The CONTIVITY-TRAPS-V1-MIB module defines SNMP trap notifications and associated binding objects for VPN routers to report critical connectivity events and session state changes. These traps enable network management systems to detect and react to VPN tunnel failures, authentication errors, or link status transitions in real time.

This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
Main OID:
contivityTrapsV1.1.3.6.1.4.1.2505.1.0
143
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

143 total
Object Name
coldStartA coldStart trap signifies that the SNMPv2 entity, acting in an agent role, is reinitializing itself and that its configuration may have been altered.
TRAP-TYPE
.1.3.6.1.2.1.11.0.0
linkDownA linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration. Varbind list: ifIndex ifAdminStatus ifOperStatus ifDescr ifType ifReasonForStatus-ces ifPhysLocation-ces ifPhysRelPos-ces ifIpAddr-ces ifName-ces ifTunnelRemoteIpAddr-ces sysObjectID sysName
TRAP-TYPE
.1.3.6.1.2.1.11.0.2
linkUpA linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up. Varbind list: ifIndex ifAdminStatus ifOperStatus ifDescr ifType ifReasonForStatus-ces ifPhysLocation-ces ifPhysRelPos-ces ifIpAddr-ces ifName-ces ifTunnelRemoteIpAddr-ces sysObjectID sysName
TRAP-TYPE
.1.3.6.1.2.1.11.0.3
authenticationFailureAn authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. The snmpEnableAuthenTraps object indicates whether this trap will be generated. snmpAuthenOperation-ces identifies the operation( ie. GetRequest, GetNextRequest,... ) was being attempted. snmpAuthenIpAddress-ces identifies the source IP address of the operation. snmpAuthenCommString-ces identifies the community string that was used in the operation.
TRAP-TYPE
.1.3.6.1.2.1.11.0.5
contivityTrapsV1This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
MODULE-IDENTITY
.1.3.6.1.4.1.2505.1.0
RFC1213-MIBThis MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
Unknown
.1.3.6.1.4.1.2505.1.0
powerUpTrapEntryPower Up
TRAP-TYPE
.1.3.6.1.4.1.2505.1.0.401
periodicHeartbeatTrapPeriodic Heartbeat
TRAP-TYPE
.1.3.6.1.4.1.2505.1.0.601
hardwareCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.1
hardDisk1StatusTrapHard Disk Number 1 Status
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1001
hardDisk0StatusTrapHard Disk Number 0 Status
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1002
memoryUsageTrapMemory Usage Status
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1003
lanCardStatusTrapStatus of any LAN cards on the system
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1004
cpuTwoStatusTrapStatus of second CPU.
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1005
fanOneStatusTrapStatus of the first CPU fan
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1006
fanTwoStatusTrapStatus of the second CPU fan
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1007
chassisFanStatusTrapStatus of the chassis fan.
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1008
fiveVoltsPosStatusTrapStatus of the +5 Volt power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.1009
fiveVoltsMinusTrapStatus of -5 Volt power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10010
threeVoltsPositiveTrapStatus of +3 Volt power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10011
twoDotFiveVATrapStatus of 2.5VA power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10012
twoDotFiveVBTrapStatus of 2.5VB power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10013
twelveVoltsPositveTrapStatus of +12 Volt power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10014
twelveVoltsMinsTrapStatus of -12 Volt power
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10015
normalTemperatureTrapStatus of the normal temperature reading
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10016
criticalTemperatureTrapStatus of the critical temperature reading
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10017
chassisIntrusionTrapThe chassis intrusion sensor indicates that the unit has been physically opened
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10018
dualPowerSupplyTrapStatus of the redundant power supplies
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10019
t1WANStatusTrapStatus of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initialized
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10020
t3WANStatusTrapStatus of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializing
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10021
hwAccelTrapStatus of hardware accelerator card. Possible Values: Invalid hardware accelerator unit %d; Unknown hardware accelerator unit %d; Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED; Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED; Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE; Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING; Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN; Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10022
