Standard SNMP MIB module defining data structures for CPQSTSYS-MIB.

203
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

203 total
Object Name
cpqSs2FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8001
cpqSsTempFailedStorage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8002
cpqSsTempDegradedStorage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8003
cpqSsTempOkStorage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8004
cpqSsSidePanelInPlaceStorage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8005
cpqSsSidePanelRemovedStorage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8006
cpqSsPwrSupplyDegradedA storage system power supply status has been set to degraded.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8007
cpqSs3FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8008
cpqSs3TempFailedStorage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8009
cpqSs3TempDegradedStorage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8010
cpqSs3TempOkStorage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8011
cpqSs3SidePanelInPlaceStorage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8012
cpqSs3SidePanelRemovedStorage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel. User Action: Replace the storage system side panel.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8013
cpqSs3PwrSupplyDegradedA storage system power supply status has been set to degraded.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8014
cpqSs4PwrSupplyDegradedA storage system power supply status has been set to degraded. User Action: Take action to restore power or replace any failed storage system power supply.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8015
cpqSsExFanStatusChangeStorage system fan status change. The agent has detected a change in the Fan Module Status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8016
cpqSsExPowerSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8017
cpqSsExPowerSupplyUpsStatusChangeStorage system power supply UPS status change. The agent has detected a change status of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current status. User Action: If the UPS status is powerFailed(4) or batteryLow(5), take action to restore power to the UPS.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8018
cpqSsExTempSensorStatusChangeStorage system temperature sensor status change. The agent has detected a change in the status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8019
cpqSsEx2FanStatusChangeStorage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8020
cpqSsEx2PowerSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8021
cpqSsExBackplaneFanStatusChangeStorage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8022
cpqSsExBackplaneTempStatusChangeStorage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8023
cpqSsExBackplanePowerSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8024
cpqSsExRecoveryServerStatusChangeStorage system recovery server option status change. The agent has detected a change in the recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the current status. User Action: If the RSO status is noSecondary(6) or linkDown(7), insure the secondary server is operational and all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the the primary server for failed components.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8025
cpqSs5FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8026
cpqSs5TempStatusChangeStorage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8027
cpqSs5PwrSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8028
cpqSs6FanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8029
cpqSs6TempStatusChangeStorage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8030
cpqSs6PwrSupplyStatusChangeStorage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
TRAP-TYPE
.1.3.6.1.4.1.232.0.8031
cpqSsConnectionStatusChangeStorage system connection status change. The agent has detected a change in the connection status of a storage system. The variable cpqSSboxConnectionStatus indicates the current connection status. User Action: If the connection status is disconnected, take action to restore the connection between the HBA and the storage system
TRAP-TYPE
.1.3.6.1.4.1.232.0.8032
cpqSsStorageSys
OBJECT IDENTIFIER
.1.3.6.1.4.1.232.8
RFC1213-MIB
Unknown
.1.3.6.1.4.1.232.8
cpqSsFanStatusChangeStorage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
TRAP-TYPE
.1.3.6.1.4.1.232.8.0.1
cpqSsMibRev
OBJECT IDENTIFIER
.1.3.6.1.4.1.232.8.1
cpqSsMibRevMajorThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level.ro
INTEGER
.1.3.6.1.4.1.232.8.1.1
cpqSsMibRevMinorThe Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occurred.ro
INTEGER
.1.3.6.1.4.1.232.8.1.2
cpqSsMibConditionThe overall condition (status) of the system represented by this MIB.ro
Enumeration
.1.3.6.1.4.1.232.8.1.3
cpqSsDrvBox
OBJECT IDENTIFIER
.1.3.6.1.4.1.232.8.2
cpqSsDrvBoxTableDrive Box Table.
SEQUENCE OF CpqSsDrvBoxEntry
.1.3.6.1.4.1.232.8.2.1
cpqSsDrvBoxEntryDrive Box Entry.
