CPQIDE-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for CPQIDE-MIB.
92
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
92 total| Object Name |
|---|
cpqIdeDriveDegradedAn IDE drive status has been set to degraded.
User Action: The drive should be scheduled for replacement.
Refer to the appropriate Maintenance and Service Guide for
detailed information on a component replacement. TRAP-TYPE .1.3.6.1.4.1.232.0.14001 |
cpqIdeDriveOkAn IDE drive status has been set to ok.
User Action: None. TRAP-TYPE .1.3.6.1.4.1.232.0.14002 |
cpqIdeDriveUltraAtaDegradedAn IDE drive detects an excessive number of Ultra ATA
data transmission errors between the hard drive and the
processor.
User Action: For best performance move Ultra ATA devices to the
primary controller and non Ultra ATA devices to the secondary
controller. If errors still persist, consider replacing the
standard 40-conductor IDE cable with an 80-conductor Ultra ATA
cable. TRAP-TYPE .1.3.6.1.4.1.232.0.14003 |
cpqIdeAtaDiskStatusChangeATA Disk Status Change.
This trap signifies that the agent has detected a change in the
status of an ATA disk drive. The variable cpqIdeAtaDiskStatus
indicates the current disk drive status.
User Action: If the physical drive status is smartError(3) or
failed(4), replace the drive. TRAP-TYPE .1.3.6.1.4.1.232.0.14004 |
cpqIdeLogicalDriveStatusChangeIDE Logical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of an IDE logical drive. The variable
cpqIdeLogicalDriveStatus indicates the current logical drive
status.
User Action: If the logical drive status is failed(5), examine
the array for failed drives that need replacement. TRAP-TYPE .1.3.6.1.4.1.232.0.14005 |
cpqIde OBJECT IDENTIFIER .1.3.6.1.4.1.232.14 |
RFC1213-MIB Unknown .1.3.6.1.4.1.232.14 |
cpqIdeMibRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.1 |
cpqIdeMibRevMajorThe Major Revision level.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level.ro INTEGER .1.3.6.1.4.1.232.14.1.1 |
cpqIdeMibRevMinorThe Minor Revision level.
A change in the minor revision level may represent some minor
additional support; no changes to any pre-existing information
has occurred.ro INTEGER .1.3.6.1.4.1.232.14.1.2 |
cpqIdeMibConditionThe overall condition.
This object represents the overall status of the Ide system
represented by this MIB.ro Enumeration .1.3.6.1.4.1.232.14.1.3 |
cpqIdeComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2 |
cpqIdeInterface OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.1 |
cpqIdeOsCommon OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.1.4 |
cpqIdeOsCommonPollFreqThe Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero will always
fail, an agent may also choose to fail any request to change
the poll frequency to a value that would severely impact system
performance.rw INTEGER .1.3.6.1.4.1.232.14.2.1.4.1 |
cpqIdeOsCommonModuleTableA table of software modules that provide an interface to the
device this MIB describes.deprecated SEQUENCE OF CpqIdeOsCommonModuleEntry .1.3.6.1.4.1.232.14.2.1.4.2 |
cpqIdeOsCommonModuleEntryA description of a software modules that provide an interface
to the device this MIB describes.deprecated CpqIdeOsCommonModuleEntry .1.3.6.1.4.1.232.14.2.1.4.2.1 |
cpqIdeOsCommonModuleIndexA unique index for this module description.rodeprecated INTEGER .1.3.6.1.4.1.232.14.2.1.4.2.1.1 |
cpqIdeOsCommonModuleNameThe module name.rodeprecated DisplayString .1.3.6.1.4.1.232.14.2.1.4.2.1.2 |
cpqIdeOsCommonModuleVersionThe module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be a null (size 0) string if the agent
cannot provide the module version.rodeprecated DisplayString .1.3.6.1.4.1.232.14.2.1.4.2.1.3 |
cpqIdeOsCommonModuleDateThe module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant.rodeprecated OCTET STRING .1.3.6.1.4.1.232.14.2.1.4.2.1.4 |
cpqIdeOsCommonModulePurposeThe purpose of the module described in this entry.rodeprecated DisplayString .1.3.6.1.4.1.232.14.2.1.4.2.1.5 |
cpqIdeIdent OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.2 |
cpqIdeIdentTableIDE Drive Identification Table. SEQUENCE OF CpqIdeIdentEntry .1.3.6.1.4.1.232.14.2.2.1 |
cpqIdeIdentEntryIDE Identification Table Entry. CpqIdeIdentEntry .1.3.6.1.4.1.232.14.2.2.1.1 |
cpqIdeIdentIndexAn index that uniquely specifies each device. For disks,
this index value will match the value of the cpqSeFixedDiskIndex
in the Standard Equipment MIB (CPQSTDEQ.MIB) when the same
disk is being described.
