CPQSCSI-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for CPQSCSI-MIB.
342
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
342 total| Object Name |
|---|
cpqScsi2CntlrStatusChangeSCSI Controller Status Change.
The agent has detected a change in the controller
status of a SCSI Controller. The variable
cpqScsiCntlrStatus indicates the current controller status. TRAP-TYPE .1.3.6.1.4.1.232.0.5001 |
cpqScsi2LogDrvStatusChangeLogical Drive Status Change.
The agent has detected a change in the Logical Drive
Status of a SCSI logical drive. The current logical
drive status is indicated by the cpqScsiLogDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5002 |
cpqScsi2PhyDrvStatusChangePhysical Drive Status Change.
The agent has detected a change in the status of a
SCSI physical drive. The current physical drive
status is indicated in the cpqScsiPhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5003 |
cpqTapePhyDrvStatusChangeTape Drive Status Change.
The agent has detected a change in the status of a
Tape drive. The current physical drive status is
indicated in the cpqTapePhyDrvCondition variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5004 |
cpqScsi3CntlrStatusChangeSCSI Controller Status Change.
The agent has detected a change in the controller
status of a SCSI Controller. The variable
cpqScsiCntlrStatus indicates the current controller status. TRAP-TYPE .1.3.6.1.4.1.232.0.5005 |
cpqScsi3PhyDrvStatusChangePhysical Drive Status Change.
The agent has detected a change in the status of a
SCSI physical drive. The current physical drive
status is indicated in the cpqScsiPhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5006 |
cpqTape3PhyDrvStatusChangeTape Drive Status Change.
The agent has detected a change in the status of a
Tape drive. The current physical drive status is
indicated in the cpqTapePhyDrvCondition variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5007 |
cpqTape3PhyDrvCleaningRequiredTape Drive Cleaning Required trap.
The agent has detected a tape drive that needs to have
a cleaning tape inserted and run. This will cause the tape drive
heads to be cleaned. TRAP-TYPE .1.3.6.1.4.1.232.0.5008 |
cpqTape3PhyDrvCleanTapeReplaceTape Drive Cleaning Tape Needs Replacing.
The agent has detected that an autoloader tape unit has
a cleaning tape that has been fully used and therefore needs to
be replaced with a new cleaning tape. TRAP-TYPE .1.3.6.1.4.1.232.0.5009 |
cpqTape3LibraryFailedTape Library Error
The agent has detected that an autoloader unit has
an encountered an error. TRAP-TYPE .1.3.6.1.4.1.232.0.5010 |
cpqTape3LibraryOkayTape Library Okay
The agent has detected that an autoloader unit has
recovered from errors. TRAP-TYPE .1.3.6.1.4.1.232.0.5011 |
cpqTape3LibraryDegradedTape Library Degraded
The agent has detected that an autoloader unit is
in a degraded condition. TRAP-TYPE .1.3.6.1.4.1.232.0.5012 |
cpqTape3LibraryDoorOpenTape Library Door Open
The agent has detected that the door on an autoloader
is open so the unit is not operational. TRAP-TYPE .1.3.6.1.4.1.232.0.5013 |
cpqTape3LibraryDoorClosedTape Library Door Closed
The agent has detected that the door on a an autoloader
has closed. TRAP-TYPE .1.3.6.1.4.1.232.0.5014 |
cpqScsiCdLibraryStatusChangeCD Library Status Change.
The agent has detected a change in the status of a
CD Library device. The current CD Library status is
indicated in the cpqScsiCdLibraryCondition variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5015 |
cpqTape4PhyDrvStatusChangeTape Drive Status Change.
The Storage Agent has detected a change in the status of a
Tape drive. The current physical drive status is
indicated in the cpqTapePhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5016 |
cpqScsi4PhyDrvStatusChangePhysical Drive Status Change.
The Storage Agent has detected a change in the status of a
SCSI physical drive. The current physical drive
status is indicated in the cpqScsiPhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5017 |
cpqTapeLibraryStatusChangeTape Library Status Change
The Storage Agent has detected a change in the status of a
tape library. The current tape library status is
indicated in the cpqTapeLibraryState variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5018 |
cpqTape5PhyDrvStatusChangeTape Drive Status Change.
The Storage Agent has detected a change in the status of a
tape drive. The current physical drive status is
indicated in the cpqTapePhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5019 |
cpqScsi5PhyDrvStatusChangePhysical Drive Status Change.
The Storage Agent has detected a change in the status of a
SCSI physical drive. The current physical drive
status is indicated in the cpqScsiPhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5020 |
cpqScsi3LogDrvStatusChangeLogical Drive Status Change.
The Storage Agent has detected a change in the status of a
SCSI logical drive. The current logical drive status is
indicated in the cpqScsiLogDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5021 |
cpqSasPhyDrvStatusChangePhysical Drive Status Change.
The Storage Agent has detected a change in the status of a
SAS or SATA physical drive. The current physical drive status
is indicated in the cpqSasPhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5022 |
cpqSasLogDrvStatusChangeLogical Drive Status Change.
The Storage Agent has detected a change in the status of a
SAS or SATA logical drive. The current logical drive status is
indicated in the cpqSasLogDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5023 |
cpqSas2TapeDrvStatusChangeSAS Tape Drive Status Change.
The Storage Agent has detected a change in the status of a
SAS tape drive. The current tape drive status is
indicated in the cpqSasTapeDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.0.5025 |
cpqScsi OBJECT IDENTIFIER .1.3.6.1.4.1.232.5 |
RFC1213-MIB Unknown .1.3.6.1.4.1.232.5 |
cpqScsiCntlrStatusChangeSCSI Controller Status Change.
The agent has detected a change in the controller
status of a SCSI Controller. The variable
cpqScsiCntlrStatus indicates the current controller status. TRAP-TYPE .1.3.6.1.4.1.232.5.0.1 |
cpqScsiLogDrvStatusChangeLogical Drive Status Change.
The agent has detected a change in the Logical Drive
Status of a SCSI logical drive. The current logical
drive status is indicated by the cpqScsiLogDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.5.0.2 |
cpqScsiPhyDrvStatusChangePhysical Drive Status Change.
The agent has detected a change in the status of a
SCSI physical drive. The current physical drive
status is indicated in the cpqScsiPhyDrvStatus variable. TRAP-TYPE .1.3.6.1.4.1.232.5.0.3 |
cpqScsiMibRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.1 |
cpqScsiMibRevMajorThe Major Revision level.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level.ro INTEGER .1.3.6.1.4.1.232.5.1.1 |
cpqScsiMibRevMinorThe Minor Revision level.
A change in the minor revision level may represent some minor
additional support; no changes to any pre-existing information
has occurred.ro INTEGER .1.3.6.1.4.1.232.5.1.2 |
cpqScsiMibConditionThe overall condition.
This object represents the overall status of the SCSI system
represented by this MIB.ro Enumeration .1.3.6.1.4.1.232.5.1.3 |
cpqScsiComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2 |
cpqScsiInterface OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.1 |
cpqScsiOsNetWare OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.1.1 |
cpqScsiNw3xDriverNameSCSI Drive Device Driver Name.
This is the name of the NetWare v3.1x SCSI device driver. It
can be used for identification purposes.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.1 |
cpqScsiNw3xDriverVersSCSI Drive Device Driver Version.
This is the version of the NetWare v3.1x SCSI device driver.
It can be used for identification purposes.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.2 |
cpqScsiNw3xDriverPollTypeSCSI Drive Device Driver Poll Type.
The SNMP instrument agent collects information from the
device driver in two ways:
other(1)
The management agent does not recognize this poll type.
You may need to upgrade your software.
polled(2)
Indicates that the information is periodically requested and
stored by the server based agent and is available when
requested.
demand(3)
Indicates that the information is collected at the time of the
request.rodeprecated Enumeration .1.3.6.1.4.1.232.5.2.1.1.3 |
cpqScsiNw3xDriverPollTimeSCSI Drive Device Driver Poll Time.
If the nw3xDriverPollType is polled(2) this value shows
how frequently, in seconds, the instrument agent requests
information from the device driver.
To change the poll time, you need to unload and then reload the
instrument agent using the following commands:
UNLOAD CPQDSKSA
LOAD CPQDSKSA /U<time>
The parameter /U specifies the frequency of updates in seconds.
The variable <time> represents the number of seconds that the
NLM should wait before collecting new data. The minimum is one
second and the maximum value is 300 seconds (five minutes).rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.4 |
cpqScsiNw3xCntlrInfoTableSCSI Controller Information Table.deprecated SEQUENCE OF CpqScsiNw3xCntlrInfoEntry .1.3.6.1.4.1.232.5.2.1.1.5 |
cpqScsiNw3xCntlrInfoEntrySCSI Controller Information Table Entry.deprecated CpqScsiNw3xCntlrInfoEntry .1.3.6.1.4.1.232.5.2.1.1.5.1 |
cpqScsiNw3xCntlrIndexSCSI Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.5.1.1 |
cpqScsiNw3xBusIndexSCSI Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on an adapter.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.5.1.2 |
cpqScsiNw3xXptDescSCSI XPT Description.
This is a description of the Transport Layer (XPT) module,
CPQSXPT.DSK. The Transport Layer manages requests from the
device driver and routes them to the appropriate SCSI Interface
Module (SIM). This architecture is based on the ANSI SCSI-2
Common Access Method (CAM) specification.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.5.1.3 |
cpqScsiNw3xXptVersSCSI XPT Version.
This is the version of the Transport Layer (XPT) module,
CPQSXPT.DSK. The Transport Layer manages requests from the
device driver and routes them to the appropriate SCSI Interface
Module (SIM). This architecture is based on the ANSI SCSI-2
Common Access Method (CAM) specification.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.5.1.4 |
cpqScsiNw3xSimDescSCSI SIM Description.
This is a description of the SCSI Interface Module (SIM).
Each type of controller model has a specific SIM designed for it.
The SIM accepts requests from the Transport Layer and delivers
them to the physical device. This architecture is based on the
ANSI SCSI-2 Common Access Method (CAM) specification.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.5.1.5 |
cpqScsiNw3xSimVersSCSI SIM Version.
This is the version of the SCSI Interface Module (SIM).
Each type of controller model has a specific SIM designed for it.
The SIM accepts requests from the Transport Layer and delivers
them to the physical device. This architecture is based on the
ANSI SCSI-2 Common Access Method (CAM) specification.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.5.1.6 |
cpqScsiNw3xHbaDescSCSI HBA Description.
This is a description of the SCSI Host Bus Adapter (HBA).
An HBA represents one instance of a SCSI bus in the SCSI
Interface Module (SIM). This architecture is based on the
ANSI SCSI-2 Common Access Method (CAM) specification.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.1.5.1.7 |
cpqScsiLogDrvStatTableSCSI Logical Drive Statistics Table.deprecated SEQUENCE OF CpqScsiLogDrvStatEntry .1.3.6.1.4.1.232.5.2.1.1.6 |
cpqScsiLogDrvStatEntrySCSI Device Driver Statistics Table Entry.deprecated CpqScsiLogDrvStatEntry .1.3.6.1.4.1.232.5.2.1.1.6.1 |
cpqScsiNw3xStatCntlrIndexSCSI Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.6.1.1 |
cpqScsiNw3xStatBusIndexSCSI Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.6.1.2 |
cpqScsiNw3xStatLogDrvIndexSCSI Logical Drive Index.
The logical drive index indicates to which logical drive
instance on a SCSI bus this table entry belongs. The logical
drive index starts at one and increments for each logical drive
on the SCSI bus.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.6.1.3 |
cpqScsiNw3xTotalReadsSCSI Logical Drive Total Reads.
This shows the total number of reads performed by the device
driver to this logical drive. This number is reset each time the
device driver is loaded for this logical drive.rodeprecated Counter .1.3.6.1.4.1.232.5.2.1.1.6.1.4 |
cpqScsiNw3xTotalWritesSCSI Logical Drive Total Writes.
This shows the total number of writes performed by the device
driver to this logical drive. This number is reset each time the
device driver is loaded for this logical drive.rodeprecated Counter .1.3.6.1.4.1.232.5.2.1.1.6.1.5 |
cpqScsiNw3xCorrReadsSCSI Logical Drive Corrected Reads.
This is the total number of read commands sent to the specified
logical drive which had to be corrected by fault tolerance.
This number is reset each time the device driver is loaded for
this logical drive.rodeprecated Counter .1.3.6.1.4.1.232.5.2.1.1.6.1.6 |
cpqScsiNw3xCorrWritesSCSI Logical Drive Corrected Writes.
This is the total number of write commands sent to the specified
logical drive which had to be corrected by fault tolerance.
This number is reset each time the device driver is loaded for
this logical drive.rodeprecated Counter .1.3.6.1.4.1.232.5.2.1.1.6.1.7 |
cpqScsiNw3xFatalReadsSCSI Logical Drive Fatal Reads.
