DASAN-GIGABIT-OPTIC-TRANSCEIVER-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for DASAN-GIGABIT-OPTIC-TRANSCEIVER-MIB.
.
Main OID:
dsGigabitOpticTransceiverMIB.1.3.6.1.4.1.6296.9.1.1.2.13
102
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
102 total| Object Name |
|---|
dsGigabitOpticTransceiverMIB. MODULE-IDENTITY .1.3.6.1.4.1.6296.9.1.1.2.13 |
dsGOTransceiverInfo OBJECT IDENTIFIER .1.3.6.1.4.1.6296.9.1.1.2.13.1 |
dsGOTransceiverBaseTable. SEQUENCE OF DsGOTransceiverBaseEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.1 |
dsGOTransceiverBaseEntry. DsGOTransceiverBaseEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1 |
dsGOTransceiverIdentifierType of serial transceiver.ro DsGOTransceiverIdentifierType .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.1 |
dsGOTransceiverExtIdentifierExtended identifier of type of serial transceiver.ro DsGOTransceiverExtIdentifierType .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.2 |
dsGOTransceiverConnectorCode for connector type.ro DsGOTransceiverConnectorType .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.3 |
dsGOTransceiverTransceiverCode for electronic compatibility or optical compatibility.ro DsGoTransceiverTransceiverType .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.4 |
dsGOTransceiverEncodingCode for serial encoding algorithm.ro DsGOTransceiverEncodingType .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.5 |
dsGOTransceiverBRNominalNominal bit rate, units of 100 MBits/sec..ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.6 |
dsGOTransceiverLength9u_kLink length supported for 9/125 mm fiber, units of k.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.7 |
dsGOTransceiverLength9u_100mLink length supported for 9/125 mm fiber, units of 100 m.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.8 |
dsGOTransceiverLength50uLink length supported for 50/125 mm fiber, units of 10 m.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.9 |
dsGOTransceiverLength62dot5uLink length supported for 62.5/125 mm fiber, units of 10 m.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.10 |
dsGOTransceiverLengthCooperLink length supported for copper, units of meters.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.11 |
dsGOTransceiverVendorNameGBIC vendor name (ASCII).ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.12 |
dsGOTransceiverVendorOUIGBIC vendor IEEE company ID.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.13 |
dsGOTransceiverVendorPNPart number provided by GBIC vendor (ASCII).ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.14 |
dsGOTransceiverVendorRevRevision level for part number provided by vendor (ASCII).ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.15 |
dsGOTransceiverCCBaseCheck code for Base ID Fields.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.1.1.16 |
dsGOTransceiverExtTable. SEQUENCE OF DsGOTransceiverExtEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.2 |
dsGOTransceiverExtEntry. DsGOTransceiverExtEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1 |
dsGOTransceiverExtOptionsIndicates which optional GBIC signals are implemented.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.1 |
dsGOTransceiverExtBrMaxUpper bit rate margin, units of %.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.2 |
dsGOTransceiverExtBrMinLower bit rate margin, units of %.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.3 |
dsGOTransceiverExtVendorSNSerial number provided by vendor (ASCII).ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.4 |
dsGOTransceiverExtDateCodeVendor's manufacturing date code.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.5 |
dsGOTransceiverExtDiagMonitoringType.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.6 |
dsGOTransceiverExtEnhancedOptions.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.7 |
dsGOTransceiverExtSff8472Compliance.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.8 |
dsGOTransceiverExtCCExtCheck code for the Extended ID Fields.ro INTEGER .1.3.6.1.4.1.6296.9.1.1.2.13.1.2.1.9 |
dsGOTransceiverDiagInfo OBJECT IDENTIFIER .1.3.6.1.4.1.6296.9.1.1.2.13.1.3 |
dsGOTransceiverDiagTable. SEQUENCE OF DsGOTransceiverDiagEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1 |
dsGOTransceiverDiagEntry. DsGOTransceiverDiagEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1 |
dsGOTransceiverDiagTemperInternally measured module temperature.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.1 |
dsGOTransceiverDiagVoltageInternally measured supply voltage in transceiver.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.2 |
dsGOTransceiverDiagTxBiasInternally measured TX Bias Current.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.3 |
dsGOTransceiverDiagTxPowerMeasured TX output power.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.4 |