Each possible index value indicates a specific drive as shown in
the table below:
Drive Index IDE Controller Drive Unit
=========== ============== ==========
0 Primary 1
1 Primary 2
2 Secondary 1
3 Secondary 2
Any other index value would be implementation specific.ro INTEGER .1.3.6.1.4.1.232.14.2.2.1.1.1 |
cpqIdeIdentModelIDE Drive Model.
The is the drive model name and can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.14.2.2.1.1.2 |
cpqIdeIdentSerNumIDE Drive Serial Number.
The is the drive serial number and can be used for identification
purposes.ro DisplayString .1.3.6.1.4.1.232.14.2.2.1.1.3 |
cpqIdeIdentFWVersIDE Firmware Version.
This is the version of the firmware on the IDE drive.
If the IDE drive firmware version is unavailable, then this
string will be of length zero (0).ro DisplayString .1.3.6.1.4.1.232.14.2.2.1.1.4 |
cpqIdeIdentConditionIDE Drive Condition.
This is the overall condition of the IDE drive.
The following values are defined:
other(1)
The drive does not support drive condition monitoring.
ok(2)
The drive is operating normally. No user action is required.
degraded(3)
The drive is degraded. The drive may need to be replaced.
failed(4)
The drive has failed. The drive should be replaced.rodeprecated Enumeration .1.3.6.1.4.1.232.14.2.2.1.1.5 |
cpqIdeIdentErrorNumberIDE Error Number.
This value represents the error code associated with a failing
IDE drive.ro DisplayString .1.3.6.1.4.1.232.14.2.2.1.1.6 |
cpqIdeIdentTypeIDE Device Type.
This is the type of ATAPI device. The following types are defined:
other(1)
The Insight agent does not recognize this type.
You may need to upgrade your software.
disk(2)
This is a direct-access device like a disk drive.
tape(3)
This is a sequential-access device like a tape drive.
printer(4)
This is a printer device.
processor(5)
This is a processor device.
worm(6)
This is a write-once, read-many times device.
cd-rom(7)
This is a CD or DVD device.
scanner(8)
This is a scanner device.
optical(9)
This is an optical memory device.
jukeBox(10)
This is a media changer device like a jukebox.
commDev(11)
This is a communications device like a LAN bridge.ro Enumeration .1.3.6.1.4.1.232.14.2.2.1.1.7 |
cpqIdeIdentTypeExtendedIDE Extended Device Type.
This is additional information about the type of IDE device.
The following types are defined:
other(1)
This target does not have any extended type information.
pdcd(2)
This is a power-drive CD-ROM.
removableDisk(3)
This is a removable media disk device like a floppy drive.ro Enumeration .1.3.6.1.4.1.232.14.2.2.1.1.8 |
cpqIdeIdentCondition2IDE Drive Condition.
This is the overall condition of the IDE drive.
The following values are defined:
other(1)
The drive does not support drive condition monitoring.
ok(2)
The drive is operating normally.
No user action is required.
degraded(3)
The drive is degraded.
See cpqIdeIdentStatus for the appropriate action.
failed(4)
The drive has failed.
See cpqIdeIdentStatus for the appropriate action.ro Enumeration .1.3.6.1.4.1.232.14.2.2.1.1.9 |
cpqIdeIdentStatusIDE Drive Satus.
This indicates the status of the IDE drive.
