CPQCR-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
129
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
129 total| Object Name |
|---|
cpqClusteredRAID OBJECT IDENTIFIER .1.3.6.1.4.1.232.141 |
RFC1213-MIB Unknown .1.3.6.1.4.1.232.141 |
cpqCrMibRev OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.1 |
cpqCrMibRevMajorThe Major Revision level.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level.ro INTEGER .1.3.6.1.4.1.232.141.1.1 |
cpqCrMibRevMinorThe Minor Revision level.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred.ro INTEGER .1.3.6.1.4.1.232.141.1.2 |
cpqCrMibConditionThe overall condition (status) of the system represented by
this MIB.ro Enumeration .1.3.6.1.4.1.232.141.1.3 |
cpqCrComponent OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2 |
cpqCrInterface OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.1 |
cpqCrOsCommon OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.1.4 |
cpqCrOsCommonPollFreqThe Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
The polling frequency is set in a configuration file used by
the agent.rw INTEGER .1.3.6.1.4.1.232.141.2.1.4.1 |
cpqCrCntlr OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.2 |
cpqCrCntlrTableClustered RAID Array Controller Table. SEQUENCE OF CpqCrCntlrEntry .1.3.6.1.4.1.232.141.2.2.1 |
cpqCrCntlrEntryClustered RAID Array Controller Entry. CpqCrCntlrEntry .1.3.6.1.4.1.232.141.2.2.1.1 |
cpqCrCntlrIndexClustered RAID Array Controller Index.
This value is a logical number whose meaning is OS dependent.
Each physical controller has one unique controller number
associated with it.ro INTEGER .1.3.6.1.4.1.232.141.2.2.1.1.1 |
cpqCrCntlrSerialNumberCR3500 Controller Serial Number.ro DisplayString .1.3.6.1.4.1.232.141.2.2.1.1.2 |
cpqCrCntlrFWRevClustered RAID Array Controller Firmware Revision.
The firmware revision of the Clustered RAID Controller.
This value can be used to help identify a particular revision
of the controller.ro DisplayString .1.3.6.1.4.1.232.141.2.2.1.1.3 |
cpqCrCntlrConditionThe condition of the device. This value represents the overall
condition of this controller, and any associated logical drives,
physical drives, and array accelerators.ro Enumeration .1.3.6.1.4.1.232.141.2.2.1.1.4 |
cpqCrCntlrCurrentRoleClustered RAID Array Controller Current Role.
For duplexed array controllers, this is the controllers current
role. The following values are valid:
other (1)
Indicates that the instrument agent does not recognize the
role of the controller. You may need to upgrade the instrument
agent.
notDuplexed (2)
This array controller is not duplexed.
active (3)
This duplexed array controller is the active controller.
backup (4)
This duplexed array controller is the backup controller.ro Enumeration .1.3.6.1.4.1.232.141.2.2.1.1.8 |
cpqCrCntlrDriveOwnershipClustered RAID Array Controller Drive Ownership.
For duplexed controllers, indicates to which controller slot
the shared devices are associated.
The following values are valid:
other (1)
Indicates that the instrument agent does not recognize the
status of the controller. You may need to upgrade the instrument
agent.
owner (2)
All the logical, physical and spare drives are associated
with this controller.
notOwner (3)
The logical, physical and spare drives are not associated
with this controller.ro Enumeration .1.3.6.1.4.1.232.141.2.2.1.1.9 |
cpqCrCntlrRebuildRateClustered RAID Array Controller Rebuild Rate.
Determines the rate at which disks are to be rebuilt if
there is I/O activity.
1 = Minimum rate
100 = Maximum ratero INTEGER .1.3.6.1.4.1.232.141.2.2.1.1.10 |
cpqCrCntlrCreateRateClustered RAID Array Controller Create Rate.
Determines the rate at which RAIDsets are to be created if
there is I/O activity.
1 = Minimum rate
100 = maximum ratero INTEGER .1.3.6.1.4.1.232.141.2.2.1.1.11 |
cpqCrCntlrCacheSizeClustered RAID Array Controller Cache Size.
Size of the controller's cache in MB.ro INTEGER .1.3.6.1.4.1.232.141.2.2.1.1.12 |
cpqCrCntlrSimmSizeAClustered RAID Array Controller Memory Module Size.