v90WANStatusTrapStatus of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntModem-X disabled Healthy: Device IntModem-X: PPP is UP. Alert: Device IntModem-X down Warning: Device IntModem-X not initialized Alert: Device IntModem-X: Call is UP. Internal Error. Warning: Device IntModem-X is Down. Last dial-out attempt FAILED. Healthy: Device IntModem-X is Down (No Active calls) Warning: Device IntModem-X is in an UNKNOWN state
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10024
briWANStatusTrapStatus of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Invalid index X Alert: Device BRI-X not Responding. Needs Host Reboot. Disabled: Device BRI-X disabled Alert: Device BRI-X down Warning: Device BRI-X not initialized Healthy: Device BRI-X: PPP is UP. Alert: Device BRI-X: Call is UP. Internal Error. Warning: Device BRI-X is Down. Last dial-out attempt FAILED. Healthy: Device BRI-X is Down (No Active calls) Alert: Device BRI-X is in an UNKNOWN state
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10025
serUartStatusTrapStatus of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index X Healthy: Device COMX is set for Serial Menu. Disabled: Device COMX disabled Warning: Device COMX not initialized Healthy: Device COMX: PPP is UP. Alert: Device COMX: Call is UP. Internal Error. Warning: Device COMX is Down. Last dial-out attempt FAILED. Healthy: Device COMX is Down (No Active calls) Alert: Device COMX is in an UNKNOWN state
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10026
adslWANStatusTrapStatus of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid index X Alert: Device ADIADSLX off line Disabled: Device ADIADSLX disabled Alert: Device ADIADSLX down Warning: Device ADIADSLX not initialized Healthy: Device ADIADSLX up
TRAP-TYPE
.1.3.6.1.4.1.2505.1.1.0.10027
hardDisk1StatusHard Disk Number 1 Status. Possible Values: Warning: Hard Disk 1 : Device /ide1/ not available Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/ Alert: Hard Disk 1 : Utilization exceeds 87.5%% on /ide1/ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.1
hardDisk0StatusHard Disk Number 0 Status. Possible Values: Warning: Hard Disk 0 : Device /ide0/ not available Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/ Alert: Hard Disk 0 : Utilization exceeds 87.5%% on /ide0/ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.2
memoryUsageMemory Usage Status. Possible Values: Warning: Memory Usage : Utilization exceeds 75% Alert: Memory Usage : Utilization exceeds 87.5%ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.3
lanCardStatusStatus of any LAN cards on the system. Possible Values: Please note that X corresponds to the Xth slot in the system. Please note that Y corresponds to the relative position of the port on the card in the Xth slot in the system. Warning: LAN on Slot X Interface Y: Device feiX has no IP address; Warning: LAN on Slot X Interface Y: Device feiX disabled; Alert: LAN on Slot X Interface Y: Device feiX down; Alert: LAN on Slot X Interface Y: Device feiX Invalid Device X The Alert status above indicates that the interface has no link when it should. Possible causes are improper connection speeds and duplex, improper cabling or a configuration issue.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.4
cpuTwoStatusStatus of second CPU. Possible Values: Alert: CPU 2: Program load failed; Alert: CPU 2: Bootup did not complete; Alert: CPU 2: Communication lost; Alert: CPU 2: Failed. Reason unknown; Each of these indicates that the application CPU is not functioning correctly. The system will continue to function without the application processor. This can only be sent from a system with multiple CPUs. See the Admin Guide for a list of systems that contain multiple CPUs. The CES will emit an audible alarm and the networking performance will be degraded. A Nortel support representative should be contacted if rese ing the CES does not correct the problem. The effect is the same in each case. The system will be running with only one CPU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.5
fanOneStatusStatus of the first CPU fan. Possible Values: Alert: CPU One Fan: Fan not functioning; This indicates that the fan on the primary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the primary CPU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.6
fanTwoStatusStatus of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the auxiliary CPU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.7
chassisFanStatusStatus of the chassis fan. Possible Values: Alert: Chassis Fan: Fan not functioning; Alert: Chassis Fan 2: Fan not functioning; This indicates that one of the chassis fans is running either below the specified range of speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. If either of the fans are not working properly, the box must be looked at by a service technician as soon as possible. Not doing so will result in overheating of the system, improper system operation, and possible component failure.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.8
