Home/Catalog/CONTIVITY-TRAPS-V1-MIB

CONTIVITY-TRAPS-V1-MIB

AI MIB Summary

The CONTIVITY-TRAPS-V1-MIB module defines SNMP trap notifications and associated binding objects for VPN routers to report critical connectivity events and session state changes. These traps enable network management systems to detect and react to VPN tunnel failures, authentication errors, or link status transitions in real time.

This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
Main OID:
contivityTrapsV1.1.3.6.1.4.1.2505.1.0
143
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

143 total
Object Name
coldStart
TRAP-TYPE
.1.3.6.1.2.1.11.0.0
linkDown
TRAP-TYPE
.1.3.6.1.2.1.11.0.2
linkUp
TRAP-TYPE
.1.3.6.1.2.1.11.0.3
authenticationFailure
TRAP-TYPE
.1.3.6.1.2.1.11.0.5
contivityTrapsV1
MODULE-IDENTITY
.1.3.6.1.4.1.2505.1.0
RFC1213-MIB
Unknown
.1.3.6.1.4.1.2505.1.0
powerUpTrapEntry
TRAP-TYPE
.1.3.6.1.4.1.2505.1.0.401
periodicHeartbeatTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.0.601
hardwareCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.1
hardDisk1StatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1001
hardDisk0StatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1002
memoryUsageTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1003
lanCardStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1004
cpuTwoStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1005
fanOneStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1006
fanTwoStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1007
chassisFanStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1008
fiveVoltsPosStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1009
fiveVoltsMinusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10010
threeVoltsPositiveTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10011
twoDotFiveVATrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10012
twoDotFiveVBTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10013
twelveVoltsPositveTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10014
twelveVoltsMinsTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10015
normalTemperatureTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10016
criticalTemperatureTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10017
chassisIntrusionTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10018
dualPowerSupplyTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10019
t1WANStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10020
t3WANStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10021
hwAccelTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10022
v90WANStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10024
briWANStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10025
serUartStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10026
adslWANStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10027
hardDisk1Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.1
hardDisk0Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.2
memoryUsagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.3
lanCardStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.4
cpuTwoStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.5
fanOneStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.6
fanTwoStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.7
chassisFanStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.8
fiveVoltsPositivero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.9
fiveVoltsMinusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.10
threeVoltsPositivero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.11
twoDotFiveVAro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.12
twoDotFiveVBro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.13
twelveVoltsPositivero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.14
twelveVoltsMinusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.15
normalTemperaturero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.16
criticalTemperaturero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.17
chassisIntrusionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.18
dualPowerSupplyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.19
t1WANStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.20
t3WANStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.21
hwAccelStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.22
v90WANStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.24
briWANStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.25
serUartStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.26
adslWANStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.27
serverCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.2
radiusAcctServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3001
backupServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3002
diskRedundencyTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3003
intLDAPServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3004
loadBalancingServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3005
dnsServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3006
snmpServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3007
ipAddressPoolTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3008
extLDAPServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3009
radiusAuthServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30010
certificateServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30011
extLDAPAuthServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30012
cmpServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30013
dhcpServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30014
crlServerTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30015
radiusAcctServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.1
backupServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.2
diskRedundencyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.3
intLDAPServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.4
loadBalancingServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.5
dnsServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.6
snmpServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.7
ipAddressPoolro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.8
extLDAPServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.9
radiusAuthServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.10
certificateServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.11
extLDAPAuthServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.12
cmpServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.13
dhcpServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.14
crlServerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.15
serviceCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.3
netBuffersTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5001
fireWallTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5002
fipsStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5003
licensingStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5004
natStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5005
antiSpoofingStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5006
sslVpnStatusTrap
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5007
Showing 100 of 143 OID objects

CONTIVITY-TRAPS-V1-MIB Technical Reference Overview

The CONTIVITY-TRAPS-V1-MIB SNMP MIB module published by Newoak defines 143 managed OID objects, including 76 scalar/column metrics, 0 SNMP tables, and 57 trap/notification events anchored at base OID .1.3.6.1.4.1.2505.1.0. Monitored SNMP traps/notifications include hardDisk1StatusTrap, hardDisk0StatusTrap, memoryUsageTrap, lanCardStatusTrap, cpuTwoStatusTrap, fanOneStatusTrap.