Size of the memory module in slot A in MB.ro INTEGER .1.3.6.1.4.1.232.141.2.2.1.1.13 |
cpqCrCntlrSimmSizeBClustered RAID Array Controller Memory Module Size.
Size of the memory module in slot B in MB.ro INTEGER .1.3.6.1.4.1.232.141.2.2.1.1.14 |
cpqCrLogDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.3 |
cpqCrLogDrvTableClustered RAID RAIDset Table.
A table of RAIDset entries. SEQUENCE OF CpqCrLogDrvEntry .1.3.6.1.4.1.232.141.2.3.1 |
cpqCrLogDrvEntryClustered RAID RAIDset Entry.
A RAIDset entry. CpqCrLogDrvEntry .1.3.6.1.4.1.232.141.2.3.1.1 |
cpqCrLogDrvCntlrIndexClustered RAID RAIDset Controller Index.
This maps the RAIDsets into their respective controllers.
Controller index 'i' under the controller group owns the
associated drives in the RAIDset which use that index.ro INTEGER .1.3.6.1.4.1.232.141.2.3.1.1.1 |
cpqCrLogDrvIndexClustered RAID RAIDset Index.
This logical drive number keeps track of multiple instances of
logical drives which are on the same controller. For each
controller index value, the logical drive index starts at 1 and
increments for each logical drive.ro INTEGER .1.3.6.1.4.1.232.141.2.3.1.1.2 |
cpqCrLogDrvRAIDLevelRAID Level.
This shows the RAID level of the RAIDset.
To change the RAID level, run the CL1850 Array
Configuration Utility.
The following values are valid for the RAIDset RAID
Level:
JBOD (2)
Just a Bunch of Drives. Fault tolerance is not enabled. This
RAIDset is made up of one device. Does not provide extended data
redundancy, availability or protection, and does not use striping
for performance enhancements.
Good for applications requiring high device capacity. Requires one
and only one device.
RAID0 (3)
A RAIDset using device striping and write-back caching.
Data is spread across many devices, offering faster read/write
performance than a single device. Does not provide extended data
redundancy, availability or protection. Good for applications with
large files needing high I/O performance. Requires a minimum of
two devices.
RAID1 (4)
A RAIDset using device mirroring. Any time data is written to
a device, a duplicate write is also made to a second device. Reading
from multiple devices is usually faster than reading from a single
device. Provides extended data redundancy, availability and
protection. Good for read-intensive applications needing high
availability. Requires a minimum of two devices.
RAID0PLUS1 (5)
A RAIDset where data is striped across devices and duplicated
on an equivalent number of devies. Provides extended data
redundancy, availability and protection. Good for applications
requiring high availability, high performance and capacity.
Requires an even number of devices, and a minimum of four devices.
RAID4 (6)
A RAIDset using device striping, with one device assigned for
parity. Provides extended data redundancy, availability and
protection. Good for applications such as graphics and imaging that
call for writing huge, sequential blocks of data. Requires a minimum
of three devices.
RAID5(7)
A RAIDset using device striping, with parity distributed across
devices. Provides extended data redundancy, availability and
protection. Good for transaction processing, applications requiring
many, small I/O operations scattered randomly and widely across the
devices. Requires a minimum of three devices.ro Enumeration .1.3.6.1.4.1.232.141.2.3.1.1.3 |
cpqCrLogDrvStatusRAIDset Status.
The RAIDset can be in one of the following states:
Good (2)
Indicates that the RAIDset is fully operational.
Reduced (3)
Indicates that the RAIDset is operating in a degraded or
reduced state. One or more of the physical disks which make
up the RAIDset are either missing or failed, but the
RAIDset can continue to operate without data loss.
Failed (4)
Indicates that the RAIDset is not operational.
Reconstructing (5)
Indicates that the RAIDset is regenerating a failed
physical drive's data onto a replacement drive that is part
of the RAIDset.
All user data remains available during the reconstruction
process, but some performance reduction may occur when a
request requires access to the device being reconstructed.
Initializing (6)
Indicates that the controller is writing its file structure
onto the RAIDset's member devices.ro Enumeration .1.3.6.1.4.1.232.141.2.3.1.1.4 |
cpqCrLogDrvRebuildPercentageRAIDset Rebuild Percentage Complete.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value shows how far
the rebuild process has progressed as a percentage.