CpqSsDrvBoxEntry
.1.3.6.1.4.1.232.8.2.1.1
cpqSsBoxCntlrIndexDrive Box Controller Index. The controller index indicates to which adapter card instance this table entry belongs.ro
INTEGER
.1.3.6.1.4.1.232.8.2.1.1.1
cpqSsBoxBusIndexDrive Box Bus Index. The bus index indicates to which bus instance on an adapter card this table entry belongs.ro
INTEGER
.1.3.6.1.4.1.232.8.2.1.1.2
cpqSsBoxTypeDrive Box Type. This is the type of drive box. The following types are defined: other(1) The agent does not recognize this drive storage system. proLiant(2) This is a ProLiant Storage System. proLiant2(3) This is a ProLiant-2 Storage System. proLiant2Internal(4) This is an internal ProLiant-2 Storage System that is found in some servers. proLiant2DuplexTop(5) This is the top portion of a ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2DuplexBottom(6) This is the bottom portion of a ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2InternalDuplexTop(7) This is the top portion of a ProLiant Server into which the internal SCSI busses are duplexed. proLiant2InternalDuplexBottom(8) This is the bottom portion of a ProLiant Server into which the internal SCSI busses are duplexed.rodeprecated
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.3
cpqSsBoxModelDrive Box Model. This is a description of the drive box's model. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.4
cpqSsBoxFWRevDrive Box Firmware Revision. This is the revision level of the drive box. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.5
cpqSsBoxVendorDrive Box Vendor This is the drive box's vendor name. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.6
cpqSsBoxFanStatusDrive Box Fan Status. This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supported by this system or it is not supported by the driver. ok(2) All fans are working normally. failed(3) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. noFan(4) This unit does not support fan monitoring. degraded(5) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.7
cpqSsBoxConditionSCSI Drive Box Condition. This is the overall condition of the drive box. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. Additionally, if the side panel for the storage system is removed, the air flow changes could result in improper cooling of the drives and affect the temperature status. failed(4) The storage system has failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.8
cpqSsBoxTempStatusThe temperature of the drive system. This value will be one of the following: other(1) Temperature monitoring is not supported by this system or it is not supported by the driver. ok(2) The temperature is within normal operating range. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected. noTemp(5) This unit does not support temperature monitoring.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.9
cpqSsBoxSidePanelStatusDrive Box Side Panel Status. This value will be one of the following: other(1) The agent does not recognize the status. You may need to upgrade your software. sidePanelInPlace(2) The side panel is properly installed on the storage system. sidePanelRemoved(3) The side panel is not properly installed on the storage system. noSidePanelStatus(4) This unit does not support side panel status monitoring.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.10
cpqSsBoxFltTolPwrSupplyStatusThis value specifies the overall status of the fault tolerant power supply sub-system in a drive box. This value will be one of the following: other(1) The power supply status cannot be determined. ok(2) There are no detected power supply failures. degraded(3) One of the power supply units in a fault tolerant power supply has failed. failed(4) No failure conditions can currently be determined. noFltTolPower(5) This unit does not support fault tolerant power supply monitoring.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.11
cpqSsBoxBackPlaneVersionDrive Box Back Plane Version. This is the version of the drive box back plane. The following types are defined: other(1) The agent does not recognize this drive storage system back plane. proLiant(2) This is a ProLiant Storage System. proLiant2(3) This is a ProLiant-2 Storage System. proLiant3(4) This is a ProLiant-3 Storage System. proLiant4(5) This is a 4th generation Proliant Storage System. proLiant5(6) This is a 5th generation ProLiant Storage System.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.12
cpqSsBoxTotalBaysDrive Box Total Bays. This is the total number of bays in this storage system. If the value cannot be determined or does not apply, -1 is returned.ro
INTEGER
.1.3.6.1.4.1.232.8.2.1.1.13
cpqSsBoxPlacementDrive Box Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.14
cpqSsBoxDuplexOptionDrive Box Duplex Option. The following values are defined: other(1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.15
cpqSsBoxBoardRevisionDrive Box Board Revision. This is the board revision of this storage system backplane.ro
INTEGER
.1.3.6.1.4.1.232.8.2.1.1.16
cpqSsBoxSerialNumberDrive Box Serial Number. This is the drive box's serial number which is normally display on the front panel. This can be used for identification purposes. If the box's serial number cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.17
cpqSsBoxCntlrHwLocationA text description of the hardware location of the controller to which this box is attached. A NULL string indicates that the hardware location could not be determined or is irrelevant.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.18
cpqSsBoxBackplaneSpeedDrive Box Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) This storage system is capable of Ultra3 speeds. ultra320(3) This storage system is capable of Ultra320 speeds.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.19
cpqSsBoxConnectionTypeDrive Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this storage system. scsiAttached(2) This storage system is attached to the host via SCSI. sasAttached(3) This storage system is attached to the host via SAS.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.20
cpqSsBoxHostConnectorDrive Box Host Connector. This is the host connector to which the drive box is attached. If the host connector cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.21
cpqSsBoxBoxOnConnectorDrive Box, Box on Connector. The box on connector indicates which box instance this table entry belongs. The instances start at one and increment for each box attached to a connector. If the value cannot be determined or does not apply, -1 is returned.ro
INTEGER
.1.3.6.1.4.1.232.8.2.1.1.22
cpqSsBoxLocationStringDrive Box Location String. This string describes the location of the drive box in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.23
cpqSsBoxInitiatorSasAddressDrive Box Initiator SAS Address String. This string describes the SAS address of the initiator connected to the drive box. If the drive box initiator SAS address string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.24
cpqSsBoxTargetSasAddressDrive Box Target SAS Address String. This string describes the SAS address of the target (i.e. the drive box itself). If the drive box target SAS address string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.25
cpqSsBoxLocalManageIpAddressDrive Box Local Management IP Address String. This string reports the management IP address for the storage box primary controller. If the drive box local management IP address string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.26
cpqSsBoxPartnerManageIpAddressDrive Box Partner Management IP Address String. This string reports the management IP address for the storage box partner controller. If the drive box partner management IP address string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.1.1.27
cpqSsBoxConnectionStatusDrive Box Connection Status. The following values are defined: other(1) The agent is unable to determine the storage system's connection status. notSupported(2) Reporting this storage system's connection status is not supported. connected(3) The storage system is connected. notConnected(4) The storage system is disconnected.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.28
cpqSsBoxTargetBasedManagementDrive Box Target Based Management. The following values are defined: other(1) The agent is unable to determine if this storage system supports target based management. tbmNotSupported(2) The storage system does not support target based management. tbmSupported(3) The storage system supports target based management.ro
Enumeration
.1.3.6.1.4.1.232.8.2.1.1.29
cpqSsBoxExtended
OBJECT IDENTIFIER
.1.3.6.1.4.1.232.8.2.2
cpqSsChassisTableStorage System Chassis Table.
