requestsro Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.7 |
nfsReceivePercentagePercentage of time NFS was receiving requestsro Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.8 |
cifsOpsPerSecondNumber of CIFS Operations performed per secondro OpsPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.9 |
diskReadKBytesPerSecondNumber of KBytes per second read from diskro KBytesPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.10 |
diskWriteKBytesPerSecondNumber of KBytes per second written on diskro KBytesPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.11 |
diskBusyPercentagePercentage of Time Disks were busyro Percentage .1.3.6.1.4.1.19746.1.5.1.1.1.12 |
nvramReadKBytesPerSecondNumber of KBytes read per second from NVRAMro KBytesPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.13 |
nvramWriteKBytesPerSecondNumber of KBytes written per second on NVRAMro KBytesPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.14 |
replInKBytesPerSecondNumber of KBytes per second received for Replicationro KBytesPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.15 |
replOutKBytesPerSecondNumber of KBytes per second sent for Replicationro KBytesPerSecond .1.3.6.1.4.1.19746.1.5.1.1.1.16 |
diskStorage OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.6 |
diskProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.6.1 |
diskPropertiesTableA table containing entries of DiskPropertiesEntry. SEQUENCE OF DiskPropertiesEntry .1.3.6.1.4.1.19746.1.6.1.1 |
diskPropertiesEntrydiskPropertiesTable Row Description DiskPropertiesEntry .1.3.6.1.4.1.19746.1.6.1.1.1 |
diskPropEnclosureIDEnclosure ID of disk EnclosureID .1.3.6.1.4.1.19746.1.6.1.1.1.1 |
diskPropIndexDisk Number DiskIndexTC .1.3.6.1.4.1.19746.1.6.1.1.1.2 |
diskPropTrapIndexDisk Number for Trapsro DiskIndexTC .1.3.6.1.4.1.19746.1.6.1.1.1.3 |
diskModelManufacture and model of the diskro DiskModelTC .1.3.6.1.4.1.19746.1.6.1.1.1.4 |
diskFirmwareVersionFirmware version of the diskro DiskFirmwareVersionTC .1.3.6.1.4.1.19746.1.6.1.1.1.5 |
diskSerialNumberSerial Number of the diskro DiskSerialNumberTC .1.3.6.1.4.1.19746.1.6.1.1.1.6 |
diskCapacityCapacity of the diskro DiskCapacityTC .1.3.6.1.4.1.19746.1.6.1.1.1.7 |
diskPropStateCurrent State of the diskro DiskStateTC .1.3.6.1.4.1.19746.1.6.1.1.1.8 |
diskPackPack information of the disk. Applicable to enclosures with packs such as ES60, and not for ES20 or ES30.ro DiskPackTC .1.3.6.1.4.1.19746.1.6.1.1.1.9 |
diskPerformance OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.6.2 |
diskPerformanceTableA table containing entries of DiskPerformanceEntry. SEQUENCE OF DiskPerformanceEntry .1.3.6.1.4.1.19746.1.6.2.1 |
diskPerformanceEntrydiskPerformanceTable Row Description DiskPerformanceEntry .1.3.6.1.4.1.19746.1.6.2.1.1 |
diskPerfEnclosureIDEnclosure ID of disk EnclosureID .1.3.6.1.4.1.19746.1.6.2.1.1.1 |
diskPerfIndexDisk Number DiskIndexTC .1.3.6.1.4.1.19746.1.6.2.1.1.2 |
diskSectorsReadNumber of disk sectors read per secondro DiskSectorsPerSecondTC .1.3.6.1.4.1.19746.1.6.2.1.1.3 |
diskSectorsWrittenNumber of disk sectors written per secondro DiskSectorsPerSecondTC .1.3.6.1.4.1.19746.1.6.2.1.1.4 |
diskTotalKBytesTotal Number of Kilo-bytes read/written per secondro KBytesPerSecond .1.3.6.1.4.1.19746.1.6.2.1.1.5 |
diskBusyPercentage of time disk is busyro Percentage .1.3.6.1.4.1.19746.1.6.2.1.1.6 |
diskPerfStateCurrent State of the diskro DiskStateTC .1.3.6.1.4.1.19746.1.6.2.1.1.7 |
diskReliability OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.6.3 |
diskReliabilityTableA table containing entries of DiskReliabilityEntry. SEQUENCE OF DiskReliabilityEntry .1.3.6.1.4.1.19746.1.6.3.1 |
diskReliabilityEntrydiskReliabilityTable Row Description DiskReliabilityEntry .1.3.6.1.4.1.19746.1.6.3.1.1 |
diskErrEnclosureIDEnclosure ID of disk EnclosureID .1.3.6.1.4.1.19746.1.6.3.1.1.1 |
diskErrIndexDisk Number DiskIndexTC .1.3.6.1.4.1.19746.1.6.3.1.1.2 |
diskErrTrapIndexDisk Number for Trapsro DiskIndexTC .1.3.6.1.4.1.19746.1.6.3.1.1.3 |
diskTemperatureCurrent Disk Temperature in Celsiusro Temperature .1.3.6.1.4.1.19746.1.6.3.1.1.4 |
diskTimeoutCountNumber of command timeoutsro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.5 |
diskReadFailCountNumber of read failuresro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.6 |
diskWriteFailCountNumber of write failuresro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.7 |
diskMiscFailCountNumber of miscellaneous failuresro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.8 |
diskOffTrackErrCountNumber of offtrack errorsro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.9 |
diskSoftEccCountNumber of soft ecc errorsro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.10 |
diskCrcErrCountNumber of crc errorsro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.11 |
diskProbationalCountNumber of probational errorsro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.12 |
diskReallocCountNumber of reallocation errorsro ErrorCount .1.3.6.1.4.1.19746.1.6.3.1.1.13 |
diskErrStateCurrent State of the diskro DiskStateTC .1.3.6.1.4.1.19746.1.6.3.1.1.14 |
replication OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.8 |
replicationInfo OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.8.1 |
replicationInfoTableA table containing entries of ReplicationInfoEntry. SEQUENCE OF ReplicationInfoEntry .1.3.6.1.4.1.19746.1.8.1.1 |
replicationInfoEntryreplicationInfoTable Row Description ReplicationInfoEntry .1.3.6.1.4.1.19746.1.8.1.1.1 |
replContextcontext ID of replication source/dest pair ReplicationContextTC .1.3.6.1.4.1.19746.1.8.1.1.1.1 |
replTrapContextcontext ID of replication source/dest pair for trapsro ReplicationContextTC .1.3.6.1.4.1.19746.1.8.1.1.1.2 |
replStatestate of replication source/dest pairro ReplicationStateTC .1.3.6.1.4.1.19746.1.8.1.1.1.3 |
replStatusstatus of replication source/dest pair connectionro ReplicationStatusTC .1.3.6.1.4.1.19746.1.8.1.1.1.4 |
replFileSysStatusstatus of filesystemro FileSystemStatusTC .1.3.6.1.4.1.19746.1.8.1.1.1.5 |
replConnTimetime of connection established between source and dest, or time since disconnect if status is 'disconnected'ro ReplicationConnectTimeTC .1.3.6.1.4.1.19746.1.8.1.1.1.6 |
replSourcenetwork path to replication source directoryro ReplicationPathTC .1.3.6.1.4.1.19746.1.8.1.1.1.7 |
replDestinationnetwork path to replication destination directoryro ReplicationPathTC .1.3.6.1.4.1.19746.1.8.1.1.1.8 |
replPreCompBytesSentpre compression bytes sentro ReplicationTrafficTC .1.3.6.1.4.1.19746.1.8.1.1.1.9 |
replPostCompBytesSentpost compression bytes sentro ReplicationTrafficTC .1.3.6.1.4.1.19746.1.8.1.1.1.10 |
replPreCompBytesRemainingpre compression bytes remainingro ReplicationTrafficTC .1.3.6.1.4.1.19746.1.8.1.1.1.11 |
replPostCompBytesReceivedpost compression bytes receivedro ReplicationTrafficTC .1.3.6.1.4.1.19746.1.8.1.1.1.12 |
replThrottlereplication throttle in bps -- -1 is disabled, 0 unlimitedro ReplicationThrottleTC .1.3.6.1.4.1.19746.1.8.1.1.1.13 |
replSyncedAsOfTimetime when the source and destination were in sync, or 0 if the time is unknownro ReplicationSyncedTimeTC .1.3.6.1.4.1.19746.1.8.1.1.1.14 |
replicationConfig OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.8.2 |
replicationConfigTableA table containing entries of ReplicationConfigEntry. SEQUENCE OF ReplicationConfigEntry .1.3.6.1.4.1.19746.1.8.2.1 |
replicationConfigEntryreplicationConfigTable Row Description ReplicationConfigEntry .1.3.6.1.4.1.19746.1.8.2.1.1 |
replConfigIndexConfigIndex ID of replication source/dest pair ReplicationConfigIndexTC .1.3.6.1.4.1.19746.1.8.2.1.1.1 |
replConfigContextIdConfigContextId of replication source/dest pairro ReplicationConfigContextIdTC .1.3.6.1.4.1.19746.1.8.2.1.1.2 |
replConfigSourceSource for replication source/dest pair connectionro ReplicationConfigSourceTC .1.3.6.1.4.1.19746.1.8.2.1.1.3 |
replConfigDestDestination for replication connectionro ReplicationConfigDestTC .1.3.6.1.4.1.19746.1.8.2.1.1.4 |
replConfigConnHostHost for a replication connectionro ReplicationConfigConnHostTC .1.3.6.1.4.1.19746.1.8.2.1.1.5 |
replConfigConnPortReplication Configuration port for the connectionro ReplicationConfigConnPortTC .1.3.6.1.4.1.19746.1.8.2.1.1.6 |
replConfigLowBWOptimReplication configuration Low BW optimro ReplicationConfigLowBWOptimTC .1.3.6.1.4.1.19746.1.8.2.1.1.7 |
replConfigEnabledReplication config Enabledro ReplicationConfigEnabledTC .1.3.6.1.4.1.19746.1.8.2.1.1.8 |
replConfigTenantUnitThe name of the tenant-unit of a particular replication context.ro DDMibString96TC .1.3.6.1.4.1.19746.1.8.2.1.1.9 |
replicationHistory OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.8.3 |
replicationHistoryTableA table containing entries of replicationHistoryEntry. SEQUENCE OF ReplicationHistoryEntry .1.3.6.1.4.1.19746.1.8.3.1 |
replicationHistoryEntryreplicationHistoryTable Row Description ReplicationHistoryEntry .1.3.6.1.4.1.19746.1.8.3.1.1 |
replHistoryContextcontext ID of replication History source/dest pair DDMibTableIndexTC .1.3.6.1.4.1.19746.1.8.3.1.1.1 |
replHistoryDatereplication History Datero DDMibDateTC .1.3.6.1.4.1.19746.1.8.3.1.1.2 |
replHistoryTimereplication History Timero DDMibTimeStampTC .1.3.6.1.4.1.19746.1.8.3.1.1.3 |
replHistoryPreCompWrittenReplication History Pre comp bytes writtenro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.4 |
replHistoryPreCompRemainingReplication History Byte remainingro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.5 |
replHistoryPreCompressedReplication History Precompressed bytesro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.6 |
replHistoryPostFilteredreplication history post filtered bytesro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.7 |
replHistoryPostLowBwOptimReplication history Post Low BW Optimumro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.8 |
replHistoryPostLocalCompReplication History Post Local Compro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.9 |
replHistoryBytesNetworkReplication History network bytesro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.8.3.1.1.10 |
replHistorySyncedAsOfTimeTime when the source and destination were in sync, or 0 if the time is unknownro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.3.1.1.11 |
replicationPerformance OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.8.4 |
replicationPerformanceTableA table containing entries of replicationPerformanceEntry. SEQUENCE OF ReplicationPerformanceEntry .1.3.6.1.4.1.19746.1.8.4.1 |
replicationPerformanceEntryreplicationPerformanceTable Row Description ReplicationPerformanceEntry .1.3.6.1.4.1.19746.1.8.4.1.1 |
replPerformancePreCompKBPerSecNetwork (KB/s): The size value before compression is applied. Sometimes referred to as 'logical size.'ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.1 |
replPerformanceNetworkKBPerSecNetwork (KB/s): The amount of compressed data transferred over the network per second.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.2 |
replPerformanceStreamsAn internal system resource associated with reads and writes. One replication context can use multiple streams for better performance.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.3 |
replPerformanceBusyReadingThe time spent reading filesystem data from the local filesystem. Typically this number is the second highest number after Network. On a deployment with high network bandwidth, Reading may be the largest column.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.4 |
replPerformanceBusyMetaThe time spent on miscellaneous bookkeeping activities and replicating filesystem namespace operations. Typically this value is under 50. If this value exceeds 50 on a sustained basis, it may indicate an unusual workload (a large number of file attribute updates, for example).ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.5 |
replPerformanceWaitingDestThe time spent waiting due to the receiver not providing the sender enough information on what data to send. Typically this value is low. Exceptions include systems on high-speed networks where the sender is a more powerful Data Domain system than the replica, or where the replica has a higher workload than the sender because the replica is the destination for a multiple replication contexts.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.6 |
replPerformanceWaitingNetworkThe time spent waiting due to the receiver not providing the sender enough information on what data to send. Typically this value is low. Exceptions include systems on high-speed networks where the sender is a more powerful Data Domain system than the replica, or where the replica has a higher workload than the sender because the replica is the destination for a multiple replication contexts.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.8.4.1.1.7 |
nfs OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.9 |
nfsProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.9.1 |
nfsStatusStatus of the network file systemro NfsStatusTC .1.3.6.1.4.1.19746.1.9.1.1 |
nfsClient OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.9.2 |
nfsClientTableA table containing entries of NfsClientEntry. SEQUENCE OF NfsClientEntry .1.3.6.1.4.1.19746.1.9.2.1 |
nfsClientEntrynfsClientTable Row Description NfsClientEntry .1.3.6.1.4.1.19746.1.9.2.1.1 |
nfsClientIndexNFS client index NfsClientIndexTC .1.3.6.1.4.1.19746.1.9.2.1.1.1 |
nfsClientPathNFS client pathro NfsClientPathTC .1.3.6.1.4.1.19746.1.9.2.1.1.2 |
nfsClientClientsList of NFS clientsro NfsClientClientsTC .1.3.6.1.4.1.19746.1.9.2.1.1.3 |
nfsClientOptionsNFS client's optionsro NfsClientOptionsTC .1.3.6.1.4.1.19746.1.9.2.1.1.4 |
nfsStats OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.9.3 |
nfsStatsTableA table containing entries of NfsStatsEntry. SEQUENCE OF NfsStatsEntry .1.3.6.1.4.1.19746.1.9.3.1 |
nfsStatsEntrynfsStatsTable Row Description NfsStatsEntry .1.3.6.1.4.1.19746.1.9.3.1.1 |
nfsStatsIndexNFS resource index NfsStatsIndexTC .1.3.6.1.4.1.19746.1.9.3.1.1.1 |
nfsStatsExportPointNFS export pointro NfsStatsExportPointTC .1.3.6.1.4.1.19746.1.9.3.1.1.2 |
nfsStatsFilesystemTypeFile system typero NfsStatsFilesystemTypeTC .1.3.6.1.4.1.19746.1.9.3.1.1.3 |
nfsStatsCacheEntryNumber of cache entriesro NfsStatsCacheEntryTC .1.3.6.1.4.1.19746.1.9.3.1.1.4 |
nfsStatsFileHandleLookupFile handle lookup countro NfsStatsFileHandleLookupTC .1.3.6.1.4.1.19746.1.9.3.1.1.5 |
nfsStatsMaxCacheSizeMax cache sizero NfsStatsMaxCacheSizeTC .1.3.6.1.4.1.19746.1.9.3.1.1.6 |
nfsStatsCurrentOpenStreamsCurrent open stream countro NfsStatsCurrentOpenStreamsTC .1.3.6.1.4.1.19746.1.9.3.1.1.7 |
nfsActive OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.9.4 |
nfsActiveTableA table containing entries of Nfs Active Clients. SEQUENCE OF NfsActiveEntry .1.3.6.1.4.1.19746.1.9.4.1 |
nfsActiveEntrynfsActiveTable Row Description NfsActiveEntry .1.3.6.1.4.1.19746.1.9.4.1.1 |
nfsActiveIndexNFS Active index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.9.4.1.1.1 |
nfsActivePathNFS Active client pathro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.9.4.1.1.2 |
nfsActiveClientsNFS Active Clientro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.9.4.1.1.3 |
nfsPort OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.9.5 |
nfsPortTableA table containing entries of NfsPortEntry. SEQUENCE OF NfsPortEntry .1.3.6.1.4.1.19746.1.9.5.1 |
nfsPortEntrynfsPortTable Row Description NfsPortEntry .1.3.6.1.4.1.19746.1.9.5.1.1 |
nfsPortIndexNFS Port index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.9.5.1.1.1 |
nfsPortServiceNFS Port Service Namero DDMibTableString32TC .1.3.6.1.4.1.19746.1.9.5.1.1.2 |
nfsPortPortNFS Service Portro DDMibTableString32TC .1.3.6.1.4.1.19746.1.9.5.1.1.3 |
cifs OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.10 |
cifsProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.10.1 |
cifsStatusCIFS statusro CifsStatusTC .1.3.6.1.4.1.19746.1.10.1.1 |
cifsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.10.2 |
cifsConfigModeCIFS configuration modero CifsConfigModeTC .1.3.6.1.4.1.19746.1.10.2.1 |
cifsConfigWINSServerCIFS WINS serverro CifsConfigWINSServerTC .1.3.6.1.4.1.19746.1.10.2.2 |
cifsConfigNetBIOSHostnameCIFS Net BIOS hostnamero CifsConfigNetBIOSHostnameTC .1.3.6.1.4.1.19746.1.10.2.3 |
cifsConfigDomainControllerCIFS domain controllerro CifsConfigDomainControllerTC .1.3.6.1.4.1.19746.1.10.2.4 |
cifsConfigDNSCIFS DNS serverro CifsConfigDNSTC .1.3.6.1.4.1.19746.1.10.2.5 |
cifsConfigGroupNameCIFS configuration group namero CifsConfigGroupNameTC .1.3.6.1.4.1.19746.1.10.2.6 |
cifsConfigMaxConnectionCIFS configuration maximum connectionro CifsConfigMaxConnectionTC .1.3.6.1.4.1.19746.1.10.2.7 |
cifsConfigMaxOpenFilesPerConnectionCIFS configuration maximum open files per connectionrodeprecated CifsConfigMaxOpenFilesPerConnectionTC .1.3.6.1.4.1.19746.1.10.2.8 |
cifsConfigMaxOpenFilesCIFS configuration maximum open filesro Counter32 .1.3.6.1.4.1.19746.1.10.2.9 |
cifsShare OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.10.3 |
cifsShareTableA table containing entries of CifsShareEntry. SEQUENCE OF CifsShareEntry .1.3.6.1.4.1.19746.1.10.3.1 |
cifsShareEntrycifsShareTable Row Description CifsShareEntry .1.3.6.1.4.1.19746.1.10.3.1.1 |
cifsShareIndexCIFS share index CifsShareIndexTC .1.3.6.1.4.1.19746.1.10.3.1.1.1 |
cifsShareNameCIFS share namero CifsShareNameTC .1.3.6.1.4.1.19746.1.10.3.1.1.2 |
cifsSharePathCIFS share pathro CifsSharePathTC .1.3.6.1.4.1.19746.1.10.3.1.1.3 |
cifsShareClientsCIFS share clientsro CifsShareClientsTC .1.3.6.1.4.1.19746.1.10.3.1.1.4 |
cifsShareUserCIFS share userro CifsShareUserTC .1.3.6.1.4.1.19746.1.10.3.1.1.5 |
cifsShareCommentCIFS share commentro CifsShareCommentTC .1.3.6.1.4.1.19746.1.10.3.1.1.6 |
cifsShareBrowsingCIFS share browsingro CifsShareBrowsingTC .1.3.6.1.4.1.19746.1.10.3.1.1.7 |
cifsShareWriteableCIFS share writeablero CifsShareWriteableTC .1.3.6.1.4.1.19746.1.10.3.1.1.8 |
cifsShareMaxConnectionCIFS share maximum connectionro CifsShareMaxConnectionTC .1.3.6.1.4.1.19746.1.10.3.1.1.9 |
cifsOptions OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.10.5 |
cifsOptionsTableA table containing entries of CifsOptionsEntry. SEQUENCE OF CifsOptionsEntry .1.3.6.1.4.1.19746.1.10.5.1 |
cifsOptionsEntrycifsOptionsTable Row Description CifsOptionsEntry .1.3.6.1.4.1.19746.1.10.5.1.1 |
cifsOptionsIndexCIFS Options index CifsOptionsIndexTC .1.3.6.1.4.1.19746.1.10.5.1.1.1 |
cifsOptionsNameCIFS Options namero CifsOptionsNameTC .1.3.6.1.4.1.19746.1.10.5.1.1.2 |
cifsOptionsValueCIFS Options Valuero CifsOptionsValueTC .1.3.6.1.4.1.19746.1.10.5.1.1.3 |
vtl OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11 |
vtlProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.1 |
vtlAdminStateState of VTL administrationro VtlAdminStateTC .1.3.6.1.4.1.19746.1.11.1.1 |
vtlProcessStateState of VTL processro VtlProcessStateTC .1.3.6.1.4.1.19746.1.11.1.2 |
vtlConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2 |
vtlLibrary OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.1 |
vtlLibraryTableA table containing entries of VtlLibraryEntry. SEQUENCE OF VtlLibraryEntry .1.3.6.1.4.1.19746.1.11.2.1.1 |
vtlLibraryEntryvtlLibraryTable Row Description VtlLibraryEntry .1.3.6.1.4.1.19746.1.11.2.1.1.1 |
vtlLibraryIndexVTL Library index VtlLibraryIndexTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.1 |
vtlLibraryNameVTL library namero VtlLibraryNameTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.2 |
vtlLibraryVendorVTL library vendorro VtlLibraryVendorTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.3 |
vtlLibraryModelVTL library modelro VtlLibraryModelTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.4 |
vtlLibraryRevisionVTL library revisionro VtlLibraryRevisionTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.5 |
vtlLibrarySerialVTL library serialro VtlLibrarySerialTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.6 |
vtlLibraryTotalDrivesVTL library total drivesro VtlLibraryTotalDrivesTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.7 |
vtlLibraryTotalSlotsVTL library total slotsro VtlLibraryTotalSlotsTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.8 |
vtlLibraryTotalCapsVTL library total capsro VtlLibraryTotalCapsTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.9 |