When the value reaches 100, the rebuilding process is complete.
The drive array continues to operate in reduced mode while a
drive is rebuilding.
This value is only valid if the RAIDset Status is
reconstructing (6).ro INTEGER .1.3.6.1.4.1.232.141.2.3.1.1.5 |
cpqCrLogDrvAvailSparesRAIDset Available Spares.
This indicates if this RAIDset has one or more spares
designated for it that are not currently in use by another drive.
Each octet present will be a physical drive ID that is an
available spare for this logical drive. These are the same ID's
which can be used as indexes into the physical drive table.
An octet string of length zero indicates that there are no
available spares for this logical drive.ro OCTET STRING .1.3.6.1.4.1.232.141.2.3.1.1.7 |
cpqCrLogDrvSizeRAIDset Size.
This is the size of the RAIDset in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a
megabyte when giving drive capacities so this value may
differ from the advertised size of a drive.ro INTEGER .1.3.6.1.4.1.232.141.2.3.1.1.8 |
cpqCrLogDrvPhyDrvIDsRAIDset Physical Drive IDs.
This lists the physical drive IDs which are associated with this
RAIDset. These are the same IDs which can be used as
indices into the physical drive table. Each byte of the string
is an index.ro OCTET STRING .1.3.6.1.4.1.232.141.2.3.1.1.9 |
cpqCrLogDrvConditionRAIDset condition.
This value represents the overall condition of this RAIDset
and any associated physical drives.ro Enumeration .1.3.6.1.4.1.232.141.2.3.1.1.10 |
cpqCrLogDrvPartitionIDsRAIDset Logical Drive IDs.
This lists the logical drive IDs which are associated with this
RAIDset. These are the same IDs which can be used as
indices into the logical drive table. Each byte of the string
is an index.ro OCTET STRING .1.3.6.1.4.1.232.141.2.3.1.1.11 |
cpqCrSpareDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.4 |
cpqCrSpareTableClustered RAID Spare Table.
A table of spare entries. SEQUENCE OF CpqCrSpareEntry .1.3.6.1.4.1.232.141.2.4.1 |
cpqCrSpareEntryClustered RAID Spare Entry.
An entry in the spare table. CpqCrSpareEntry .1.3.6.1.4.1.232.141.2.4.1.1 |
cpqCrSpareCntlrIndexSpare Controller Index.
This index maps the spare drive back to the controller to which
it is attached. The value of this index is the same as the one
used under the controller group.ro INTEGER .1.3.6.1.4.1.232.141.2.4.1.1.1 |
cpqCrSparePhyDrvIndexPhysical Drive Index.
This index maps the spare to the physical drive it represents.
The value of this index is the same as the one used with the
physical drive table.ro INTEGER .1.3.6.1.4.1.232.141.2.4.1.1.2 |
cpqCrSpareStatusSpare Status.
This shows the status of the on-line spare drive.
The following values are valid for the spare status:
Hot Spare(5)
The drive attached to this channel is kept spinning
whenever the controller is powered up and it is to
be automatically brought online to replace a failed drive.
Warm Spare(6)
The drive attached to this channel is not spun up
until a disk in the array fails and it is automatically
brought online to replace a failed drive.
Adding Spare(9)
The drive is in the process of becoming a spare drive.ro Enumeration .1.3.6.1.4.1.232.141.2.4.1.1.3 |
cpqCrSpareConditionSpare Drive condition.
This value represents the overall condition of this spare drive
and any associated physical drives.ro Enumeration .1.3.6.1.4.1.232.141.2.4.1.1.4 |
cpqCrSpareScsiIDSCSI ID.
This value represents the SCSI identifier of this spare drive.ro INTEGER .1.3.6.1.4.1.232.141.2.4.1.1.5 |
cpqCrPhyDrv OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.5 |
cpqCrPhyDrvTableClustered RAID Physical Drive Table.
A table of physical drive entries. SEQUENCE OF CpqCrPhyDrvEntry .1.3.6.1.4.1.232.141.2.5.1 |
cpqCrPhyDrvEntryClustered RAID Physical Drive Entry.
