CONTIVITY-TRAPS-V1-MIB
The CONTIVITY-TRAPS-V1-MIB module defines SNMP trap notifications and associated binding objects for VPN routers to report critical connectivity events and session state changes. These traps enable network management systems to detect and react to VPN tunnel failures, authentication errors, or link status transitions in real time.
Imported Objects
Objects
143 total| Object Name |
|---|
coldStart TRAP-TYPE .1.3.6.1.2.1.11.0.0 |
linkDown TRAP-TYPE .1.3.6.1.2.1.11.0.2 |
linkUp TRAP-TYPE .1.3.6.1.2.1.11.0.3 |
authenticationFailure TRAP-TYPE .1.3.6.1.2.1.11.0.5 |
contivityTrapsV1 MODULE-IDENTITY .1.3.6.1.4.1.2505.1.0 |
RFC1213-MIB Unknown .1.3.6.1.4.1.2505.1.0 |
powerUpTrapEntry TRAP-TYPE .1.3.6.1.4.1.2505.1.0.401 |
periodicHeartbeatTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.0.601 |
hardwareCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.1 |
hardDisk1StatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1001 |
hardDisk0StatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1002 |
memoryUsageTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1003 |
lanCardStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1004 |
cpuTwoStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1005 |
fanOneStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1006 |
fanTwoStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1007 |
chassisFanStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1008 |
fiveVoltsPosStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1009 |
fiveVoltsMinusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10010 |
threeVoltsPositiveTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10011 |
twoDotFiveVATrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10012 |
twoDotFiveVBTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10013 |
twelveVoltsPositveTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10014 |
twelveVoltsMinsTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10015 |
normalTemperatureTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10016 |
criticalTemperatureTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10017 |
chassisIntrusionTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10018 |
dualPowerSupplyTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10019 |
t1WANStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10020 |
t3WANStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10021 |
hwAccelTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10022 |
v90WANStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10024 |
briWANStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10025 |
serUartStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10026 |
adslWANStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10027 |
hardDisk1Statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.1 |
hardDisk0Statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.2 |
memoryUsagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.3 |
lanCardStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.4 |
cpuTwoStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.5 |
fanOneStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.6 |
fanTwoStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.7 |
chassisFanStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.8 |
fiveVoltsPositivero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.9 |
fiveVoltsMinusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.10 |
threeVoltsPositivero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.11 |
twoDotFiveVAro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.12 |
twoDotFiveVBro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.13 |
twelveVoltsPositivero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.14 |
twelveVoltsMinusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.15 |
normalTemperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.16 |
criticalTemperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.17 |
chassisIntrusionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.18 |
dualPowerSupplyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.19 |
t1WANStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.20 |
t3WANStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.21 |
hwAccelStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.22 |
v90WANStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.24 |
briWANStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.25 |
serUartStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.26 |
adslWANStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.27 |
serverCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.2 |
radiusAcctServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3001 |
backupServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3002 |
diskRedundencyTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3003 |
intLDAPServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3004 |
loadBalancingServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3005 |
dnsServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3006 |
snmpServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3007 |
ipAddressPoolTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3008 |
extLDAPServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3009 |
radiusAuthServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30010 |
certificateServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30011 |
extLDAPAuthServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30012 |
cmpServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30013 |
dhcpServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30014 |
crlServerTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30015 |
radiusAcctServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.1 |
backupServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.2 |
diskRedundencyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.3 |
intLDAPServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.4 |
loadBalancingServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.5 |
dnsServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.6 |
snmpServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.7 |
ipAddressPoolro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.8 |
extLDAPServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.9 |
radiusAuthServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.10 |
certificateServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.11 |
extLDAPAuthServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.12 |
cmpServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.13 |
dhcpServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.14 |
crlServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.15 |
serviceCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.3 |
netBuffersTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5001 |
fireWallTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5002 |
fipsStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5003 |
licensingStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5004 |
natStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5005 |
antiSpoofingStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5006 |
sslVpnStatusTrap TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5007 |
CONTIVITY-TRAPS-V1-MIB Technical Reference Overview
The CONTIVITY-TRAPS-V1-MIB SNMP MIB module published by Newoak defines 143 managed OID objects, including 76 scalar/column metrics, 0 SNMP tables, and 57 trap/notification events anchored at base OID .1.3.6.1.4.1.2505.1.0. Monitored SNMP traps/notifications include hardDisk1StatusTrap, hardDisk0StatusTrap, memoryUsageTrap, lanCardStatusTrap, cpuTwoStatusTrap, fanOneStatusTrap.