vtlLibraryStatusVTL library statusro VtlLibraryStatusTC .1.3.6.1.4.1.19746.1.11.2.1.1.1.10 |
vtlDrive OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.2 |
vtlDriveTableA table containing entries of VtlDriveEntry. SEQUENCE OF VtlDriveEntry .1.3.6.1.4.1.19746.1.11.2.2.1 |
vtlDriveEntryvtlDriveTable Row Description VtlDriveEntry .1.3.6.1.4.1.19746.1.11.2.2.1.1 |
vtlDriveIndexVTL drive index VtlDriveIndexTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.1 |
vtlDriveNameVTL drive namero VtlDriveNameTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.2 |
vtlDriveVendorVTL drive vendorro VtlDriveVendorTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.3 |
vtlDriveModelVTL drive modelro VtlDriveModelTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.4 |
vtlDriveRevisionVTL drive revisionro VtlDriveRevisionTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.5 |
vtlDriveSerialVTL drive serialro VtlDriveSerialTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.6 |
vtlDriveLibraryNameVTL drive library namero VtlLibraryNameTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.7 |
vtlDriveStatusVTL drive statusro VtlDriveStatusTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.8 |
vtlDriveTapeVolumeVTL drive tape volumero VtlDriveTapeVolumeTC .1.3.6.1.4.1.19746.1.11.2.2.1.1.9 |
vtlPort OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.3 |
vtlPortTableA table containing entries of VtlPortEntry. SEQUENCE OF VtlPortEntry .1.3.6.1.4.1.19746.1.11.2.3.1 |
vtlPortEntryvtlPortTable Row Description VtlPortEntry .1.3.6.1.4.1.19746.1.11.2.3.1.1 |
vtlPortIndexVTL Port index VtlPortIndexTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.1 |
vtlPortNameVTL Port namero VtlPortNameTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.2 |
vtlPortIDVTL Port IDro VtlPortIDTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.3 |
vtlPortModelVTL Port modelro VtlPortModelTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.4 |
vtlPortFirmwareVTL Port Firmware Versionro VtlPortFirmwareTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.5 |
vtlPortWWNNVTL Port WWNN addressro VtlPortWWNNTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.6 |
vtlPortWWPNVTL Port WWPN Addressro VtlPortWWPNTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.7 |
vtlPortConnectionTypeVTL Port Connection Typero VtlPortConnectionTypeTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.8 |
vtlPortSpeedVTL Port Speed in Gibsro VtlPortSpeedTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.9 |
vtlPortEnabledVTL Port Enabledro VtlPortEnabledTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.10 |
vtlPortStatusVTL Port Statusro VtlPortStatusTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.11 |
vtlPortTrapIndexVTL Port indexro VtlPortIndexTC .1.3.6.1.4.1.19746.1.11.2.3.1.1.12 |
vtlTape OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.4 |
vtlTapeTableA table containing entries of VtlTapeEntry. SEQUENCE OF VtlTapeEntry .1.3.6.1.4.1.19746.1.11.2.4.1 |
vtlTapeEntryvtlTapeTable Row Description VtlTapeEntry .1.3.6.1.4.1.19746.1.11.2.4.1.1 |
vtlTapeIndexVTL Tape index VtlTapeIndexTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.1 |
vtlTapeBarCodeVTL Tape BarCodero VtlTapeBarCodeTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.2 |
vtlTapePoolVTL Tape Poolro VtlTapePoolTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.3 |
vtlTapeLocationVTL Tape Locationro VtlTapeLocationTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.4 |
vtlTapeStateVTL Tape Statero VtlTapeStateTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.5 |
vtlTapeSizeVTL Tape Sizero VtlTapeSizeTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.6 |
vtlTapeUsedVTL Tape Usedro VtlTapeUsedTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.7 |
vtlTapeCompVTL Tape Compressionro VtlTapeCompTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.8 |
vtlTapeModTimeVTL Tape statusro VtlTapeModTimeTC .1.3.6.1.4.1.19746.1.11.2.4.1.1.9 |
vtlPool OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.6 |
vtlPoolTableA table containing entries of VtlPoolEntry. SEQUENCE OF VtlPoolEntry .1.3.6.1.4.1.19746.1.11.2.6.1 |
vtlPoolEntryvtlPoolTable Row Description VtlPoolEntry .1.3.6.1.4.1.19746.1.11.2.6.1.1 |
vtlPoolIndexVTL Pool index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.11.2.6.1.1.1 |
vtlPoolPoolVTL Pool Poolro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.6.1.1.2 |
vtlPoolStatusVTL Pool Statusro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.6.1.1.3 |
vtlPoolTapesVTL Pool Tapesro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.6.1.1.4 |
vtlPoolSizeVTL Pool Sizero DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.6.1.1.5 |
vtlPoolUsedVTL Pool Usedro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.6.1.1.6 |
vtlPoolCompVTL Pool Compressionro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.6.1.1.7 |
vtlGroups OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.7 |
vtlGroupTableA table containing entries of VtlGroupEntry. SEQUENCE OF VtlGroupEntry .1.3.6.1.4.1.19746.1.11.2.7.1 |
vtlGroupEntryvtlGroupTable Row Description VtlGroupEntry .1.3.6.1.4.1.19746.1.11.2.7.1.1 |
vtlGroupIndexVTL Group index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.11.2.7.1.1.1 |
vtlGroupNameVTL Group Namero DDMibTableString32TC .1.3.6.1.4.1.19746.1.11.2.7.1.1.2 |
vtlGroupInitiaterCountVTL Group Initiater Countro DDMibInteger32TC .1.3.6.1.4.1.19746.1.11.2.7.1.1.3 |
vtlGroupDeviceCountVTL Group Device Countro DDMibInteger32TC .1.3.6.1.4.1.19746.1.11.2.7.1.1.4 |
vtlGroupDeviceTableThis table contains information about the devices in VTL groups. It provides information such as the Device Name, the Device LUN, the Primary Ports, Secondary Ports, In-Use Ports, and Group Name. It is comprised of entries of VtlGroupDeviceEntry. SEQUENCE OF VtlGroupDeviceEntry .1.3.6.1.4.1.19746.1.11.2.7.2 |
vtlGroupDeviceEntryInformation about the devices in a VTL group. VtlGroupDeviceEntry .1.3.6.1.4.1.19746.1.11.2.7.2.1 |
vtlGroupDeviceIndexThe index of a VTL Device. DDMibTableIndexTC .1.3.6.1.4.1.19746.1.11.2.7.2.1.2 |
vtlGroupDeviceGroupNameThe name of a VTL Group.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.11.2.7.2.1.3 |
vtlGroupDeviceDeviceNameThe name of a VTL Device.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.11.2.7.2.1.4 |
vtlGroupDeviceLunThe LUN (Logical Unit Number) of a VTL Device.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.11.2.7.2.1.5 |
vtlGroupDevicePrimaryPortsThe Primary Ports of a VTL Device. This entry specifies a set of ports that the device will be visible on. If 'all' is provided the device is visible on all ports. If 'none' is provided the device is visible on none of the ports.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.7.2.1.6 |
vtlGroupDeviceSecondaryPortsThe Secondary Ports of a VTL Device. This entry specifies a second set of ports that the device will be visible on. The administrator can switch the ports in use in a group to the primary or secondary port list.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.7.2.1.7 |
vtlGroupDeviceInUsePortsThe In-Use Ports of a VTL Device. The port list that the device is visible on is the in-use port list, which can be the primary or secondary port list.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.7.2.1.8 |
vtlInitiator OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.2.8 |
vtlInitiatorTableA table containing entries of VtlInitiatorEntry. SEQUENCE OF VtlInitiatorEntry .1.3.6.1.4.1.19746.1.11.2.8.1 |
vtlInitiatorEntryvtlInitiatorTable Row Description VtlInitiatorEntry .1.3.6.1.4.1.19746.1.11.2.8.1.1 |
vtlInitiatorIndexVTL Initiator index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.11.2.8.1.1.1 |
vtlInitiatorNameVTL Initiator Namero DDMibTableString32TC .1.3.6.1.4.1.19746.1.11.2.8.1.1.2 |
vtlInitiatorStatusVTL Initiator Statusro DDMibTableString32TC .1.3.6.1.4.1.19746.1.11.2.8.1.1.3 |
vtlInitiatorGroupVTL Initiator Groupro DDMibTableString32TC .1.3.6.1.4.1.19746.1.11.2.8.1.1.4 |
vtlInitiatorWWNNVTL Initiator WWNNro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.8.1.1.5 |
vtlInitiatorWWPNVTL Initiator WWPNro DDMibTableString64TC .1.3.6.1.4.1.19746.1.11.2.8.1.1.6 |
vtlInitiatorPortVTL Initiator Portro DDMibTableString32TC .1.3.6.1.4.1.19746.1.11.2.8.1.1.7 |
vtlStats OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.11.3 |
vtlStatsTableThis table contains detailed statistical information about the individual VTL Ports on a Data Domain System. It includes the count of Control Commands, Write Commands, and Read Commands. The amount of data In, and Out. The count of Link Failures, LIP count, Sync Losses, Signal Losses, Prim Seq Proto Errors, Invalid Tx Words, and Invalid CRCs. It is comprised of entries of VtlStatsEntry. SEQUENCE OF VtlStatsEntry .1.3.6.1.4.1.19746.1.11.3.1 |
vtlStatsEntryvtlStatsTable Row Description VtlStatsEntry .1.3.6.1.4.1.19746.1.11.3.1.1 |
vtlStatsIndexVTL Stats Index. The index of the VTL Per-Port Statistical entry. VtlStatsIndexTC .1.3.6.1.4.1.19746.1.11.3.1.1.1 |
vtlStatsPortVTL Stats Port. The physical VTL port number.ro VtlStatsPortTC .1.3.6.1.4.1.19746.1.11.3.1.1.2 |
vtlStatsConrolCommandsVTL Stats Control Commands. The number of non read/write commands.ro VtlStatsConrolCommandsTC .1.3.6.1.4.1.19746.1.11.3.1.1.3 |
vtlStatsWriteCommandsVTL Stats Write Commands. The number of WRITE commands.ro VtlStatsWriteCommandsTC .1.3.6.1.4.1.19746.1.11.3.1.1.4 |
vtlStatsReadCommandsVTL Stats Read Commands. The number of READ commands.ro VtlStatsReadCommandsTC .1.3.6.1.4.1.19746.1.11.3.1.1.5 |
vtlStatsInVTL Stats In. The number of megabytes written to the specific port.ro VtlStatsInTC .1.3.6.1.4.1.19746.1.11.3.1.1.6 |
vtlStatsOutVTL Stats Out. The number of megabytes read from the specific port.ro VtlStatsOutTC .1.3.6.1.4.1.19746.1.11.3.1.1.7 |
vtlStatsLinkFailuresVTL Stats Link Failures. The count of Link Failures.ro VtlStatsLinkFailuresTC .1.3.6.1.4.1.19746.1.11.3.1.1.8 |
vtlStatsLIPCountVTL Stats LIP Count. The number of LIPs.ro VtlStatsLIPCountTC .1.3.6.1.4.1.19746.1.11.3.1.1.9 |
vtlStatsSyncLossesVTL Stats Sync Losses. The number of times sync loss was detected.ro VtlStatsSyncLossesTC .1.3.6.1.4.1.19746.1.11.3.1.1.10 |
vtlStatsSignalLossesVTL Stats Signal Losses. The number of times loss of signal was detected.ro VtlStatsSignalLossesTC .1.3.6.1.4.1.19746.1.11.3.1.1.11 |
vtlStatsPrimSeqProtoErrorsVTL Stats Prim Seq Proto Errors. The count of errors in the Primitive Sequence Protocol.ro VtlStatsPrimSeqProtoErrorsTC .1.3.6.1.4.1.19746.1.11.3.1.1.12 |
vtlStatsInvalidTxWordsVTL Stats Invalid Tx Words. The number of invalid TX words.ro VtlStatsInvalidTxWordsTC .1.3.6.1.4.1.19746.1.11.3.1.1.13 |
vtlStatsInvalidCRCsVTL Stats Invalid CRCs. The number of frames received with bad CRC.ro VtlStatsInvalidCRCsTC .1.3.6.1.4.1.19746.1.11.3.1.1.14 |
ddboost OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12 |
ddboostProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.1 |
ddboostStatusThe status of the DDBoost interface group on a DD system.ro DDboostStatusTC .1.3.6.1.4.1.19746.1.12.1.1 |
ddboostUserDDBoost User.rodeprecated DDboostUserTC .1.3.6.1.4.1.19746.1.12.1.2 |
ddboostIfGroupStatusDDBoost IfGroup Status.rodeprecated DDMibStatusTC .1.3.6.1.4.1.19746.1.12.1.3 |
ddboostUserTableThis table contains information about DDBoost users. SEQUENCE OF DdboostUserEntry .1.3.6.1.4.1.19746.1.12.1.4 |
ddboostUserEntryddboostUserTable Row Entry. DdboostUserEntry .1.3.6.1.4.1.19746.1.12.1.4.1 |
ddboostUserIdxDDBoost users table index. DDboostStatsIndexTC .1.3.6.1.4.1.19746.1.12.1.4.1.1 |
ddboostUserNameThe name of a Ddboost user.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.12.1.4.1.2 |
ddboostUserDefaultTenantUnitThe default tenant unit that is associated with a specific DDBoost user.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.12.1.4.1.3 |
ddboostIfGroupTableDDBoost IfGroup table containing interface group information. SEQUENCE OF DdboostIfGroupEntry .1.3.6.1.4.1.19746.1.12.1.5 |
ddboostIfGroupEntryddboostIfGroupTable Row Entry. DdboostIfGroupEntry .1.3.6.1.4.1.19746.1.12.1.5.1 |
ddboostIfGroupIdxDDBoost IfGroup table index. DDboostStatsIndexTC .1.3.6.1.4.1.19746.1.12.1.5.1.1 |
ddboostIfGroupNameThe name of DDBoost IfGroup.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.12.1.5.1.2 |
ddboostIfGroupCurrentStatusThe status of a DDBoost IfGroup. Possible values are: 'enabled' or 'disabled'.ro DDMibStatusTC .1.3.6.1.4.1.19746.1.12.1.5.1.3 |
ddboostStats OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.2 |
ddboostStatsTableDDBOOST stats table containing byte statistics information for DDBOOST SEQUENCE OF DdboostStatsEntry .1.3.6.1.4.1.19746.1.12.2.1 |
ddboostStatsEntryddboostStatsTable Row Entry DdboostStatsEntry .1.3.6.1.4.1.19746.1.12.2.1.1 |
ddboostStatsIndexddboost Stats Table index DDboostStatsIndexTC .1.3.6.1.4.1.19746.1.12.2.1.1.1 |
ddboostPreCompKBytesPerSecondNumber of pre-compressed (logical) bytes received per secondro KBytesPerSecond .1.3.6.1.4.1.19746.1.12.2.1.1.2 |
ddboostPostCompKBytesPerSecondnumber of pddboost local compression bytes received per secondro KBytesPerSecond .1.3.6.1.4.1.19746.1.12.2.1.1.3 |
ddboostNetworkKBytesPerSecondNumber of physical network bytes received per secondro KBytesPerSecond .1.3.6.1.4.1.19746.1.12.2.1.1.4 |
ddboostReadKBytesPerSecondNumber of bytes read per secondro KBytesPerSecond .1.3.6.1.4.1.19746.1.12.2.1.1.5 |
ddboostStatsBackupConnNumber of backup connectionsro Counter64 .1.3.6.1.4.1.19746.1.12.2.1.1.6 |
ddboostStatsRestoreConnNumber of restore connectionsro Counter64 .1.3.6.1.4.1.19746.1.12.2.1.1.7 |
ddboostStatsImageCreatesCountNumber of image createsro Counter64 .1.3.6.1.4.1.19746.1.12.2.1.1.8 |
ddboostStatsImageCreatesErrorsNumber of image creates errorsro Counter64 .1.3.6.1.4.1.19746.1.12.2.1.1.9 |
ddboostStatsImageDeletesCountNumber of image deletesro Counter64 .1.3.6.1.4.1.19746.1.12.2.1.1.10 |
ddboostStatsImageDeletesErrorsNumber of image deletes errorsro Counter64 .1.3.6.1.4.1.19746.1.12.2.1.1.11 |
ddboostStatsPrecompBytesReceivedNumber of pre-compressed (logical) bytes receivedro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.2.1.1.12 |
ddboostStatsBytesAfterFilteringNumber of bytes after filteringro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.2.1.1.13 |
ddboostStatsBytesAfterLcNumber of bytes after local compressionro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.2.1.1.14 |
ddboostStatsNetworkBytesReceivedNumber of network bytes receivedro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.2.1.1.15 |
ddboostStatsCompressionRatioCompression ratioro DDMibTableString32TC .1.3.6.1.4.1.19746.1.12.2.1.1.16 |
ddboostStatsTotalBytesReadCountTotal bytes read countro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.2.1.1.17 |
ddboostStatsTotalBytesReadErrorsTotal bytes read errorsro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.2.1.1.18 |
ddboostConnections OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.3 |
ddboostConnectionsTableDDBOOST connections table information for DDBOOST Client Connections SEQUENCE OF DdboostConnectionsEntry .1.3.6.1.4.1.19746.1.12.3.1 |
ddboostConnectionsEntryddboostConnectionsTable Row Entry DdboostConnectionsEntry .1.3.6.1.4.1.19746.1.12.3.1.1 |
ddboostConnectionsIndexddboost connections Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.3.1.1.1 |
ddboostInterfaceDDboost Interface Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.3.1.1.2 |
ddboostifGroupMemberIf Member of ifGroupro DDMibTableEnabledTC .1.3.6.1.4.1.19746.1.12.3.1.1.3 |
ddboostBackupConnectionsDDboost backup connectionsro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.3.1.1.4 |
ddboostRestoreConnectionsDDboost Restore connectionsro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.3.1.1.5 |
ddboostControlConnectionsDDboost control connectionsro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.3.1.1.6 |
ddboostTotalConnectionsDDboost Total connectionsro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.3.1.1.7 |
ddboostStorageUnit OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.4 |
ddboostStorageUnitTableDDBOOST StorageUnit table information for DDBOOST Storage Units SEQUENCE OF DdboostStorageUnitEntry .1.3.6.1.4.1.19746.1.12.4.1 |
ddboostStorageUnitEntryddboostStorageUnitTable Row Entry DdboostStorageUnitEntry .1.3.6.1.4.1.19746.1.12.4.1.1 |
ddboostStorageUnitIndexddboost StorageUnit Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.4.1.1.1 |
ddboostStorageUnitNameDDboost Storage Unit Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.4.1.1.2 |
ddboostStorageUnitBytesDDboost Storage Unit Original MiB.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.4.1.1.3 |
ddboostStorageUnitGlobalCompDDboost Storage Unit Globally Compressed MiB.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.4.1.1.4 |
ddboostStorageUnitLocalCompDDboost Storage Unit Locally Compressed MiB.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.4.1.1.5 |
ddboostStorageUnitMetaDataDDboost Storage Unit Meta Data MiB.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.4.1.1.6 |
ddboostStorageUnitStatusDDboost Storage Unit Status.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.4.1.1.7 |
ddboostStorageUnitPreCompDDboost Storage Unit Pre-Compression Rate.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.4.1.1.8 |
ddboostStorageUnitUserThe User of the DDboost Storage Unit.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.4.1.1.9 |
ddboostStorageUnitReportPhysicalSizeDDboost Storage Unit Report Physical Size.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.4.1.1.10 |
ddboostFileReplicationStats OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.5 |
ddboostFileReplicationStatsTableDDBOOST FileReplicationStats table contains information for File Replication Stats SEQUENCE OF DdboostFileReplicationStatsEntry .1.3.6.1.4.1.19746.1.12.5.1 |
ddboostFileReplicationStatsEntryddboostFileReplicationStatsTable Row Entry DdboostFileReplicationStatsEntry .1.3.6.1.4.1.19746.1.12.5.1.1 |
ddboostFileReplStatsIndexddboost FileReplicationStats Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.5.1.1.1 |
ddboostFileReplStatsDirectionDDboost File Replication Directionro DDMibTableString32TC .1.3.6.1.4.1.19746.1.12.5.1.1.2 |
ddboostFileReplStatsNetworkSentDDBoost File Replication Network Bytes Sentro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.5.1.1.3 |
ddboostFileReplStatsPreCompSentDDBoost File Replication Pre Compressed bytes sentro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.5.1.1.4 |
ddboostFileReplStatsFilteredDDBoost File Replication Bytes after Filteringro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.5.1.1.5 |
ddboostFileReplStatsLowBWOptDDBoost File Replication Bytes after Low Bandwidth optimizationro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.5.1.1.6 |
ddboostFileReplStatsLocalCompDDBoost File Replication Bytes after local compressionro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.5.1.1.7 |
ddboostFileReplStatsCompRatioDDboost File Replication Compressed Ratioro DDMibTableString32TC .1.3.6.1.4.1.19746.1.12.5.1.1.8 |
ddboostFileReplicationHistory OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.6 |
ddboostFileReplicationHistoryTableDDBOOST FileReplicationHistory table contains information for File Replication History SEQUENCE OF DdboostFileReplicationHistoryEntry .1.3.6.1.4.1.19746.1.12.6.1 |
ddboostFileReplicationHistoryEntryddboostFileReplicationHistoryTable Row Entry DdboostFileReplicationHistoryEntry .1.3.6.1.4.1.19746.1.12.6.1.1 |
ddboostFileReplHistoryIndexddboost FileReplicationHistory Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.6.1.1.1 |
ddboostFileReplHistoryDirectionDDboost File ReplHistory History Directionro DDMibTableString32TC .1.3.6.1.4.1.19746.1.12.6.1.1.2 |
ddboostFileReplHistoryNetworkDDBoost File Replication History Network KBytes Sentro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.6.1.1.3 |
ddboostFileReplHistoryPreCompDDBoost File ReplHistory Pre Compressed Kbytes sentro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.6.1.1.4 |