This is the total number of read commands sent to the specified
logical drive which failed. This number is reset each time the
device driver is loaded for this logical drive.rodeprecated Counter .1.3.6.1.4.1.232.5.2.1.1.6.1.8 |
cpqScsiNw3xFatalWritesSCSI Logical Drive Fatal Writes.
This is the total number of write commands sent to the specified
logical drive which failed. This number is reset each time the
device driver is loaded for this logical drive.rodeprecated Counter .1.3.6.1.4.1.232.5.2.1.1.6.1.9 |
cpqScsiVolMapTableSCSI Drive Volume Map Table.deprecated SEQUENCE OF CpqScsiVolMapEntry .1.3.6.1.4.1.232.5.2.1.1.7 |
cpqScsiVolMapEntrySCSI Drive Volume Map Table Entry.deprecated CpqScsiVolMapEntry .1.3.6.1.4.1.232.5.2.1.1.7.1 |
cpqScsiNw3xVolCntlrIndexSCSI Cntlr Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.7.1.1 |
cpqScsiNw3xVolBusIndexSCSI Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.7.1.2 |
cpqScsiNw3xVolLogDrvIndexSCSI Logical Drive Index.
The logical drive index indicates to which logical drive
instance on a SCSI bus this table entry belongs. The logical
drive index starts at one and increments for each logical
drive on the SCSI bus.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.1.7.1.3 |
cpqScsiNw3xVolMapSCSI Drive Volume Map.
This is a data structure containing the volume mappings for this
logical drive. There are 8 entries in a NetWare volume mapping.
An entry can be null indicating no mapping exists.
Each entry has the following format.
BYTE Name[16]
BYTE Segmentrodeprecated OCTET STRING .1.3.6.1.4.1.232.5.2.1.1.7.1.4 |
cpqScsiOsCommon OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.1.4 |
cpqScsiOsCommonPollFreqThe agent's polling frequency.
The frequency, in seconds, at which the agent requests
information from the device driver. A frequency of zero
indicates that the agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
agent. Setting the poll frequency to zero will always
fail, an agent may also choose to fail any request to change
the poll frequency to a value that would severely impact system
performance.rw INTEGER .1.3.6.1.4.1.232.5.2.1.4.1 |
cpqScsiOsCommonModuleTableA table of software modules that provide an interface to the
device this MIB describes.deprecated SEQUENCE OF CpqScsiOsCommonModuleEntry .1.3.6.1.4.1.232.5.2.1.4.2 |
cpqScsiOsCommonModuleEntryA description of a software modules that provide an interface
to the device this MIB describes.deprecated CpqScsiOsCommonModuleEntry .1.3.6.1.4.1.232.5.2.1.4.2.1 |
cpqScsiOsCommonModuleIndexA unique index for this module description.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.1.4.2.1.1 |
cpqScsiOsCommonModuleNameThe module name.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.4.2.1.2 |
cpqScsiOsCommonModuleVersionThe module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be a null (size 0) string if the agent
cannot provide the module version.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.4.2.1.3 |
cpqScsiOsCommonModuleDateThe module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octect first.rodeprecated OCTET STRING .1.3.6.1.4.1.232.5.2.1.4.2.1.4 |
cpqScsiOsCommonModulePurposeThe purpose of the module described in this entry.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.1.4.2.1.5 |
cpqScsiCntlr OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.2 |
cpqScsiCntlrTableSCSI Controller Table. SEQUENCE OF CpqScsiCntlrEntry .1.3.6.1.4.1.232.5.2.2.1 |
cpqScsiCntlrEntrySCSI Controller Table Entry. CpqScsiCntlrEntry .1.3.6.1.4.1.232.5.2.2.1.1 |
cpqScsiCntlrIndexSCSI Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.2.2.1.1.1 |
cpqScsiCntlrBusIndexSCSI Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.2.2.1.1.2 |
cpqScsiCntlrModelSCSI Controller Model.
The is the controller's model and can be used for identification
purposes. The following values are defined:
other(1) The management agent does not recognize this model.
You may need to upgrade your software.
cpqs710(2) Compaq 32-Bit Fast SCSI-2 Controller.
cpqs94(3) Compaq Systempro/XL Integrated SCSI-2 Options Port.
cpqs810p(4) Integrated Fast-SCSI-2 Controller/P.
cpqs825e(5) Compaq 32-Bit Fast-Wide SCSI-2 /E Controller.
cpqs825p(6) Compaq 32-Bit Fast-Wide SCSI-2 /P Controller.
cpqs974p(7) Deskpro XL Integrated PCI SCSI-2 Controller.
cpqs875p(8) Compaq Wide-Ultra SCSI Controller.
extended(9) SCSI Controllers described by
cpqScsiCntlrModelExtended.
cpqs895p(10) Compaq Wide Ultra2 SCSI Controller.
cpqs896p(11) Compaq 64-Bit Dual Channel Wide Ultra2 SCSI
Controller.
cpqa789x(12) Compaq Wide Ultra3 SCSI Adapter.
cpqs876t(13) Compaq StorageWorks Library Adapter.
hpu320(14) HP 64-Bit/133MHz PCI-X 2CH Ultra320 HBA.
hpu320r(15) HP PCI-X Dual Channel Ultra320 SCSI Adapter.
generic(16) SCSI HBA.
hp1u320g2(17) HP Single Channel Ultra320 SCSI HBA G2.
hp1u320g1(18) HP Single Channel Ultra320 SCSI HBA.
hpSc11Xe(19) HP SC11Xe Host Bus Adapter.ro Enumeration .1.3.6.1.4.1.232.5.2.2.1.1.3 |
cpqScsiCntlrFWVersSCSI Controller Firmware Version.
This is the version of the firmware on the SCSI controller.
If the SCSI controller does not use firmware then this string
will be of length zero (0). Some SCSI bus controllers are
script driven and use the computer system's microprocessor
thus not needing firmware.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.5.2.2.1.1.4 |
cpqScsiCntlrSWVersSCSI Controller Software Version.
This is the version of any software upgrade which is being used
in place of the firmware with the controller. If the SCSI
controller has not been upgraded via software or does not have
firmware then this string will be of length zero (0).
Some SCSI bus controllers are script driven and use the
computer system's microprocessor thus not needing firmware.rodeprecated DisplayString .1.3.6.1.4.1.232.5.2.2.1.1.5 |
cpqScsiCntlrSlotSCSI Controller Slot.
This is the physical slot in which this controller is
installed. This information can be used for identification
purposes.ro INTEGER .1.3.6.1.4.1.232.5.2.2.1.1.6 |
cpqScsiCntlrStatusSCSI Controller Status.
This is the current status of the controller. The following
values are currently defined:
other(1)
The controller is not operational due to reasons other than
hardware failure. The controller may be intentionally disabled.
The controller configuration may be in conflict with the
configuration of other hardware or software in the system.
The controller may have failed initialization. Corrective
action is Operating System dependent. Check for diagnostic
messages which may have occurred at system boot time.
ok(2)
The controller is operating normally.
failed(3)
The controller has failed and is no longer operating.
Please run diagnostics on the computer system to help
identify the problem.ro Enumeration .1.3.6.1.4.1.232.5.2.2.1.1.7 |
cpqScsiCntlrHardResetsSCSI Controller Hard Resets.
This is the number of times the SCSI Hardware Interface driver
detected that the SCSI bus has been reset since the driver
was loaded.
Hard resets may occasionally occur due to device errors.
If this value should rise dramatically, you may have a problem.
Check the SCSI bus statistics for unusually high error counts.
If there is a device with a large number of bus errors, it may be
failing and should be replaced.ro Counter .1.3.6.1.4.1.232.5.2.2.1.1.8 |
cpqScsiCntlrSoftResetsSCSI Controller Soft Resets.
This is the number of times the SCSI Hardware Interface driver
has issued a reset command to all devices on a SCSI bus since
the driver was loaded.
Soft resets occur when the device driver is initializing the SCSI
bus for operation and when device errors have left the bus in an
ambiguous state. If this value should rise dramatically, you may
have a problem. Check the SCSI bus statistics for unusually high
error counts. If there is a device with a large number of bus
errors, it may be failing and should be and should be replaced.ro Counter .1.3.6.1.4.1.232.5.2.2.1.1.9 |
cpqScsiCntlrTimeoutsSCSI Controller Time-outs.
This is the number of times, since the driver was loaded, that
the SCSI Hardware Interface driver issued a SCSI command but
did not receive a reply within a specified amount of time.
Timeouts may occasionally occur when a device fails to process a
request because the SCSI bus was busy. If this value should rise
dramatically, you may have a problem. Check if you have any
non-disk SCSI devices, like tape drives, on the SCSI bus with
the drives. Sometimes a non-disk device can hold the SCSI bus
for long periods of time causing time-outs.ro Counter .1.3.6.1.4.1.232.5.2.2.1.1.10 |
cpqScsiCntlrBaseIOAddrSCSI Controller Base I/O Address.
This is the I/O address that the SCSI Hardware Interface driver
uses to communicate with the SCSI bus controller. This value
can be used for identification purposes.ro INTEGER .1.3.6.1.4.1.232.5.2.2.1.1.11 |
cpqScsiCntlrConditionSCSI Controller Condition.
This is the overall condition of the controller and all of the
logical drives and physical drives controlled by it.
The following values are defined:
other(1)
The management agent does not recognize the status as one of
those listed below.
ok(2)
The controller and all of its logical drives and physical
drives are operating normally. No user action is required.
degraded(3)
One or more of the controller's logical drives or physical
drives is degraded. You need to check the status of all
logical drives and physical drives.
failed(4)
The controller status is failed. The drives on this
controller are inaccessible. Please refer to the controller
status field for further information.ro Enumeration .1.3.6.1.4.1.232.5.2.2.1.1.12 |
cpqScsiCntlrSerialNumSCSI Controller Serial Number.
This is the serial number assigned to the controller. This can
be used for identification purposes. This field will be a null
(size 0) string if the management agent cannot provide the
serial number.ro DisplayString .1.3.6.1.4.1.232.5.2.2.1.1.13 |
cpqScsiCntlrBusWidthSCSI Controller Data Bus Width.
This is the physical width of the controller's SCSI data bus.
other(1)
The management agent does not recognize this width. You may
need to upgrade your software.
narrow(2)
The SCSI controller supports an 8-bit narrow SCSI data bus.
wide16(3)
The SCSI controller supports a 16-bit wide SCSI data bus.ro Enumeration .1.3.6.1.4.1.232.5.2.2.1.1.14 |
cpqScsiCntlrModelExtendedSCSI Controller Model Name.
This is the model name for SCSI controllers not defined by
cpqScsiCntlrModel enumerations. This field will be a null (size 0)
string if the management agent cannot provide the SCSI Controller
description.ro DisplayString .1.3.6.1.4.1.232.5.2.2.1.1.15 |
cpqScsiCntlrHwLocationA text description of the hardware location, on complex
multi SBB hardware only, for the SCSI controller.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.5.2.2.1.1.16 |
cpqScsiLogDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.3 |
cpqScsiLogDrvTableSCSI Logical Drive Table. SEQUENCE OF CpqScsiLogDrvEntry .1.3.6.1.4.1.232.5.2.3.1 |
cpqScsiLogDrvEntrySCSI Logical Drive Entry. CpqScsiLogDrvEntry .1.3.6.1.4.1.232.5.2.3.1.1 |
cpqScsiLogDrvCntlrIndexSCSI Logical Drive Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.2.3.1.1.1 |
cpqScsiLogDrvBusIndexSCSI Logical Drive Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.2.3.1.1.2 |
cpqScsiLogDrvIndexSCSI Logical Drive Index.
The logical drive index indicates to which logical drive instance
on a SCSI bus this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.2.3.1.1.3 |
cpqScsiLogDrvFaultTolSCSI Logical Drive Fault Tolerance.
This shows the fault tolerance mode of the logical drive.
The following values are valid for the Logical Drive
Fault Tolerance:
other(1)
The management agent does not recognize the status.
You may need to upgrade your software.
none(2)
Fault tolerance is not enabled. If a physical drive reports an
error, the data cannot be recovered. This is known as RAID 0.
mirroring(3)
For each physical drive, there is a second physical drive
containing identical data. If a drive fails, the data can be
retrieved from the mirror drive.
dataGuard(4)
One of the physical drives is used as a data guard drive and
contains the exclusive OR of the data on the remaining drives.
If a failure is detected, the data is rebuilt using the data
guard information plus information from the other drives.
distribDataGuard(5)
Distributed Data Guarding, sometimes referred to as RAID 5, is
similar to Data Guarding, but instead of storing the parity
information on one drive, the information is distributed across
all of the drives. If a failure is detected, the data is
rebuilt using the data guard information from all the drives.
enhancedMirroring(6)
This is used when there are more than 2 physical disks. Each
'mirrored stripe' is written to a disk and is mirrored to an
'adjacent' disk. This is commonly referred to as RAID 1E.