The following values are defined:
other(1)
The drive does not support drive status monitoring.
ok(2)
The drive is operating normally. No user action is required.
preFailureDegraded(3)
The drive has detected that at least one pre-failure SMART
attribute has gone out of range. The drive may need to be
replaced.
ultraAtaDegraded(4)
The Ultra ATA Integrity Monitor has detected data transmission
errors between the hard drive and processor. For best
performance, move Ultra ATA devices to the primary
controller and non Ultra ATA devices to the secondary
controller. If errors still persist, consider replacing the
standard 40-conductor cable with and 80-conductor cable.ro Enumeration .1.3.6.1.4.1.232.14.2.2.1.1.10 |
cpqIdeIdentUltraAtaAvailabilityThis describes the availability of Ultra ATA
transfers between this device and the controller.
The following values are defined:
other(1)
The agents do not support reporting this variable or the
agent need to be upgraded.
noNotSupportedByDeviceAndController(2),
The device and the controller do not support Ultra ATA.
noNotSupportedByDevice(3),
The device does not support Ultra ATA but the controller
does support Ultra ATA.
noNotSupportedByController(4),
The controller does not support Ultra ATA but the device
does support Ultra ATA.
NoDisabledInSetup(5),
The device and the controller do support Ultra ATA but it
has been disabled in F10 Setup.
yesEnabledInSetup(6),
The device and the controller do support Ultra ATA and it
is enabled in F10 Setup.ro Enumeration .1.3.6.1.4.1.232.14.2.2.1.1.11 |
cpqIdeController OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.3 |
cpqIdeControllerTableIDE Controller Table. SEQUENCE OF CpqIdeControllerEntry .1.3.6.1.4.1.232.14.2.3.1 |
cpqIdeControllerEntryIDE Controller Table Entry. CpqIdeControllerEntry .1.3.6.1.4.1.232.14.2.3.1.1 |
cpqIdeControllerIndexAn index that uniquely identifies each controller.ro INTEGER .1.3.6.1.4.1.232.14.2.3.1.1.1 |
cpqIdeControllerOverallConditionIDE Controller Overall Condition.
This is the overall condition of the IDE controller and any
associated devices.ro Enumeration .1.3.6.1.4.1.232.14.2.3.1.1.2 |
cpqIdeControllerModelIDE Controller Model.
The is the IDE controller model name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.3.1.1.3 |
cpqIdeControllerFwRevIDE Controller Firmware Revision.
The is the IDE controller firmware revision.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.3.1.1.4 |
cpqIdeControllerSlotIDE Controller Slot.
This identifies the physical slot where the IDE controller
resides in the system. For example, if this value is three,
the controller is located in slot three of your computer.
If the value cannot be determined or is not applicable, the
value is set to -1.ro INTEGER .1.3.6.1.4.1.232.14.2.3.1.1.5 |
cpqIdeControllerStatusIDE Channel Host Controller Status.
The host controller can be in one of the following states:
Other (1)
The agent is unable to determine the status of the controller.
OK (2)
Indicates that the controller is in normal operation mode.
Failed (3)
Indicates that the host controller has failed and should be
replaced.ro Enumeration .1.3.6.1.4.1.232.14.2.3.1.1.6 |
cpqIdeControllerConditionIDE Controller Condition.
This is the condition of the IDE controller.ro Enumeration .1.3.6.1.4.1.232.14.2.3.1.1.7 |
cpqIdeControllerSerialNumberIDE Controller Serial Number.
The is the IDE controller serial number. A NULL string
indicates that the serial number could not be determined or is
irrelevant.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.3.1.1.8 |
cpqIdeAtaDisk OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.4 |
cpqIdeAtaDiskTableIDE ATA Disk Table. SEQUENCE OF CpqIdeAtaDiskEntry .1.3.6.1.4.1.232.14.2.4.1 |
cpqIdeAtaDiskEntryIDE ATA Disk Table Entry. CpqIdeAtaDiskEntry .1.3.6.1.4.1.232.14.2.4.1.1 |
cpqIdeAtaDiskControllerIndexAn index that uniquely identifies each controller.ro INTEGER .1.3.6.1.4.1.232.14.2.4.1.1.1 |
cpqIdeAtaDiskIndexAn index that uniquely identifies each disk.ro INTEGER .1.3.6.1.4.1.232.14.2.4.1.1.2 |
cpqIdeAtaDiskModelATA Disk Model.