ddboostFileReplHistoryPostCompDDBoost File ReplHistory Post Compressed KBytesro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.6.1.1.5 |
ddboostFileReplHistoryLowBWOptDDBoost File ReplHistory KBytes after Low Bandwidth optimizationro DDMibTableString32TC .1.3.6.1.4.1.19746.1.12.6.1.1.6 |
ddboostFileReplHistoryErrorsDDBoost File ReplHistory Errorsro DDMibTrafficBytesTC .1.3.6.1.4.1.19746.1.12.6.1.1.7 |
ddboostFileReplHistoryDateDDboost File ReplHistory Datero DDMibDateTC .1.3.6.1.4.1.19746.1.12.6.1.1.8 |
ddboostFileReplHistoryTimeDDboost File ReplHistory Timero DDMibDateTC .1.3.6.1.4.1.19746.1.12.6.1.1.9 |
ddboostIfGroupConfig OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.7 |
ddboostIfGroupConfigTableDDBOOST IfGroupConfig table information for DDBOOST ifGroup Configuration SEQUENCE OF DdboostIfGroupConfigEntry .1.3.6.1.4.1.19746.1.12.7.1 |
ddboostIfGroupConfigEntryddboostIfGroupConfigTable Row Entry DdboostIfGroupConfigEntry .1.3.6.1.4.1.19746.1.12.7.1.1 |
ddboostIfGroupConfigIndexddboost IfGroupConfig Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.7.1.1.1 |
ddboostIfGroupInterfaceDDboost ifGroup Interface Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.7.1.1.2 |
ddboostAccessClients OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.8 |
ddboostAccessClientsTableDDBOOST AccessClients table information for DDBOOST Access Client Configuration SEQUENCE OF DdboostAccessClientsEntry .1.3.6.1.4.1.19746.1.12.8.1 |
ddboostAccessClientsEntryddboostAccessClientsTable Row Entry DdboostAccessClientsEntry .1.3.6.1.4.1.19746.1.12.8.1.1 |
ddboostAccessClientsIndexddboost AccessClients Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.8.1.1.1 |
ddboostAccessClientsNameThe DDboost Access clients Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.8.1.1.2 |
ddboostAccessClientsEncryStrengthThe encryption strength that the DDboost Access client is using, possible values are none, medium and highro DdboostAccessClientsEncryStrengthTC .1.3.6.1.4.1.19746.1.12.8.1.1.3 |
ddboostAccessClientsAuthModeThe Authentication mode that the DDboost Access client is using, possible values are none, one-way, two-way and anonymousro DdboostAccessClientsAuthModeTC .1.3.6.1.4.1.19746.1.12.8.1.1.4 |
ddboostOptions OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.9 |
ddboostOptionsTableDDBOOST Options table SEQUENCE OF DdboostOptionsEntry .1.3.6.1.4.1.19746.1.12.9.1 |
ddboostOptionsEntryddboostOptionsTable Row Entry DdboostOptionsEntry .1.3.6.1.4.1.19746.1.12.9.1.1 |
ddboostOptionsIndexddboost Option Table index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.12.9.1.1.1 |
ddboostOptionsNameDDboost Option Value Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.12.9.1.1.2 |
ddboostOptionsStatusDDboost Option Status Enabled/Disabledro DDMibStatusTC .1.3.6.1.4.1.19746.1.12.9.1.1.3 |
ddboostFileReplicationPerformance OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.12.10 |
ddboostFileRepliPerfInPreCompKBPerSecDDBOOST File Replication Performance Inbound pre-comp kilobytes per secondro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.10.1 |
ddboostFileRepliPerfInNetworkKBPerSecDDBOOST File Replication Performance Inbound network kilobytes per secondro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.10.2 |
ddboostFileRepliPerfOutPreCompKBPerSecDDBOOST File Replication Performance Outbound pre-comp kilobytes per secondro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.10.3 |
ddboostFileRepliPerfOutNetworkKBPerSecDDBOOST File Replication Performance Outbound network kilobytes per secondro DDMibInteger32TC .1.3.6.1.4.1.19746.1.12.10.4 |
dataDomainSystem OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13 |
systemProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13.1 |
systemSerialNumberSerial Number of the Systemro SystemSerialNumberTC .1.3.6.1.4.1.19746.1.13.1.1 |
systemCurrentTimeDDR system's current timero DDMibTimeStampTC .1.3.6.1.4.1.19746.1.13.1.2 |
systemVersionDD Version of the Systemro DDMibVersionTC .1.3.6.1.4.1.19746.1.13.1.3 |
systemModelNumberModel Number of the Systemro DDMibTableString64TC .1.3.6.1.4.1.19746.1.13.1.4 |
systemTimeZoneNameDDR system's time zone namero SystemTimeZoneNameTC .1.3.6.1.4.1.19746.1.13.1.5 |
sysNotesCustomer defined notes associated with this DD System.rw SystemNotesTC .1.3.6.1.4.1.19746.1.13.1.6 |
systemHardware OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13.2 |
systemHardwareTableA table containing entries of SystemHardwareEntry. SEQUENCE OF SystemHardwareEntry .1.3.6.1.4.1.19746.1.13.2.1 |
systemHardwareEntrysystemHardwareTable Row Description SystemHardwareEntry .1.3.6.1.4.1.19746.1.13.2.1.1 |
systemHardwareIndexSystem Hardware Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.13.2.1.1.1 |
systemHardwareSlotSystem Hardware Slotrodeprecated DDMibInteger32TC .1.3.6.1.4.1.19746.1.13.2.1.1.2 |
systemHardwareVendorSlot Device Vendorro DDMibTableString64TC .1.3.6.1.4.1.19746.1.13.2.1.1.3 |
systemHardwareDeviceSlot Devicero DDMibTableString128TC .1.3.6.1.4.1.19746.1.13.2.1.1.4 |
systemHardwarePortsSlot Portsro DDMibTableString128TC .1.3.6.1.4.1.19746.1.13.2.1.1.5 |
systemHardwareSlotNameSystem Hardware Slot Namero DisplayString .1.3.6.1.4.1.19746.1.13.2.1.1.6 |
systemPorts OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13.3 |
systemPortsTableA table containing entries of SystemPortsEntry. SEQUENCE OF SystemPortsEntry .1.3.6.1.4.1.19746.1.13.3.1 |
systemPortsEntrysystemPortsTable Row Description SystemPortsEntry .1.3.6.1.4.1.19746.1.13.3.1.1 |
systemPortsIndexSystem Ports Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.13.3.1.1.1 |
systemPortsPortSystem Ports Port namero DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.3.1.1.2 |
systemPortsConnectionTypePort LinkSpeed ConnectionTypero DDMibTableString64TC .1.3.6.1.4.1.19746.1.13.3.1.1.3 |
systemPortsLinkSpeedsystem Port LinkSpeedro DDMibTableString128TC .1.3.6.1.4.1.19746.1.13.3.1.1.4 |
systemPortsFirmwaresystem ports firmware versionro DDMibTableString128TC .1.3.6.1.4.1.19746.1.13.3.1.1.5 |
systemPortsHardwareAddressSystem Port Hardware Address.ro DDMibTableString64TC .1.3.6.1.4.1.19746.1.13.3.1.1.6 |
systemLicense OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13.4 |
systemLicenseTableA table containing entries of SystemLicenseEntry. SEQUENCE OF SystemLicenseEntry .1.3.6.1.4.1.19746.1.13.4.1 |
systemLicenseEntrysystemLicenseTable Row Description SystemLicenseEntry .1.3.6.1.4.1.19746.1.13.4.1.1 |
systemLicenseIndexSystem License Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.13.4.1.1.1 |
systemLicenseKeySystem License Keyro DDMibTableString256TC .1.3.6.1.4.1.19746.1.13.4.1.1.2 |
systemLicenseFeatureFeature for the licensero DDMibTableString64TC .1.3.6.1.4.1.19746.1.13.4.1.1.3 |
systemCapacityLicense OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13.4.2 |
systemCapacityLicenseTableA table containing entries of systemCapacityLicenseEntry. SEQUENCE OF SystemCapacityLicenseEntry .1.3.6.1.4.1.19746.1.13.4.2.1 |
systemCapacityLicenseEntrysystemCapacityLicenseTable Row Description SystemCapacityLicenseEntry .1.3.6.1.4.1.19746.1.13.4.2.1.1 |
systemCapacityLicenseIndexsystemCapacity License Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.13.4.2.1.1.1 |
systemCapacityLicenseKeysystemCapacity License Keyro DDMibTableString256TC .1.3.6.1.4.1.19746.1.13.4.2.1.1.2 |
systemCapacityLicenseFeatureCapacity Feature for the licensero DDMibTableString64TC .1.3.6.1.4.1.19746.1.13.4.2.1.1.3 |
systemCapacityLicenseModelModel for Feature of the licensero DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.4.2.1.1.4 |
systemCapacityLicenseCapacityCapacity of the modelro DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.4.2.1.1.5 |
systemUser OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.13.5 |
systemUserTableA table containing entries of SystemUsers. SEQUENCE OF SystemUserEntry .1.3.6.1.4.1.19746.1.13.5.1 |
systemUserEntrySystemUserTable Row Description SystemUserEntry .1.3.6.1.4.1.19746.1.13.5.1.1 |
systemUserIndexSystemUser Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.13.5.1.1.1 |
systemUserNameSystemUser Namero DDMibTableString128TC .1.3.6.1.4.1.19746.1.13.5.1.1.2 |
systemUserUIDSystemUser UIDro DDMibInteger32TC .1.3.6.1.4.1.19746.1.13.5.1.1.3 |
systemUserRoleSystemUser Rolero DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.5.1.1.4 |
systemUserStatusSystemUsers Statusro DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.5.1.1.5 |
systemActiveUserTableA table containing entries of SystemActiveUsers. SEQUENCE OF SystemActiveUserEntry .1.3.6.1.4.1.19746.1.13.5.2 |
systemActiveUserEntrySystemActiveUserTable Row Description SystemActiveUserEntry .1.3.6.1.4.1.19746.1.13.5.2.1 |
systemActiveUserIndexSystemActiveUser Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.13.5.2.1.1 |
systemActiveUserNameSystemActiveUser Namero DDMibTableString128TC .1.3.6.1.4.1.19746.1.13.5.2.1.2 |
systemActiveUserIdleTimeSystemActiveUser idle timero DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.5.2.1.3 |
systemActiveUserLoginTimeSystemActiveUser login timero DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.5.2.1.4 |
systemActiveUserLoginFromSystemActiveUser login fromro DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.5.2.1.5 |
systemActiveUserTtySystemActiveUsers Ttyro DDMibTableString32TC .1.3.6.1.4.1.19746.1.13.5.2.1.6 |
art OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.14 |
artConfig OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.14.1 |
artConfigTableA table containing entries of artConfigEntry. SEQUENCE OF ArtConfigEntry .1.3.6.1.4.1.19746.1.14.1.1 |
artConfigEntryartConfigTable Row Description ArtConfigEntry .1.3.6.1.4.1.19746.1.14.1.1.1 |
artConfigIndexart Config index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.14.1.1.1.1 |
artConfigStatusart Config Statusro DDMibTableEnabledTC .1.3.6.1.4.1.19746.1.14.1.1.1.2 |
artConfigMigrationScheduleart Config Migration Schedulero DDMibTableString128TC .1.3.6.1.4.1.19746.1.14.1.1.1.3 |
artConfigDefaultAgeart Config Default Age threshold migration policyro DDMibInteger32TC .1.3.6.1.4.1.19746.1.14.1.1.1.4 |
artConfigFileSystemCleanart Config file System Clean Requiredro DDMibTableEnabledTC .1.3.6.1.4.1.19746.1.14.1.1.1.5 |
artConfigCompressionart Config local compressionro DDMibTableString32TC .1.3.6.1.4.1.19746.1.14.1.1.1.6 |
artMigrationSchedule OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.14.2 |
artMigrationScheduleTableA table containing entries of artMigrationScheduleEntry. SEQUENCE OF ArtMigrationScheduleEntry .1.3.6.1.4.1.19746.1.14.2.1 |
artMigrationScheduleEntryartMigrationScheduleTable Row Description ArtMigrationScheduleEntry .1.3.6.1.4.1.19746.1.14.2.1.1 |
artMigrationScheduleIndexart MigrationScheduleindex DDMibTableIndexTC .1.3.6.1.4.1.19746.1.14.2.1.1.1 |
artMigrationScheduleScheduleart MigrationSchedule Schedulero DDMibTableString512TC .1.3.6.1.4.1.19746.1.14.2.1.1.2 |
artMigrationScheduleStatusart MigrationSchedule Statusro DDMibStatusTC .1.3.6.1.4.1.19746.1.14.2.1.1.3 |
artMigrationPolicy OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.14.3 |
artMigrationPolicyTableA table containing entries of artMigrationPolicyEntry. SEQUENCE OF ArtMigrationPolicyEntry .1.3.6.1.4.1.19746.1.14.3.1 |
artMigrationPolicyEntryartMigrationPolicyTable Row Description ArtMigrationPolicyEntry .1.3.6.1.4.1.19746.1.14.3.1.1 |
artMigrationPolicyIndexart MigrationPolicy index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.14.3.1.1.1 |
artMigrationPolicyMtreeNameart MigrationPolicy Mtree Namero DDMibTableString256TC .1.3.6.1.4.1.19746.1.14.3.1.1.2 |
artMigrationPolicyDefaultAgeart MigrationPolicy Default Agero DDMibInteger32TC .1.3.6.1.4.1.19746.1.14.3.1.1.3 |
mtree OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.15 |
mtreeCompression OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.15.1 |
mtreeCompressionTableA table containing entries of mtreeCompressionEntry. SEQUENCE OF MtreeCompressionEntry .1.3.6.1.4.1.19746.1.15.1.1 |
mtreeCompressionEntrymtreeCompressionTable Row Description MtreeCompressionEntry .1.3.6.1.4.1.19746.1.15.1.1.1 |
mtreeCompressionIndexmtree Compression index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.15.1.1.1.1 |
mtreeCompressionMtreePathmtree Compression Mtree Pathro DDMibTableString512TC .1.3.6.1.4.1.19746.1.15.1.1.1.2 |
mtreeCompressionPreCompGibmtree Compression Pre comp giga bytesro DDMibTableSizeGibTC .1.3.6.1.4.1.19746.1.15.1.1.1.3 |
mtreeCompressionPostCompGibmtree Compression Post Comp Giga Bytesro DDMibTableSizeGibTC .1.3.6.1.4.1.19746.1.15.1.1.1.4 |
mtreeCompressionGlobalCompFactormtree Compression Global Comp Factorro DDMibCompressionFactorTC .1.3.6.1.4.1.19746.1.15.1.1.1.5 |
mtreeCompressionLocalCompFactormtree Compression Local Comp Factorro DDMibCompressionFactorTC .1.3.6.1.4.1.19746.1.15.1.1.1.6 |
mtreeCompressionPostTotalCompFactormtree Compression Total Comp Factorro DDMibCompressionFactorTC .1.3.6.1.4.1.19746.1.15.1.1.1.7 |
mtreeCompressionTimePeriodmtree Compression Time Periodro DDMibTableString128TC .1.3.6.1.4.1.19746.1.15.1.1.1.8 |
mtreeList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.15.2 |
mtreeListTableA table containing entries of mtreeListEntry. SEQUENCE OF MtreeListEntry .1.3.6.1.4.1.19746.1.15.2.1 |
mtreeListEntrymtreeListTable Row Description MtreeListEntry .1.3.6.1.4.1.19746.1.15.2.1.1 |
mtreeListIndexmtree List index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.15.2.1.1.1 |
mtreeListMtreeNamemtree List Mtree Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.15.2.1.1.2 |
mtreeListPreCompGibmtree List Pre comp giga bytesro DDMibTableSizeGibTC .1.3.6.1.4.1.19746.1.15.2.1.1.3 |
mtreeListStatusmtree List Statusro MtreeListStatusTC .1.3.6.1.4.1.19746.1.15.2.1.1.4 |
mtreeRetentionLock OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.15.4 |
mtreeRetentionLockTableA table containing entries of mtreeRetentionLockEntry. SEQUENCE OF MtreeRetentionLockEntry .1.3.6.1.4.1.19746.1.15.4.1 |
mtreeRetentionLockEntrymtreeRetentionLockTable Row Description MtreeRetentionLockEntry .1.3.6.1.4.1.19746.1.15.4.1.1 |
mtreeRetentionLockIndexmtree RetentionLock index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.15.4.1.1.1 |
mtreeRetentionLockMtreeNamemtree RetentionLock Mtree Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.15.4.1.1.2 |
mtreeRetentionLockStatusmtree RetentionLock Statusro MtreeRetentionLockStatusTC .1.3.6.1.4.1.19746.1.15.4.1.1.3 |
mtreeRetentionLockUUIDmtree RetentionLock UUIDro DDMibTableString32TC .1.3.6.1.4.1.19746.1.15.4.1.1.4 |
mtreeRetentionLockMinRetentionPeriodmtree RetentionLock Minimum Retention Periodro DDMibTableString32TC .1.3.6.1.4.1.19746.1.15.4.1.1.5 |
mtreeRetentionLockMaxRetentionPeriodmtree RetentionLock Maximum Retention Periodro DDMibTableString32TC .1.3.6.1.4.1.19746.1.15.4.1.1.6 |
storage OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.16 |
enclosure OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.17 |
enclosureList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.17.1 |
enclosureListTableA table containing entries of EnclosureListEntry. SEQUENCE OF EnclosureListEntry .1.3.6.1.4.1.19746.1.17.1.1 |
enclosureListEntryenclosure List Row Description EnclosureListEntry .1.3.6.1.4.1.19746.1.17.1.1.1 |
enclosureListIndexenclosure List Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.17.1.1.1.1 |
enclosureListNumenclosure Numberro DDMibInteger32TC .1.3.6.1.4.1.19746.1.17.1.1.1.2 |
enclosureListModelenclosure modelro DDMibTableString64TC .1.3.6.1.4.1.19746.1.17.1.1.1.3 |
enclosureListSerialNumenclosure serial numberro DDMibTableString128TC .1.3.6.1.4.1.19746.1.17.1.1.1.4 |
enclosureListOemNameenclosure oem namero DDMibTableString128TC .1.3.6.1.4.1.19746.1.17.1.1.1.5 |
enclosureListOemValueenclosure oem valuero DDMibTableString128TC .1.3.6.1.4.1.19746.1.17.1.1.1.6 |
enclosureListCapacityenclosure Capacityro DDMibTableString64TC .1.3.6.1.4.1.19746.1.17.1.1.1.7 |
enclosurePack OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.17.2 |
enclosurePackTableA table containing entries of EnclosurePackEntry. SEQUENCE OF EnclosurePackEntry .1.3.6.1.4.1.19746.1.17.2.1 |
enclosurePackEntryenclosure Pack Row Description EnclosurePackEntry .1.3.6.1.4.1.19746.1.17.2.1.1 |
enclosurePackIDPack information for the enclosure. Applicable to enclosures with packs such as ES60, and not for ES20 or ES30.ro DDMibTableIndexTC .1.3.6.1.4.1.19746.1.17.2.1.1.1 |
network OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.18 |
dns OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.18.1 |
dnsTableA table containing entries of dnsEntry. SEQUENCE OF DNSEntry .1.3.6.1.4.1.19746.1.18.1.1 |
dnsEntryDNS Table Row Description DNSEntry .1.3.6.1.4.1.19746.1.18.1.1.1 |
dnsIndexDNS Table Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.18.1.1.1.1 |
dnsServerDNS Serverro DDMibTableString32TC .1.3.6.1.4.1.19746.1.18.1.1.1.2 |
searchDomains OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.18.2 |
searchDomainsTableA table containing entries of searchDomainsEntry. SEQUENCE OF SearchDomainsEntry .1.3.6.1.4.1.19746.1.18.2.1 |
searchDomainsEntrysearchDomains Table Row Description SearchDomainsEntry .1.3.6.1.4.1.19746.1.18.2.1.1 |
searchDomainsIndexsearchDomains Table Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.18.2.1.1.1 |
searchDomainsNamesearchDomains Namero DDMibTableString128TC .1.3.6.1.4.1.19746.1.18.2.1.1.2 |
snmpTrapHosts OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.18.3 |
snmpTrapHostsTableA table containing entries of snmp Trap Hosts. SEQUENCE OF SnmpTrapHostsEntry .1.3.6.1.4.1.19746.1.18.3.1 |
snmpTrapHostsEntrysnmpTrapHosts Table Row Description SnmpTrapHostsEntry .1.3.6.1.4.1.19746.1.18.3.1.1 |
snmpTrapHostsIndexsnmpTrapHosts Table Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.18.3.1.1.1 |
snmpTrapHostsNamesnmp Trap Hosts Namero DDMibTableString256TC .1.3.6.1.4.1.19746.1.18.3.1.1.2 |
snmpTrapHostsVersionsnmp Trap Hosts Versionro DDMibTableString32TC .1.3.6.1.4.1.19746.1.18.3.1.1.3 |
nis OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.18.4 |
nisDomainNIS domainro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.18.4.1 |
nisServersNIS serversro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.18.4.2 |
nisAdminGroupsNIS admin groupsro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.18.4.3 |
nisUserGroupsNIS user groupsro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.18.4.4 |
nisBackupOperatorGroupsNIS backup operator groupsro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.18.4.5 |
nisEnabledNIS enabled or notro DDMibTableEnabledTC .1.3.6.1.4.1.19746.1.18.4.6 |
nisStatusNIS statusro DDMibTableString1024TC .1.3.6.1.4.1.19746.1.18.4.7 |
ddms OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.19 |
managedSystem OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.19.1 |
managedSystemTableA table containing entries of managed systems. SEQUENCE OF ManagedSystemEntry .1.3.6.1.4.1.19746.1.19.1.1 |
managedSystemEntrymanagedSystemTable Row Description ManagedSystemEntry .1.3.6.1.4.1.19746.1.19.1.1.1 |
managedSystemIndexmanaged system Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.19.1.1.1.1 |
managedSystemHostnamemanaged system hostnamero DDMibTableString256TC .1.3.6.1.4.1.19746.1.19.1.1.1.2 |
managedSystemSerialmanaged system serial numberro DDMibTableString32TC .1.3.6.1.4.1.19746.1.19.1.1.1.3 |
managedSystemStatemanaged system statero DDMibTableString32TC .1.3.6.1.4.1.19746.1.19.1.1.1.4 |
managedSystemStatusmanaged system statusro DDMibTableString32TC .1.3.6.1.4.1.19746.1.19.1.1.1.5 |
managedSystemDDOSVersionmanaged system DDOS versionro DDMibTableString32TC .1.3.6.1.4.1.19746.1.19.1.1.1.6 |
managedSystemHDSyncTimemanaged system historial data last sync timero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.1.1.1.7 |
managedSystemCDSyncTimemanaged system system current data last sync timero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.1.1.1.8 |
taskHistory OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.19.2 |
taskHistoryTableA table containing entries of TaskHistoryEntry. SEQUENCE OF TaskHistoryEntry .1.3.6.1.4.1.19746.1.19.2.1 |
taskHistoryEntrytaskHistoryEntry Row Description TaskHistoryEntry .1.3.6.1.4.1.19746.1.19.2.1.1 |
taskHistoryIndexTask History Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.19.2.1.1.1 |