A physical drive entry. CpqCrPhyDrvEntry .1.3.6.1.4.1.232.141.2.5.1.1 |
cpqCrPhyDrvCntlrIndexClustered RAID Physical Drive Controller Index.
This index maps the physical drive back to the controller to
which it is attached. The value of this index is the same as
the one used under the controller group.ro INTEGER .1.3.6.1.4.1.232.141.2.5.1.1.1 |
cpqCrPhyDrvIndexClustered RAID Physical Drive Index.
This index is used for selecting the physical drive table entry.
This number, along with the cpqCrPhyDrvCntlrIndex uniquely
identify a specific physical drive.ro INTEGER .1.3.6.1.4.1.232.141.2.5.1.1.2 |
cpqCrPhyDrvVendorPhysical Drive Vendor.
This is the name of the manufacturer of the physical drive.
This value is based upon the vendor name as returned by the
SCSI inquiry command but may have been modified due to space
limitations. This can be used for identification purposes.ro DisplayString .1.3.6.1.4.1.232.141.2.5.1.1.3 |
cpqCrPhyDrvModelPhysical Drive Model.
This is a text description of the physical drive. The text that
appears depends upon who manufactured the drive and the drive
type.
For example, you might see: CP3201.
If a drive fails, note the model to identify the type of drive
necessary for replacement.ro DisplayString .1.3.6.1.4.1.232.141.2.5.1.1.4 |
cpqCrPhyDrvRevisionPhysical Drive Revision.
This shows the physical drive revision number.ro DisplayString .1.3.6.1.4.1.232.141.2.5.1.1.5 |
cpqCrPhyDrvStatusPhysical Drive Status.
This shows the status of the physical drive.
The following values are valid for the physical drive status:
Offline (3)
The drive attached to this channel is not a member of the
RAID set.
Online (4)
The drive attached to this channel is a fully functional
member of this RAID set.
Creating (5)
The drive is currently being created as part of a RAID set.
Rebuilding (6)
The drive is currently being rebuilt.
Formatting (8)
The drive is currently being formattedro Enumeration .1.3.6.1.4.1.232.141.2.5.1.1.6 |
cpqCrPhyDrvSizePhysical Drive Size in MB.
This is the size of the physical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a
megabyte when giving drive capacities so this value may differ
from the advertised size of a drive. This field is only
applicable for controllers which support SCSI drives, and
therefore is not supported by the IDA or IDA-2 controllers.
The field will contain 0xFFFFFFFF if the drive capacity cannot
be calculated or if the controller does not support SCSI drives.ro INTEGER .1.3.6.1.4.1.232.141.2.5.1.1.7 |
cpqCrPhyDrvConditionPhysical Drive condition.
This value represents the overall condition of this physical drive.ro Enumeration .1.3.6.1.4.1.232.141.2.5.1.1.8 |
cpqCrPhyDrvScsiIDSCSI ID.
This value represents the SCSI identifier of this physical
drive.ro INTEGER .1.3.6.1.4.1.232.141.2.5.1.1.9 |
cpqCrEMU OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.7 |
cpqCrEMUBoardTemperatureStatusEnvironmental Monitoring Unit (EMU) Board Temperature status.
The System Board Temperature status as determined by the EMU is:
Not Installed (2)
The board temperature can not be detected in the unit.
Normal (3)
The board temperature detected by the EMU is normal.
Below Normal (4)
The board temperature detected by the EMU is below normal.
Above Normal (5)
The board temperature detected by the EMU is above normal.
Far Below Normal (6)
The board temperature detected by the EMU is far below normal.
Far Above Normal (7)
The board temperature detected by the EMU is far above normal.
Back To Normal (8)
The board temperature detected by the EMU has returned to normal.rodeprecated Enumeration .1.3.6.1.4.1.232.141.2.7.1 |
cpqCrEMUEnclosureTemperatureStatusEnvironmental Monitoring Unit (EMU) Enclosure Temperature status.
The Enclosure Housing Temperature status as determined by the EMU is:
Not Installed (2)
The enclosure temperature can not be detected in the unit.
Normal (3)
The enclosure temperature detected by the EMU is normal.
Below Normal (4)
The enclosure temperature detected by the EMU is below normal.