SEQUENCE OF CpqSsChassisEntry
.1.3.6.1.4.1.232.8.2.2.1
cpqSsChassisEntryStorage System Chassis Entry.
CpqSsChassisEntry
.1.3.6.1.4.1.232.8.2.2.1.1
cpqSsChassisIndexStorage System Chassis Index. The chassis index uniquely identifies a storage system chassis.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.1.1.1
cpqSsChassisConnectionTypeStorage System Chassis Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this chassis. fibreAttached(2) This chassis is attached to the server via Fibre Channel. scsiAttached(3) This chassis is attached to the server via SCSI. iScsiAttached(4) This chassis is attached to the server via iSCSI. sasAttached(5) This chassis is attached to the server via SAS.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.2
cpqSsChassisSerialNumberStorage System Chassis Serial Number. This is the storage system chassis's serial number which is normally displayed on the front panel. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.3
cpqSsChassisNameStorage System Chassis Name. This is a user defined name for this storage system chassis.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.4
cpqSsChassisSystemBoardSerNumStorage System Chassis System Controller Board Serial Number. This is the system controller board's serial number. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.5
cpqSsChassisSystemBoardRevStorage System Chassis System Controller Board Revision. This is the system controller board revision.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.6
cpqSsChassisPowerBoardSerNumStorage System Chassis Power Backplane Board Serial Number. This is the power backplane board's serial number. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.7
cpqSsChassisPowerBoardRevStorage System Chassis Power Backplane Board Revision. This is the power backplane board revision.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.8
cpqSsChassisScsiBoardSerNumStorage System Chassis SCSI Drive Backplane Board Serial Number. This is the SCSI drive backplane board's serial number. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.9
cpqSsChassisScsiBoardRevStorage System Chassis SCSI Drive Backplane Board Revision. This is the SCSI drive backplane board revision.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.10
cpqSsChassisOverallConditionStorage System Chassis Overall Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system chassis is degraded. failed(4) The storage system chassis is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.11
cpqSsChassisPowerSupplyConditionStorage System Power Supply Condition. This is the aggregate condition of all power supplies in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All power supplies are operating normally. degraded(3) At least one power supply is degraded or failed. failed(4) All power supplies are failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.12
cpqSsChassisFanConditionStorage System Fan Condition. This is the aggregate condition of all fan modules in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All fan modules are operating normally. degraded(3) At least one fan module is degraded. failed(4) At least one fan module is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.13
cpqSsChassisTemperatureConditionStorage System Temperature Condition. This is the aggregate condition of all the temperatur sensors in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All temperature sensors are reading within normal limits. degraded(3) At least one temperature sensor is reading degraded. failed(4) At least one temperature sensor is reading failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.14
cpqSsChassisFcaCntlrConditionStorage System Fibre Channel Array Controller Condition. This is the aggregate condition of all Fibre Channel Array controllers in the storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers are operating normally. degraded(3) At least one Fibre Channel Array Controller is degraded or failed. failed(4) All Fibre Channel Array Controllers are failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.15
cpqSsChassisFcaLogicalDriveConditionStorage System Fibre Channel Array Logical Drive Condition. This is the aggregate condition of all Fibre Channel Array Logical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Logical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Logical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Logical Drive is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.16
cpqSsChassisFcaPhysDrvConditionStorage System Fibre Channel Array Physical Drive Condition. This is the aggregate condition of all Fibre Channel Array Physical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Physical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Physical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Physical Drive is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.17
cpqSsChassisTimeStorage System Chassis Time. This is the storage system chassis's time in tenths of seconds. If the chassis time is not supported, the agent will return 0.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.1.1.18
cpqSsChassisModelStorage System Chassis Model. The following values are defined: other(1) The agent is unable to determine the model of this chassis. ra4x00(2) Compaq StorageWorks RAID Array 4000/4100. msa1000(3) Compaq StorageWorks Modular Smart Array 1000. smartArrayClusterStorage(4) HP StorageWorks Modular Smart Array 500 (Formerly Smart Array Cluster Storage). enterpriseModularArray(5) Compaq StorageWorks Enterprise/Modular RAID Array. enterpriseVirtualArray(6) Compaq StorageWorks Enterprise Virtual Array. msa500G2(7) HP StorageWorks Modular Smart Array 500 G2. msa20(8) HP StorageWorks Modular Smart Array 20. msa1500cs(9) HP StorageWorks Modular Smart Array 1500 CS. msa1510i(10) HP StorageWorks Modular Smart Array 1510i. Reserved(11) Reserved(12)ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.19