taskHistoryUserTask History Userro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.2 |
taskHistoryIDTask History IDro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.3 |
taskHistoryParentTask History Parentro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.4 |
taskHistoryNameTask History Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.5 |
taskHistoryStateTask History Statero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.6 |
taskHistoryStartTimeTask History Start Timero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.7 |
taskHistoryDurationTask History Durationro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.2.1.1.8 |
taskActive OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.19.3 |
taskActiveTableA table containing entries of TaskActiveEntry. SEQUENCE OF TaskActiveEntry .1.3.6.1.4.1.19746.1.19.3.1 |
taskActiveEntrytaskActiveEntry Row Description TaskActiveEntry .1.3.6.1.4.1.19746.1.19.3.1.1 |
taskActiveIndexTask Active Row index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.19.3.1.1.1 |
taskActiveUserTask Active Userro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.2 |
taskActiveIDTask Active IDro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.3 |
taskActiveParentTask Active Parentro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.4 |
taskActiveNameTask Active Namero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.5 |
taskActiveStateTask Active Statero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.6 |
taskActiveStartTimeTask Active Start Timero DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.7 |
taskActiveDurationTask Active Durationro DDMibTableString64TC .1.3.6.1.4.1.19746.1.19.3.1.1.8 |
smt OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20 |
smtProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.1 |
smtStatusThe status of the Secure Multi-Tenancy (SMT) feature on a DD System, which enables storage consolidation for multiple tenants on the same appliance. Through this feature, data and control paths on the DD System are logically secured, isolated and confined, creating secure and isolated logical partitions for each tenant- unit within the same appliance.ro SmtStatusTC .1.3.6.1.4.1.19746.1.20.1.1 |
tenantUnitList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.2 |
tenantUnitListTableThis table contains information about the tenant-units within a DD System that has the Secure Multi-Tenancy (SMT) feature enabled. It includes the tenant-unit name, the number of tenant specific Management users that have been added, the number of Mtree(s)/ DDBoost Storage Units assigned, and whether Tenant-self-service mode is enabled. SEQUENCE OF TenantUnitListEntry .1.3.6.1.4.1.19746.1.20.2.1 |
tenantUnitListEntryInformation about a tenant-unit within a DD System. TenantUnitListEntry .1.3.6.1.4.1.19746.1.20.2.1.1 |
tenantUnitListIdxThe index of a tenant-unit (SMT management object). This index uniquely identifies the tenant-unit at a given time. DDMibTableIndexTC .1.3.6.1.4.1.19746.1.20.2.1.1.1 |
tenantUnitListNameThe name of a tenant-unit. A tenant-unit name consists of letters, numbers, no special characters and can have a length of 254 characters.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.20.2.1.1.2 |
tenantUnitListNumberOfMgmtUsersThe number of Tenant specific Management users which have been added to a tenant-unit.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.20.2.1.1.3 |
tenantUnitListNumberOfMtreesThe number of Mtree(s) which have been assigned to a tenant-unit.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.20.2.1.1.4 |
tenantUnitListNumberOfDdboostStusThe number of DDBoost Storage Units which have been assigned to a tenant-unit.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.20.2.1.1.5 |
tenantUnitListTenantSelfServiceModeStatus of Tenant Self Service Mode. If enabled, administrative access to each tenant is allowed, so that they can monitor and configure their data protection implementation, within the bounds of their allocated objects and features.ro SmtStatusTC .1.3.6.1.4.1.19746.1.20.2.1.1.6 |
tenantUnitListParentTenantNameThe tenant name that a tenant-unit is associated with.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.20.2.1.1.7 |
tenantUnitListTypeThe Mtree type of a tenant-unit.ro DDMibTableString256TC .1.3.6.1.4.1.19746.1.20.2.1.1.8 |
tenantUnitListSecurityModeThe security mode of a tenant-unit.ro TenantUnitSecurityModeTC .1.3.6.1.4.1.19746.1.20.2.1.1.9 |
tenantUnitListNumberOfMgmtGroupsThe number of Tenant specific Management groups which have been added to a tenant-unit.ro DDMibInteger32TC .1.3.6.1.4.1.19746.1.20.2.1.1.10 |
tenantUnitMgmtUserList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.3 |
tenantUnitMgmtUserListTableThis table contains information about the tenant specific management users that have been added to a tenant-unit. Such users may be limited by their role and scope to operate a limited set of operations only on the objects which are assigned-to/associated with their tenant-units. Tenant specific management users may have limited administrative and management capabilities. SEQUENCE OF TenantUnitMgmtUserListEntry .1.3.6.1.4.1.19746.1.20.3.1 |
tenantUnitMgmtUserListEntryInformation about the management users that have been added to a tenant-unit. TenantUnitMgmtUserListEntry .1.3.6.1.4.1.19746.1.20.3.1.1 |
tenantUnitMgmtUserListUserNameThe name of a management user which has been added to a tenant- unit. Users may be limited by their roles and may have limited administrative and management capabilities. DDMibString96TC .1.3.6.1.4.1.19746.1.20.3.1.1.2 |
tenantUnitMgmtUserListUserRoleThe role of a management user. Roles include tenant-admin and tenant-user.ro TenantUnitMgmtUserListUserRoleTC .1.3.6.1.4.1.19746.1.20.3.1.1.3 |
tenantUnitMtreeList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.4 |
tenantUnitMtreeListTableThis table contains information about the mtree(s) which have been assigned to a tenant-unit. Mtree logical quotas for soft-limit and hard-limit may be imposed on a tenant-unit and will allow provisioning space for each tenant on a DD System. Data access may be contained within the mtrees belonging to an tenant-unit. SEQUENCE OF TenantUnitMtreeListEntry .1.3.6.1.4.1.19746.1.20.4.1 |
tenantUnitMtreeListEntryInformation about an mtree associated with a tenant-unit within a DD System. TenantUnitMtreeListEntry .1.3.6.1.4.1.19746.1.20.4.1.1 |
tenantUnitMtreeListMtreeNameThe name of an mtree that has been assigned to a particular tenant-unit. One tenant-unit (SMT management object) may have multiple mtrees associated with it.ro DDMibString96TC .1.3.6.1.4.1.19746.1.20.4.1.1.2 |
tenantUnitDdboostStuList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.5 |
tenantUnitDdboostStuListTableThis table contains information about the DDBoost Storage Units that have been assigned to a tenant-unit. Logical quotas for soft- limit and hard-limit may be imposed on a tenant-unit and will allow provisioning space for each tenant on a DD System. Data access may be contained within the DDBoost Storage Units belonging to a tenant-unit. SEQUENCE OF TenantUnitDdboostStuListEntry .1.3.6.1.4.1.19746.1.20.5.1 |
tenantUnitDdboostStuListEntryInformation about a DDBoost Storage Unit associated with a tenant- unit. TenantUnitDdboostStuListEntry .1.3.6.1.4.1.19746.1.20.5.1.1 |
tenantUnitDdboostStuListStuNameThe name of a DDBoost Storage Unit associated with a tenant-unit. One tenant-unit (SMT management object) may have multiple DDBoost Storage Units associated with it.ro DDMibString96TC .1.3.6.1.4.1.19746.1.20.5.1.1.2 |
tenantUnitAdminIpInfo OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.6 |
tenantUnitAdminIpInfoTableThis table provides IP address related information about a tenant-unit administrator. SEQUENCE OF TenantUnitAdminIpInfoEntry .1.3.6.1.4.1.19746.1.20.6.1 |
tenantUnitAdminIpInfoEntryAn entry of this table represents one set of IP information about a tenant-unit administrator. TenantUnitAdminIpInfoEntry .1.3.6.1.4.1.19746.1.20.6.1.1 |
tenantUnitAdminIpInfoAddrThe IP address (IPv4/IPv6) of a tenant-unit administrator. DDMibString96TC .1.3.6.1.4.1.19746.1.20.6.1.1.2 |
tenantUnitAdminIpInfoTypeThe IP addresss type of a tenant-unit administrator. Possible values: local or remote.ro DDMibString96TC .1.3.6.1.4.1.19746.1.20.6.1.1.3 |
tenantInfo OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.7 |
tenantInfoTableThis table provides tenant information for the Secure Multi-Tenancy (SMT) feature. SEQUENCE OF TenantInfoEntry .1.3.6.1.4.1.19746.1.20.7.1 |
tenantInfoEntryAn entry represents one instance about a tenant that is configured on DD system. TenantInfoEntry .1.3.6.1.4.1.19746.1.20.7.1.1 |
tenantInfoIdxThe index into this table indentifying a particular tenant object. DDMibTableIndexTC .1.3.6.1.4.1.19746.1.20.7.1.1.1 |
tenantInfoTenantNameThe name of this tenant.ro DDMibString96TC .1.3.6.1.4.1.19746.1.20.7.1.1.2 |
tenantInfoTenantUnitTableThis table provides information about the tenant-unit(s) that are associated with this tenant. SEQUENCE OF TenantInfoTenantUnitEntry .1.3.6.1.4.1.19746.1.20.7.2 |
tenantInfoTenantUnitEntryAn entry represents information about one tenant-unit that is associated with a particular tenant. TenantInfoTenantUnitEntry .1.3.6.1.4.1.19746.1.20.7.2.1 |
tenantInfoTenantUnitNameThe name of tenant-unit that is associated with this tenant.ro DDMibString96TC .1.3.6.1.4.1.19746.1.20.7.2.1.2 |
tenantUnitMgmtGroupList OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.20.8 |
tenantUnitMgmtGroupListTableThis table contains information about the tenant specific management groups that have been added to a tenant-unit. Such groups may be limited by their role and scope to operate a limited set of operations only on the objects which are assigned-to/associated with their tenant-units. Tenant specific management groups may have limited administrative and management capabilities. SEQUENCE OF TenantUnitMgmtGroupListEntry .1.3.6.1.4.1.19746.1.20.8.1 |
tenantUnitMgmtGroupListEntryInformation about the management groups that have been added to a tenant-unit. TenantUnitMgmtGroupListEntry .1.3.6.1.4.1.19746.1.20.8.1.1 |
tenantUnitMgmtGroupListGroupNameThe name of a management group which has been added to a tenant- unit. Groups may be limited by their roles and may have limited administrative and management capabilities. DDMibString96TC .1.3.6.1.4.1.19746.1.20.8.1.1.2 |
tenantUnitMgmtGroupListGroupRoleThe role of a management group. Roles include tenant-admin and tenant-group.ro TenantUnitMgmtUserListUserRoleTC .1.3.6.1.4.1.19746.1.20.8.1.1.3 |
tenantUnitMgmtGroupListGroupTypeThe type of a management group. Types include all, local, ad, nis and ldap.ro TenantUnitMgmtGroupTypeTC .1.3.6.1.4.1.19746.1.20.8.1.1.4 |
quota OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.21 |
quotaProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.21.1 |
quotaCapacityStatusThe status of the quota capacity property on a Data Domain System. If enabled quota limits are enforced and administrators can control the logical space consumed on a per-Mtree basis.ro DDStatusTC .1.3.6.1.4.1.19746.1.21.1.1 |
quotaCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.21.2 |
quotaCapacityTableThis table lists quota capacities for Mtrees and Storage-units. It provides information such as the Mtree name, the Pre-Comp (MiB) size, Soft-Limit (MiB), and Hard-Limit (MiB). It is comprised of entries of quotaCapacityEntry. SEQUENCE OF QuotaCapacityEntry .1.3.6.1.4.1.19746.1.21.2.1 |
quotaCapacityEntryAn entry containing quota information for Mtrees and Storage-units on the DD System. QuotaCapacityEntry .1.3.6.1.4.1.19746.1.21.2.1.1 |
quotaCapacityIndexThe index of an Mtree or Storage-unit. This index uniquely identifies the entry at a given time. DDMibTableIndexTC .1.3.6.1.4.1.19746.1.21.2.1.1.1 |
quotaCapacityMtreeNameThe name of the Mtree or Storage-unit for which quota capacity information is provided.ro DDMibTableString512TC .1.3.6.1.4.1.19746.1.21.2.1.1.2 |
quotaCapacityPreCompMiBThe Pre-Comp (MiB) size of the Mtree or Storage-unit. This is the amount of data written before compression.ro DDMibTableSizeMiBTC .1.3.6.1.4.1.19746.1.21.2.1.1.3 |
quotaCapacitySoftLimitMiBThe Soft-Limit (MiB) quota for the Mtree or Storage-unit. Soft quotas provide only an alert when quota limits are reached, and the backup job is allowed to complete so that the administrator can take corrective actions that are convenient to the organization.ro DDMibTableSizeMiBTC .1.3.6.1.4.1.19746.1.21.2.1.1.4 |
quotaCapacityHardLimitMiBThe Hard-Limit (MiB) quota for the Mtree or Storage-unit. Hard quotas provide a stricter enforcement model than soft quotas by failing the backup jobs or I/O when quota limits are reached.ro DDMibTableSizeMiBTC .1.3.6.1.4.1.19746.1.21.2.1.1.5 |
quotaCapacityTenantUnitThe Tenant-unit to which this Mtree or Storage-unit is assigned. Tenant-units allow for secure and isolated logical partitions within an appliance and are part of the Secure Multi-Tenancy (SMT) feature.ro DDMibTableString512TC .1.3.6.1.4.1.19746.1.21.2.1.1.6 |
highAvailability OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.22 |
highAvailabilityStatus OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.22.1 |
haSystemStatusThe HA/System Statusro DDMibString96TC .1.3.6.1.4.1.19746.1.22.1.1 |
localNodeRoleThe Local Node rolero DDMibString96TC .1.3.6.1.4.1.19746.1.22.1.2 |
localHaStateThe Local HA Statero DDMibString96TC .1.3.6.1.4.1.19746.1.22.1.3 |
peerNodeRoleThe Peer Node Rolero DDMibString96TC .1.3.6.1.4.1.19746.1.22.1.4 |
peerHaStateThe Peer HA Statero DDMibString96TC .1.3.6.1.4.1.19746.1.22.1.5 |
highAvailabilityConfig OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.22.2 |
haConfiguredModeThe HA Configured Modero DDMibString96TC .1.3.6.1.4.1.19746.1.22.2.1 |
haLocalPnodeIdThe HA local pnode idro DDMibInteger32TC .1.3.6.1.4.1.19746.1.22.2.2 |
scsitarget OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23 |
scsitargetProperties OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23.1 |
scsitargetAdminStateScsitarget Admin Statero DDMibString96TC .1.3.6.1.4.1.19746.1.23.1.1 |
scsitargetProcessStateScsitarget Process Statero DDMibString96TC .1.3.6.1.4.1.19746.1.23.1.2 |
scsitargetGroup OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23.2 |
scsitargetGroupTableScsitarget Group Table SEQUENCE OF ScsitargetGroupEntry .1.3.6.1.4.1.19746.1.23.2.1 |
scsitargetGroupEntryscsitargetGroupEntry ScsitargetGroupEntry .1.3.6.1.4.1.19746.1.23.2.1.1 |
scsitargetGroupIndexScsitarget Group Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.2.1.1.1 |
scsitargetGroupNameScsitarget Group Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.2.1.1.2 |
scsitargetGroupServiceScsitarget Group Servicero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.2.1.1.3 |
scsitargetGroupActiveStateScsitarget Group Active Statero DDMibString96TC .1.3.6.1.4.1.19746.1.23.2.1.1.4 |
scsitargetGroupNumInitiatorsScsitarget Group Number of Initiatorsro DDMibInteger32TC .1.3.6.1.4.1.19746.1.23.2.1.1.5 |
scsitargetGroupNumDevicesScsitarget Group Number of Devicesro DDMibInteger32TC .1.3.6.1.4.1.19746.1.23.2.1.1.6 |
scsitargetInitiator OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23.3 |
scsitargetInitiatorTableScsitarget Initiator Table SEQUENCE OF ScsitargetInitiatorEntry .1.3.6.1.4.1.19746.1.23.3.1 |
scsitargetInitiatorEntryscsitargetInitiatorEntry ScsitargetInitiatorEntry .1.3.6.1.4.1.19746.1.23.3.1.1 |
scsitargetInitiatorIndexScsitarget Initiator Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.3.1.1.1 |
scsitargetInitiatorNameScsitarget Initiator Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.2 |
scsitargetInitiatorSystemAddressScsitarget Initiator System Addressro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.3 |
scsitargetInitiatorGroupScsitarget Initiator Groupro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.4 |
scsitargetInitiatorServiceScsitarget Initiator Servicero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.5 |
scsitargetInitiatorAddressMethodScsitarget Initiator Address Methodro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.6 |
scsitargetInitiatorTransportScsitarget Initiator Transportro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.7 |
scsitargetInitiatorFcWwpnScsitarget Initiator Fc Wwpnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.8 |
scsitargetInitiatorFcWwnnScsitarget Initiator Fc Wwnnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.9 |
scsitargetInitiatorFcSymbolicPortNameScsitarget Initiator Fc Symbolic Port Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.1.1.10 |
scsitargetInitiatorEndpTableScsitarget Initiator Endpoint Table SEQUENCE OF ScsitargetInitiatorEndpEntry .1.3.6.1.4.1.19746.1.23.3.2 |
scsitargetInitiatorEndpEntryscsitargetInitiatorEndpEntry ScsitargetInitiatorEndpEntry .1.3.6.1.4.1.19746.1.23.3.2.1 |
scsitargetInitiatorEndpIndexScsitarget Initiator Endpoint Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.3.2.1.1 |
scsitargetInitiatorEndpInitiatorScsitarget Initiatorro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.2.1.2 |
scsitargetInitiatorEndpEndpointScsitarget Initiator Endpointro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.3.2.1.3 |
scsitargetInitiatorEndpStatusScsitarget Initiator Endpoint Statusro DDMibString96TC .1.3.6.1.4.1.19746.1.23.3.2.1.4 |
scsitargetEndpoint OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23.4 |
scsitargetEndpointTableScsitarget Endpoint Table SEQUENCE OF ScsitargetEndpointEntry .1.3.6.1.4.1.19746.1.23.4.1 |
scsitargetEndpointEntryscsitargetEndpointEntry ScsitargetEndpointEntry .1.3.6.1.4.1.19746.1.23.4.1.1 |
scsitargetEndpointIndexScsitarget Endpoint Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.4.1.1.1 |
scsitargetEndpointNameScsitarget Endpoint Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.2 |
scsitargetEndpointCurrentSystemAddressScsitarget Endpoint Current System Addressro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.3 |
scsitargetEndpointPrimarySystemAddressScsitarget Endpoint Primary System Addressro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.4 |
scsitargetEndpointSecondarySystemAddressScsitarget Endpoint Secondary System Addressro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.5 |
scsitargetEndpointEnabledScsitarget Endpoint Enabledro DDStatusTC .1.3.6.1.4.1.19746.1.23.4.1.1.6 |
scsitargetEndpointStatusScsitarget Endpoint Statusro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.7 |
scsitargetEndpointTransportScsitarget Endpoint Transportro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.8 |
scsitargetEndpointFcWwnnScsitarget Endpoint Fc Wwnnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.9 |
scsitargetEndpointFcWwpnScsitarget Endpoint Fc Wwpnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.4.1.1.10 |
scsitargetPort OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23.5 |
scsitargetPortTableScsitarget Port Table SEQUENCE OF ScsitargetPortEntry .1.3.6.1.4.1.19746.1.23.5.1 |
scsitargetPortEntryscsitargetPortEntry ScsitargetPortEntry .1.3.6.1.4.1.19746.1.23.5.1.1 |
scsitargetPortIndexScsitarget Port Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.5.1.1.1 |
scsitargetPortSystemAddressScsitarget Port System Addressro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.2 |
scsitargetPortEnabledScsitarget Port Enabledro DDStatusTC .1.3.6.1.4.1.19746.1.23.5.1.1.3 |
scsitargetPortStatusScsitarget Port Statusro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.4 |
scsitargetPortTransportScsitarget Port Transportro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.5 |
scsitargetPortOperationalStatusScsitarget Port Operational Statusro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.6 |
scsitargetPortFcNpivScsitarget Port Fc Npivro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.7 |
scsitargetPortPortIdScsitarget Port Port Idro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.8 |
scsitargetPortModelScsitarget Port Modelro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.9 |
scsitargetPortFirmwareScsitarget Port Firmwarero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.10 |