If a failure is detected, the data is rebuilt using the data
from the mirrored stripes on the other drives.ro Enumeration .1.3.6.1.4.1.232.5.2.3.1.1.4 |
cpqScsiLogDrvStatusSCSI Logical Drive Status.
The logical drive can be in one of the following states:
other(1)
The management agent does not recognize the status.
You may need to upgrade your software.
ok(2)
Indicates that the logical drive is in normal operation mode.
No user action is required.
failed(3)
Indicates that more physical drives have failed than the fault
tolerance mode of the logical drive can handle without data loss.
unconfigured(4)
Indicates that the logical drive is not configured. Insure all
of the drive switches are properly set and run the configuration
utility.
recovering(5)
Indicates that the logical drive is using Interim Recovery Mode.
In Interim Recovery Mode, at least one physical drive has
failed, but the logical drive's fault tolerance mode lets the
logical drive continue to operate with no data loss.
You should replace the failed drive as soon as possible.
readyRebuild(6)
Indicates that the logical drive is ready for Automatic Data
Recovery. The physical drive that failed has been replaced,
but the logical drive is still operating in Interim Recovery
Mode.
rebuilding(7)
Indicates that the logical drive is currently resynchronizing
the data accross the physical drives in the logical drive.
wrongDrive(8)
Indicates that the wrong physical drive was replaced after a
physical drive failure. You need to return the drive
incorrectly replaced and replace the failed drive.
badConnect(9)
Indicates that a physical drive is not responding. Check the
cables connected to it.
degraded(10)
Indicates that the logical drive is in a degraded state.
disabled(11)
Indicates that the logical drive is disabled. The logical drive
configuration utility can enable or disable the logical drive.
You should enable the logical drive using the configuration
utility.ro Enumeration .1.3.6.1.4.1.232.5.2.3.1.1.5 |
cpqScsiLogDrvSizeSCSI Logical Drive Size.
This is the size of the logical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as
a megabyte. Drive manufacturers sometimes use the
number 1,000,000 as a megabyte when giving drive capacities
so this value may differ from the advertised size of a drive.ro INTEGER .1.3.6.1.4.1.232.5.2.3.1.1.6 |
cpqScsiLogDrvPhyDrvIDsSCSI Logical Drive Physical Drive IDs.
This lists the physical drive SCSI ID's which are associated
with this logical drive. These are the same IDs which can be
used as indices into the physical drive table. Each byte of
the string is an index.ro OCTET STRING .1.3.6.1.4.1.232.5.2.3.1.1.7 |
cpqScsiLogDrvConditionSCSI Logical Drive Condition.
This is the overall condition of the logical drive and all of the
physical drives which comprise it.
The following values are defined:
other(1)
The management agent does not recognize the status. You may
need to upgrade your software.
ok(2)
The logical drive and all of its physical drives are operating
normally. No user action is required.
degraded(3)
Either the logical drive is degraded or one or more of its
physical drives is degraded. You need to check the status
of the logical drive and of all its physical drives.
failed(4)
Either the logical drive has failed or one or more of its
physical drives has failed. You need to check the status
of the logical drive and of all its physical drives.ro Enumeration .1.3.6.1.4.1.232.5.2.3.1.1.8 |
cpqScsiLogDrvStripeSizeLogical Drive Stripe Size.
This is the size of a logical drive stripe in kilobytes.ro INTEGER .1.3.6.1.4.1.232.5.2.3.1.1.9 |
cpqScsiLogDrvAvailSparesSCSI Logical Drive Available Spares.
This indicates if this logical drive has one or more spares
designated for it that are not currently in use by another drive.
Each octet present will be a physical drive ID that is an
available spare for this logical drive. These are the same ID's
which can be used as indexes into the physical drive table.
An octet string of length zero indicates that there are no
available spares for this logical drive.ro OCTET STRING .1.3.6.1.4.1.232.5.2.3.1.1.10 |
cpqScsiLogDrvPercentRebuildLogical Drive Percent Rebuild.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value is the percent
complete of the rebuild. When the value reaches 100, the
rebuilding process is complete. The drive array continues to
operate in interim recovery mode while a drive is rebuilding.
This value is only valid if the Logical Drive Status is
rebuilding(7).
If the value cannot be determined or a rebuild is not active,
the value is set to 0.ro Gauge .1.3.6.1.4.1.232.5.2.3.1.1.11 |
cpqScsiLogDrvOsNameLogical Drive OS Name.
The OS name for this array logical drive. This field will be
a null (size 0) string if the agent does not support OS name.ro DisplayString .1.3.6.1.4.1.232.5.2.3.1.1.12 |
cpqScsiPhyDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.4 |
cpqScsiPhyDrvTableSCSI Physical Drive Table. SEQUENCE OF CpqScsiPhyDrvEntry .1.3.6.1.4.1.232.5.2.4.1 |
cpqScsiPhyDrvEntrySCSI Physical Drive Entry. CpqScsiPhyDrvEntry .1.3.6.1.4.1.232.5.2.4.1.1 |
cpqScsiPhyDrvCntlrIndexSCSI Physical Drive Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.1 |
cpqScsiPhyDrvBusIndexSCSI Physical Drive Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.2 |
cpqScsiPhyDrvIndexSCSI Physical Drive Index.
The physical drive index indicates to which physical drive
instance on a SCSI bus this table entry belongs. The physical
drive index is the SCSI ID being used by that drive.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.3 |
cpqScsiPhyDrvModelSCSI Physical Drive Model.
This is a description of the physical drive's model as returned
by the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.4.1.1.4 |
cpqScsiPhyDrvFWRevSCSI Physical Drive Firmware Revision.
This is the revision level of the physical drive as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.4.1.1.5 |
cpqScsiPhyDrvVendorSCSI Physical Drive Vendor.
This is the physical drive vendor's name as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.4.1.1.6 |
cpqScsiPhyDrvSizeSCSI Physical Drive Size in MB.
This is the size of the physical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as
a megabyte. Drive manufacturers sometimes use the number
1,000,000 as a megabyte when giving drive capacities so this
value may differ from the advertised size of a drive.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.7 |
cpqScsiPhyDrvScsiIDSCSI Physical Drive SCSI ID.
This is the SCSI ID used by the physical drive. SCSI ID's
identify a physical drive on a bus so the controller can
communicate with it.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.8 |
cpqScsiPhyDrvStatusSCSI Physical Drive Status.
The physical drive can be in one of the following states:
other(1)
The drive is in a state other than one of those listed
below.
ok(2)
Indicates that the physical drive is in normal operation mode.
No user action is necessary.
failed(3)
Indicates that the physical drive has failed and can no longer
return data. When convenient, you should bring down the server
and run diagnostics to help identify the problem.
The drive may need to be replaced.
notConfigured(4)
Indicates that the physical drive is not configured. You
need to insure all of the drive's switches are properly set
and that the configuration utility has been run.
badCable(5)
Indicates that a physical drive is not responding.
You should check the cables connected to it. You can bring
down the server and run diagnostics to help identify
the problem.
missingWasOk(6)
Indicates that a physical drive had a status of OK and is no
longer present. The drive has been removed.
missingWasFailed(7)
Indicates that a physical drive had a status of FAILED and is
no longer present. The drive has been removed.
predictiveFailure(8)
Indicates that the physical drive has exceeded a threshold
value for one of it's predictive indicators. When convenient,
you should bring down the server and run diagnostics to
help identify the problem. The drive may need to be replaced.
missingWasPredictiveFailure(9)
Indicates that a physical drive had a status of PREDICTIVE
FAILURE and is no longer present. The drive has been removed.
offline(10)
Indicates that the physical drive is offline and can no longer
return data. No further status is available.
missingWasOffline(11)
Indicates that a physical drive had a status of OFFLINE
and is no longer present. The drive has been removed.
hardError(12)
Indicates that a hard error occurred for this physical drive.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.9 |
cpqScsiPhyDrvServiceHoursSCSI Physical Drive Service Time in hours.
This shows the total number of hours that a physical drive has
been operating under the device driver. You can use the service
time to calculate rates for other physical drive objects.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.10 |
cpqScsiPhyDrvHighReadSectorsSCSI Physical Drive Sectors Read (high).
The phyDrvHighReadSectors and the phyDrvlowReadSectors together
show the total number of sectors read from the physical disk
drive during the service time (phyDrvServiceHours).
The actual number of sectors read equals the phyDrvHighReadSectors
times 2^32 plus the phyDrvLowReadSectors.
This information may be useful for determining rates.
For example, if you want to calculate the average number of
reads per hour of operation, divide this number by the service
time.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.11 |
cpqScsiPhyDrvLowReadSectorsSCSI Physical Drive Sectors Read (low).
The phyDrvHighReadSectors and the phyDrvlowReadSectors together
show the total number of sectors read from the physical disk
drive during the service time (phyDrvServiceHours).
The actual number of sectors read equals the phyDrvHighReadSectors
times 2^32 plus the phyDrvLowReadSectors.
This information may be useful for determining rates.
For example, if you want to calculate the average number of reads
per hour of operation, divide this number by the service time.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.12 |
cpqScsiPhyDrvHighWriteSectorsSCSI Physical Drive Sectors Written (high).
The phyDrvHighWriteSectors and the phyDrvlowWriteSectors together
show the total number of sectors written to the physical disk
drive during the service time (phyDrvServiceHours).
The actual number of sectors read equals the phyDrvHighWriteSectors
times 2^32 plus the phyDrvLowWriteSectors.
This information may be useful for determining rates.
For example, if you want to calculate the average number of
writes per hour of operation, divide this number by the service
time.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.13 |
cpqScsiPhyDrvLowWriteSectorsSCSI Physical Drive Sectors Written (low).
The phyDrvHighWriteSectors and the phyDrvlowWriteSectors together
show the total number of sectors written to the physical disk
drive during the service time (phyDrvServiceHours).
The actual number of sectors read equals the phyDrvHighWriteSectors
times 2^32 plus the phyDrvLowWriteSectors.
This information may be useful for determining rates.
For example, if you want to calculate the average number of
writes per hour of operation, divide this number by the service
time.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.14 |
cpqScsiPhyDrvHardReadErrsSCSI Physical Drive Hard Read Errors.
This is the number of read errors that have occurred on a drive
that could not be recovered by a physical drive's Error Correction
Code (ECC) algorithm, retries or any other recovery mechanisms
during the service time (phyDrvServiceHours).
If you see any hard read errors there may be a problem.
This is often caused by bad media sections on the drive. If the
error count continues to rise you may need to replace the drive.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.15 |
cpqScsiPhyDrvHardWriteErrsSCSI Physical Drive Hard Write Errors.
This is the number of write errors that have occurred on a drive
that could not be recovered by retries or any other recovery
mechanisms during the service time (phyDrvServiceHours).
If you see any hard write errors there may be a problem.
This is often caused by bad media sections on the drive. If the
error count continues to rise you may need to replace the drive.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.16 |
cpqScsiPhyDrvEccCorrReadsSCSI Physical Drive ECC Corrected Read Errors (high).
This is the number of read requests that the drive had to use
an Error Correction Code (ECC) algorithm on to recover data
during the service time (phyDrvServiceHours).
ECC corrected reads will occasionally occur over time. Having a
large number of ECC corrected errors does not necessarily indicate
that the drive is failing. However, you may wish to replace a
drive with an abnormally high amount in comparison to other
similar drives as a precaution.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.17 |
cpqScsiPhyDrvRecvReadErrsSCSI Physical Drive Recovered Read Errors.
This is the number of read requests that the drive had to use
retries or other recovery mechanisms on to recover data during
the service time (phyDrvServiceHours).
Retry corrected reads will occasionally occur over time.
Having a large number of retry corrected errors does not
necessarily indicate that the drive is failing. However, you
may wish to replace a drive with an abnormally high amount in
comparison to other similiar drives as a precaution.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.18 |
cpqScsiPhyDrvRecvWriteErrsSCSI Physical Drive Recovered Write Errors.
This is the number of write requests that the drive had to use
retries or other recovery mechanisms on to recover data during
the service time (phyDrvServiceHours).
Retry corrected writes will occasionally occur over time.
Having a large number of retry corrected errors does not
necessarily indicate that the drive is failing. However, you
may wish to replace a drive with an abnormally high amount in
comparison to other similiar drives as a precaution.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.19 |
cpqScsiPhyDrvSeekErrsSCSI Physical Drive Seek Errors.
This is the number of times a drive head seek failed during the
service time (phyDrvServiceHours).
Seek errors will occasionally occur over time. Having a
large number of seek errors does not necessarily indicate
that the drive is failing. However, you may wish to replace
a drive with an abnormally high amount in comparison to other
similiar drives as a precaution.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.20 |
cpqScsiPhyDrvSpinupTimeSCSI Physical Drive Spin up Time (tenths of seconds).