cpqSsChassisBackplaneConditionStorage System Backplane Condition. This is the aggregate condition of all the backplanes for the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All backplanes are operating normally. degraded(3) At least one storage system is degraded. failed(4) At least one storage system is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.20
cpqSsChassisFcaTapeDrvConditionStorage System Array Tape Drive Condition. This is the aggregate condition of all tape drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All tape drives are operating normally. degraded(3) At least one tape drive is degraded. failed(4) At least one tape drive is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.21
cpqSsChassisRsoStatusStorage System Chassis Recovery Server Option Status. The following values are defined: other(1) The recovery server option status cannot be determined for this storage system. notSupported(2) The recovery server option is not supported for this storage system. notConfigured(3) The recovery server option is supported, but is not configured on this storage system. disabled(4) The recovery server option is configured as primary, but has been disabled by software. daemonDownDisabled(5) The recovery server option operating system daemon is no longer running. The last status of RSO was disabled(4). ok(6) The recovery server option is configured as primary and everything is working correctly. daemonDownActive(7) The recovery server option operating system daemon is no longer running. The last status of RSO was ok(6). noSecondary(8) The recovery server option is configured as primary, but communication with the standby server has not been established. daemonDownNoSecondary(9) The recovery server option operating system daemon is no longer running. The last status of RSO was noSecondary(8). linkDown(10) The recovery server option is configured as primary, but communication with the standby server has failed. daemonDownLinkDown(11) The recovery server option operating system daemon is no longer running. The last status of RSO was linkDown(10). secondaryRunningAuto(12) The recovery server option is configured and the standby server is running. The secondary server assumed control after communication with the primary server failed. secondaryRunningUser(13) The recovery server option is configured and the standby server is running. A user forced the secondary server to assume control. evTimeoutError(14) The recovery server option environment variable cannot be accessed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.22
cpqSsChassisRsoConditionStorage System Chassis Recovery Server Option Condition. This is the condition of the recovery server option. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The recovery server option is operating normally. No user action is required. degraded(3) The recovery server option is degraded. failed(4) The recovery server option is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.23
cpqSsChassisScsiIoModuleTypeStorage System Chassis SCSI I/O Module Type. The following values are defined: other(1) The agent does not recognize SCSI I/O module type. You may need to upgrade your software. io2port(2) A 2-Port Ultra3 SCSI I/O Module is installed. io4portUpgradeFirmware(3) A 4-Port Shared Storage Module for Smart Array Cluster Storage is installed, but the current controller firmware does not support it. Upgrade your controller firmware. io4port(4) A 4-Port Shared Storage Module for Smart Array Cluster Storage is installed. io2port320(5) A 2-Port Ultra320 SCSI I/O Module is installed. io4port320(6) A 4-Port Ultra320 SCSI I/O Module is installed. io1port320(7) A 1-Port Ultra320 SCSI I/O Module is installed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.24
cpqSsChassisPreferredPathModeArray Controller Preferred Path Mode. This is the storage system active/active preferred path mode. The following values are valid: other (1) Indicates that the agent does not recognize the preferred path mode of the storage system. You may need to upgrade the agent. notActiveActive (2) The storage system is not configured as active/active. automatic (3) The storage system automatically selects the preferred path for each logical drive based on host I/O patterns. manual (4) The preferred path for each logical drive is manually configured by the storage system administrator.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.1.1.25
cpqSsChassisProductIdStorage System Chassis Product Identifier. This is the storage system chassis's product identifier. This can be used for identification purposes. If the product identifier can not be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.1.1.26
cpqSsIoSlotTableStorage System I/O Slot Table.
SEQUENCE OF CpqSsIoSlotEntry
.1.3.6.1.4.1.232.8.2.2.2
cpqSsIoSlotEntryStorage System I/O Slot Entry.
CpqSsIoSlotEntry
.1.3.6.1.4.1.232.8.2.2.2.1
cpqSsIoSlotChassisIndexStorage System I/O Slot Chassis Index. The chassis index uniquely identifies a storage system chassis.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.2.1.1
cpqSsIoSlotIndexStorage System I/O Slot Index. This index uniquely identifies a storage system I/O Slot.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.2.1.2
cpqSsIoSlotControllerTypeStorage System I/O Slot Controller Type. The following values are defined: other(1) The agent is unable to determine if anything is installed in this storage system I/O slot. notInstalled(2) Nothing is installed in this storage system I/O slot. unknownBoardInstalled(3) An unknown controller is installed in this storage system I/O slot. fibreArray(4) A Fibre Channel Array controller is installed in this storage system I/O slot. scsiArray(5) A SCSI Array controller is installed in this storage system I/O slot. noSlot(6) The slot does not exist on this chassis. iScsiArray(7) An iSCSI Array controller is installed in this storage system I/O slot. sasArray(8) A SAS Array controller is installed in this storage system I/O slot.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.2.1.3
cpqSsPowerSupplyTableStorage System Power Supply Table.