scsitargetPortFcBaseWwnnScsitarget Port Fc Base Wwnnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.11 |
scsitargetPortFcBaseWwpnScsitarget Port Fc Base Wwpnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.12 |
scsitargetPortFcCurrentWwnnScsitarget Port Fc Current Wwnnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.13 |
scsitargetPortFcCurrentWwpnScsitarget Port Fc Current Wwpnro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.14 |
scsitargetPortFcp2RetryScsitarget Port Fcp2 Retryro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.15 |
scsitargetPortConnectionTypescsitarget Port Connection Typero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.16 |
scsitargetPortLinkSpeedScsitarget Port Link Speedro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.17 |
scsitargetPortFcTopologyScsitarget Port Fc Topologyro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.1.1.18 |
scsitargetPortEndpTableScsitarget Port Endpoint Table SEQUENCE OF ScsitargetPortEndpEntry .1.3.6.1.4.1.19746.1.23.5.2 |
scsitargetPortEndpEntryscsitargetPortEndpEntry ScsitargetPortEndpEntry .1.3.6.1.4.1.19746.1.23.5.2.1 |
scsitargetPortEndpIndexScsitarget Port Endpoint Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.5.2.1.1 |
scsitargetPortEndpPortScsitarget Portro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.2.1.2 |
scsitargetPortEndpEndpointScsitarget Port Endpointro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.2.1.3 |
scsitargetPortEndpEnabledScsitarget Port Endpoint Enabledro DDStatusTC .1.3.6.1.4.1.19746.1.23.5.2.1.4 |
scsitargetPortEndpStatusScsitarget Port Endpoint Statusro DDMibString96TC .1.3.6.1.4.1.19746.1.23.5.2.1.5 |
scsitargetPortEndpCurrentInstanceScsitarget Port Endpoint Current Instancero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.5.2.1.6 |
scsitargetDevice OBJECT IDENTIFIER .1.3.6.1.4.1.19746.1.23.6 |
scsitargetDeviceTableScsitarget Device Table SEQUENCE OF ScsitargetDeviceEntry .1.3.6.1.4.1.19746.1.23.6.1 |
scsitargetDeviceEntryscsitargetDeviceEntry ScsitargetDeviceEntry .1.3.6.1.4.1.19746.1.23.6.1.1 |
scsitargetDeviceIndexScsitarget Device Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.6.1.1.1 |
scsitargetDeviceNameScsitarget Device Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.1.1.2 |
scsitargetDeviceServiceScsitarget Device Servicero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.1.1.3 |
scsitargetDeviceActiveStateScsitarget Device Active Statero DDMibString96TC .1.3.6.1.4.1.19746.1.23.6.1.1.4 |
scsitargetDeviceAddressScsitarget Device Addressro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.1.1.5 |
scsitargetDeviceGrpTableScsitarget Device Group Table SEQUENCE OF ScsitargetDeviceGrpEntry .1.3.6.1.4.1.19746.1.23.6.2 |
scsitargetDeviceGrpEntryscsitargetDeviceGrpEntry ScsitargetDeviceGrpEntry .1.3.6.1.4.1.19746.1.23.6.2.1 |
scsitargetDeviceGrpIndexScsitarget Device Group Index DDMibTableIndexTC .1.3.6.1.4.1.19746.1.23.6.2.1.1 |
scsitargetDeviceGrpDeviceScsitarget Devicero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.2.1.2 |
scsitargetDeviceGrpGroupNameScsitarget Device Group Namero DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.2.1.3 |
scsitargetDeviceGrpLunScsitarget Device Group Lunro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.2.1.4 |
scsitargetDeviceGrpPrimaryEndpointsScsitarget Device Group Primary Endpointsro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.2.1.5 |
scsitargetDeviceGrpSecondaryEndpointsScsitarget Device Group Secondary Endpointsro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.2.1.6 |
scsitargetDeviceGrpInUseEndpointsScsitarget Device Group In Use Endpointsro DDMibTableString512TC .1.3.6.1.4.1.19746.1.23.6.2.1.7 |
dataDomainMibNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.19746.2 |
dataDomainMibTraps OBJECT IDENTIFIER .1.3.6.1.4.1.19746.2.0 |
powerSupplyFailedAlarmMeaning: Power Supply failed What to do: replace the power supplydeprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.1 |
systemOverheatWarningAlarmMeaning: the temperature reading of one of the thermometers in the Chassis has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.2 |
systemOverheatAlertAlarmMeaning: the temperature reading of one of the thermometers in the Chassis is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the system temperature.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.3 |
systemOverheatShutdownAlarmMeaning: the temperature reading of one of the thermometers in the Chassis has reached or exceeded the 'shutdown' temperature level. The DDR will be shutdown to prevent damage to the system. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: Once the system has been brought back up, after checking for high environment temperatures or other factors which may increase the system temperature, check other environmental values, such as Fan Status, Disk Temperatures, etc...deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.4 |
fanModuleFailedAlarmMeaning: a Fan Module in the enclosure has failed. The index of the fan is given as the index of the alarm. This same index can be looked up in the environmentals table 'fanProperies' for more information about which fan has failed. What to do: replace the fandeprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5 |
nvramFailingAlarmMeaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6 |
fileSystemFailedAlarmMeaning: The File System process on the DDR has had a serious problem and has had to restart. What to do: check the system logs for conditions that may be triggering the failure. Other alarms may also indicate why the File System is having problems.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7 |
fileSpaceMaintenanceAlarmMeaning: DDVAR File System Resource Space is running low for system maintenance activities. The system may not have enough space for the routine system activities to run without error. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.8 |
fileSpacePreWarningAlarmMeaning: A File System Resource space is 80-85% utilized. While not critical, the space usage should be monitored. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: no action is necessary, but the file system should be monitored more closely as it grows more full. Further alarms will be sent when and if the file system space is approaching very full.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.9 |
fileSpaceWarningAlarmMeaning: A File System Resource space is 90% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10 |
fileSpaceSevereAlarmMeaning: A File System Resource space is 95% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.11 |
fileSpaceCriticalAlarmMeaning: A File System Resource space is 100% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.12 |
diskFailedAlarmMeaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk that has failed. What to do: replace the disk.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.14 |
diskOverheatWarningAlarmMeaning: the temperature reading of the indicated disk has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.15 |
diskOverheatAlertAlarmMeaning: the temperature reading of the indicated disk is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it will trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature. If the temperature continues stays at this level or rises, and no other disks are reading this trouble, consider 'failing' the disk, and get a replacement.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.16 |
diskOverheatShutdownAlarmMeaning: the temperature reading of the indicated disk has surpassed the 'shutdown' temperature level. The DDR will be shutdown. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: Boot the DDR and monitor the status and temperatures. If the same disk has continued problems, consider 'failing' it and get a replacement disk.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.17 |
raidReconSevereAlarmMeaning: A raid group is MAX degraded with no reconstruction after less than 71 hours or A disk group is degraded with none max degraded with no reconstruction. This alarm is sent every 1 hour until 71 hours after which raidReconCriticalAlarm or raidReconCriticalShutdown alarm is generated. This can happen due to a disk failing at run-time or boot-time. What to do: while it is still possible that the reconstruction could succeed, the disk should be replaced to ensure data safety.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.18 |
raidReconCriticalAlarmMeaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can happen due to a disk failing at run-time or boot-up. What to do: the disk should be replaced to ensure data safety.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.19 |
raidReconCriticalShutdownAlarmMeaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can happen due to a disk failing at run-time or boot-up. What to do: the disk must be replaced.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.20 |
raidGroupMissingAlarmMeaning: one or more raid groups are missing. What to do: disk may need replacement, or raid administration may be necessary.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.21 |
diskNoSpareAlarmMeaning: there is no spare available for the raid group. What to do: disk may need replacement, or raid administration may be necessary.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.22 |
diskPathAlarmMeaning: multipath configuration is experiencing a problem. The number of paths set up is less than the required number of paths. Disk index is the first disk in the enclosure with multipath. What to do: multipath disk administration may be necessary.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.23 |
diskSASAlarmMeaning: SAS configuration error. Maximum enclosures has been reached, or there is a topology problem. What to do: SAS configuration documentation should be consulted. administration may be necessary.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.24 |
diskSASHBAAlarmMeaning: Unsupported multi-path setting is enabled in the hba firmware. What to do: contact Data Domain support.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.25 |
snapshotFullAlarmMeaning: maximum number of snapshots has been reached. What to do: expire some old snapshots to make room.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.26 |
snapshotHWMAlarmMeaning: the number of snapshots has exceeded a predefined percentage (current 90%) of the maximum. What to do: begin expiring snapshots so that the maximum is not reached.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.27 |
clusterNodeAlarmMeaning: node is not reachable on any network interface. What to do: check status of network and wiring. if that fails, try rebooting the node.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.28 |
clusterInterfaceAlarmMeaning: one interface of the cluster node is down. What to do: check status of network and wiring. if that fails, try rebooting the node.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.29 |
replSyncAlarmMeaning: a replication context is disabled due to nvram loss. What to do: break replication on source and destination, then reconfigure them and run replication sync.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.30 |
systemStartupAlarmMeaning: system has rebooted or started. this does not indicate any abnormal activity. What to do: nothing, unless reboot was triggered by other abnormal conditions, such as temperature, fan or power problems.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.31 |
filesysRelaunchAlarmMeaning: file system has undergone too many relaunches. it is probably unstable. What to do: consult system logs. software or hardware restart may fix the malfunction.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.32 |
filesysDDGCFailedAlarmMeaning: DDGC cleaning process has failed. What to do: consult system logs. software or hardware restart may fix the malfunction.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.33 |
filesysGeneralProblemAlarmMeaning: a general problem has occurred with the file system. What to do: consult system logs. software or hardware restart may fix the malfunction.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.34 |
diskUnsupportedAlarmMeaning: the model of the disk is unsupported by current DD platform. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk. What to do: replace the disk.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.35 |
eventIPMIUnmanageAlarmMeaning: IPMI unmanaged alert detected. What to do: check alert messagedeprecated NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.36 |
controllerUnreachableAlertDescription: This is a GDA event raised by the Master controller when it fails to reach a Worker controller for more than 5 minutes. An unreachable Worker controller implies none of the Worker controller interfaces are pingable from the Master controller. Action: Check the status of network interfaces on both controllers. Check network connectivity between the Master and Worker controller. Make sure all cables are securely connected. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5002 |
controllerIfaceUnreachableAlertDescription: This is a GDA event raised by the Master controller when it fails to reach a particular Worker controller interface for more than 5 minutes. An unreachable interface implies that it is not pingable from its Master controller equivalent interface. Action: Check network interface status on both controllers. Check network connectivity between the Master and Worker controller. Make sure all cables are securely connected. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5003 |
correctableECCLimitReachedDescription: Single bit correctable ECC limit reached. Action: Replace the failed DIMM(s). Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5004 |
uncorrectableECCerrorDescription: Multi bit uncorrectable ECC error. Action: Replace the failed DIMM(s). Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5005 |
legacyChassisTempWarningDescription: Current temperature sensor reading exceeds warning threshold. Action: Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5006 |
legacyChassisTempCriticalDescription: Current temperature sensor reading exceeds critical threshold. Action: Check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5007 |
legacyPowerSupplyWarningDescription: A power supply has failed, is unplugged, or absent. Action: Check power supply cables and LED. Replace with other working power supply. If there are outstanding alerts for all power supplies in an enclosure, the system must be shutdown before replacing any power supply. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5008 |
legacyFanWarningDescription: A fan has failed. Action: Check for any failed fan. If failed, replace with new fan. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5009 |
powerSupplyWarningDescription: A power supply has failed, is unplugged, or absent. Action: Check power supply cables and LED. Replace with other working power supply. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5010 |
fanWarningDescription: A fan has failed or is missing. Action: Check for any failed or missing fan. Reseat the fan. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5011 |
voltageWarningDescription: Voltage sensor reading exceeds warning threshold. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5012 |
powerWarningDescription: Current power consumption reading exceeds warning threshold. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5013 |
correctECCWarningDescription: Memory correctable ECC errors exceed warning threshold. Action: These memory errors are automatically corrected by the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5014 |
processorWarningDescription: Processor status sensor alert. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5016 |
powerUnitWarningDescription: This event is expected after power off, power cycle, or AC power loss event. Action: If this alert is not expected, check power cords and AC power. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5017 |
unCorrectECCWarningDescription: Memory uncorrectable ECC error alert. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5018 |
chassisSensorCriticalDescription: Current sensor reading or state exceeds critical condition. Action: Check the specific alert message for information. Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5020 |
chassisTempWarningDescription: Current temperature sensor reading exceeds warning threshold. Action: Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5021 |
chassisTempCriticalDescription: Current temperature sensor reading exceeds critical threshold. Action: Check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5022 |
cPUFailureWarningDescription: DDOS has detected a fault with the indicated CPU. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5023 |
legacyBMCHangCriticalDescription: While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating. Action: Use CLI or Enterprise Manager to check fan, voltage, and power supply readings. If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC. Wait until all LEDS are off. Reinsert the power cables and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5024 |
bMCHangCriticalDescription: While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating. Action: Use CLI or Enterprise Manager to check fan, voltage, and power supply readings. If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC. Wait until all LEDS are off. Reinsert the power cables and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5025 |
abnormalShutdownDescription: The system has been shutdown by abnormal method, i.e. not by one of the following: 1) Via IPMI chassis control command 2) Via power button 3) Via OS shutdown Action: This alert is expected after loss of AC (main power) event. If this shutdown is not expected and persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5026 |
tooManyRelaunchesDescription: The filesystem has failed to restart after multiple attempts. Backup and restore services are unavailable. Action: Contact your contracted support provider or visit us online at https://support.emc.com to diagnose the failure. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5027 |
filesystemProblemDescription: A problem is preventing the filesystem from running. This usually involves the storage being unavailable. Action: Check disk shelf cabling. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5028 |
dDFSFailedInShutdownDescription: The filesystem shut down encountered an error. This can potentially leave data in the NVRAM which would be normally flushed to the disk. Failed shutdown can leave the filesystem in a state that can prevent certain operations from being performed (i.e. system upgrade, filesys destroy, etc.) and may cause data loss. Action: Re-enable the filesystem and try shutting it down again. If the problem persists, Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5030 |
dDFSNoHeartbeatDescription: Filesystem has encountered an error and is forced to restart. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5034 |
dDFSDiedAfterRebootDescription: The filesystem failed to startup immediately after system reboot. Action: Contact your contracted support provider or visit us online at https://support.emc.com for diagnosis of the cause of failure. No other action required if filesystem successfully restarts. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5036 |
dDFSDiedDescription: The filesystem process failed and is restarting. Action: Contact your contracted support provider or visit us online at https://support.emc.com for diagnosis of the cause of failure. No other action required if filesystem successfully restarts. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5037 |
dDFSRebootedDescription: This is just a notification alert that the system has been rebooted. Action: No action required. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5038 |
dDFSRebootedDisabledDescription: This is a notification alert sent out during system startup following a reboot. The system is rebooted with the filesystem in disabled state. Action: No action is required unless the intent is to have the filesystem enabled. In that case, invoke the 'filesys enable' command. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5039 |