Key OID Definitions in CONTIVITY-TRAPS-V1-MIB
.1.3.6.1.4.1.2505.1.0This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
.1.3.6.1.4.1.2505.1.1.0.1001Hard Disk Number 1 Status
.1.3.6.1.4.1.2505.1.1.0.1002Hard Disk Number 0 Status
.1.3.6.1.4.1.2505.1.1.0.1003Memory Usage Status
.1.3.6.1.4.1.2505.1.1.0.1004Status of any LAN cards on the system
.1.3.6.1.4.1.2505.1.1.0.1005Status of second CPU.
.1.3.6.1.4.1.2505.1.1.0.1006Status of the first CPU fan
.1.3.6.1.4.1.2505.1.1.0.1007Status of the second CPU fan
.1.3.6.1.4.1.2505.1.1.0.1008Status of the chassis fan.
.1.3.6.1.4.1.2505.1.1.0.1009Status of the +5 Volt power
.1.3.6.1.4.1.2505.1.1.0.10010Status of -5 Volt power
.1.3.6.1.4.1.2505.1.1.0.10011Status of +3 Volt power
.1.3.6.1.4.1.2505.1.1.0.10012Status of 2.5VA power
.1.3.6.1.4.1.2505.1.1.0.10013Status of 2.5VB power
.1.3.6.1.4.1.2505.1.1.0.10014Status of +12 Volt power
.1.3.6.1.4.1.2505.1.1.0.10015Status of -12 Volt power
.1.3.6.1.4.1.2505.1.1.0.10016Status of the normal temperature reading
.1.3.6.1.4.1.2505.1.1.0.10017Status of the critical temperature reading
.1.3.6.1.4.1.2505.1.1.0.10018The chassis intrusion sensor indicates that the unit has been physically opened
.1.3.6.1.4.1.2505.1.1.0.10019Status of the redundant power supplies
.1.3.6.1.4.1.2505.1.1.0.10020Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized
.1.3.6.1.4.1.2505.1.1.0.10021Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing
.1.3.6.1.4.1.2505.1.1.0.10022Status of hardware accelerator card. Possible Values: Invalid hardware accelerator unit %d; Unknown hardware accelerator unit %d; Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED; Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED; Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE; Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING; Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN; Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;
.1.3.6.1.4.1.2505.1.1.0.10024Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntModem-X disabled Healthy: Device IntModem-X: PPP is UP. Alert: Device IntModem-X down Warning: Device IntModem-X not initialized Alert: Device IntModem-X: Call is UP. Internal Error. Warning: Device IntModem-X is Down. Last dial-out attempt FAILED. Healthy: Device IntModem-X is Down (No Active calls) Warning: Device IntModem-X is in an UNKNOWN state
More MIBs from Newoak
Browse all NewoakMIBs →Standard SNMP MIB module defining data structures for DAP-3520-v115.
The CONTIVITY-ID-V1-MIB module provides management access to session state and connection metrics on Contivity VPN routers, enabling the monitoring of active user sessions, tunnel status, and authentication states. This module facilitates the tracking of critical VPN throughput and connectivity health indicators specific to the Check Point Contivity appliance family.
The NEWOAK-MIB module identifies specific Cisco VPN Router hardware variants by assigning unique sysObjectID values to distinct device models, enabling SNMP management systems to accurately distinguish between different router revisions for targeted monitoring and configuration.
The CONTIVITY-INFO-V1-MIB module provides management access to connectivity status and session metrics on Contivity VPN routers, specifically monitoring IPsec tunnel states, user authentication sessions, and interface link availability.
The CONTIVITY-TRAP-ACKNOWLEDGMENT-MIB defines the management objects required for Nortel Contivity Security Systems to acknowledge receipt of SNMP trap notifications, ensuring reliable delivery confirmation for critical security events such as session terminations, authentication failures, and intrusion detection alerts. This module facilitates the implementation of a reliable trap acknowledgment protocol, preventing the loss of audit trails and security state changes in high-availability firewall environments.