Above Normal (5)
The enclosure temperature detected by the EMU is above normal.
Far Below Normal (6)
The enclosure temperature detected by the EMU is far below normal.
Far Above Normal (7)
The enclosure temperature detected by the EMU is far above normal.
Back To Normal (8)
The enclosure temperature detected by the EMU has returned to normal.rodeprecated Enumeration .1.3.6.1.4.1.232.141.2.7.2 |
cpqCrEMUBoardTemperatureLevelEnvironmental Monitoring Unit (EMU) Board Temperature.
Indicates the System Board temperature in degrees Fahrenheit.rodeprecated INTEGER .1.3.6.1.4.1.232.141.2.7.3 |
cpqCrEMUEnclosureTemperatureLevelEnvironmental Monitoring Unit (EMU) Enclosure Temperature.
Indicates the Enclosure Housing temperature in degrees Fahrenheit.rodeprecated INTEGER .1.3.6.1.4.1.232.141.2.7.4 |
cpqCrEMUConditionPrimary enclosure condition.
This value represents the overall condition of the primary
enclosure.ro Enumeration .1.3.6.1.4.1.232.141.2.7.5 |
cpqCrEMUFanStatusPrimary enclosure fan status.
The primary enclosure fan status is:
OK (2)
Status is normal.
Critical (3)
Fan has failed.
Unknown (4)
Information unavailable.ro Enumeration .1.3.6.1.4.1.232.141.2.7.6 |
cpqCrEMUFanConditionPrimary enclosure fan condition.
This value represents the overall condition of the fan
in the primary enclosure.ro Enumeration .1.3.6.1.4.1.232.141.2.7.7 |
cpqCrEMUPowerSupplyStatusPrimary enclosure power supply status.
The primary enclosure power supply status is:
OK (2)
Status is normal.
Critical (3)
Power supply is installed and marked as failed.
Not Installed (4)
One of the redundant power supplies has been removed.
Unknown (5)
Information unavailable.ro Enumeration .1.3.6.1.4.1.232.141.2.7.8 |
cpqCrEMUPowerSupplyConditionPrimary enclosure power supply condition.
This value represents the overall condition of the power
supply in the primary enclosure.ro Enumeration .1.3.6.1.4.1.232.141.2.7.9 |
cpqCrEMUTemperatureStatusPrimary enclosure temperature status.
The primary enclosure temperature status is:
OK (2)
Status is normal.
Critical (3)
Controller temperature sensor has detected a critical
temperature condition in the primary enclosure.
Non-critical (4)
Controller temperature sensor has detected an abnormal
temperature condition in the primary enclosure.
Unknown (5)
Information unavailable.ro Enumeration .1.3.6.1.4.1.232.141.2.7.10 |
cpqCrEMUTemperatureLevelPrimary enclosure temperature.
Indicates the temperature within the primary enclosure in degrees
Celsius.ro INTEGER .1.3.6.1.4.1.232.141.2.7.11 |
cpqCrEMUTemperatureConditionPrimary enclosure temperature condition.
This value represents the overall condition of the
temperature in the primary enclosure.ro Enumeration .1.3.6.1.4.1.232.141.2.7.12 |
cpqCrExpCab OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.8 |
cpqCrExpCabPowerSupplyStatusExpansion Cabinet power supply status.
The expansion cabinet power supply status is:
OK (2)
Status is normal. Either redundant power supplies are
installed and reporting no error or a single power
supply is installed.
Non-Critical (3)
Redundant power supplies are installed and reporting
a fault.
Unknown (5)
Information unavailable.ro Enumeration .1.3.6.1.4.1.232.141.2.8.1 |
cpqCrExpCabFanStatusExpansion Cabinet fan status.
The expansion cabinet fan status is:
OK (2)
Status is normal. One or more fans is installed and no
error is reported.
Non-Critical (4)
Fan degraded condition. One or more fans are reporting an
error or only one fan is installed.
Not Installed (5)
Fan valid bit not set.
Unknown (6)
Information unavailable.ro Enumeration .1.3.6.1.4.1.232.141.2.8.2 |
cpqCrExpCabTemperatureStatusExpansion Cabinet temperature status.
The expansion cabinet temperature status is:
OK (2)
Status is normal.