dsGOTransceiverDiagRxPowerMeasured RX input power.ro OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.5 |
dsGOTransceiverDiagThresholdTable. SEQUENCE OF DsGOTransceiverDiagThresholdEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2 |
dsGOTransceiverDiagThresholdEntry. DsGOTransceiverDiagThresholdEntry .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1 |
dsGOTransceiverDiagThresholdAlarmTempHighThe alarm-high-threshold of temperature.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.1 |
dsGOTransceiverDiagThresholdAlarmTempLowThe alarm-low-threshold of temperature.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.2 |
dsGOTransceiverDiagThresholdWarnTempHighThe warning-high-threshold of temperature.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.3 |
dsGOTransceiverDiagThresholdWarnTempLowThe warning-low-threshold of temperature.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.4 |
dsGOTransceiverDiagThresholdAlarmVolHighThe alarm-high-threshold of voltage.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.5 |
dsGOTransceiverDiagThresholdAlarmVolLowThe alarm-low-threshold of voltage.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.6 |
dsGOTransceiverDiagThresholdWarnVolHighThe warning-high-threshold of voltage.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.7 |
dsGOTransceiverDiagThresholdWarnVolLowThe warning-low-threshold of voltage.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.8 |
dsGOTransceiverDiagThresholdAlarmTxBiasHighThe Alarm-high-threshold of tx bias.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.9 |
dsGOTransceiverDiagThresholdAlarmTxBiasLowThe Alarm-low-threshold of tx bias.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.10 |
dsGOTransceiverDiagThresholdWarnTxBiasHighThe warning-high-threshold of tx bias.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.11 |
dsGOTransceiverDiagThresholdWarnTxBiasLowThe warning-low-threshold of tx bias.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.12 |
dsGOTransceiverDiagThresholdAlarmTxPowerHighThe alarm-high-threshold of tx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.13 |
dsGOTransceiverDiagThresholdAlarmTxPowerLowThe alarm-low-threshold of tx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.14 |
dsGOTransceiverDiagThresholdWarnTxPowerHighThe warning-high-threshold of tx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.15 |
dsGOTransceiverDiagThresholdWarnTxPowerLowThe warning-low-threshold of tx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.16 |
dsGOTransceiverDiagThresholdAlarmRxPowerHighThe alarm-high-threshold of rx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.17 |
dsGOTransceiverDiagThresholdAlarmRxPowerLowThe alarm-low-threshold of rx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.18 |
dsGOTransceiverDiagThresholdWarnRxPowerHighThe warning-high-threshold of rx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.19 |
dsGOTransceiverDiagThresholdWarnRxPowerLowThe warning-low-threshold of rx power.rw OCTET STRING .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.2.1.20 |
dsGOTransceiverDiagNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3 |
dsGOTransceiverDiagTempHighOverAlarmThis notification is generated in case of temperature is over alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.1 |
dsGOTransceiverDiagTempHighFallAlarmThis notification is generated in case of temperature fall under alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.2 |
dsGOTransceiverDiagTempLowOverAlarmThis notification is generated in case of temperature is over alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.3 |
dsGOTransceiverDiagTempLowFallAlarmThis notification is generated in case of temperature fall under alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.4 |
dsGOTransceiverDiagTempHighOverWarningThis notification is generated in case of temperature is over warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.5 |
dsGOTransceiverDiagTempHighFallWarningThis notification is generated in case of temperature fall under warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.6 |
dsGOTransceiverDiagTempLowOverWarningThis notification is generated in case of temperature is over warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.7 |
dsGOTransceiverDiagTempLowFallWarningThis notification is generated in case of temperature fall under warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.8 |
dsGOTransceiverDiagVolHighOverAlarmThis notification is generated in case of voltage is over alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.9 |
dsGOTransceiverDiagVolHighFallAlarmThis notification is generated in case of voltage fall under alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.10 |