SEQUENCE OF CpqSsPowerSupplyEntry
.1.3.6.1.4.1.232.8.2.2.3
cpqSsPowerSupplyEntryStorage System Power Supply Entry.
CpqSsPowerSupplyEntry
.1.3.6.1.4.1.232.8.2.2.3.1
cpqSsPowerSupplyChassisIndexStorage System Power Supply Chassis Index. The chassis index uniquely identifies a storage system chassis.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.3.1.1
cpqSsPowerSupplyIndexStorage System Power Supply Bay. This index uniquely identifies a power supply bay.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.3.1.2
cpqSsPowerSupplyBayStorage System Power Supply Bay. The following values are defined: other(1) The agent does not recognize the bay. You may need to upgrade your software. powerBay1(2) The power supply is installed in the first power supply bay. powerBay2(3) The power supply is installed in the second power supply bay. composite(4) The power supply information is a composite of all power supplies in the storage system.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.3.1.3
cpqSsPowerSupplyStatusStorage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply. degraded(5) For composite power supplies, this indicates that at least one power supply has failed or lost power.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.3.1.4
cpqSsPowerSupplyUpsStatusStorage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this power supply is attached to an Uninterruptible Power Supply (UPS). noUps(2) No UPS is attached to the power supply. ok(3) A UPS is attached to the power supply and is operating normally. powerFailed(4) A UPS is attached to the power supply and the AC power has failed. batteryLow(5) A UPS is attached to the power supply, the AC power has failed and the UPS battery is low.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.3.1.5
cpqSsPowerSupplyConditionStorage System Power Supply Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The power supply is operating normally. No user action is required. degraded(3) The power supply is degraded. You need to check the power supply or its attached UPS for problems. failed(4) The power supply has failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.3.1.6
cpqSsPowerSupplySerialNumberStorage System Power Supply Serial Number. This is the power supply's serial number. This can be used for identification purposes. If the serial number is not supported, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.3.1.7
cpqSsPowerSupplyBoardRevisionStorage System Power Supply Board Revision. This is the power supply board revision. If the board revision is not supported, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.3.1.8
cpqSsPowerSupplyFirmwareRevisionStorage System Power Supply Firmware Revision. This is the power supply firmware revision. If the firmware revision is not supported, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.3.1.9
cpqSsFanModuleTableStorage System Fan Module Table.
SEQUENCE OF CpqSsFanModuleEntry
.1.3.6.1.4.1.232.8.2.2.4
cpqSsFanModuleEntryStorage System Fan Module Entry.
CpqSsFanModuleEntry
.1.3.6.1.4.1.232.8.2.2.4.1
cpqSsFanModuleChassisIndexStorage System Fan Module Chassis Index. The chassis index uniquely identifies a storage system chassis.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.4.1.1
cpqSsFanModuleIndexStorage System Fan Module Index. This index uniquely identifies a storage system fan module.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.4.1.2
cpqSsFanModuleStatusStorage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage system fan module is installed. notInstalled(3) The fan module is not installed. ok(2) The fan module is installed and operating normally. degraded(4) The fan module degraded. failed(5) The fan module is failed. Replace the fan module.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.4.1.3
cpqSsFanModuleConditionStorage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.4.1.4
cpqSsFanModuleLocationStorage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system fan module. fanBay(2) This fan module is installed in the first fan bay. composite(3) The fan information is a composite of all fans in the storage system. fanBay2(4) This fan module is installed in the second fan bay.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.4.1.5
cpqSsFanModuleSerialNumberStorage System Fan Module Serial Number. This is the fan module's serial number. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.4.1.6
cpqSsFanModuleBoardRevisionStorage System Fan Module Board Revision. This is the fan module board revision.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.4.1.7
cpqSsTempSensorTableStorage System Temperature Sensor Table.
SEQUENCE OF CpqSsTempSensorEntry
.1.3.6.1.4.1.232.8.2.2.5
cpqSsTempSensorEntryStorage System Temperature Sensor Entry.