Key OID Definitions in CONTIVITY-TRAPS-V1-MIB

contivityTrapsV1MODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.2505.1.0

This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.

hardDisk1StatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1001

Hard Disk Number 1 Status

hardDisk0StatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1002

Hard Disk Number 0 Status

memoryUsageTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1003

Memory Usage Status

lanCardStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1004

Status of any LAN cards on the system

cpuTwoStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1005

Status of second CPU.

fanOneStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1006

Status of the first CPU fan

fanTwoStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1007

Status of the second CPU fan

chassisFanStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1008

Status of the chassis fan.

fiveVoltsPosStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.1009

Status of the +5 Volt power

fiveVoltsMinusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10010

Status of -5 Volt power

threeVoltsPositiveTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10011

Status of +3 Volt power

twoDotFiveVATrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10012

Status of 2.5VA power

twoDotFiveVBTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10013

Status of 2.5VB power

twelveVoltsPositveTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10014

Status of +12 Volt power

twelveVoltsMinsTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10015

Status of -12 Volt power

normalTemperatureTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10016

Status of the normal temperature reading

criticalTemperatureTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10017

Status of the critical temperature reading

chassisIntrusionTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10018

The chassis intrusion sensor indicates that the unit has been physically opened

dualPowerSupplyTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10019

Status of the redundant power supplies

t1WANStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10020

Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized

t3WANStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10021

Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing

hwAccelTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10022

Status of hardware accelerator card. Possible Values: Invalid hardware accelerator unit %d; Unknown hardware accelerator unit %d; Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED; Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED; Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE; Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING; Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN; Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;

v90WANStatusTrapTRAP-TYPEnot-accessible
.1.3.6.1.4.1.2505.1.1.0.10024

Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntModem-X disabled Healthy: Device IntModem-X: PPP is UP. Alert: Device IntModem-X down Warning: Device IntModem-X not initialized Alert: Device IntModem-X: Call is UP. Internal Error. Warning: Device IntModem-X is Down. Last dial-out attempt FAILED. Healthy: Device IntModem-X is Down (No Active calls) Warning: Device IntModem-X is in an UNKNOWN state

More MIBs from Newoak

Browse all NewoakMIBs →
DAP-3520-v115

Standard SNMP MIB module defining data structures for DAP-3520-v115.

598 objects→
CONTIVITY-ID-V1-MIB

The CONTIVITY-ID-V1-MIB module provides management access to session state and connection metrics on Contivity VPN routers, enabling the monitoring of active user sessions, tunnel status, and authentication states. This module facilitates the tracking of critical VPN throughput and connectivity health indicators specific to the Check Point Contivity appliance family.

23 objects→
NEWOAK-MIB

The NEWOAK-MIB module identifies specific Cisco VPN Router hardware variants by assigning unique sysObjectID values to distinct device models, enabling SNMP management systems to accurately distinguish between different router revisions for targeted monitoring and configuration.

20 objects→
CONTIVITY-INFO-V1-MIB

The CONTIVITY-INFO-V1-MIB module provides management access to connectivity status and session metrics on Contivity VPN routers, specifically monitoring IPsec tunnel states, user authentication sessions, and interface link availability.

15 objects→
CONTIVITY-TRAP-ACKNOWLEDGMENT-MIB

The CONTIVITY-TRAP-ACKNOWLEDGMENT-MIB defines the management objects required for Nortel Contivity Security Systems to acknowledge receipt of SNMP trap notifications, ensuring reliable delivery confirmation for critical security events such as session terminations, authentication failures, and intrusion detection alerts. This module facilitates the implementation of a reliable trap acknowledgment protocol, preventing the loss of audit trails and security state changes in high-availability firewall environments.

13 objects→