This is the time it takes for a physical drive to spin up to full
speed.
Disks require time to gain momentum and reach operating speed.
As cars are tested to go from 0 mph to 60 mph in x number of
seconds, drive manufacturers have preset expectations for the
time it takes the drive to spin to full speed. Drives that do
not meet these expectations may have problems.
If the drive is having problems spinning up, this value will
increase over time. Eventually, the drive may fail to spin up
altogether. If you see a large increase in this value over
time, you may want to replace the drive as a precaution.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.21 |
cpqScsiPhyDrvUsedReallocsSCSI Physical Drive Used Reallocation Sectors.
This shows the number of sectors of the reallocation area that
have been used by the physical drive over the life of the drive.
Because of the nature of magnetic disks, certain sectors on a
drive may have media defects. The reallocation area is part of
the disk drive that the drive manufacturer sets aside to
compensate for these defects. The drive writes information
addressed from these unusable sectors to available sectors in
the reallocation area.
If all of the reserved sectors have been used, then there is
no way for the drive to remap bad sectors and the drive will
start failing. Unfortunately, the number of reallocation
sectors originally reserved for this purpose is drive specific
and you must contact the drive vendor for these values.
If the current value starts to approach the maximum reserved you
may wish to replace the drive before it fails.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.22 |
cpqScsiPhyDrvTimeoutsSCSI Physical Drive Time-out Errors.
This is the number of times the drive failed to complete a request
within a specified amount of time during the service time
(phyDrvServiceHours).
Time-outs may occasionally occur when a device fails to process a
request because the SCSI bus was busy. If this value should rise
dramatically, you may have a problem. Check if you have any
non-disk SCSI devices, like tape drives, on the SCSI bus with
the drives. Sometimes a non-disk device can hold onto the SCSI
bus for long periods of time causing time-outs.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.23 |
cpqScsiPhyDrvPostErrsSCSI Physical Drive Power On Self Test (POST) Errors.
This is the number of times that a drive failed its self test
during the service time (phyDrvServiceHours). The drive does
a self test each time power is applied to the system.
If you see any self test errors there may be a problem.
You can run diagnostics to help identify the problem.ro Counter .1.3.6.1.4.1.232.5.2.4.1.1.24 |
cpqScsiPhyDrvPostErrCodeSCSI Physical Drive Last POST Error Code.
This is the result of the last SCSI command which caused a self
test to fail. The value is split into three fields. The first
byte is the SCSI Sense Qualifier. The second byte is the
SCSI Sense Code. The third byte is the SCSI Sense Key. You
will need to refer to a SCSI-2 specification for the valid values
of these fields.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.25 |
cpqScsiPhyDrvConditionSCSI Physical Drive Condition.
This is the overall condition of the physical drive.
The following values are defined:
other(1)
The agent does not recognize the status. You may need
to upgrade your software.
ok(2)
The physical drive is operating normally. No user action
is required.
degraded(3)
The physical drive is degraded. You need to check the status
of all logical drives and physical drives.
failed(4)
The physical drives has failed. When convenient, you
should bring down the server and run diagnostics
to help identify the problem.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.26 |
cpqScsiPhyDrvFuncTest1SCSI Physical Drive Functional Test 1.
This is a percentage value that represents the operating
efficiency of a drive. The functional test issues a series of
SCSI commands and times the results. When the drive has the
test run for the very first time (service time is zero), the
results are saved as the baseline value. Then, whenever the
test is executed the current result is compared to the baseline
result and expressed as a percent.
If the percentage result should drop rapidly there may be a
problem with the drive. You may wish to replace the drive as a
precaution.ro Gauge .1.3.6.1.4.1.232.5.2.4.1.1.27 |
cpqScsiPhyDrvFuncTest2SCSI Physical Drive Functional Test 2.
This is a percentage value that represents the operating
efficiency of a drive. The functional test issues a series of
SCSI commands and times the results. When the drive has the
test run for the very first time (service time is zero), the
results are saved as the baseline value. Then, whenever the
test is executed the current result is compared to the baseline
result and expressed as a percent.
If the percentage result should drop rapidly there may be a
problem with the drive. You may wish to replace the drive as a
precaution.ro Gauge .1.3.6.1.4.1.232.5.2.4.1.1.28 |
cpqScsiPhyDrvStatsPreservedSCSI Physical Drive Statistics Preservation Method.
This value indicates how all of the objects in this table
are saved over a power cycle. If the objects are not saved
then all of their values will be reset whenever the device
driver is unloaded. The following values are defined:
other(1)
The agent does not recognize the status. You may
need to upgrade your software.
inNVRAM(2)
The objects are saved in non-volatile memory in the
computer system.
onDisk(3)
The objects are saved on the physical drives in reserved
sectors.
noCPUSupport(4)
The objects are not saved across power cycles because
the hardware does not support this operation.
noFreeNVRAM(5)
The objects are not saved across power cycles because
all of the available non-volatile memory is in use.
noDrvSupport(6)
The objects are not saved across power cycles because
the physical drive does not contain a unique identifier to
save it under.
noSoftwareSupport(7)
The objects are not saved across power cycles because
either the device driver or computer system firmware do not
provide support.
statsNotSupported(8)
Drive statistics are not supported.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.29 |
cpqScsiPhyDrvSerialNumSCSI Physical Drive Serial Number.
This is the serial number assigned to the physical drive.
This value is based upon the serial number as returned by the
SCSI inquiry command but may have been modified due to space
limitations. This can be used for identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.4.1.1.30 |
cpqScsiPhyDrvLocationSCSI Physical Drive Location.
This is the physical location of where the drive is located. The
following values are defined:
other(1)
The drives are not located in any special product that
identifies the location.
proliant(2)
The drives are located in the ProLiant Storage System.rodeprecated Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.31 |
cpqScsiPhyDrvParentSCSI Physical Drive Parent.
This is the logical drive index to which this physical
drive belongs.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.32 |
cpqScsiPhyDrvSectorSizeSCSI Physical Drive Sector Size in Bytes.
This allows one to convert counters that are reported in sectors
to bytes.ro INTEGER .1.3.6.1.4.1.232.5.2.4.1.1.33 |
cpqScsiPhyDrvHotPlugSCSI Physical Drive Hot Plug Support Status.
The following values are defined:
other(1)
The agent is unable to determine if this drive
supports hot plug replacement.
hotPlug(2)
The drive supports hot plug replacement.
nonhotPlug(3)
The drive does not support hot plug replacement.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.34 |
cpqScsiPhyDrvPlacementSCSI Physical Drive Placement.
The following values are defined:
other(1)
The agent is unable to determine if the drive is internal or
external to the system chassis.
internal(2)
The drive is located in an internal Proliant system chassis.
external(3)
The drive is located in an external Proliant storage system.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.35 |
cpqScsiPhyDrvPreFailMonitoringSCSI Physical Drive Predictive Failure Monitoring.
The following values are defined:
other(1)
The agent is unable to determine if the drive supports
predictive failure monitoring.
notAvailable(2)
This drive does not support predictive failure monitoring.
available(3)
This drive supports predictive failure monitoring.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.36 |
cpqScsiPhyDrvOsNamePhysical Drive OS Name.
The OS name for this SCSI physical drive. This field will be
a null (size 0) string if the agent does not support OS name.ro DisplayString .1.3.6.1.4.1.232.5.2.4.1.1.37 |
cpqScsiPhyDrvRotationalSpeedSCSI Physical Drive Rotational Speed.
The following values are defined:
other(1)
The agent is unable to determine the rotational speed for
this drive.
rpm7200(2)
The rotational speed for this drive is 7200 rpm.
rpm10K(3)
The rotational speed for this drive is 10000 rpm.
rpm15K(4)
The rotational speed for this drive is 15000 rpm.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.38 |
cpqScsiPhyDrvMemberLogDrvThe Physical Drive is a Member of a Logical Drive.
This is an indication of whether the physical drive is
a member of a SCSI logical drive.
This variable can be in one of the following states:
other(1)
The agent is unable to determine if the physical drive is a
member of a logical drive.
member(2)
The physical drive is a member of a logical drive.
spare(2)
The physical drive is a spare drive for a logical drive.
nonMember(4)
The physical drive is not a logical drive member or spare.ro Enumeration .1.3.6.1.4.1.232.5.2.4.1.1.39 |
cpqScsiTarget OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.5 |
cpqScsiTargetTableSCSI Target Table. SEQUENCE OF CpqScsiTargetEntry .1.3.6.1.4.1.232.5.2.5.1 |
cpqScsiTargetEntrySCSI Target Entry. CpqScsiTargetEntry .1.3.6.1.4.1.232.5.2.5.1.1 |
cpqScsiTargetCntlrIndexSCSI Target Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.2.5.1.1.1 |
cpqScsiTargetBusIndexSCSI Target Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter card this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.2.5.1.1.2 |
cpqScsiTargetScsiIdIndexSCSI Target Device Index.
The device index indicates to which device instance on a
SCSI bus this table entry belongs. The device index
is the SCSI ID being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.2.5.1.1.3 |
cpqScsiTargetTypeSCSI Device Type.
This is the type of SCSI device. The following types are defined:
other(1)
The agent does not recognize this type.
You may need to upgrade your software.
disk(2)
This is a direct-access device like a disk drive.
tape(3)
This is a sequential-access device like a tape drive.
printer(4)
This is a printer device.
processor(5)
This is a processor device like the ProLiant Storage System.
worm(6)
This is a write-once, read-many times device.
cd-rom(7)
This is a CD or DVD device.
scanner(8)
This is a scanner device.
optical(9)
This is an optical memory device.
jukeBox(10)
This is a media changer device like a jukebox.
commDev(11)
This is a communications device like a LAN bridge.ro Enumeration .1.3.6.1.4.1.232.5.2.5.1.1.4 |
cpqScsiTargetModelSCSI Device Model.
This is a description of the device's model as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.5.1.1.5 |
cpqScsiTargetFWRevSCSI Device Firmware Revision.
This is the revision level of the device as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.5.1.1.6 |
cpqScsiTargetVendorSCSI Device Vendor.
This is the device vendor's name as returned by the SCSI
inquiry command. This can be used for identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.5.1.1.7 |
cpqScsiTargetParityErrsSCSI Device Bus Parity Errors.
This is the number of parity errors seen on the SCSI bus while
processing commands for this SCSI ID. This value is maintained
since the SCSI Hardware Interface driver was loaded.
Parity errors may occasionally occur. If this value should rise
dramatically, you may have a problem. Some common causes include
radio frequency interference (RFI) on the bus cables, bad or
missing terminating resisters on the drives or having more than
one device with the same SCSI ID. Insure the bus cable is free
of obstructions and that the devices on the bus are properly
configured.ro Counter .1.3.6.1.4.1.232.5.2.5.1.1.8 |
cpqScsiTargetPhaseErrsSCSI Device Bus Phase Errors.
This is the number of times the SCSI bus entered an invalid
operating state while processing commands for the SCSI ID.
This value is maintained since the SCSI Hardware Interface driver
was loaded.
If you see any phase errors you may have a problem.
Phase errors can be caused by a device which is not operating
correctly. If the phase errors continue to increase the device
should be replaced.ro Counter .1.3.6.1.4.1.232.5.2.5.1.1.9 |
cpqScsiTargetSelectTimeoutsSCSI Device Bus Select Time-outs.
This is the number of times the controller attempted to start
communications with a device by selecting it but the device did
not respond.
If you see any select time-outs you may have a problem. The device
may have hung during operations. The SCSI controller will attempt
to reset the device but if this value continues to increment you
may need to power cycle the device.ro Counter .1.3.6.1.4.1.232.5.2.5.1.1.10 |
cpqScsiTargetMsgRejectsSCSI Device Bus Message Rejects.
This is the number of times the device rejected a command because
it did not support the specified operation since the SCSI Hardware
Interface driver was loaded.
A large number for this object does not indicate a problem.
It only shows that the device does not support certain advanced
SCSI commands that the device driver issued.ro Counter .1.3.6.1.4.1.232.5.2.5.1.1.11 |
cpqScsiTargetNegPeriodSCSI Device Negotiated Period.
This is the amount of time that was negotiated between the
controller and the device as a synchronous transfer window.
A synchronous transfer window is how long the device can
transfer data without requiring an acknowledgment from the
controller. In general the larger the negotiated period is,
the lower the device throughput. This value is reported in
quarters of nanoseconds.rodeprecated INTEGER .1.3.6.1.4.1.232.5.2.5.1.1.12 |
cpqScsiTargetLocationSCSI Device Location.
This is the physical location of where the device is located.
The following values are defined:
other(1)
The device is not located in any special product that
identifies the location.
proliant(2)
The device is located in the ProLiant Storage System.ro Enumeration .1.3.6.1.4.1.232.5.2.5.1.1.13 |
cpqScsiTargetNegSpeedSCSI Device Negotiated Speed.