The is the model name of the ATA disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.4.1.1.3 |
cpqIdeAtaDiskFwRevATA Disk Firmware Revision.
The is the firmware revision of the ATA disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.4.1.1.4 |
cpqIdeAtaDiskSerialNumberATA Disk Serial Number.
The is the serial number of the ATA disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.4.1.1.5 |
cpqIdeAtaDiskStatusATA Disk Status.
This is the status of the ATA disk.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.6 |
cpqIdeAtaDiskConditionATA Disk Condition.
This is the condition of the ATA disk.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.7 |
cpqIdeAtaDiskCapacityATA Disk Capacity.
This is the capacity of the ATA disk in megabytes.ro INTEGER .1.3.6.1.4.1.232.14.2.4.1.1.8 |
cpqIdeAtaDiskSmartEnabledATA Disk S.M.A.R.T Enabled?
other(1)
The agent cannot determine the state of S.M.A.R.T. monitoring
on this ATA disk.
true(2)
The ATA disk has S.M.A.R.T motitoring enabled.
false(3)
The ATA disk does not have S.M.A.R.T motitoring enabled.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.9 |
cpqIdeAtaDiskTransferModeATA Disk Transfer Mode.
other(1)
The agent cannot determine the transfer mode on this ATA disk.
pioMode0(2)
The ATA disk is using PIO mode 0.
pioMode1(3)
The ATA disk is using PIO mode 1.
pioMode2(4)
The ATA disk is using PIO mode 2.
pioMode3(5)
The ATA disk is using PIO mode 3.
pioMode4(6)
The ATA disk is using PIO mode 4.
dmaMode0(7)
The ATA disk is using DMA mode 0.
dmaMode1(8)
The ATA disk is using DMA mode 1.
dmaMode2(9)
The ATA disk is using DMA mode 2.
ultraDmaMode0(10)
The ATA disk is using Ultra DMA mode 0.
ultraDmaMode1(11)
The ATA disk is using Ultra DMA mode 1.
ultraDmaMode2(12)
The ATA disk is using Ultra DMA mode 2.
ultraDmaMode3(13)
The ATA disk is using Ultra DMA mode 3.
ultraDmaMode4(14)
The ATA disk is using Ultra DMA mode 4.
ultraDmaMode5(15)
The ATA disk is using Ultra DMA mode 5.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.10 |
cpqIdeAtaDiskChannelATA Disk Channel.
other(1)
The agent cannot determine the channel to which the ATA disk
is attached.
channel0(2)
The ATA disk is attached to the primary channel.
channel1(3)
The ATA disk is attached to the secondary channel.
serial(4)
The disk is attached to the serial interface and channel no
longer applies.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.11 |
cpqIdeAtaDiskNumberATA Disk Number.
other(1)
The agent cannot determine the number of the ATA disk.
device0(2)
The ATA disk is device 0 (master).
device1(3)
The ATA disk is device 1 (slave).
sataDevice0(4)
The SATA disk is device 0.
sataDevice1(5)
The SATA disk is device 1.
sataDevice2(6)
The SATA disk is device 2.
sataDevice3(7)
The SATA disk is device 3.
sataDevice4(8)
The SATA disk is device 4.
sataDevice5(9)
The SATA disk is device 5.
sataDevice6(10)
The SATA disk is device 6.
sataDevice7(11)
The SATA disk is device 7.
bay1(21)
The disk is in bay 1.
bay2(22)
The disk is in bay 2.
bay3(23)
The disk is in bay 3.
bay4(24)
The disk is in bay 4.
bay5(25)
The disk is in bay 5.
bay6(26)
The disk is in bay 6.
bay7(27)
The disk is in bay 7.
bay8(28)
The disk is in bay 8.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.12 |
cpqIdeAtaDiskLogicalDriveMemberLogical Drive Membership?
other(1)
The agent cannot determine if the ATA disk is part of a
logical drive.
true(2)
The ATA disk is part of a logical drive.
false(3)
The ATA disk is not part of a logical drive.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.13 |
cpqIdeAtaDiskIsSpareATA Disk Spare?
other(1)
The agent cannot determine if the ATA disk is a spare.
true(2)
The ATA disk is a spare disk.
false(3)
The ATA disk is not a spare disk.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.14 |
cpqIdeAtaDiskOsNameATA Disk OS Name.