Critical (3)
Critical temperature condition reported.
Non-Critical (4)
Warning temperature condition reported.
Not Installed (5)
Temperature valid bit not set.
Unknown (6)
Information unavailable.ro Enumeration .1.3.6.1.4.1.232.141.2.8.3 |
cpqCrExpCabConditionExpansion Cabinet condition.
This value represents the overall condition of the
expansion cabinet.ro Enumeration .1.3.6.1.4.1.232.141.2.8.6 |
cpqCrExpCabPowerSupplyConditionExpansion Cabinet power supply condition.
This value represents the overall condition of the
power supply in the expansion cabinet.ro Enumeration .1.3.6.1.4.1.232.141.2.8.7 |
cpqCrExpCabFanConditionExpansion Cabinet fan condition.
This value represents the overall condition of the
fan in the expansion cabinet.ro Enumeration .1.3.6.1.4.1.232.141.2.8.9 |
cpqCrExpCabTemperatureConditionExpansion Cabinet temperature condition.
This value represents the overall condition of the
temperature in the expansion cabinet.ro Enumeration .1.3.6.1.4.1.232.141.2.8.10 |
cpqCrPartition OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.2.9 |
cpqCrPartitionTableClustered RAID Logical Drive Table.
A table of logical drive entries. SEQUENCE OF CpqCrPartitionEntry .1.3.6.1.4.1.232.141.2.9.1 |
cpqCrPartitionEntryClustered RAID Logical Drive Entry.
A Logical Drive entry. CpqCrPartitionEntry .1.3.6.1.4.1.232.141.2.9.1.1 |
cpqCrPartitionLogDrvIndexClustered RAID Logical Drive Index.
This maps the logical drives into their respective RAIDsets.
RAIDset index 'i' under the RAIDset group owns the
associated drives in the logical drives which use that index.ro INTEGER .1.3.6.1.4.1.232.141.2.9.1.1.1 |
cpqCrPartitionIndexClustered RAID Logical Drive Index.
This logical drive number keeps track of multiple instances of
logical drives which are part of the same RAIDset. For each
RAIDset index value, the logical drive index starts at 1 and
increments for each logical drive.ro INTEGER .1.3.6.1.4.1.232.141.2.9.1.1.2 |
cpqCrPartitionRAIDLevelLogical Drive RAID Level.
This shows the RAID level of the logical drive.
To change the RAID level, run the CR3500 Array
Configuration Utility.
The following values are valid for the logical drive RAID
Level:
JBOD (2)
Just a Bunch of Drives. Fault tolerance is not enabled. This
logicl drive is made up of one device. Does not provide extended data
redundancy, availability or protection, and does not use striping
for performance enhancements.
Good for applications requiring high device capacity. Requires one
and only one device.
RAID0 (3)
A logical drive using device striping and write-back caching.
Data is spread across many devices, offering faster read/write
performance than a single device. Does not provide extended data
redundancy, availability or protection. Good for applications with
large files needing high I/O performance. Requires a minimum of
two devices.
RAID1 (4)
A logical drive using device mirroring. Any time data is written to
a device, a duplicate write is also made to a second device. Reading
from multiple devices is usually faster than reading from a single
device. Provides extended data redundancy, availability and
protection. Good for read-intensive applications needing high
availability. Requires a minimum of two devices.
RAID0PLUS1 (5)
A logical drive where data is striped across devices and duplicated
on an equivalent number of devies. Provides extended data
redundancy, availability and protection. Good for applications
requiring high availability, high performance and capacity.
Requires an even number of devices, and a minimum of four devices.
RAID4 (6)
A logical drive using device striping, with one device assigned for
parity. Provides extended data redundancy, availability and
protection. Good for applications such as graphics and imaging that
call for writing huge, sequential blocks of data. Requires a minimum
of three devices.
RAID5(7)
A logical drive using device striping, with parity distributed across
devices. Provides extended data redundancy, availability and
protection. Good for transaction processing, applications requiring
many, small I/O operations scattered randomly and widely across the
devices. Requires a minimum of three devices.ro Enumeration .1.3.6.1.4.1.232.141.2.9.1.1.3 |
cpqCrPartitionStatusLogical Drive Status.
The logical drive can be in one of the following states:
Good (2)
Indicates that the logical drive is fully operational.