CpqSsTempSensorEntry
.1.3.6.1.4.1.232.8.2.2.5.1
cpqSsTempSensorChassisIndexStorage System Temperature Sensor Chassis Index. The chassis index uniquely identifies a storage system chassis.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.5.1.1
cpqSsTempSensorIndexStorage System Temperature Sensor Index. This index uniquely identifies a temperature sensor.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.5.1.2
cpqSsTempSensorStatusStorage System Temperature Sensor Status. The following values are defined: other(1) The agent is unable to determine if the storage system temperature sensor status. ok(2) The temperature is OK. degraded(3) The temperature is degraded. failed(4) The temperature is failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.5.1.3
cpqSsTempSensorConditionStorage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The temperature is within normal operating range. No user action is required. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.5.1.4
cpqSsTempSensorLocationStorage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system temperature sensor. fanBay(2) This temperature sensor is located on the fan module in the fan bay. backplane(3) This temperature is located on the SCSI drive backplane.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.5.1.5
cpqSsTempSensorCurrentValueStorage System Temperature Sensor Current Value. The current value of the temperature sensor in degrees Celsius.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.5.1.6
cpqSsTempSensorLimitValueStorage System Temperature Sensor Limit Value. The limit value of the temperature sensor in degrees Celsius.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.5.1.7
cpqSsTempSensorHysteresisValueStorage System Temperature Sensor Hysteresis Value. The hysteresis value of the temperature sensor in degrees Celsius.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.5.1.8
cpqSsBackplaneTableStorage System SCSI Backplane Table.
SEQUENCE OF CpqSsBackplaneEntry
.1.3.6.1.4.1.232.8.2.2.6
cpqSsBackplaneEntryStorage System SCSI Backplane Entry.
CpqSsBackplaneEntry
.1.3.6.1.4.1.232.8.2.2.6.1
cpqSsBackplaneChassisIndexStorage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.6.1.1
cpqSsBackplaneIndexStorage System Backplane Index. This index uniquely identifies a storage system backplane.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.6.1.2
cpqSsBackplaneFWRevStorage System Backplane Firmware Revision. This is the revision level of storage system backplane.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.6.1.3
cpqSsBackplaneDriveBaysStorage System Backplane Drive Bays. This is the number of bays on this storage system backplane.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.6.1.4
cpqSsBackplaneDuplexOptionStorage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.5
cpqSsBackplaneConditionStorage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. failed(4) The storage system has failed.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.6
cpqSsBackplaneVersionStorage System Backplane Version. This is the version of the drive box back plane.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.6.1.7
cpqSsBackplaneVendorStorage System Backplane Vendor This is the storage box's vendor name. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.6.1.8
cpqSsBackplaneModelStorage System Backplane Model. This is a description of the storage system's model. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.6.1.9
cpqSsBackplaneFanStatusStorage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system. degraded-Fan1Failed(7) Fan 1 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. degraded-Fan2Failed(8) Fan 2 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.10
cpqSsBackplaneTempStatusStorage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this storage system has temperature monitoring. noTemp(2) This unit does not support temperature monitoring. ok(3) The temperature is within normal operating range. degraded(4) The temperature is outside of normal operating range. failed(5) The temperature could permanently damage the system. notSupported(6) The storage system does not support reporting temperature status through this backplane. The temperature status is reported through the first backplane on this storage system.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.11
cpqSsBackplaneFtpsStatusStorage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value will be one of the following: other(1) The agent is unable to determine if this storage system has redundant power supplies. noFltTolPower(2) This unit does not have a redundant supply. ok(3) There are no detected power supply failures. degraded(4) One of the power supply units has failed. failed(5) All of the power supplies have failed. A status of failed can not currently be determined. notSupported(6) The storage system does not support reporting fault tolerant power supply status through this backplane. The fault tolerant power supply status is reported through the first backplane on this storage system. noFltTolPower-Bay1Missing(7), This unit does not have a redundant supply. The power supply in bay 1 is missing. noFltTolPower-Bay2Missing(8) This unit does not have a redundant supply. The power supply in bay 2 is missing.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.12
cpqSsBackplaneSerialNumberStorage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the front bezel. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.6.1.13
cpqSsBackplanePlacementStorage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.14
cpqSsBackplaneBoardRevisionStorage System Backplane Board Revision. This is the board revision of this storage system backplane.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.6.1.15
cpqSsBackplaneSpeedStorage System Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) This storage system is capable of Ultra3 speeds. ultra320(3) This storage system is capable of Ultra320 speeds. sata(4) This storage system is capable of SATA speeds.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.16
cpqSsBackplaneConnectionTypeBacklane Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this backplane. scsiAttached(2) This backplane is attached to the host via SCSI. sasAttached(3) This backplane is attached to the host via SAS.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.6.1.17
cpqSsBackplaneConnectorBackplane Connector. This is the connector to which the backplane is attached. If the backplane connector cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.6.1.18
cpqSsBackplaneOnConnectorBackplane on Connector. The backplane on connector indicates to which backplane instance this table entry belongs. The instances start at one and increment for each backplane attached to a connector.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.6.1.19
cpqSsBackplaneLocationStringBackplane Location String. This string describes the location of the backplane in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.2.6.1.20
cpqSsFibreAttachmentTableStorage System Fibre Attachment Table.
SEQUENCE OF CpqSsFibreAttachmentEntry
.1.3.6.1.4.1.232.8.2.2.7
cpqSsFibreAttachmentEntryStorage System Fibre Attachment Entry.