indexRebuildCompleteDescription: The metadata rebuild operation that was started by support has completed. The system is ready for the next action. Action: Contact your contracted support provider or visit us online at https://support.emc.com to perform the next operation on your system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5040 |
historicalDatabaseRecoverErrorDescription: All existing historical data has been lost. Data in the historical database is used for some system reports, but it is not required for proper system functioning. This failure may occur during head swap processing if recovery to create the new head primary historical database from the shelf database files fails or historical database may be corrupted. Action: Contact your contracted support provider or visit us online at https://support.emc.com to debug this problem and possibly attempt recovery of the lost historical data. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5041 |
historicalDatabaseBackupErrorDescription: Historical database backup failed. If the primary historical database fails without a recent backup present, some or all of the historical data can be lost when the primary historical database is restored from its backup and log files. Data in the historical database is used for some system reports, but it is not required for proper system functioning. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5042 |
historicalDatabaseUpgradeErrorDescription: Historical database upgrade failed during software upgrade. New historical data fields will not be saved. Some UI reports might be unavailable, or be missing data. Otherwise, this should not affect the system. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem and upgrade the historical database. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5043 |
historicalDatabasePruneErrorDescription: Historical database pruning failed. Pruning ensures the historical database does not consume more than its allocated disk space. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5044 |
noHistoricalDatabaseErrorDescription: Data in the historical database is used for some system reports, but it is not required for proper system functioning. This failure may occur during head swap processing if recovery to create the new head primary historical database from the shelf database files fails or the database has been corrupted. The system is running without historical database after failing to create a new one. Action: Contact your contracted support provider or visit us online at https://support.emc.com to debug this problem and possibly attempt recovery of the lost historical data. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5045 |
hDTFileTransferFailedDescription: Unable to send historical data update file to Data Domain Management Center. Action: Check DNS settings and network connection between the Data Domain System and Data Domain Management Center. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5046 |
hDTSystemErrorDescription: System Error occurred while sending historical data to Data Domain Management Center. Action: Check configuration and system status, messages logs for indicative problems. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5047 |
dIMMFailureAlertDescription: DIMM failure detected. DDFS can't be enabled. Action: Replace the bad DIMMS. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5048 |
memoryAlertDescription: Current memory is less than configured. DDFS can't be enabled. Action: Check the DIMMS in DDR. Add new DIMMS and/or replace the bad DIMMS. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5049 |
portPathDisabledDescription: A path is disabled. Multipath failover will not work correctly until the port is enabled. Action: Verify all storage cabling is connected correctly. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5050 |
diskPathRedundancyDescription: Since only one HBA controller has been detected, disk path redundancy is lost. Action: If the HBA configuration is correct, disable multipath configuration. Otherwise: 1)Use 'disk multipath status' to examine connection status; 2)Verify all storage cabling is connected correctly; 3)Use 'enclosure' commands to verify that HBA controllers are functional. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5051 |
missingPortConnectionDescription: A port and the attached storage have disappeared. Action: Verify the connection and any external storage connected to the missing port. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5052 |
missingLunPathDescription: The number of active paths to a LUN has changed. Action: If this is due to reconfiguration, verify the topology and disable then re-enable multipath monitoring to reset the monitoring. If not, verify the storage cabling and that all paths are connected. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5053 |
missingDiskPathDescription: The number of active paths to a disk has decreased. Multipath redundancy has been lost unless there are more than one connection paths. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5054 |
missingEnclosurePathDescription: The number of active paths to a disk has decreased. Multipath redundancy has been lost unless there are more than one connection paths. Action: Use 'enclosure' commands to verify that HBAs are functional. If this condition is due to configuration change: verify the topology, and then disable and re-enable disk multipath monitoring to reset connection counts. If not, verify the storage cabling is connected correctly. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5055 |
nvramWarningDescription: DDFS is disabled due to a problem with the NVRAM subsystem. Action: Check for other NVRAM-related alerts and follow the action described in those alerts. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5059 |
nvramBatteryAlertDescription: DD OS detected an NVRAM card Battery Unit hardware fault. Probable causes: 1) Battery charging is disabled, or 2) One or more batteries are not charging. Action: Run CLI command 'system show nvram' to check battery status. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5060 |
nvramErrorAlertDescription: DD OS detected an NVRAM card fault. Probable cause: Excessive correctable errors exceed the warning threshold number. Action: The NVRAM card may need to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5061 |
phyalertDescription: Enclosure slot has been disabled due to continuous discovery caused by a failed drive. Action: Replace the failed drive. Use 'disk rescan' command specifying the disk and enclosure id to re-enable the slot. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5062 |
replProgressThreshholdReachedDescription: Collection replication has not made progress and there is data waiting to be replicated. This means your replica is not up to date. Action: - check the 'replication status' or the GUI for errors - check the replica filesystem - check the network - if problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5063 |
replNeedResyncDescription: Replication will not proceed until this context is resynced. Action: To re-establish replication - Note the context information - break the context - reconfigure contexts on both source and destination - resync context on the source NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5064 |
replLogFullDescription: No data can be written to the filesystem. Too much data remains to be replicated. This can be caused by disabled contexts or slow replication. When the condition is resolved, the filesystem will be writable again. Action: Refer to knowledge base for articles discussing ways to reduce replication lag. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5065 |
replIncompatibleWormDescription: New retention-locked files detected on destination during replication resync. Resync cannot proceed. Action: Break the existing context and resync to a new destination. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5066 |
replDestNotConfiguredDescription: Replication context on the destination is missing or mis-matched. Cannot initialize context. Action: - Check both the source and destination configured context URL pair. The context is identified by the destination URL. - Make sure the destination has a matching configuration for this context. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5067 |
replLagThreshholdReachedDescription: Replication lag threshold has been exceeded. Action: Refer to the knowledge base on ways to resolve the replication lag. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5068 |
sASEnclosureCheckDescription: The number of enclosures connected to the port has exceeded the maximum supported limit. This may cause an unexpected behavior. Action: Reduce the number of enclosures down to the limit for the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5069 |
sASTopologyCheckDescription: Invalid cabling has been detected. This may cause unexpected behavior. Action: Refer to the cabling guide. Verify the connectivity of the SAS enclosures by using command 'enclosure show topology'. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5070 |
sASPortDisabledDescription: Excessive errors have caused this port to be disabled. This could be caused by faulty cables or shelf controllers. Action: Contact your contracted support provider or visit us online at https://support.emc.com . NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5071 |
sSLCertificateCorruptedDescription: The SSL certificate used to establish mutual trust between Data Domain systems is broken. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5072 |
snapshotOver90PercentDescription: Current number of snapshots for an Mtree is at 90% or more of the maximum number of snapshots allowed. Action: Consider expiring existing snapshots of that Mtree with the 'snapshot expire' command or adjusting scheduled snapshot retention periods with the 'snapshot schedule modify' command. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5075 |
snapshotLimitReachedDescription: Data Domain system has a limit on the number of existing snapshots held at once for a single Mtree. Once this limit is reached no more snapshots can be created of that Mtree. Action: Consider expiring existing snapshots of that Mtree with 'snapshot expire' command to make room for newer ones. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5076 |
sNTZMultipleIterationsDescription: Indicates that sanitization will be run in multiple iterations. In the worst case this can take 15-20 days for 280 TBs. It means that the system will not run at full speed for that period of time and that GC will not be run to reclaim space. However, sanitization will also reclaim space back but it might not be as efficient as GC is. Action: Make sure that you have enough space to not run out of space and that you can wait that many days in the worst case. You should have at least 20% of physical space available. Other option is to abort sanitization, delete a bunch of files and try again. You can do this process iteratively until you do not get this alert anymore. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5077 |
coredumpWarningDescription: /ddvar might soon run out of space to save system core dumps. Action: Remove unwanted files from /ddvar to free up some space. Lack of space can result in missing core dumps that will hamper debugging operations. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5078 |
coredumpDisabledDescription: Space in /ddvar is not sufficient enough for saving system core dumps. Action: Remove unwanted files from /ddvar to free up some space. Lack of space can result in missing core dumps that will hamper debugging operations. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5079 |
spaceOver80PercentDescription: Space usage has exceeded 80% of the total capacity. Lack of space can result in missing important logs or loss of file system functionality. Action: If it is in root, contact your contracted support provider or visit us online at https://support.emc.com to free up some space. If it is in /ddvar, remove unwanted files to free up some space. If it is in active tier, remove unwanted files and start file system cleaning or add storage. If it is in archive tier, remove unwanted files or add more archive units to the filesystem. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5080 |
spaceOver90PercentDescription: Space usage has exceeded 90% of the total capacity. Lack of space can result in missing important logs or loss of file system functionality. Action: If it is in root, contact your contracted support provider or visit us online at https://support.emc.com to free up some space. If it is in /ddvar, remove unwanted files to free up some space. If it is in active tier, remove unwanted files and start file system cleaning or add storage. If it is in archive tier, remove unwanted files or add more archive units to the filesystem. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5081 |
diskAccessErrorDescription: A hardware fault has been detected for this drive. The drive or the cabling to it may have a problem. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5082 |
diskFailureDescription: Unable to communicate with a disk. This disk cannot be used at this time. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5083 |
diskTemperatureWarningDescription: The disk temperature has exceeded a specified threshold. If the temperature continues to increase, the system could fail or the system could be shut down. Action: If the temperature is high due to high activity for a short period, it should return to normal in a short time. Verify the environment is at its normal temperature. If not, correct this condition. Check for fan failures and free air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5084 |
diskTemperatureShutdownDescription: One or more disks have exceeded the shut down temperature threshold. The system is shutting down. Action: Verify the environment is at its normal temperature. If not, correct this condition. Check for fan failures and free air flow. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5085 |
unsupportedHardwareSpareSizeDescription: The disk capacity is too small for it to be of any use in the system. Action: Replace with a larger capacity disk. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5086 |
missingDiskGroupDescription: One or more critical disks/LUNs are unavailable. Action: Make sure all storage is securely connected. Look at alert history for any path failures. Check for any core files, a critical layer may be unavailable. Verify that all storage is working and recognized correctly. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5087 |
diskGroupReconstructionNoProgressDescription: One or more disks are failed and the RAID reconstruction is not running. Action: Make sure there is/are spare disk(s) in the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5088 |
diskGroupReconstructionDescription: Two or more disks are failed and the RAID protection is in critical state. If an additional disk fails, there might be permanent loss of data. The system will shut down if the problem is not fixed. Action: Make sure there is/are spare disk(s) in the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5089 |
diskGroupReconstructionShutdownDescription: Two or more disks are failed and the RAID protection is in critical state for over a considerable period of time. If an additional disk fails, there might be permanent loss of data. The system will shut down. Action: Restart the system and make sure there is/are spare disk(s) in the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5090 |
diskGroupReconstructionCriticalDescription: Two or more disks are failed and the RAID protection is in critical state for over a considerable period of time. If an additional disk fails, there might be permanent loss of data. Action: Make sure there is/are spare disk(s) in the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5091 |
diskUnknownDescription: Disk is unknown. Action: Add disk to the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5092 |
lowSparesDescription: Not enough spare disks can be detected for this tier. There may be failed disks or connectivity issues with disks or enclosures. Action: Replace any failed or absent disks. Check enclosure connectivity. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5094 |
unsupportedConfigurationROLDescription: Raid on LUN from 4.8 is no longer supported. Please follow instruction on how to increase usable space in your filesystem. Action: 1) migrate data away 2) do a filesystem destroy 3) add your LUN 4) migrate data back NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5095 |
cpismissingDescription: An archive unit is missing which could result in failure to access files in that unit. Action: - check power connection of each shelf. - check data cables of each shelf. - if a hardware problem is found and fixed, restart the files system and verify that the archive unit is online. - If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5500 |
containerMarkedInvalidDescription: The restorer filesystem has detected a data integrity check failure due to hardware/software problems. There is potential for data loss or corruption and needs immediate attention. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5501 |
smiMrcDescription: BIOS SMI MRC interrupt Action: Check if system memory size has been decreased due to a DIMM has been disabled. If yes, replace the bad DIMM. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5502 |
nvramBatteryLowChargeAlertDescription: The NVRAM battery is charging, but is below the threshold. The filesystem will not start until the battery charge reaches the threshold. Action: Wait for the battery charge to reach threshold. If the battery does not reach threshold within 3 hours, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5508 |
ext3NvlogDisabledDescription: DDOS RAID log is disabled due to a problem with the NVRAM subsystem. Action: Check for other NVRAM-related alerts and follow the action described in those alerts. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5527 |
enclosureMixTypeDescription: An unsupported mix of enclosure models have been detected. For example, a mixture of ES30s and ES20s. Action: Refer to the configuration guide for valid cabling configurations. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5528 |
replPathTooLongDescription: Path is too long Action: Shorten the path. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.5531 |
compromisedEncryptionKeysDescription: Data on disk may be at risk of disclosure. Data encrypted with the compromised keys should be re-encrypted before shipping the disks. One can get the list of compromised keys either from CLI or Enterprise Manager. Action: Start file system cleaning to re-encrypt the affected data. For extended retention systems, run space reclamation to re-encrypt affected data in the archive tier. Note, these operations will take a long time to complete. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6001 |
newEncryptionKeyDescription: Old key is still used for encrypting new data. The file system needs to be restarted to activate the new key. Action: Restart the filesystem. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6002 |
encryptionKeyTableFullDescription: Encryption key table is full. No new keys can be added until some keys are deleted. Action: Free up key table space by deleting an unused key and then add the new key. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6003 |
uncertifiedFirmwareDescription: Firmware version is not compatible with this version of DDOS and may cause unexpected behavior. Action: The firmware must be updated as soon as possible, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6004 |
filesystemNVRAMDataLossDescription: Filesystem cannot be enabled because of NVRAM mismatch. This can happen because of an improper headswap or NVRAM card replacement operation. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6005 |