Reduced (3)
Indicates that the logical drive is operating in a degraded or
reduced state. One or more of the physical disks which make
up the logical drive are either missing or failed, but the
logical drive can continue to operate without data loss.
Failed (4)
Indicates that the logical drive is not operational.
Reconstructing (5)
Indicates that the logical drive is regenerating a failed
physical drive's data onto a replacement drive that is part
of the logical drive.
All user data remains available during the reconstruction
process, but some performance reduction may occur when a
request requires access to the device being reconstructed.
Initializing (6)
Indicates that the controller is writing its file structure
onto the logical drive's member devices.ro Enumeration .1.3.6.1.4.1.232.141.2.9.1.1.4 |
cpqCrPartitionSizeLogical Drive Size.
This is the size of the logical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a
megabyte when giving drive capacities so this value may
differ from the advertised size of a drive.ro INTEGER .1.3.6.1.4.1.232.141.2.9.1.1.5 |
cpqCrPartitionConditionLogical drive condition.
This value represents the overall condition of this logical
drive and any associated physical drives.ro Enumeration .1.3.6.1.4.1.232.141.2.9.1.1.6 |
cpqCrTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3 |
cpqCrInterfaceTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.1 |
cpqCrCntlrTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.2 |
cpqCrController1FailureTrapThe primary controller in the subsytem has failed.
Details:
The primary Controller has failed.
User Action:
Replace controller. Possible causes are controller physically
removed, actual hardware failure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.2.0.1 |
cpqCrController1InformationTrapThe primary controller in the subsytem has recovered.
Details:
The primary controller has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.2.0.2 |
cpqCrController2FailureTrapThe secondary controller in the subsytem has failed.
Details:
The secondary controller has failed.
User Action:
Replace controller. Possible causes are controller
physically removed, actual hardware failure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.2.0.3 |
cpqCrController2InformationTrapThe secondary controller in the subsytem has recovered.
Details:
The secondary controller has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.2.0.4 |
cpqCrLogDrvTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.3 |
cpqCrLogDriveInformationTrapA RAIDset has become optimal.
Details:
A RAIDset has become optimal due to a successful completion
of the reconstruction process.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.3.0.5 |
cpqCrLogDriveFailureTrapA RAIDset has failed.
Details:
The RAIDset has failed and is off-line.
User Action:
Possible cause is too many failed disk drives that make up
the RAIDset, the OS can no longer communicate with the RAIDset
for other reasons. TRAP-TYPE .1.3.6.1.4.1.232.141.3.3.0.6 |
cpqCrLogDriveReconstructTrapA RAIDset has started the reconstruction process.
Details:
The RAIDset has started the reconstruction process but is available
for normal use.
Possible causes are an available disk drive was created as
a spare to be inserted into the set, an existing spare was
automatically added to the set for reconstruction upon failure
of a member disk device.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.3.0.7 |
cpqCrLogDriveReducedTrapA RAIDset has become degraded.
Details:
A RAIDset has become degraded due to a member disk device
failure.
User Action:
Replace the failed disk device; add a spare to the system
to cause a reconstruct. TRAP-TYPE .1.3.6.1.4.1.232.141.3.3.0.8 |
cpqCrLogDriveInitializingTrapA RAIDset is initializing.
Details:
A RAIDset is in the process of being intialized.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.3.0.9 |
cpqCrSpareDrvTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.4 |
cpqCrPhyDrvTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.5 |
cpqCrDiskInformationTrapA disk drive has recovered.
Details:
A disk device has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.10 |
cpqCrDiskFailureTrapA disk drive has failed.
Details:
A disk device has failed.
User Action:
Replace the disk device. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.11 |
cpqCrDiskReconstructTrapA disk drive has started the reconstruction process.
Details:
A disk member of a logical drive has begun the reconstruction
process and will be available for use when reconstruction is
complete.
User Action:
Wait for the reconstruction to complete. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.12 |
cpqCrDiskAvailableTrapA disk drive has been made available for use.
Details:
A disk drive has been physically added or set to the
Available state. It can be used as a RAIDset member or as a Spare.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.13 |
cpqCrDiskSpareTrapA disk drive has been made a Spare.