This is the data transfer speed that was negotiated between
the controller and the device. This value is reported in bits
per second.ro INTEGER .1.3.6.1.4.1.232.5.2.5.1.1.14 |
cpqScsiTargetPhysWidthSCSI Device Data Bus Physical Width.
This is the physical width of the device's SCSI data bus.
other(1)
The management agent does not recognize this width. You may
need to upgrade your software.
narrow(2)
The SCSI device supports an 8-bit narrow SCSI data bus.
wide16(3)
The SCSI device supports a 16-bit wide SCSI data bus.ro Enumeration .1.3.6.1.4.1.232.5.2.5.1.1.15 |
cpqScsiTargetNegWidthSCSI Device Data Bus Negotiated Width.
This is the width of the device's SCSI data bus that was
negotiated between the controller and the device. This value
is reported in bits.ro INTEGER .1.3.6.1.4.1.232.5.2.5.1.1.16 |
cpqScsiTargetTypeExtendedSCSI Extended Device Type.
This is additional information about the type of SCSI device.
The following types are defined:
other(1)
This target does not have any extended type information.
pdcd(2)
This is a power-drive CD-ROM.
removableDisk(3)
This is a removable media disk device like a floppy drive.
dltAutoloader(4)
This is a tape library device.
cdJukebox(5)
This is a CD storage system device.
cr3500(6)
This is a CR3500 RAID SCSI controller.
autoloader(7)
This is an autoloader medium changer device.ro Enumeration .1.3.6.1.4.1.232.5.2.5.1.1.17 |
cpqScsiTargetCurrentSpeedSCSI Device Current Data Transfer Speed.
The following values are defined:
other(1)
The agent is unable to determine the current negotiated data
transfer speed for this drive.
asynchronous(2)
The negotiated data transfer speed for this drive is
asynchronous.
fast(3)
The negotiated data transfer speed for this drive is 10 million
transfers per second.
ultra(4)
The negotiated data transfer speed for this drive is 20 million
transfers per second.
ultra2(5)
The negotiated data transfer speed for this drive is 40 million
transfers per second.
ultra3(6)
The negotiated data transfer speed for this drive is 80 million
transfers per second.
scsi1(7)
The negotiated data transfer speed for this drive is 5 million
transfers per second.
ultra4(8)
The negotiated data transfer speed for this drive is 160 million
transfers per second. Ultra4 is now referred to as Ultra320.ro Enumeration .1.3.6.1.4.1.232.5.2.5.1.1.18 |
cpqScsiCd OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.2.6 |
cpqScsiCdDrvTableScsi CD-ROM Drive Table. SEQUENCE OF CpqScsiCdDrvEntry .1.3.6.1.4.1.232.5.2.6.1 |
cpqScsiCdDrvEntryScsi CD-ROM Drive Entry. CpqScsiCdDrvEntry .1.3.6.1.4.1.232.5.2.6.1.1 |
cpqScsiCdDrvCntlrIndexSCSI CD-ROM Drive Controller Index.
The controller index indicates to which SCSI adapter instance
this CD table entry belongs. The controller index is the
physical slot in the computer where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.2.6.1.1.1 |
cpqScsiCdDrvBusIndexSCSI CD-ROM Drive Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.2.6.1.1.2 |
cpqScsiCdDrvScsiIdIndexSCSI CD-ROM Drive Index.
The CD-ROM drive index indicates to which CD-ROM drive
instance on a SCSI bus this table entry belongs. The physical
drive index is the SCSI ID being used by that CD drive.ro INTEGER .1.3.6.1.4.1.232.5.2.6.1.1.3 |
cpqScsiCdDrvLunIndexSCSI CD-ROM Drive Logical Unit Index.
The CD-ROM drive logical unit index indicates to which
physical drive logical unit on a SCSI ID instance on a SCSI
bus this table entry belongs. The CD-ROM drive Lun index
is the logical unit number being used by that CD drive.ro INTEGER .1.3.6.1.4.1.232.5.2.6.1.1.4 |
cpqScsiCdDrvModelSCSI CD Device Model.
This is a description of the device's model as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.6.1.1.5 |
cpqScsiCdDrvVendorSCSI CD Drive Vendor.
This is the CD drive vendor's name as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.6.1.1.6 |
cpqScsiCdDrvFwRevSCSI CD-ROM Firmware Revision.
This is used to differentiate the firmware versions
which have the same CD-ROM drive vendor and model (as specified by
cpqScsiCdVendor and cpqScsiCdModel). This can be retrieved by the
SCSI inquiry command.ro DisplayString .1.3.6.1.4.1.232.5.2.6.1.1.7 |
cpqCdLibraryTableCD Library Table. SEQUENCE OF CpqCdLibraryEntry .1.3.6.1.4.1.232.5.2.6.2 |
cpqCdLibraryEntryCD Library Entry. CpqCdLibraryEntry .1.3.6.1.4.1.232.5.2.6.2.1 |
cpqCdLibraryCntlrIndexSCSI CD Library Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.2.6.2.1.1 |
cpqCdLibraryBusIndexSCSI CD Library Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter card this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.2.6.2.1.2 |
cpqCdLibraryScsiIdIndexSCSI CD Library Device Index.
The device index indicates to which device instance on a
SCSI bus this table entry belongs. The device index
is the SCSI ID being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.2.6.2.1.3 |
cpqCdLibraryLunIndexSCSI CD Library Logical Unit Index.
The logical unit index indicates to which Lun device instance
on a SCSI bus this table entry belongs. The logical unit
index is the Lun being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.2.6.2.1.4 |
cpqCdLibraryConditionCD Library Condition.
This value represents the overall condition of this CD Library.
The library can be in one of the following states:
other(1)
The library is in a state other than one of those listed
below.
ok(2)
Indicates that the library is in normal operation mode.
No user action is necessary.
degraded(3)
Indicates that the library has degraded in some manner.
failed(4)
Indicates that the library has failed and can no longer
return data. When convenient, you should bring down the server
and run diagnostics to help identify the problem.ro Enumeration .1.3.6.1.4.1.232.5.2.6.2.1.5 |
cpqCdLibraryStatusCD Library Status.
This value represents the status of this CD Library.
The library can be in one of the following states:
other(1)
The library is in a state other than one of those listed
below.
ok(2)
Indicates that the CD library fault light is in an 'ok' state.
failed(3)
Indicates that the CD library fault light is in a 'failed' state.
The fault light is activated for hardware errors (Sense Code 04h)
with additional Sense codes: 40h-4fh except the parity error.
The LED will remain on until is powered cycled.
offline(4)
Indicates that the agents can no longer communicate with
the CD library. This could be caused by a cabling problem or the
CD library may be powered off.ro Enumeration .1.3.6.1.4.1.232.5.2.6.2.1.6 |
cpqCdLibraryModelSCSI CD Library Device Model.
This is a description of the device's model as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.6.2.1.7 |
cpqCdLibraryVendorSCSI CD Library Vendor.
This is the CD Library drive vendor's name as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.6.2.1.8 |
cpqCdLibrarySerialNumberCD Library Serial Number.
This is the unit serial number for the library. It
can be used for identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.2.6.2.1.9 |
cpqCdLibraryDriveListCD Library Drive List
This is a data structure containing the list of CD drive ids
that are present in this library. The format is:
BYTE Controller Number
BYTE Bus Number
BYTE SCSI ID
BYTE Logical Unit Number
There will be 1 structure for each drive present in the library.ro OCTET STRING .1.3.6.1.4.1.232.5.2.6.2.1.10 |
cpqCdLibraryFwRevSCSI CD Library Firmware Revision.
This is used to differentiate the firmware versions
which have the same CD library vendor and model (as specified in
cpqCdLibraryVendor and cpqCdLibraryModel). This can be retrieved
by the SCSI inquiry command.ro DisplayString .1.3.6.1.4.1.232.5.2.6.2.1.11 |
cpqCdLibraryFwSubtypeSCSI CD library Firmware Subtype.
This is used to differentiate the firmware versions
which have the same vendor and model. CD library will contain
a value of 1 for this variable when they first ship, and this value
will be incremented if future versions are shipped which
are not firmware compatible with the predecessor. If the
CD library does not support this capability, a value of 0
will be returned.ro INTEGER .1.3.6.1.4.1.232.5.2.6.2.1.12 |
cpqScsiTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.3 |
cpqScsiTrapPktsThe total number of trap packets issued by the SCSI
enterprise since the instrument agent was loaded.rodeprecated Counter .1.3.6.1.4.1.232.5.3.1 |
cpqScsiTrapLogMaxSizeThe maximum number of entries that will currently be kept in
the trap log. If the maximum size has been reached and a new
trap occurs the oldest trap will be removed.rodeprecated INTEGER .1.3.6.1.4.1.232.5.3.2 |
cpqScsiTrapLogTableAn ordered list of trap log entries (conceptually a queue).
The trap log entries will be kept in the order in which they were
generated with the most recent trap at index 1 and the oldest
trap entry at index trapLogMaxSize. If the maximum number size
has been reached and a new trap occurs the oldest trap will be
removed when the new trap is added so the trapMaxLogSize is not
exceeded.deprecated SEQUENCE OF CpqScsiTrapLogEntry .1.3.6.1.4.1.232.5.3.3 |
cpqScsiTrapLogEntryA description of a trap event.deprecated CpqScsiTrapLogEntry .1.3.6.1.4.1.232.5.3.3.1 |
cpqScsiTrapLogIndexThe value of this object uniquely identifies this trapLogEntry
at this time. The most recent trap will have an index of 1 and
the oldest trap will have an index of trapLogMaxSize. Because of
the queue-like nature of the trapLog this particular trap event's
index will change as new traps are issued.rodeprecated INTEGER .1.3.6.1.4.1.232.5.3.3.1.1 |
cpqScsiTrapTypeThe type of the trap event that this entry describes.
This number refers to an entry in a list of traps enumerating the
possible traps the SCSI agent may issue.rodeprecated Enumeration .1.3.6.1.4.1.232.5.3.3.1.2 |
cpqScsiTrapTimeThe time of the trap event that this entry describes.
The time is given in year (first octet), month, day of month,
hour, minute, second (last octet) order. Each octet gives the
value in Binary Coded Decimal (BCD).rodeprecated OCTET STRING .1.3.6.1.4.1.232.5.3.3.1.3 |
cpqTapeComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.4 |
cpqTapePhyDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.4.1 |
cpqTapePhyDrvTableTape Physical Drive Table. SEQUENCE OF CpqTapePhyDrvEntry .1.3.6.1.4.1.232.5.4.1.1 |
cpqTapePhyDrvEntryTape Physical Drive Entry. CpqTapePhyDrvEntry .1.3.6.1.4.1.232.5.4.1.1.1 |
cpqTapePhyDrvCntlrIndexTape Physical Drive Controller Index.
The controller index indicates to which SCSI adapter instance
this tape table entry belongs. The controller index is the
physical slot in the computer where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.1 |
cpqTapePhyDrvBusIndexTape Physical Drive Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.2 |
cpqTapePhyDrvScsiIdIndexTape Physical Drive Index.
The physical drive index indicates to which physical drive
instance on a SCSI bus this table entry belongs. The physical
drive index is the SCSI ID being used by that tape drive.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.3 |
cpqTapePhyDrvLunIndexTape Physical Drive Logical Unit Index.
The physical drive logical unit index indicates to which
physical drive logical unit on a SCSI ID instance on a SCSI
bus this table entry belongs. The physical drive Lun index
is the logical unit number being used by that tape drive.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.4 |
cpqTapePhyDrvTypeTape Device Type.
This is the drives model, and can be used for identification
purposes. The following values are defined:
other(1)
The management agent does not recognize this model.
You may need to upgrade your software.
cpqDat4-16(2)
Compaq 4/8-Gigabyte TurboDAT Drive.
cpqDatAuto(3)
Compaq TurboDAT Autoloader.
cpqDat2-8(4)
Compaq 2/8-Gigabyte TurboDAT Drive.
cpqDlt10-20(5)
Compaq 10/20-GB DLT Drive.
cpqDlt20-40(6)
Compaq 20/40-GB DLT Drive.
cpqDlt15-30(7)
Compaq 15/30-GB DLT Drive.
cpqDlt35-70(8)
Compaq 35/70-GB DLT Drive.
cpqDat4-8(9)
Compaq 4/8-GB DAT Drive.
cpqSlr4-8(10)
Compaq 4/8-GB SLR Drive.
cpqDat12-24(11)
Compaq 12/24-GB DAT Drive.
cpqDatAuto12-24(12)
Compaq 12/24-GB DAT Autoloader.
cpqMlr16-32(13)
Compaq 16/32-GB MLR Drive.
cpqAit35(14)
Compaq AIT 35GB Drive.
cpqAit50(15)
Compaq AIT 50GB Drive.
cpqDat20-40(16)
Compaq 20/40GB DAT Drive.
cpqDlt40-80(17)
Compaq 40/80GB DLT Drive.
cpqDatAuto20-40(18)
Compaq 20/40GB DAT Autoloader.
cpqSuperDlt1(19)
Compaq 100GB Super DLT Drive.
cpqAit35Lvd(20)
Compaq AIT 35 LVD Drive.
cpqCompaq(21)
Supported Tape Drive.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.5 |
cpqTapePhyDrvConditionTape Physical Drive Status.