mtreeQuotaSoftLimitDescription: The Soft Limit Quota for this MTree has been reached. This will not affect the operation of the system and is only a warning. If a Quota Hard Limit is set for this MTree, you are approaching that limit and operations writing data to this MTree may fail if the hard limit is reached. Action: To clear this alert, either raise the quota limits or reduce the data in the MTree by deleting files. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6007 |
mtreeQuotaHardLimitDescription: The Hard Limit Quota for this MTree has been reached. No more data will be written to this MTree. If a backup operation was running, it probably failed and must be restarted after clearing this condition. Action: To clear this alert, either raise the Quota Hard Limit for this MTree, or reduce the data in the MTree by deleting files. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6008 |
interfaceConnectivityDownDescription: Network connectivity on this interface is down. This interface is not pingable and cannot be used to send or receive any data. All data transfers using this interface will fail. Action: Please view the Hardware->Network GUI page, or use the 'net show settings' and 'net show config' CLIs to check the current configuration. Make sure that the cable is securely connected to both endpoints and that the interfaces on both ends are properly configured. Otherwise the cable or network hardware could be faulty and may need to be replaced. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6009 |
interfaceConnectivityIntermittentDescription: Network connectivity on this interface is intermittent. Data may not be sent or received successfully. Data transfers using this interface may experience performance degradation or intermittent failures. Action: Please view the Hardware->Network GUI page, or use the 'net show settings' and 'net show config' CLIs to check the current configuration. Make sure that the cable is securely connected to both endpoints and that the interfaces on both ends are properly configured. Otherwise the cable or network hardware could be faulty and may need to be replaced. If the network is configured properly and the problem still persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6010 |
interfaceMisconfigurationDescription: Network interface configuration problem detected. This may be a result of changing the NIC hardware without reconfiguring the interface. This could indicate an unsupported configuration, network environment or hardware problem. A misconfigured interface can potentially cause connectivity problems on subsequent reboots. Action: Please view the Hardware->Network GUI page, or use 'net show settings', 'net config' and 'net show hardware' to check network configuration. Try to fix the problem by reconfiguring the interface with 'net config'. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6011 |
recoverFromNVRAMFailedDescription: Due to NVRAM issues, filesystem has been disabled in order to maintain data integrity. No backups will run until this problem is resolved. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6013 |
cleaningErrorDescription: Unable to reclaim unused space and this may impact the ability to backup. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6014 |
bMCPartialHangDescription: BMC firmware is not responsive. Action: Use CLI or Enterprise Manager to check fan, voltage, and power supply readings. If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC. Wait until all LEDS are off. Reinsert the power cables and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6015 |
fileMigrationErrorDescription: File migration is suspended until this problem is resolved. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6016 |
unusableHostCertificateDescription: Enterprise Manager will not start up using the imported certificate. However, it will start up using the default self-signed certificate. Following is the list of possible causes of this alert, - the file system is locked - the system passphrase is missing - the imported certificate is corrupted Action: Unlock the file system if it is locked. Enter the system passphrase if it is missing. Delete and reimport the current host certificate if it is corrupted. In all cases, the Enterprise Manager needs to be restarted. If the condition persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6017 |
missingHostCertificateDescription: The imported certificate is missing. However, the Enterprise Manager will start up using the default self-signed certificate. Action: If you want to use your own certificate, import it again. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6018 |
foreignEnclosureDescription: The enclosure is unusable by the filesystem. Storage configuration can not be modified while a foreign device is present. Action: If this is expected as part of a chassis swap or chassis upgrade, proceed with the headswap operation to make the foreign filesystem available. Otherwise contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6019 |
interfaceConnectivityUpAndRunningDescription: Network interface is up and running for a period of time after experiencing instability. Action: No action needed. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6020 |
tcpZeroWindowAlertDescription: The TCP connection is active but data is not being transferred. This may cause other communication failures. Action: Check the remote application that uses this TCP connection. Check the network path between the local and remote systems. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6101 |
insecureEncryptedReplicationDescription: Encrypted replication is configured between this system and the remote host. The remote host is running a DDOS version that does not support a fully secure communication protocol. Unauthorized individuals may be able to intercept and decrypt the replicated data. Action: Upgrade the remote system to a release that supports the desired communication protocol. Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6102 |
nvramHWAlertDescription: The NVRAM card is not in a usable state. The file system cannot be accessed until the fault is corrected or the NVRAM card is replaced. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6504 |
nvramEnvAlertDescription: The temperature sensor on the NVRAM card or the remote battery detected a temperature that is higher than the warning threshold. If there are other environmental alerts, this may indicate a cooling problem where the system is installed. If there are no other environmental alerts, this may indicate a problem with this component. When the temperature is reduced, this alert will clear. Action: Check cooling and airflow around the system unit. Remove any blockage, or ensure the environmental systems are operating correctly, and the environment is at a normal temperature. If there is no problem in the environment, or if only the NVRAM or remote battery are reporting this problem, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6505 |
nvramEventHWAlertDescription: NVRAM firmware detects an NVRAM card hardware fault. Action: The NVRAM card may need to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6506 |
nvramBattAlertDescription: The remote battery for an NVRAM card is not in a usable state. The file system cannot be accessed until the fault is corrected or the NVRAM remote battery is replaced. Action: Check NVRAM battery status. Check the cables between the remote battery and the power source, and between the remote battery and the NVRAM card. If the cables are correctly connected and the problem persists, Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6507 |
nvramCondAlertDescription: The NVRAM battery power or charging has been set as disabled. This condition is either the result of an explicit setting, or indicates a fault in the NVRAM card or battery unit. Action: If the NVRAM battery power was explicitly disabled, enable it using the reverse of the procedure used to disable it. If not, reboot the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6508 |
upgradeFailureDescription: During the upgrade process, there was an error that requires manual intervention. The system is not usable. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6509 |
upgradeCompletedDescription: The DD OS upgrade is completed successfully. The system will be ready to use when the filesystem is enabled. Action: No action required. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6510 |
mailserverErrorDescription: There is a problem communicating with the configured mail server. The system will not be able to send out any email notifications that includes alerts, autosupports and daily summary emails. Action: Make sure that the mail server is configured correctly. Verify the configured mail server by sending out a test email from the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6511 |
invalidNICSlotDescription: Network interface cards must be installed in their designated slots. The network card may not function correctly when installed in the wrong slot. Action: Please make sure that the Network interface card is installed in a valid slot. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6512 |
unsupportedNICDescription: An unsupported network interface card is installed in the system. Having an unsupported card installed in the system can cause unexpected errors. Action: Remove the card from system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6513 |
sASHBAFailureDescription: Storage is no longer accessible through this HBA. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6514 |
sASHBAErrorsDescription: A SAS HBA has detected correctable errors exceeding the warning threshold. This will reduce throughput and may indicate a failing HBA. Action: If this condition persists for more than 24 hours, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6515 |
unsupportedSASDeviceDescription: A SAS HBA has reported a device that is not recognized. This device is not usable and may adversely affect the system. Action: Identify the device and remove it from the topology. If you believe it is a supported device, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6516 |
fanFaultDescription: A hardware fault has been detected in an enclosure cooling fan. This may allow the enclosure to overheat. Action: The fan must be replaced. Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6517 |
powerSupplyInputFaultDescription: A power loss has been detected in an enclosure power supply. This can be caused by a loss of AC power to one power supply. Action: Check if AC main power is available to the system. Check if power supply cables are properly connected. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com to replace the power supply. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6518 |
powerSupplyFailureDescription: A power loss has been detected in an enclosure power supply. This can be caused by a failure in the power supply. Action: Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6519 |
powerSupplyAbsentDescription: An enclosure power supply is absent. Action: Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6520 |
unsupportedACVoltageDescription: The power supply for this enclosure is connected to an unsupported AC voltage. The system may operate at a reduced capacity or unexpectedly shut down. Action: Replace the input power with the supported voltage. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6521 |
iOModuleFaultDescription: A fault has been detected with an I/O module and it will not function correctly. Action: The I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6522 |
iOModuleInsertedDescription: An I/O module has been inserted during system runtime. The I/O module will not be powered on until the system is restarted. Action: Restart the system to activate this module. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6523 |
mgmtModuleFaultDescription: A fault has been detected in the management I/O module. Management functions requiring the I/O module will not work. Action: The management I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6524 |
dIMMFailureDescription: A fault has been detected on a memory card. The memory may no longer be usable by the system and the system may not function with the reduced memory capacity. Action: The failing memory card must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6525 |
sPFaultDescription: A fault has been detected on the storage processor. The system may experience unexpected behavior. Action: The failed storage processor must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6526 |
chassisFailureDescription: A fault has been detected in one of the chassis components. The system may experience unexpected behavior. Action: The chassis must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6527 |
forcedControllerShutdownDescription: An environmental condition or hardware fault has been detected that may cause significant damage to the hardware or possible data loss, and the system unit is being shut down. Action: Check the environment, If the system environment is at a normal state, restart the system and review the alert history to determine the source of the problem. Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6528 |
systemResetDescription: A critical failure caused the system to unexpectedly shut down. The system was able to boot successfully either because the fault was corrected, the fault was transient, or the system was able to boot without the component causing the fault. Action: Review the system for earlier alerts to determine the cause of the unexpected shut down. Check the system inventory to verify all components are configured as expected. If this alert is issued again, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6529 |
duplicateAddressDetectionDescription: This IP address has been detected on the network. Connections to this IP address will be adversely impacted. Action: Make sure the local and remote systems are using different IP addresses. Clear the alert once the problem is resolved. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6530 |
spaceReclRestartFailedDescription: Archive space reclamation was running before the last shutdown of the filesystem and could not be restarted automatically. Space will not be reclaimed in the archive tier until space reclamation is restarted. Action: Start space reclamation. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6531 |
spaceReclMissingUnitDescription: Archive units are missing. Space reclamation cannot run unless all configured units are attached. Space will not be reclaimed in the archive tier until space reclamation is restarted. Action: Return missing archive units to the system and start space reclamation. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6532 |
spaceReclUnitReclaimedDescription: All space on the archive unit has been reclaimed. This unit is available to reuse. Action: No action is required. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6533 |
spaceReclErrorDescription: Archive space reclamation has stopped due to the specified error. Space will not be reclaimed in the archive tier until the error condition is resolved and space reclamation is restarted. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6534 |
enclosureHighTempDescription: The temperature inside the enclosure is high and has exceeded the warning threshold.If no action is taken and the temperature continue to increase, the system will shut down. Action: If the temperature around the system unit is within the documented operating limits and the air flow is not blocked, Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6535 |
unsupportedSystemTypeDescription: An unsupported system type has been detected and needs to be modified or replaced. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6536 |
bMCHangShutdownDescription: While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating. Action: After the system is shut down, pull out all power cables from the controller to reset BMC. Wait until all LEDs are off, reinsert the power cables, and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6537 |
expiredHostCertificateDescription: Communication using this certificate is vulnerable to disclosure. Action: Replace the host certificate with a valid certificate. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6538 |
sCSITGTInvalidRegistryDescription: A registry entry used in the SCSI Target system is invalid. The SCSI Target services, including VTL, DD-BOOST FC and VDISK will be inaccessible until this problem is resolved. Action: The registry entry must be corrected. Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6539 |
encryptionKeyExportFailedDescription: The automatic export of the encryption keys failed. This could result in encrypted data being inaccessible. Action: Manually export the encryption keys. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6540 |
sSDEndOfLifeDescription: The SSD has reached end of life and could fail at any time. The system may shut down unexpectedly if the drive is not replaced. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6541 |
tapeRepositionDescription: The tape volume was adjusted to the last consistent data position during VTL recovery. Recent pending updates to the volume may have been discarded. Action: Verify that any backup sent to the affected tape at the time of this alert completed successfully. Reissue the backup if necessary. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6542 |
multipleDiskReadErrorsDescription: There are too many disks reporting read errors in the same RAID group. As each of these disks completes reconstruction it will be failed. If the ongoing RAID reconstruction fails, there might be permanent loss of data. Action: Contact your contracted support provider or visit us online at https://support.emc.com to determine the number of drives that need to be replaced. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6543 |
missingCreplUnitsDescription: The collection replication destination is not in a consistent state and will not be usable until matching retention units are added to the destination. Action: Add the required retention units to the collection replication destination. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6544 |
nvramBattEndOfLifeDescription: The remote battery for NVRAM us currently usable but is approaching the end of its life. If the battery is not replaced before it reaches end of its life, the filesystem will be disabled. Action: To schedule a replacement, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.6545 |
bMCFailureDescription: BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will be disabled. Action: Shut the system down and pull out all power cables from the controller to reset BMC. Wait until all LEDs are off, reinsert the power cables, and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7000 |
unsupportedDriveModelDescription: This system only supports certain drive models. The unsupported drives are unusable and must be replaced for proper system operation. Action: Identify and remove/replace the unsupported drives. For assistance, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7001 |
driveMixTypeDescription: Mixing drive types within an enclosure is not supported and may cause unexpected system behavior. Action: Ensure that all drives within the enclosure are of the same type. For assistance, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7002 |
sMSUnresponsiveDescription: The System Management Service has reached the maximum number of concurrent requests and has been unresponsive for over five minutes. This may indicate a serious condition that may need to be addressed by support. The system is unable to accept additional commands. Action: If this condition persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7500 |