CpqSsFibreAttachmentEntry
.1.3.6.1.4.1.232.8.2.2.7.1
cpqSsFibreAttachmentIndexStorage System Fibre Attachment Index. The index uniquely identifies a Fibre Attachment association entry.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.7.1.1
cpqSsFibreAttachmentHostControllerIndexStorage System Fibre Attachment Host Controller Index. The host controller index indicates which host controller is associated with this entry. This is equal to cpqFcaHostCntlrIndex, from the Fibre Channel Host Controller Table.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.7.1.2
cpqSsFibreAttachmentHostControllerPortStorage System Fibre Attachment Host Controller Port. This is the Fibre port number of the host controller. For each host controller, the port number starts at 1 and increments for each port. This is currently set to 1.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.7.1.3
cpqSsFibreAttachmentDeviceTypeStorage System Fibre Attachment Device Type. This is the type of device associated with this entry. The following values are defined: other(1) The agent is unable to determine if the type of this device. storageBox(2) The device is a Fibre attached storage system. tapeController(3) The device is a Fibre attached tape controller. fibreChannelSwitch(4) The device is a Fibre channel switch.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.7.1.4
cpqSsFibreAttachmentDeviceIndexStorage System Fibre Attachment Device Index. The is the index for the Fibre attached device. For a Fibre attached storage system, this is equal to cpqSsChassisIndex from the Storage System Chassis Table. For a Fibre attached tape controller, this is equal to cpqFcTapeCntlrIndex from the Fibre Channel Tape Controller Table. For a Fibre channel switch, this is equal to cpqFcSwitchIndex from the Fibre Channel Switch Table.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.7.1.5
cpqSsFibreAttachmentDevicePortStorage System Fibre Attachment Device Port. This is the Fibre port on a device. For a Fibre attached storage system, this is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table. For a Fibre attached tape controller, this is currently set to 1. For a Fibre channel switch, this is currently set to 1.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.7.1.6
cpqSsScsiAttachmentTableStorage System SCSI Attachment Table.
SEQUENCE OF CpqSsScsiAttachmentEntry
.1.3.6.1.4.1.232.8.2.2.8
cpqSsScsiAttachmentEntryStorage System SCSI Attachment Entry.
CpqSsScsiAttachmentEntry
.1.3.6.1.4.1.232.8.2.2.8.1
cpqSsScsiAttachmentIndexStorage System SCSI Attachment Index. The index uniquely identifies a SCSI Attachment association entry.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.1
cpqSsScsiAttachmentControllerIndexStorage System SCSI Attachment Controller Index. The controller index indicates which internal array controller is associated with this entry. This is equal to cpqDaCntlrIndex, from the Array Controller Table.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.2
cpqSsScsiAttachmentControllerPortStorage System SCSI Attachment Controller Port. The controller port indicates which SCSI port of an internal controller is associated with this entry.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.3
cpqSsScsiAttachmentControllerTargetStorage System SCSI Attachment Controller Target. The controller target indicates which SCSI target is associated with this entry.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.4
cpqSsScsiAttachmentControllerLunStorage System SCSI Attachment Controller Lun. The controller Lun indicates which SCSI Lun is associated with this entry.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.5
cpqSsScsiAttachmentChassisIndexStorage System SCSI Attachment Chassis Index. The is the index for the SCSI attached storage system. This is equal to cpqSsChassisIndex from the Storage System Chassis Table.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.6
cpqSsScsiAttachmentChassisIoSlotStorage System SCSI Attachment Chassis I/O Slot. This is the I/O slot in the SCSI attached storage system. This is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table.ro
INTEGER
.1.3.6.1.4.1.232.8.2.2.8.1.7
cpqSsScsiAttachmentPathStatusStorage System SCSI Attachment Path Status. This is the status of this path to the chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The path is operating normally. offline(3) The path is offline.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.8.1.8
cpqSsScsiAttachmentPathConditionStorage System SCSI Attachment Path Condition. This is the condition of this path to the chassis.ro
Enumeration
.1.3.6.1.4.1.232.8.2.2.8.1.9
cpqSsDrvBoxPathTableDrive Box Access Path Table.
SEQUENCE OF CpqSsDrvBoxPathEntry
.1.3.6.1.4.1.232.8.2.3
cpqSsDrvBoxPathEntryDrive Box Access Path Entry.