Details:
A disk drive has been set to Spare status from Available and
may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
a member device fail in one of those RAIDsets.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.14 |
cpqCrPhyDiskInformationTrapA disk drive has recovered.
Details:
A disk device has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.30 |
cpqCrPhyDiskFailureTrapA disk drive has failed.
Details:
A disk device has failed.
User Action:
Replace the disk device. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.31 |
cpqCrPhyDiskReconstructTrapA disk drive has started the reconstruction process.
Details:
A disk member of a logical drive has begun the reconstruction
process and will be available for use when reconstruction is
complete.
User Action:
Wait for the reconstruction to complete. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.32 |
cpqCrPhyDiskAvailableTrapA disk drive has been made available for use.
Details:
A disk drive has been physically added or set to the
Available state. It can be used as a RAIDset member or as a Spare.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.33 |
cpqCrPhyDiskSpareTrapA disk drive has been made a Spare.
Details:
A disk drive has been set to Spare status from Available and
may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
a member device fail in one of those RAIDsets.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.5.0.34 |
cpqCrEMUTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.7 |
cpqCrEMUNormalTrapPrimary enclosure state is normal.
Details:
The overall condition of the primary enclosure has returned
to normal.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.15 |
cpqCrEMUFanFailureTrapFan has failed.
Details:
One of the cooling fans in the primary enclosure has
failed.
User Action:
Replace the cooling fan. Possible causes are fan
physically removed, actual hardware failure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.16 |
cpqCrEMUFanInformationTrapThe fan has recovered.
Details:
The cooling fan in the primary enclosure has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.17 |
cpqCrEMUPowerSupplyFailureTrapPower supply has failed.
Details:
One of the power supplies in the primary enclosure has
failed.
User Action:
Replace the power supply. Possible causes are power
supply physically removed, power cord unplugged, actual
hardware failure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.18 |
cpqCrEMUPowerSupplyInformationTrapThe power supply has recovered.
Details:
The power supply in the primary enclosure has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.19 |
cpqCrEMUTemperatureWarningTrapPrimary enclosure temperature warning.
Details:
The temperature in the primary enclosure has triggered a
warning condition detected by the controller.
User Action:
Check the cooling fans in the primary enclosure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.23 |
cpqCrEMUTemperatureCriticalTrapPrimary enclosure temperature critical!.
Details:
The temperature in the primary enclosure has triggered a
critical condition detected by the controller.
User Action:
Check the cooling fans in the primary enclosure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.24 |
cpqCrEMUTemperatureInformationTrapPrimary enclosure temperature normal.
Details:
The temperature in the primary enclosure has
returned to normal.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.7.0.25 |
cpqCrExpCabTrap OBJECT IDENTIFIER .1.3.6.1.4.1.232.141.3.8 |
cpqCrExpCabFanFailureTrapFan has failed in expansion cabinet.
Details:
One of the cooling fans in the expansion cabinet has
failed.
User Action:
Replace the cooling fan. Possible causes are fan
physically removed, actual hardware failure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.20 |
cpqCrExpCabFanInformationTrapFan has recovered.
Details:
A cooling fan in the expansion cabinet has returned to a
normal state.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.21 |
cpqCrExpCabPowerSupplyFailureTrapPower supply has failed.
Details:
One of the power supplies in the expansion cabinet has
failed.
User Action:
Replace the power supply. Possible causes are power
supply physically removed, power cord unplugged, actual
hardware failure. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.22 |
cpqCrExpCabTemperatureWarningTrapExpansion cabinet temperature warning.
Details:
The temperature in the expansion cabinet has triggered a
warning condition detected by the controller.
User Action:
Check the cooling fans in the expansion cabinet. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.26 |
cpqCrExpCabTemperatureCriticalTrapExpansion cabinet temperature critical!
Details:
The temperature in the expansion cabinet has triggered a
critical condition detected by the controller.
User Action:
Check the cooling fans in the expansion cabinet. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.27 |
cpqCrExpCabTemperatureInformationTrapExpansion cabinet temperature normal.
Details:
The temperature in the expansion cabinet has returned to
normal.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.28 |
cpqCrExpCabPowerSupplyInformationTrapThe power supply has recovered.
Details:
The power supply in the expansion cabinet has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.232.141.3.8.0.29 |