The OS name for this ATA disk. This field will be a null
(size 0) string if the agent does not support OS name or if the
ATA disk is part of a logical drive.ro DisplayString .1.3.6.1.4.1.232.14.2.4.1.1.15 |
cpqIdeAtaDiskTypeATA Disk Type
other(1)
The agent cannot determine the disk type.
ata(2)
The disk type is parallel ATA.
sata(3)
The disk type is Serial ATA.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.16 |
cpqIdeAtaDiskSataVersionPhysical Drive SATA Version.
The following values are defined:
other(1)
The agent is unable to determine the SATA version for this
disk or it is not a SATA disk.
sataOne(2)
The disk is SATA version one.
sataTwo(3)
The disk is SATA version two.ro Enumeration .1.3.6.1.4.1.232.14.2.4.1.1.17 |
cpqIdeAtapiDevice OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.5 |
cpqIdeAtapiDeviceTableIDE ATAPI Device Table. SEQUENCE OF CpqIdeAtapiDeviceEntry .1.3.6.1.4.1.232.14.2.5.1 |
cpqIdeAtapiDeviceEntryIDE ATAPI Device Table Entry. CpqIdeAtapiDeviceEntry .1.3.6.1.4.1.232.14.2.5.1.1 |
cpqIdeAtapiDeviceControllerIndexAn index that uniquely identifies each controller.ro INTEGER .1.3.6.1.4.1.232.14.2.5.1.1.1 |
cpqIdeAtapiDeviceIndexAn index that uniquely identifies each ATAPI device.ro INTEGER .1.3.6.1.4.1.232.14.2.5.1.1.2 |
cpqIdeAtapiDeviceModelATAPI Device Model.
The is the model name of the ATAPI device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.5.1.1.3 |
cpqIdeAtapiDeviceFwRevATAPI Device Firmware Revision.
The is the firmware revision of the ATAPI device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.232.14.2.5.1.1.4 |
cpqIdeAtapiDeviceTypeATAPI Device Type.
This is the type of ATAPI device. The following types are defined:
other(1)
The agent does not recognize this type.
You may need to upgrade your software.
disk(2)
This is a direct-access device like a disk drive.
tape(3)
This is a sequential-access device like a tape drive.
printer(4)
This is a printer device.
processor(5)
This is a processor device.
worm(6)
This is a write-once, read-many times device.
cd-rom(7)
This is a CD or DVD device.
scanner(8)
This is a scanner device.
optical(9)
This is an optical memory device.
jukeBox(10)
This is a media changer device like a jukebox.
commDev(11)
This is a communications device like a LAN bridge.ro Enumeration .1.3.6.1.4.1.232.14.2.5.1.1.5 |
cpqIdeAtapiDeviceTypeExtendedATAPI Extended Device Type.
This is additional information about the type of ATAPI device.
The following types are defined:
other(1)
This target does not have any extended type information.
pdcd(2)
This is a power-drive CD-ROM.
removableDisk(3)
This is a removable media disk device like a floppy drive.ro Enumeration .1.3.6.1.4.1.232.14.2.5.1.1.6 |
cpqIdeAtapiDeviceChannelATAPI Device Channel.
other(1)
The agent cannot determine the channel to which the ATAPI
device is attached.
channel0(2)
The ATAPI device is attached to the primary channel.
channel1(3)
The ATAPI device is attached to the secondary channel.ro Enumeration .1.3.6.1.4.1.232.14.2.5.1.1.7 |
cpqIdeAtapiDeviceNumberATAPI Device Number.
other(1)
The agent cannot determine the number of the ATAPI device.
device0(2)
The ATAPI device is device 0 (master).