The physical drive can be in one of the following states:
other(1)
The drive is in a state other than one of those listed
below.
ok(2)
Indicates that the physical drive is in normal operation mode.
No user action is necessary.
degraded(3)
Indicates that the physical drive has degraded in some manner.
failed(4)
Indicates that the physical drive has failed and can no longer
return data. When convenient, you should bring down the server
and run diagnostics to help identify the problem.
The drive may need to be replaced.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.6 |
cpqTapePhyDrvMagSizeTape Physical Drive Magazine Size.
The number of tape slots available in the magazine cartridge
that is currently loaded into the tape drive.
For non-autoloader devices, this value will be 1.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.7 |
cpqTapePhyDrvSerialNumberTape Physical Drive Serial Number.
This is the unit serial number for the tape drive. It
can be used for identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.1.1.1.8 |
cpqTapePhyDrvCleanReqTape Physical Drive Cleaning Required Status.
This is an indication of whether the tape drive heads
require a cleaning session to occur. If this variable
indicates a need to clean the tape heads, then a cleaning
tape will need to be inserted and run through a cleaning
cycle.
This variable can be in one of the following states:
other(1)
The tape drive does not support monitoring of the cleaning
required status.
true(2)
The tape drive requires a cleaning tape session in order
to clean the heads.
false(3)
The tape drive does not require any cleaning tape session.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.9 |
cpqTapePhyDrvCleanTapeReplTape Physical Drive Cleaning Tape Replacement Status.
This variable is only applicable to autoloader tape drives.
This variable indicates whether the cleaning tape which is
inserted in an autoloader needs to be replaced because its
cleaning capability is exhausted (it is at end of tape).
This variable can be in one of the following states:
other(1)
The tape drive does not support monitoring of the cleaning
tape replacement status.
true(2)
The autoloader tape drive requires a new cleaning tape to
be inserted.
false(3)
The tape drive does not require a new cleaning tape.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.10 |
cpqTapePhyDrvFwSubtypeTape Physical Drive Firmware Subtype.
This is used to differentiate the firmware versions
which have the same tape drive type (as specified by
cpqTapePhyDrvType). Tape drives will contain a value
of 1 for this variable when they first ship, and this value
will be incremented if future versions are shipped which
are not firmware compatible with the predecessor. If the
tape drive does not support this capability, a value of 0
will be returned.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.11 |
cpqTapePhyDrvNameTape Physical Drive Name.
This is a combination of the vendor ID and the product ID as
returned by the SCSI inquiry command. This can be used for
identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.1.1.1.12 |
cpqTapePhyDrvCleanTapeCountTape Physical Drive Cleaning Tape Count.
This variable is only applicable to autoloader tape drives.
This variable is a count from a tape drive of the number of
cleanings done by the tape cleaner last in the drive.ro INTEGER .1.3.6.1.4.1.232.5.4.1.1.1.13 |
cpqTapePhyDrvFwRevTape Physical Drive Firmware Revision.
This is the revision level of the physical drive as returned by
the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.1.1.1.14 |
cpqTapePhyDrvStatusTape Physical Drive Status.
The tape physical drive can be in one of the following states:
other(1)
The tape drive is in a state other than one of those listed
below.
ok(2)
Indicates that the tape physical drive is in normal operation
mode. No user action is necessary.
failed(4)
Indicates that the tape physical drive has failed and can no
longer return data. The drive may need to be replaced.
offline(5)
Indicates that the tape physical drive is offline and can no
longer return data. No further status is available.
missingWasOk(6)
Indicates that a tape physical drive had a status of OK and
is no longer present. The drive has been removed.
missingWasFailed(7)
Indicates that a tape physical drive had a status of FAILED
and is no longer present. The drive has been removed.
missingWasOffline(8)
Indicates that a tape physical drive had a status of OFFLINE
and is no longer present. The drive has been removed.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.15 |
cpqTapePhyDrvHotPlugTape Physical Drive Hot Plug Support Status.
The following values are defined:
other(1)
The agent is unable to determine if this drive
supports hot plug replacement.
hotPlug(2)
The drive supports hot plug replacement.
nonhotPlug(3)
The drive does not support hot plug replacement.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.16 |
cpqTapePhyDrvPlacementTape Physical Drive Placement.
The following values are defined:
other(1)
The agent is unable to determine if the tape drive is
internal or external to the system chassis.
internal(2)
The tape drive is located in an internal Proliant system
chassis.
external(3)
The tape drive is located in an external Proliant storage
system.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.17 |
cpqTapePhyDrvLibraryDriveTape Physical Drive Library Drive.
This variable indicates whether or not the tape drive is part
of a tape library. It can be in one of the following states:
other(1)
Indicates that the storage agents cannot determine if the
tape drive is part of a tape library.
true(2)
The tape drive is part of a tape library.
false(3)
The tape drive is not part of a tape library.ro Enumeration .1.3.6.1.4.1.232.5.4.1.1.1.18 |
cpqTapePhyDrvLoaderNameTape Autoloader Name.
This is a combination of the vendor ID and the product ID as
returned by the SCSI inquiry command. This can be used for
identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.1.1.1.19 |
cpqTapePhyDrvLoaderFwRevTape Autoloader Firmware Revision.
This is the firmware revision level of the autoloader as returned
by the SCSI inquiry command. This can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.1.1.1.20 |
cpqTapePhyDrvLoaderSerialNumTape Autoloader Serial Number.
This is the autoloader serial number. It can be used for
identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.1.1.1.21 |
cpqTapeCounters OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.4.2 |
cpqTapeCountersTableTape Counters Table. SEQUENCE OF CpqTapeCountersEntry .1.3.6.1.4.1.232.5.4.2.1 |
cpqTapeCountersEntryTape Counters Entry. CpqTapeCountersEntry .1.3.6.1.4.1.232.5.4.2.1.1 |
cpqTapeCountersCntlrIndexSCSI Counters Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.4.2.1.1.1 |
cpqTapeCountersBusIndexSCSI Counters Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter card this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.4.2.1.1.2 |
cpqTapeCountersScsiIdIndexSCSI Counters Device Index.
The device index indicates to which device instance on a
SCSI bus this table entry belongs. The device index
is the SCSI ID being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.4.2.1.1.3 |
cpqTapeCountersLunIndexSCSI Counters Logical Unit Index.
The logical unit index indicates to which Lun device instance
on a SCSI bus this table entry belongs. The logical unit
index is the Lun being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.4.2.1.1.4 |
cpqTapeCountersReWritesTape Device Re-write count.
This is the number of times blocks had to be re-written to the
device. This value is maintained since the Tape Hardware Interface
driver was loaded.
Re-write errors may occasionally occur. If this value should rise
dramatically, you may need to clean the device. If you continue
to have re-writes, you may have a problem. Some common causes
include radio frequency interference (RFI) on the bus cables,
bad or missing terminating resisters on the drives or having more
than one device with the same SCSI ID. Insure the bus cable is
free of obstructions and that the devices on the bus are properly
configured.ro Counter .1.3.6.1.4.1.232.5.4.2.1.1.5 |
cpqTapeCountersReReadsTape Device Re-read count.
This is the number of times blocks had to be re-read from the
device. This value is maintained since the Tape Hardware Interface
driver was loaded.
Re-read errors may occasionally occur. If this value should rise
dramatically, you may need to clean the device. If you continue
to have re-reads, you may have a problem. Some common causes
include radio frequency interference (RFI) on the bus cables,
bad or missing terminating resisters on the drives or having more
than one device with the same SCSI ID. Insure the bus cable is
free of obstructions and that the devices on the bus are properly
configured.ro Counter .1.3.6.1.4.1.232.5.4.2.1.1.6 |
cpqTapeCountersTotalErrorsTape Device Total Errors.
This is the total number of read/write errors encountered.
This value is maintained since the Tape Hardware Interface
driver was loaded.
Errors may occasionally occur. If this value should rise
dramatically, you may need to clean the device. If you continue
to have errors, you may have a problem. Some common causes include
radio frequency interference (RFI) on the bus cables, bad or
missing terminating resisters on the drives or having more than
one device with the same SCSI ID. Insure the bus cable is free
of obstructions and that the devices on the bus are properly
configured.ro Counter .1.3.6.1.4.1.232.5.4.2.1.1.7 |
cpqTapeCountersTotalUncorrectableTape Device Total Uncorrectable Errors.
This is the total number of read and write errors which could not
be corrected. This value is maintained since the Tape Hardware
Interface driver was loaded.
Errors may occasionally occur. If this value should rise
dramatically, you may need to clean the device. If you continue
to have errors, you may have a problem. Some common causes include
radio frequency interference (RFI) on the bus cables, bad or
missing terminating resisters on the drives or having more than
one device with the same SCSI ID. Insure the bus cable is free
of obstructions and that the devices on the bus are properly
configured.ro Counter .1.3.6.1.4.1.232.5.4.2.1.1.8 |
cpqTapeCountersTotalBytesTape Device Total Bytes.
This is the number total number of bytes read/written to the tape
currently installed in the device. This value is reset whenever
a new tape is inserted into the device.ro Counter .1.3.6.1.4.1.232.5.4.2.1.1.9 |
cpqTapeLibrary OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.4.3 |
cpqTapeLibraryTableTape Library Table. SEQUENCE OF CpqTapeLibraryEntry .1.3.6.1.4.1.232.5.4.3.1 |
cpqTapeLibraryEntryTape Library Entry. CpqTapeLibraryEntry .1.3.6.1.4.1.232.5.4.3.1.1 |
cpqTapeLibraryCntlrIndexSCSI Library Controller Index.
The controller index indicates to which SCSI adapter instance
this table entry belongs. The controller index is the physical
slot in the computer system where the adapter is located.ro INTEGER .1.3.6.1.4.1.232.5.4.3.1.1.1 |
cpqTapeLibraryBusIndexSCSI Library Bus Index.
The bus index indicates to which SCSI bus instance on an
adapter card this table entry belongs. The instances start
at one and increment for each SCSI bus on a card.ro INTEGER .1.3.6.1.4.1.232.5.4.3.1.1.2 |
cpqTapeLibraryScsiIdIndexSCSI Library Device Index.
The device index indicates to which device instance on a
SCSI bus this table entry belongs. The device index
is the SCSI ID being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.4.3.1.1.3 |
cpqTapeLibraryLunIndexSCSI Library Logical Unit Index.
The logical unit index indicates to which Lun device instance
on a SCSI bus this table entry belongs. The logical unit
index is the Lun being used by that device.ro INTEGER .1.3.6.1.4.1.232.5.4.3.1.1.4 |
cpqTapeLibraryConditionTape Library Status.
The library can be in one of the following states:
other(1)
The library is in a state other than one of those listed
below.
ok(2)
Indicates that the library is in normal operation mode.
No user action is necessary.
degraded(3)
Indicates that the library has degraded in some manner.
failed(4)
Indicates that the library has failed and can no longer
return data. When convenient, you should bring down the server
and run diagnostics to help identify the problem.
The library may need to be replaced.ro Enumeration .1.3.6.1.4.1.232.5.4.3.1.1.5 |
cpqTapeLibraryStatusError code returned by the last library error.ro INTEGER .1.3.6.1.4.1.232.5.4.3.1.1.6 |
cpqTapeLibraryDoorStatusStatus of the library door.
The door can be in one of the following states:
other(1)
The door is in a state other than one of those listed
below.
closed(2)
The door is closed.
open(3)
The door is open.
notSupported(4)
The door status is not supported by the device.ro Enumeration .1.3.6.1.4.1.232.5.4.3.1.1.7 |
cpqTapeLibraryStatHoursThe number of hours of operation for the library.ro Counter .1.3.6.1.4.1.232.5.4.3.1.1.8 |
cpqTapeLibraryStatMovesThe number of tape moves for the library loader arm.ro Counter .1.3.6.1.4.1.232.5.4.3.1.1.9 |
cpqTapeLibraryNameTape Library Name.ro DisplayString .1.3.6.1.4.1.232.5.4.3.1.1.10 |
cpqTapeLibrarySerialNumberTape Library Serial Number.