nISCommFailureDescription: Unable to query information from the NIS server. This could be a network problem or an authentication failure with the NIS server. This could prevent NIS servers from completing backups or restoring existing backups. This alert will clear when communication is established with the NIS server. Action: Verify network connection to the NIS server and verify NIS configurations for both systems. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com . NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7501 |
unsupportedHardwareConfigDescription: Unsupported virtual machine hardware configuration was detected. This configuration may cause unexpected behavior. Action: Fix the hardware configuration to resolve the problem. If problem persists, restart the system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7502 |
unsupportedVirtualCPUDescription: The current number of CPU sockets and cores in the virtual machine configuration is not valid for the current storage capacity. The file system will not be enabled. Action: Power off this virtual machine instance and change the virtual machine configuration to match the supported values. If you made this change to add storage capacity, you must add the additional capacity before enabling the file system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7503 |
dNSUnresponsiveDescription: No DNS servers responded to a DNS query. This may be caused by a network failure or a DNS server problem. System functions that require name address resolution will fail. Action: Check the network path and the DNS server to establish communication or remove the DNS entries and add host entries to the hosts table. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7504 |
nTPDFailedDescription: Network Time Protocol (NTP) daemon is not running. NTP daemon has detected a time difference between this system and the configured network time server (drift) greater than the configured maximum and has shut down. Action: Disable NTP. Verify time on the NTP server. Set system date/time to match the time on the NTP server. Enable NTP. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7505 |
invalidEnclosureTopologyDescription: The cables connecting enclosures to the controller are not installed correctly. This can cause unpredictable system behavior. Recable the enclosures immediately. Action: Display the topology to identify the invalid path(s). Power down the system and cable the enclosures according to the cabling guide for your system. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7506 |
diskPathSpeedDegradedDescription: SAS connection speed is degraded and could reduce disk performance. Action: Check cable seating and replace if needed. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7507 |
targetDriverPortOfflineDescription: No connection is detected on the Fibre Channel Port. Action: If this port is not in use, please disable it. If port is being used, please restore Fibre Channel Port connectivity. Alert will be cleared when port is disabled or online. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7508 |
targetDriverPortOnlineDescription: Fibre Channel Port is online. Action: No action required NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7509 |
targetDriverPortCoreDescription: An error occurred on the Fibre Channel Port that resulted in a HBA core. Action: Contact your contracted support provider or visit us online at https://support.emc.com to extract and analyze the HBA core. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7510 |
targetDriverPortMultipleCoreDescription: An error occurred on the Fibre Channel Port that caused multiple HBA core attempts. The Fibre Channel Port is disabled. Action: Contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7511 |
targetDriverPortFWLoadFailedDescription: The Fibre Channel Port is unable to load required firmware. The Fibre Channel Port is disabled. Action: Contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7512 |
targetDriverPortUnreadableDescription: Unable to access one or more resources on the HBA. The Fibre Channel Port is disabled. Action: Contact contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7513 |
targetDriverPortTooManyOscDescription: The system has detected a Fibre Channel Port has been transitioning between online and offline too frequently. This may cause disruption in i/o. Action: Please ensure stable port connectivity. Disable the port if it is not in use. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7514 |
insufficientSpaceForEncryptionDescription: Additional space is needed on the archive tier to encrypt the existing data. Free space up to 1% of data size may be required. Un-encrypted data will not get encrypted until sufficient space is available. Action: Make free space available in the archive tier by doing one or all of the following: 1. Delete any unwanted data in archive tier and run space-reclamation to reclaim free space. 2. Expand the archive unit by adding some storage, and run space-reclamation. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7515 |
dDFSRequiresRebootDescription: File system was unable to start because an abnormal internal condition was detected. Action: Reboot the system. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7516 |
storageUnitStreamSoftLimitDescription: Stream soft limit quota for this storage-unit and type of stream has been exceeded. Crossing this limit may cause reduced performance as the system hard limits are reached. Action: To clear this alert, configure the backup application to use fewer concurrent streams. Otherwise, increase the soft limit quota on this storage-unit for this stream type. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7517 |
spaceReclSuspendedDescription: Archive space reclamation has suspended due to the specified error. Space will not be reclaimed in the archive tier until the error condition is resolved and space reclamation is resumed. Action: Resume space reclamation after the underlying error condition is corrected. If problem persists, Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7518 |
metadataWarningThresholdDescription: Large amount of metadata has been created by the filesystem. Continuing without cleaning would cause the filesystem to enter into read-only mode. Action: Clean the filesystem as soon as possible. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7519 |
mtreeCascadeNeedResyncDescription: This Mtree is now a cascaded source. Since this mtree already has data, this replication context requires a resync to proceed. Action: To re-establish replication - Note the context information - break the context - reconfigure contexts on both source and destination - resync context on the source NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7520 |
filesystemCorruptionDescription: Filesystem processing detected some corruption. This may be isolated to a single file or multiple files, preventing you from reading the corrupted files. If a system file is affected, the filesystem could be disabled. Until this corruption is fixed, you will not be able to run cleaning, data-movement or space reclamation on the affected tier. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7521 |
missingTierStorageDescription: Critical storage resources are unavailable, preventing the tier from functioning. Action: Verify all storage is functional and configured correctly. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7522 |
spaceReclUnitErrorDescription: Space reclamation encountered an error and cannot proceed on the specified archive unit. If you have more than one archive unit, space reclamation will continue on the next unit. Space will not be reclaimed in this archive unit until the error condition is resolved and space reclamation finishes successfully on this unit. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7523 |
bMCFailureSysBBUDescription: BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will be disabled. Action: Shut the system down and remove all external power sources from the controller. Remove the system battery backup unit (BBU). Wait until all LEDs are off, reinsert the BBU, connect external power, and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.7524 |
licenseExpiringDescription: The temporary license indicated is about to expire. The function provided by this license will cease to operate. Action: Contact your [account team] to purchase a license if you wish to continue to use this feature. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.8001 |
licenseExpiredDescription: The temporary license indicated has expired. The function provided by this license has stopped operating. Action: Contact your [account team] to purchase a license if you wish to use this feature. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.8002 |
unsupportedEnclosurePSUDescription: A power supply has been detected in an enclosure which does not provide complete environmental information. This will not affect normal operations but should be replaced as soon as convenient. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10000 |
unsupportedPowerSupplyDescription: The installed power supply is an unsupported model. The system may exhibit unexpected behavior. Action: Replace the power supply with a supported model. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10001 |
openFanDrawerDescription: Fan drawer is not closed securely. Failure to secure the fan drawer may allow the system to overheat and shut down. Action: Close and secure the fan drawer. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10002 |
memoryRiserFaultDescription: A critical failure has been detected in a memory riser. Memory attached to this riser may disappear from the system inventory. The system may exhibit unexpected behavior. Action: Contact your contracted support provider or visit us online at https://support.emc.com to replace the memory riser. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10003 |
pCILinkDegradedDescription: The system has detected that PCI communication speed is degraded. This will not cause the system to fail but may impact performance of affected components. Action: Reboot the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10004 |
invalidHardwareCriticalDescription: During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location. The filesystem cannot be enabled with the current hardware configuration. Action: View enclosure misconfiguration to determine the problem. For assistance, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10005 |
invalidHardwareWarningDescription: During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location. Some components may not operate as expected. Action: View enclosure misconfiguration to determine the problem. For assistance, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10006 |
correctableErrorWarningDescription: The system has detected excessive correctable errors on a component that may indicate a hardware failure. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10007 |
spuriousInterruptDisabledDescription: Excessive spurious hardware messages have been detected that may indicate a hardware failure. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10008 |
corruptEncryptionKeysDescription: File system was locked as the encryption keys cannot not be validated. One or more encryption keys could be corrupt. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10009 |
duplicateVTLPoolNamesDescription: VTL directory pool and a VTL mtree pool have been detected with the same name. Viewing pool information will only retrieve tapes from the mtree pool. Tapes in the directory pool will not be visible to DataDomain system administration interfaces. Backups and restores using the directory pool will operate normally. Action: Rename one of the pools to make the name unique. The duplicate pool name may have been created as part of a replication pair.If problem persists, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10010 |
generalHardwareFailureDescription: A critical failure has been detected in one or more chassis components. The system may exhibit unexpected behavior. Action: Contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10011 |
iOModuleMacFaultDescription: A Mac fault has been detected with an I/O module and it will not function correctly. Action: The I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10013 |
storageMigrationCannotResumeDescription: The system has detected a condition which prevented the storage migration from continuing and has suspended the data copy phase. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10500 |
storageMigrationCopyCompleteDescription: All data has been moved from old enclosures to the new enclosures. Storage migration must be finalized to decommission old enclosures and add new capacity to the file system. Action: Finalize the storage migration. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10501 |
storageMigrationUserSuspendDescription: An administrator has suspended the data copy phase of storage migration. Data copy cannot proceed until it is manually resumed. Action: Resume the storage migration. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10502 |
cMTaskEndedDescription: A long running task has ended. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10503 |
physicalCapacityMeasurementTasksLostDescription: File system has been disabled either by a failure or user action. Physical-capacity-measurement samples for these tasks are no longer available. Action: Restart physical-capacity-measurement sample tasks that have not completed. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10504 |
physicalCapacityMeasurementTasksLostMTreeDescription: MTree replication was broken or resynced causing one or more physical-capacity-measurement sample tasks to be cancelled. Physical-capacity-measurement samples for these tasks are no longer available. Action: Restart physical-capacity-measurement sample tasks that have not completed for this MTree. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10505 |
physicalCapacityMeasurementScheduleFailedDescription: A physical-capacity-measurement sample task that was scheduled to run was unable to start due to an error. Some or all of the physical-capacity-measurement samples for these tasks are not available. Action: Review scheduled physical-capacity-measurement sample task errors to determine the reason for the failure. Resubmit failed tasks if needed. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10506 |
historicalDatabaseFailoverErrorDescription: Historical database failover failed. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10507 |
hAdegradedDescription: A condition has been detected causing the configured HA system to be degraded. Any failover attempt will not succeed. Action: Display the HA detailed status to determine the failed component. Repairing the failed component can return the HA system to available state. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10508 |
upgradeInProgressDescription: DD OS upgrade is in progress. The system will not be available for backup and restore operations. The alert will be cleared after the upgrade operation is complete. Action: Allow the upgrade operation to complete. If the upgrade takes longer than usual, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10509 |
hAofflineErrorsDescription: Critical system errors have been detected causing the configured HA system to be in offline state. Access to system services may be unavailable. Action: Review exisiting alerts. Fixing issues identified by these alerts may resolve this alert. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10510 |
suspendedMReplMissingUnitsDescription: Mtree replication on this context cannot continue until all archive units used by this Mtree are online. Replication will resume automatically once all archive units come online. Action: Return missing archive units to the system to resume MTree replication for this context. If the archive units cannot be restored, contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10511 |
foreignPackDescription: The enclosure pack is unusable by the file system. Storage configuration can not be modified while a foreign device is present. Action: If this is expected as part of a chassis swap or chassis upgrade, proceed with the headswap operation to make the foreign filesystem available. Otherwise contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10512 |
vDiskSCSITargetMismatchDescription: VDisk configuration does not match SCSI Target configuration. Non-matching devices are not available and must be deleted or repaired. Action: Contact your contracted support provider or visit us online at https://support.emc.com NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10513 |
hATimeOutOfSyncDescription: Timestamps of logs and system events will not match between the HA nodes. This condition will not have an effect on HA functionality or system operation. Action: Set the time on the standby node to match the active node. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10514 |
enclosureMixDriveTypeDescription: An unsupported mix of enclosures with different drive types may impact performance and lead to unexpected system behavior. Action: Recable the enclosures to eliminate the unsupported mix. Refer to the configuration guide for valid cabling configurations. NOTIFICATION-TYPE .1.3.6.1.4.1.19746.2.0.10515 |
dataDomainMibProducts OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3 |
restorer OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1 |
unknown OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.0 |
dd200 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.1 |
dd200Proto OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.2 |
dd410 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.3 |
dd430 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.4 |
dd460 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.5 |
dd400g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.6 |
dd460g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.7 |
dd560 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.8 |
dd560g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.9 |
dd580 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.10 |
dd580g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.11 |
dd565 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.12 |
dd530 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.13 |
dd510 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.14 |
dd120 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.15 |
dd690 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.16 |
dd690g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.17 |
dd660 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.18 |
dd880 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.19 |
dd880g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.20 |
dd610 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.21 |
dd630 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.22 |
dd140 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.23 |
dd670 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.24 |
dd860 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.25 |
dd860g OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.26 |
dd890 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.27 |
dd640 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.28 |
dd620 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.29 |
dd160 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.30 |
ddintrepid OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.31 |
dd4500 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.32 |
dd7200 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.33 |
ddve OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.34 |
dd990 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.35 |
dd2500 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.36 |
dd4200 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.37 |
ddkoalam1 OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.38 |
apollo OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.39 |
unset OBJECT IDENTIFIER .1.3.6.1.4.1.19746.3.1.9999 |