dsGOTransceiverDiagVolLowOverAlarmThis notification is generated in case of voltage is over alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.11 |
dsGOTransceiverDiagVolLowFallAlarmThis notification is generated in case of voltage fall under alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.12 |
dsGOTransceiverDiagVolHighOverWarningThis notification is generated in case of voltage is over warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.13 |
dsGOTransceiverDiagVolHighFallWarningThis notification is generated in case of voltage fall under warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.14 |
dsGOTransceiverDiagVolLowOverWarningThis notification is generated in case of voltage is over warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.15 |
dsGOTransceiverDiagVolLowFallWarningThis notification is generated in case of voltage fall under warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.16 |
dsGOTransceiverDiagTxBiasHighOverAlarmThis notification is generated in case of TX bias is over alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.17 |
dsGOTransceiverDiagTxBiasHighFallAlarmThis notification is generated in case of TX bias fall under alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.18 |
dsGOTransceiverDiagTxBiasLowOverAlarmThis notification is generated in case of TX bias is over alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.19 |
dsGOTransceiverDiagTxBiasLowFallAlarmThis notification is generated in case of TX bias fall under alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.20 |
dsGOTransceiverDiagTxBiasHighOverWarningThis notification is generated in case of TX bias is over warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.21 |
dsGOTransceiverDiagTxBiasHighFallWarningThis notification is generated in case of TX bias fall under warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.22 |
dsGOTransceiverDiagTxBiasLowOverWarningThis notification is generated in case of TX bias is over warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.23 |
dsGOTransceiverDiagTxBiasLowFallWarningThis notification is generated in case of TX bias fall under warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.24 |
dsGOTransceiverDiagTxPowerHighOverAlarmThis notification is generated in case of TX power is over alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.25 |
dsGOTransceiverDiagTxPowerHighFallAlarmThis notification is generated in case of TX power fall under alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.26 |
dsGOTransceiverDiagTxPowerLowOverAlarmThis notification is generated in case of TX power is over alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.27 |
dsGOTransceiverDiagTxPowerLowFallAlarmThis notification is generated in case of TX power fall under alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.28 |
dsGOTransceiverDiagTxPowerHighOverWarningThis notification is generated in case of TX power is over warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.29 |
dsGOTransceiverDiagTxPowerHighFallWarningThis notification is generated in case of TX power fall under warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.30 |
dsGOTransceiverDiagTxPowerLowOverWarningThis notification is generated in case of TX power is over warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.31 |
dsGOTransceiverDiagTxPowerLowFallWarningThis notification is generated in case of TX power fall under warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.32 |
dsGOTransceiverDiagRxPowerHighOverAlarmThis notification is generated in case of RX power is over alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.33 |
dsGOTransceiverDiagRxPowerHighFallAlarmThis notification is generated in case of RX power fall under alarm-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.34 |
dsGOTransceiverDiagRxPowerLowOverAlarmThis notification is generated in case of RX power is over alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.35 |
dsGOTransceiverDiagRxPowerLowFallAlarmThis notification is generated in case of RX power fall under alarm-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.36 |
dsGOTransceiverDiagRxPowerHighOverWarningThis notification is generated in case of RX power is over warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.37 |
dsGOTransceiverDiagRxPowerHighFallWarningThis notification is generated in case of RX power fall under warning-high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.38 |
dsGOTransceiverDiagRxPowerLowOverWarningThis notification is generated in case of RX power is over warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.39 |
dsGOTransceiverDiagRxPowerLowFallWarningThis notification is generated in case of RX power fall under warning-low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.9.1.1.2.13.1.3.3.40 |