device1(3)
The ATAPI device is device 1 (slave).ro Enumeration .1.3.6.1.4.1.232.14.2.5.1.1.8 |
cpqIdeLogicalDrive OBJECT IDENTIFIER .1.3.6.1.4.1.232.14.2.6 |
cpqIdeLogicalDriveTableIDE Logical Drive Table. SEQUENCE OF CpqIdeLogicalDriveEntry .1.3.6.1.4.1.232.14.2.6.1 |
cpqIdeLogicalDriveEntryIDE Logical Drive Table Entry. CpqIdeLogicalDriveEntry .1.3.6.1.4.1.232.14.2.6.1.1 |
cpqIdeLogicalDriveControllerIndexAn index that uniquely identifies each controller.ro INTEGER .1.3.6.1.4.1.232.14.2.6.1.1.1 |
cpqIdeLogicalDriveIndexAn index that uniquely identifies each logical drive.ro INTEGER .1.3.6.1.4.1.232.14.2.6.1.1.2 |
cpqIdeLogicalDriveRaidLevelIDE Logical Drive RAID Level.
The following RAID levels are defined:
other(1)
The agent cannot determine the RAID level of this logical drive.
raid0(2)
The logical drive is configured with RAID level 0.
raid1(3)
The logical drive is configured with RAID level 1.
raid0plus1(4)
The logical drive is configured with RAID level 0 plus 1.
raid5(5)
The logical drive is configured with RAID level 5.
raid15(6)
The logical drive is configured with RAID level 1 plus 5.
volume(7)
The logical drive is configured as a volume set.ro Enumeration .1.3.6.1.4.1.232.14.2.6.1.1.3 |
cpqIdeLogicalDriveCapacityIDE Logical Drive Capacity.
This is the capacity of the logical drive in megabytes.ro INTEGER .1.3.6.1.4.1.232.14.2.6.1.1.4 |
cpqIdeLogicalDriveStatusIDE Logical Drive Status.
This is the status of the logical drive.
other(1)
The agent cannot determine the logical drive status.
ok(2)
Indicates that the logical drive is in normal operation mode.
degraded(3)
Indicates that at least one physical drive has failed, but the
logical drive's RAID level lets the drive continue to operate
with no data loss.
rebuilding(4)
Indicates that the logical drive is rebuilding a physical drive.
When complete, the logical drive will return to normal
operation.
failed(5)
Indicates that more physical drives have failed than the RAID
level of the logical drive can handle without data loss.ro Enumeration .1.3.6.1.4.1.232.14.2.6.1.1.5 |
cpqIdeLogicalDriveConditionIDE Logical Drive Condition.
This is the condition of the logical drive.ro Enumeration .1.3.6.1.4.1.232.14.2.6.1.1.6 |
cpqIdeLogicalDriveDiskIdsIDE Logical Drive Disk ID list.
This lists the ATA disks drive IDs which are associated with this
logical drive. These are the same IDs which can be used as
indices into the ATA disk table (cpqIdeAtaDiskIndex). Each byte
of the string is an index.ro OCTET STRING .1.3.6.1.4.1.232.14.2.6.1.1.7 |
cpqIdeLogicalDriveStripeSizeIDE Logical Drive Stripe Size.
This is the stripe size in kilobytes.ro INTEGER .1.3.6.1.4.1.232.14.2.6.1.1.8 |
cpqIdeLogicalDriveSpareIdsIDE Logical Drive Spare ID list.
This lists the ATA disks drive IDs which are possible spares for
this logical drive. These are the same IDs which can be used as
indices into the ATA disk table (cpqIdeAtaDiskIndex). Each byte
of the string is an index.ro OCTET STRING .1.3.6.1.4.1.232.14.2.6.1.1.9 |
cpqIdeLogicalDriveRebuildingDiskIDE Logical Drive Rebuilding Disk.
This is the ATA disk that is in the process of rebuilding. If no
drive is currently rebuilding, a value of -1 will be returned.ro INTEGER .1.3.6.1.4.1.232.14.2.6.1.1.10 |
cpqIdeLogicalDriveOsNameIDE Logical Drive OS Name.
The OS name for this logical drive. This field will be a null
(size 0) string if the agent does not support OS name.ro DisplayString .1.3.6.1.4.1.232.14.2.6.1.1.11 |