This is the unit serial number for the library. It
can be used for identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.3.1.1.11 |
cpqTapeLibraryDriveListTape Library Drive List
This is a data structure containing the list of tape drive ids
that are present in this library. The format is:
BYTE Controller Number
BYTE Bus Number
BYTE SCSI ID
BYTE Logical Unit Number
There will be 1 structure for each drive present in the library.rodeprecated OCTET STRING .1.3.6.1.4.1.232.5.4.3.1.1.12 |
cpqTapeLibraryStateTape Library Status.
The library can be in one of the following states:
other(1)
The library is in a state other than one of those listed
below.
ok(2)
Indicates that the library is in normal operation mode.
No user action is necessary.
degraded(3)
Indicates that the library has degraded in some manner.
failed(4)
Indicates that the library has failed and can no longer
return data. When convenient, you should bring down the server
and run diagnostics to help identify the problem.
The library may need to be replaced.
offline(5)
Indicates that the agents can no longer communicate with
the library. This could be caused by a cabling problem or the
library may be powered off.ro Enumeration .1.3.6.1.4.1.232.5.4.3.1.1.13 |
cpqTapeLibraryTemperatureTape Library Temperature Status.
The library temperature can be in one of the following states:
other(1)
The library temperature status is unknown.
notSupported(2)
Indicates that the library cannot detect or report temperature.
ok(3)
Indicates that the temperature of the library is within normal
operating limits.
safeTempExceeded(4)
Indicates that the temperature of the library has exceeded the
safe operational temperature. The library will continue to
operate under this warning.
maxTempExceeded(5)
Indicates that the temperature of the library has exceeded
normal operating limits to the extent that the library may
no longer function.ro Enumeration .1.3.6.1.4.1.232.5.4.3.1.1.14 |
cpqTapeLibraryRedundancyTape Library Redundancy Status.
Redundancy status denotes the presence of internal redundant
components such as fans, power supplies, etc. The library
redundancy can be in one of the following states:
other(1)
The library redundancy status is unknown.
notSupported(2)
Indicates that the library cannot detect or report redundancy
status.
capable(3)
Indicates that the library is capable of detecting and reporting
redundant components but there are not enough redundant units
installed to make redundancy active.
notCapable(4)
Indicates that the library is capable of detecting and reporting
redundant components but there are no components that support
redundancy.
active(5)
Indicates that the library is capable of detecting and reporting
redundant components, there are enough redundant units installed,
and redundancy is active.ro Enumeration .1.3.6.1.4.1.232.5.4.3.1.1.15 |
cpqTapeLibraryHotSwapTape Library Hot Swap Status.
Hot swap status denotes the presence of hot swappable internal
components such as drives, fans, power supplies, etc. The library
hot swap status can be in one of the following states:
other(1)
The library hot swap status is unknown.
notSupported(2)
Indicates that the library cannot detect or report hot swap
status.
capable(3)
Indicates that the library is capable of detecting and reporting
hot swappable internal components and has at least one hot
swappable component.
notCapable(4)
Indicates that the library is capable of detecting and reporting
hot swappable internal components but there are no hot swappable
components installed.ro Enumeration .1.3.6.1.4.1.232.5.4.3.1.1.16 |
cpqTapeLibraryFwRevTape Library Firmware Revision.
This is the revision level of the tape library firmware as
returned by the SCSI inquiry command. This can be used for
identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.4.3.1.1.17 |
cpqTapeLibraryTapeListTape Library Drive List
This is a data structure containing the list of tape drive ids
that are present in this library. The format is:
ULONG Controller Number
BYTE Bus Number
BYTE SCSI ID
BYTE Logical Unit Number
There will be 1 structure for each drive present in the library.ro OCTET STRING .1.3.6.1.4.1.232.5.4.3.1.1.18 |
cpqSasComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.5 |
cpqSasHba OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.5.1 |
cpqSasHbaTableSAS Host Bus Adapter Table. SEQUENCE OF CpqSasHbaEntry .1.3.6.1.4.1.232.5.5.1.1 |
cpqSasHbaEntrySAS Controller Table Entry. CpqSasHbaEntry .1.3.6.1.4.1.232.5.5.1.1.1 |
cpqSasHbaIndexSAS Host Bus Adapter Index.
The HBA index indicates to which SAS adapter instance this table
entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.1.1.1.1 |
cpqSasHbaHwLocationSAS Host Bus Adapter Hardware Location.
A text description of the hardware location of the HBA.
A NULL string indicates that the hardware location could not
be determined or is irrelevant.ro DisplayString .1.3.6.1.4.1.232.5.5.1.1.1.2 |
cpqSasHbaModelSAS Host Bus Adapter Model.
This is the HBA model and can be used for identification
purposes. The following values are defined:
other(1) The management agent does not recognize this model.
You may need to upgrade your software.
generic(2) SAS HBA
sas8int(3) HP 8 Internal Port SAS HBA with RAID
sas4int(4) HP 4 Internal Port SAS HBA with RAID
sasSc44Ge(5) HP SC44Ge Host Bus Adapter
sasSc40Ge(6) HP SC40Ge HBA
sasSc08Ge(7) HP SC08Ge Host Bus Adapterro Enumeration .1.3.6.1.4.1.232.5.5.1.1.1.3 |
cpqSasHbaStatusSAS Host Bus Adapter Status.
This is the current status of the HBA. The following values are
currently defined:
other(1)
The management agent does not recognize the status as one of
those listed below.
ok(2)
The HBA is operating normally.
failed(3)
The HBA has failed and is no longer operating.ro Enumeration .1.3.6.1.4.1.232.5.5.1.1.1.4 |
cpqSasHbaConditionSAS Host Bus Adapter Condition.
This is the condition of the HBA hardware.ro Enumeration .1.3.6.1.4.1.232.5.5.1.1.1.5 |
cpqSasHbaOverallConditionSAS Host Bus Adapter Overall Condition.
This is the overall condition of the HBA and all of the logical
drives and physical drives controlled by it.ro Enumeration .1.3.6.1.4.1.232.5.5.1.1.1.6 |
cpqSasHbaSerialNumberSAS Host Bus Adapter Serial Number.
This is the serial number assigned to the HBA. This can be used
for identification purposes. This field will be a null (size 0)
string if the management agent cannot provide the serial number.ro DisplayString .1.3.6.1.4.1.232.5.5.1.1.1.7 |
cpqSasHbaFwVersionSAS Host Bus Adapter Firmware Version.
This is the version of the firmware on the SAS HBA.
This field will be a null (size 0) string if the management
agent cannot provide the BIOS version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.5.5.1.1.1.8 |
cpqSasHbaBiosVersionSAS Host Bus Adapter BIOS Version.
This is the version of the BIOS on the SAS HBA.
This field will be a null (size 0) string if the management
agent cannot provide the BIOS version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.5.5.1.1.1.9 |
cpqSasPhyDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.5.2 |
cpqSasPhyDrvTableSAS Physical Drive Table. SEQUENCE OF CpqSasPhyDrvEntry .1.3.6.1.4.1.232.5.5.2.1 |
cpqSasPhyDrvEntrySAS Physical Drive Entry. CpqSasPhyDrvEntry .1.3.6.1.4.1.232.5.5.2.1.1 |
cpqSasPhyDrvHbaIndexSAS Physical Drive HBA Index.
The HBA index indicates to which SAS adapter instance this table
entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.2.1.1.1 |
cpqSasPhyDrvIndexSAS Physical Drive Index.
The physical drive index indicates to which physical drive
instance this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.2.1.1.2 |
cpqSasPhyDrvLocationStringSAS Physical Drive Location String.
This string describes the location of the drive in relation to
the HBA. If the location string cannot be determined, the agent
will return a NULL string.ro DisplayString .1.3.6.1.4.1.232.5.5.2.1.1.3 |
cpqSasPhyDrvModelSAS Physical Drive Model.
This is a physical drive's model name. It can be used for
identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.5.2.1.1.4 |
cpqSasPhyDrvStatusSAS Physical Drive Status.
The physical drive can be in one of the following states:
other(1)
The drive is in a state other than one of those listed
below.
ok(2)
Indicates that the physical drive is in normal operation mode.
No user action is necessary.
predictiveFailure(3)
Indicates that the physical drive has exceeded a threshold
value for one of it's predictive indicators.
offline(4)
Indicates that the physical drive is offline and can no longer
return data. No further status is available.
failed(5)
Indicates that the physical drive has failed and can no longer
return data.
missingWasOk(6)
Indicates that a physical drive had a status of ok(2) and is
no longer present. The drive has been removed.
missingWasPredictiveFailure(7)
Indicates that a physical drive had a status of
predictiveFailure(3) and is no longer present. The drive has
been removed.
missingWasOffline(8)
Indicates that a physical drive had a status of offline(4) and
is no longer present. The drive has been removed.
missingWasFailed(9)
Indicates that a physical drive had a status of failed(5) and
is no longer present. The drive has been removed.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.5 |
cpqSasPhyDrvConditionSAS Physical Drive Condition.
This is the overall condition of the physical drive.
The following values are defined:
other(1)
The agent does not recognize the status. You may need
to upgrade your software.
ok(2)
The physical drive is operating normally. No user action
is required.
degraded(3)
The physical drive is degraded.
failed(4)
The physical drives has failed.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.6 |
cpqSasPhyDrvFWRevSAS Physical Drive Firmware Revision.
This is the firmware revision of the physical drive.ro DisplayString .1.3.6.1.4.1.232.5.5.2.1.1.7 |
cpqSasPhyDrvSizeSAS Physical Drive Size in MB.
This is the size of the physical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as
a megabyte. Drive manufacturers sometimes use the number
1,000,000 as a megabyte when giving drive capacities so this
value may differ from the advertised size of a drive.ro INTEGER .1.3.6.1.4.1.232.5.5.2.1.1.8 |
cpqSasPhyDrvUsedReallocsSAS Physical Drive Used Reallocation Sectors.
This shows the number of sectors of the reallocation area that
have been used by the physical drive over the life of the drive.ro Counter .1.3.6.1.4.1.232.5.5.2.1.1.9 |
cpqSasPhyDrvSerialNumberSAS Physical Drive Serial Number.
This is the serial number assigned to the physical drive.ro DisplayString .1.3.6.1.4.1.232.5.5.2.1.1.10 |
cpqSasPhyDrvMemberLogDrvThe Physical Drive is a Member of a Logical Drive.
This is an indication of whether the physical drive is
a member of a logical drive.
This variable can be in one of the following states:
other(1)
The agent is unable to determine if the physical drive is a
member of a logical drive.
member(2)
The physical drive is a member of a logical drive.
spare(2)
The physical drive is a spare drive for a logical drive.
nonMember(4)
The physical drive is not a logical drive member or spare.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.11 |
cpqSasPhyDrvRotationalSpeedSAS Physical Drive Rotational Speed.
The following values are defined:
other(1)
The agent is unable to determine the rotational speed for
this drive.
rpm7200(2)
The rotational speed for this drive is 7200 rpm.
rpm10K(3)
The rotational speed for this drive is 10000 rpm.
rpm15K(4)
The rotational speed for this drive is 15000 rpm.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.12 |
cpqSasPhyDrvOsNameSAS Physical Drive OS Name.
The OS name for this SAS physical drive. This field will be
a null (size 0) string if the agent does not support OS name.ro DisplayString .1.3.6.1.4.1.232.5.5.2.1.1.13 |
cpqSasPhyDrvPlacementSAS Physical Drive Placement.
The following values are defined:
other(1)
The agent is unable to determine if the drive is internal or
external.
internal(2)
The drive is located in an internal system chassis.
external(3)
The drive is located in an external storage system.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.14 |
cpqSasPhyDrvHotPlugSAS Physical Drive Hot Plug Support Status.
The following values are defined:
other(1)
The agent is unable to determine if this drive
supports hot plug replacement.
hotPlug(2)
The drive supports hot plug replacement.
nonhotPlug(3)
The drive does not support hot plug replacement.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.15 |
cpqSasPhyDrvTypeSAS Physical Drive Type.
The following values are defined:
other(1)
The agent is unable to determine the type for this drive.
sas(2)
The drive type is Serial Attached SCSI.
sata(3)
The drive type is Serial ATA.ro Enumeration .1.3.6.1.4.1.232.5.5.2.1.1.16 |
cpqSasPhyDrvSasAddressSAS Physical Drive SAS Address.
The SAS address this SAS physical drive. A null (size 0) string
will be returned if the value cannot be determined.ro DisplayString .1.3.6.1.4.1.232.5.5.2.1.1.17 |
cpqSasLogDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.5.3 |
cpqSasLogDrvTableSAS Logical Drive Table. SEQUENCE OF CpqSasLogDrvEntry .1.3.6.1.4.1.232.5.5.3.1 |
cpqSasLogDrvEntrySAS Logical Drive Entry. CpqSasLogDrvEntry .1.3.6.1.4.1.232.5.5.3.1.1 |
cpqSasLogDrvHbaIndexSAS Logical Drive HBA Index.