CpqSsDrvBoxPathEntry
.1.3.6.1.4.1.232.8.2.3.1
cpqSsDrvBoxPathCntlrIndexDrive Box Access Path Controller Index. The controller index indicates to which adapter card instance this table entry belongs.ro
INTEGER
.1.3.6.1.4.1.232.8.2.3.1.1
cpqSsDrvBoxPathBoxIndexDrive Box Access Path Box Index. The box index indicates to which box instance on an adapter card this table entry belongs. The value of this index is the same as cpqSsDrvBoxBusIndex used under the drive box table.ro
INTEGER
.1.3.6.1.4.1.232.8.2.3.1.2
cpqSsDrvBoxPathIndexDrive Box Access Path Index. This path index keeps track of multiple instances of access paths from a controller to a storage box. This number, along with the cpqSsDrvBoxPathCntlrIndex and cpqSsDrvBoxPathDrvIndex uniquely identify a specific storage box access pathro
INTEGER
.1.3.6.1.4.1.232.8.2.3.1.3
cpqSsDrvBoxPathStatusDrive Box Access Path Status. This shows the status of the drive box access path. The following values are valid: Other (1) Indicates that the instrument agent can not determine the status of this access path. OK (2) Indicates the access path is functioning properly. Link Down (3) Indicates that the controller can no longer access the drive box through this path.ro
Enumeration
.1.3.6.1.4.1.232.8.2.3.1.4
cpqSsDrvBoxPathCurrentRoleDrive Box Access Path Current Role. This shows the current role of drive box acess path. The following values are valid: Other (1) Indicates that the instrument agent does not recognize the role of this access path. Active (2) Indicates that this path is currently the default active I/O path to access the drive box from the controller. Alternate (3) Indicates that this path is currently the alternate I/O path to access the physical drive from the controller.ro
Enumeration
.1.3.6.1.4.1.232.8.2.3.1.5
cpqSsDrvBoxPathHostConnectorDrive Box Access Path Host Connector. This is the host connector to which the access path is ultimately attached. If the host connector cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.3.1.6
cpqSsDrvBoxPathBoxOnConnectorDrive Box Access Path Box on Connector. The box on connector indicates to which box instance this access path belongs.ro
INTEGER
.1.3.6.1.4.1.232.8.2.3.1.7
cpqSsDrvBoxPathLocationStringDrive Box Access Path Location String. This string describes drive box access path in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.ro
DisplayString
.1.3.6.1.4.1.232.8.2.3.1.8
cpqSsTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.232.8.3
cpqSsTrapPktsThe total number of trap packets issued by the enterprise since the instrument agent was loaded.rodeprecated
Counter
.1.3.6.1.4.1.232.8.3.1
cpqSsTrapLogMaxSizeThe maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be removed.rodeprecated
INTEGER
.1.3.6.1.4.1.232.8.3.2
cpqSsTrapLogTableAn ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent trap at index 1 and the oldest trap entry at index trapLogMaxSize. If the maximum number size has been reached and a new trap occurs the oldest trap will be removed when the new trap is added so the trapMaxLogSize is not exceeded.deprecated
SEQUENCE OF CpqSsTrapLogEntry
.1.3.6.1.4.1.232.8.3.3
cpqSsTrapLogEntryA description of a trap event.deprecated
CpqSsTrapLogEntry
.1.3.6.1.4.1.232.8.3.3.1
cpqSsTrapLogIndexThe value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMaxSize. Because of the queue-like nature of the trapLog this particular trap event's index will change as new traps are issued.rodeprecated
INTEGER
.1.3.6.1.4.1.232.8.3.3.1.1
cpqSsTrapTypeThe type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the agent may issue.rodeprecated
Enumeration
.1.3.6.1.4.1.232.8.3.3.1.2
cpqSsTrapTimeThe time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Each octet gives the value in BCD.rodeprecated
OCTET STRING
.1.3.6.1.4.1.232.8.3.3.1.3
cpqSsRaidSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.232.8.4
cpqSsRaidSystemTableRAID Storage System Table.
SEQUENCE OF CpqSsRaidSystemEntry
.1.3.6.1.4.1.232.8.4.1
cpqSsRaidSystemEntryRAID Storage System Entry.
CpqSsRaidSystemEntry
.1.3.6.1.4.1.232.8.4.1.1
cpqSsRaidSystemIndexRAID Storage System Index. The RAID Storage System index indicates to which storage system instance this table entry belongs.ro
INTEGER
.1.3.6.1.4.1.232.8.4.1.1.1
cpqSsRaidSystemNameRAID Storage System Name. This is a description of the RAID Storage System's name. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.4.1.1.2
cpqSsRaidSystemStatusRAID Storage System Status. This is the current status of the RAID Storage System. This value will be one of the following: other(1) Indicates that the agent does not recognize the state of the RAID Storage System. You may need to upgrade the agent. agentNotRunning(2) Indicates that the Storage Work agent is not running. You need to restart the Storage Work agent. good(3) Indicates that the system is operating properly. warning(4) At least one component of the system failed. communicationLoss(5) The RAID Storage System has a cable or communication problem. Please check all cable connects to the host server.ro
Enumeration
.1.3.6.1.4.1.232.8.4.1.1.3
cpqSsRaidSystemConditionRAID Storage System Condition. This is the overall condition of the storage system. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. At least one component of the storage system failed. failed(4) The storage system has failed.ro
Enumeration
.1.3.6.1.4.1.232.8.4.1.1.4
cpqSsRaidSystemCntlr1SerialNumberRAID Storage System Controller 1 Serial Number. This is the controller number 1's serial number which is normally display on the front panel. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.4.1.1.5
cpqSsRaidSystemCntlr2SerialNumberRAID Storage System Controller 2 Serial Number. This is the controller number 2's serial number which is normally display on the front panel. This can be used for identification purposes.ro
DisplayString
.1.3.6.1.4.1.232.8.4.1.1.6