The controller index indicates to which SAS adapter instance
this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.3.1.1.1 |
cpqSasLogDrvIndexSAS Logical Drive Index.
The logical drive index indicates to which logical drive instance
this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.3.1.1.2 |
cpqSasLogDrvRaidLevelSAS Logical Drive RAID Level.
The following RAID levels are defined:
other(1)
The agent cannot determine the RAID level of this logical drive.
raid0(2)
The logical drive is configured with RAID level 0.
raid1(3)
The logical drive is configured with RAID level 1.ro Enumeration .1.3.6.1.4.1.232.5.5.3.1.1.3 |
cpqSasLogDrvStatusSAS Logical Drive Status.
The logical drive can be in one of the following states:
other(1)
The management agent does not recognize the status.
You may need to upgrade your software.
ok(2)
Indicates that the logical drive is in normal operation mode.
No user action is required.
degraded(3)
Indicates that the logical drive is in a degraded state.
rebuilding(4)
Indicates that the logical drive is currently resynchronizing
the data accross the physical drives in the logical drive.
failed(5)
Indicates that more physical drives have failed than the
fault tolerance mode of the logical drive can handle without
data loss.
offline(6)
Indicates that the logical drive is offline from the operating
system. User action may be required to bring the logical
drive online.ro Enumeration .1.3.6.1.4.1.232.5.5.3.1.1.4 |
cpqSasLogDrvConditionSAS Logical Drive Condition.
This is the condition of the logical drive.ro Enumeration .1.3.6.1.4.1.232.5.5.3.1.1.5 |
cpqSasLogDrvRebuildingDiskSAS Logical Drive Rebuilding Disk.
This is the disk that is in the process of rebuilding. If no
drive is currently rebuilding, a value of -1 will be returned.ro INTEGER .1.3.6.1.4.1.232.5.5.3.1.1.6 |
cpqSasLogDrvCapacitySAS Logical Drive Size.
This is the capacity of the logical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as
a megabyte. Drive manufacturers sometimes use the
number 1,000,000 as a megabyte when giving drive capacities
so this value may differ from the advertised size of a drive.ro INTEGER .1.3.6.1.4.1.232.5.5.3.1.1.7 |
cpqSasLogDrvStripeSizeSAS Logical Drive Stripe Size.
This is the size of a logical drive stripe in kilobytes.ro INTEGER .1.3.6.1.4.1.232.5.5.3.1.1.8 |
cpqSasLogDrvPhyDrvIdsSAS Logical Drive Physical Drive IDs.
This lists the physical drive ID's associated with this logical
drive. Each 4 octets of the string can be used as an index
(cpqSasPhyDrvIndex) into the SAS physical drive table. These 4
octets are repeated for each drive in the list. For n disk
drives in the list, the string is 4 * n octets long.ro OCTET STRING .1.3.6.1.4.1.232.5.5.3.1.1.9 |
cpqSasLogDrvSpareIdsSAS Logical Drive Spare Drive IDs.
This lists the spare drive ID's associated with this logical
drive. Each 4 octets of the string can be used as an index
(cpqSasPhyDrvIndex) into the SAS physical drive table. These 4
octets are repeated for each drive in the list. For n disk
drives in the list, the string is 4 * n octets long.ro OCTET STRING .1.3.6.1.4.1.232.5.5.3.1.1.10 |
cpqSasLogDrvOsNameSAS Logical Drive OS Name.
This is the OS name for the logical drive. This field will be
a null (size 0) string if the agent does not support OS name.ro DisplayString .1.3.6.1.4.1.232.5.5.3.1.1.11 |
cpqSasLogDrvRebuildingPercentLogical Drive Percent Rebuild.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value is the percent
complete of the rebuild. When the value reaches 100, the
rebuilding process is complete. The array continues to
operate in interim recovery mode while the disk is rebuilding.
This value is only valid if the Logical Drive Status is
rebuilding(4).
If the value cannot be determined or a rebuild is not active,
the value is set to 4,294,967,295.ro Gauge .1.3.6.1.4.1.232.5.5.3.1.1.12 |
cpqSasTapeDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.5.5.4 |
cpqSasTapeDrvTableSAS Physical Drive Table. SEQUENCE OF CpqSasTapeDrvEntry .1.3.6.1.4.1.232.5.5.4.1 |
cpqSasTapeDrvEntrySAS Physical Drive Entry. CpqSasTapeDrvEntry .1.3.6.1.4.1.232.5.5.4.1.1 |
cpqSasTapeDrvHbaIndexSAS Tape Drive HBA Index.
The HBA index indicates to which SAS adapter instance this table
entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.4.1.1.1 |
cpqSasTapeDrvIndexSAS Tape Drive Index.
The tape drive index indicates to which tape drive instance
this table entry belongs.ro INTEGER .1.3.6.1.4.1.232.5.5.4.1.1.2 |
cpqSasTapeDrvLocationStringSAS Tape Drive Location String.
This string describes the location of the drive in relation to
the HBA. If the location string cannot be determined, the agent
will return a NULL string.ro DisplayString .1.3.6.1.4.1.232.5.5.4.1.1.3 |
cpqSasTapeDrvNameSAS Tape Drive Name.
This is a combination of the vendor ID and the product ID as
returned by the SCSI inquiry command. This can be used for
identification purposes.ro DisplayString .1.3.6.1.4.1.232.5.5.4.1.1.4 |
cpqSasTapeDrvStatusSAS Physical Drive Status.
The physical drive can be in one of the following states:
other(1)
The tape drive is in a state other than one of those listed
below.
ok(2)
Indicates that the tape drive is in normal operation mode.
No user action is necessary.
offline(3)
Indicates that the tape drive is offline and can no longer
return data. No further status is available.ro Enumeration .1.3.6.1.4.1.232.5.5.4.1.1.5 |
cpqSasTapeDrvConditionSAS Tape Drive Condition.
This is the overall condition of the tape drive.
The following values are defined:
other(1)
The agent does not recognize the status. You may need
to upgrade your software.
ok(2)
The tape drive is operating normally. No user action is
required.
degraded(3)
The tape drive is degraded.
failed(4)
The tape drives has failed.ro Enumeration .1.3.6.1.4.1.232.5.5.4.1.1.6 |
cpqSasTapeDrvFWRevSAS Tape Drive Firmware Revision.
This is the firmware revision of the tape drive.ro DisplayString .1.3.6.1.4.1.232.5.5.4.1.1.7 |
cpqSasTapeDrvSerialNumberSAS Tape Drive Serial Number.
This is the serial number assigned to the tape drive.ro DisplayString .1.3.6.1.4.1.232.5.5.4.1.1.8 |
cpqSasTapeDrvSasAddressSAS Tape Drive SAS Address.
The SAS address of this SAS tape drive. A null (size 0) string
will be returned if the value cannot be determined.ro DisplayString .1.3.6.1.4.1.232.5.5.4.1.1.9 |
cpqSbScsiBus OBJECT IDENTIFIER .1.3.6.1.4.1.232.7 |
cpqSbScsiMibRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.7.1 |
cpqSbMibRevMajorThe Major Revision level. A change in the major revision level
represents a major change in the architecture of the MIB. A
change in the major revision level may indicate a significant
change in the information supported and/or the meaning of the
supported information, correct interpretation of data may require
a MIB document with the same major revision level.rodeprecated INTEGER .1.3.6.1.4.1.232.7.1.1 |
cpqSbMibRevMinorThe Minor Revision level. A change in the minor revision level
may represent some minor additional support; no changes to any
pre-existing information has occurred.rodeprecated INTEGER .1.3.6.1.4.1.232.7.1.2 |
cpqSbDevice OBJECT IDENTIFIER .1.3.6.1.4.1.232.7.2 |
cpqSbDeviceTableSCSI Drive Bus Tabledeprecated SEQUENCE OF CpqSbDeviceEntry .1.3.6.1.4.1.232.7.2.2 |
cpqSbDeviceEntrySCSI Drive Bus Entrydeprecated CpqSbDeviceEntry .1.3.6.1.4.1.232.7.2.2.1 |
cpqSbDevCntlrIndexSCSI Device Bus Controller Index
The controller index indicates which SCSI adapter card instance
this table entry belongs to. The controller index is the physical
slot in the computer system where the adapter card is located.rodeprecated INTEGER .1.3.6.1.4.1.232.7.2.2.1.1 |
cpqSbDevBusIndexSCSI Device Bus Index
The bus index indicates which SCSI bus instance on an
adapter card this table entry belongs to. The instances start
at one and increment for each SCSI bus on a card.rodeprecated INTEGER .1.3.6.1.4.1.232.7.2.2.1.2 |
cpqSbDevScsiIdIndexSCSI Device Bus Physical Drive Index
The physical drive index indicates which physical drive instance
on a SCSI bus this table entry belongs to. The physical drive
index is the SCSI ID being used by that device.rodeprecated INTEGER .1.3.6.1.4.1.232.7.2.2.1.3 |
cpqSbDevTypeSCSI Device Type
This is the type of SCSI device. The following types are defined:
other(1)
The management agent does not recognize this type. You may
need to upgrade you software.
disk(2)
This is a direct-access device like a disk drive.
tape(3)
This is a sequential-access device like a tape drive.
printer(4)
This is a printer device.
processor(5)
This is a processor device like the ProLiant Storage System.
worm(6)
This is a write-once, read-many times device.
cd-rom(7)
This is a CD-ROM, read-only device.
scanner(8)
This is a scanner device.
optical(9)
This is an optical memory device.
jukeBox(10)
This is a medium changer device like a jukebox.
commDev(11)
This is a communications device like a LAN bridge.rodeprecated Enumeration .1.3.6.1.4.1.232.7.2.2.1.4 |
cpqSbDevModelSCSI Device Model
This is a description of the physical drive's model as returned by
the SCSI inquiry command. This can be used for identification
purposes.rodeprecated DisplayString .1.3.6.1.4.1.232.7.2.2.1.5 |
cpqSbDevFWRevSCSI Device Firmware Revision
This is the revision level of the physical drive as returned by
the SCSI inquiry command. This can be used for identification
purposes.rodeprecated DisplayString .1.3.6.1.4.1.232.7.2.2.1.6 |
cpqSbDevVendorSCSI Device Vendor.
This is the physical drive vendor's name as returned by
the SCSI inquiry command. This can be used for identification
purposes.rodeprecated DisplayString .1.3.6.1.4.1.232.7.2.2.1.7 |
cpqSbDevParityErrsSCSI Device Bus Parity Errors
This is the number of parity errors seen on the SCSI bus while
processing commands for this SCSI ID since the SCSI Interface
Module was loaded.
Parity errors may occasionally occur. If this value should rise
dramatically, you may have a problem. Some common causes include
radio frequency interference (RFI) on the bus cables, bad or missing
terminating resisters on the drives or having more than one device
with the same SCSI ID. Insure the bus cable is free of obstructions
and that the devices on the bus are properly configured.rodeprecated Counter .1.3.6.1.4.1.232.7.2.2.1.8 |
cpqSbDevPhaseErrsSCSI Device Bus Phase Errors
This is the number of times the SCSI bus entered an invalid operating
state while processing commands for the SCSI ID since the SCSI
Hardware Interface driver was loaded.
If you see any phase errors you may have a problem. Phase errors can
be caused by a device which is not operating correctly. If the phase
errors continue to increase the device should be replaced.rodeprecated Counter .1.3.6.1.4.1.232.7.2.2.1.9 |
cpqSbDevSelectTimeoutsSCSI Device Bus Select Time-outs
This is the number of times the controller attempted to start
communications with a device by selecting it but the device did not
respond.
If you see any select time-outs you may have a problem. The device
may have hung during operations. The SCSI controller will attempt to
reset the device but if this value continues to increment you may
need to power cycle the device.rodeprecated Counter .1.3.6.1.4.1.232.7.2.2.1.10 |
cpqSbDevMsgRejectsSCSI Device Bus Message Rejects
This is the number of times the device rejected a command because
it did not support the specified operation since the SCSI Hardware
Interface driver was loaded.
A large number for this object does not indicate a problem. It
only shows that the device does not support certain advanced SCSI
commands that the device driver issued.rodeprecated Counter .1.3.6.1.4.1.232.7.2.2.1.11 |
cpqSbDevNegPeriodSCSI Device Negotiated Period
This is the amount of time that was negotiated between the controller
and the device as a synchronous transfer window. A synchronous
transfer window is how long the device can transfer data without
requiring an acknowledgment from the controller. In general the
larger the negotiated period is, the higher the device throughput.rodeprecated INTEGER .1.3.6.1.4.1.232.7.2.2.1.12 |
cpqSbDevLocationSCSI Device Location
This is the physical location of where the device is located. The
following values are defined:
other(1) The drives are not located in any special product that
identifies the location.
proliant(2) The drives are located in the ProLiant Storage System.rodeprecated Enumeration .1.3.6.1.4.1.232.7.2.2.1.13 |