fiveVoltsPositiveStatus of +5 Volt power. Possible Values: Alert: Voltage 5 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.9
fiveVoltsMinusStatus of -5 Volt power. Possible Values: Alert: Voltage 5 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.10
threeVoltsPositiveStatus of +3 Volt power. Possible Values: Alert: Voltage 3.3 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.11
twoDotFiveVAStatus of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range; This is the voltage supplied to the primary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.12
twoDotFiveVBStatus of 2.5VB power. Possible Values: Alert: Voltage 2.5 VB: Voltage out of range; This is the voltage supplied to the seconary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.13
twelveVoltsPositiveStatus of +12 Volt power. Possible Values: Alert: Voltage 12 V Plus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.14
twelveVoltsMinusStatus of -12 Volt power. Possible Values: Alert: Voltage 12 V Minus: Voltage out of range; The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.15
normalTemperatureStatus of normal temperature reading. Possible Values: Alert: Normal Temperature: Normal temperature out of range; This indicates that the box is running above its rated normal operating temperature. This may be the result of an improperly working fan or a high ambient temperature. The box is not guaranteed to run properly while running above the normal operating temperature range. Performance will be degraded. Not taking action to correct this situation can result in component failure. Do not rely on waiting for the criticalTemperatureTrap as that is only supported by certain platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.16
criticalTemperatureStatus of critical temperature reading. Possible Values: Alert: Critical Temperature: Critial temperature out of range; This indicates that the box is running at a critically high temperature above the normal operating range. This is only supported on certain platforms. See the Admin Guide for a list of platforms which support this. The box must be shut down immediately. Component failure may already have occurred. If the reason for such a high operating temperature cannot be determined, contact a qualified Nortel representative.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.17
chassisIntrusionThe chassis intrusion sensor indicates that the unit has been opened. Possible Values: Alert: Intrusion: Box has been opened; The cover to the CES has been opened or is in the process of being opened. This indicates a possible physical security intrusion. The system will continue to operate while the box is opened. Check to insure that no unauthorized persons have opened the unit.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.18
dualPowerSupplyStatus of the redundant power supplies. Possible Values: Alert: Dual Power Supply: Redundant supply faulted This indicates that, on systems with redundant power supplies, one of the power supplies is not working. This trap can only be sent from systems which have redundant power supplies. The system will continue to run with only one power supply working. A new power supply must be obtained via an authorized Nortel representative as quickly as possible. This will help reduce the risk window of system failure in the event that the working power supply ceases to function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.19
t1WANStatusStatus of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device WanicX down Warning: Device WanicX not initialized Warning: Device WanicX PPP negotiating Alert: Device WanicX PPP down Alert: Device WanicX FR no support Alert: Device WanicX Unknown DL For T1: Alert: Invalid Device X Warning: Device LMCDTEX disabled Alert: Device LMCDTEX down Warning: Device LMCDTEX not initialized For CSU/DSU: Alert: Invalid Device X Warning: Device LMCCDX disabled Alert: Device LMCCDX down Warning: Device LMCCDX not initializedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.20
t3WANStatusStatus of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Device HSSIX not initialized Alert: Device HSSIX PPP down Warning: Device HSSIX PP initializingro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.21
hwAccelStatusStatus of hardware accelerator card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.22
v90WANStatusStatus of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid index X Disabled: Device IntModem-X disabled Healthy: Device IntModem-X: PPP is UP. Alert: Device IntModem-X down Warning: Device IntModem-X not initialized Alert: Device IntModem-X: Call is UP. Internal Error. Warning: Device IntModem-X is Down. Last dial-out attempt FAILED. Healthy: Device IntModem-X is Down (No Active calls) Warning: Device IntModem-X is in an UNKNOWN statero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.24
briWANStatusStatus of ISDN BRI Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Invalid index X Alert: Device BRI-X not Responding. Needs Host Reboot. Disabled: Device BRI-X disabled Alert: Device BRI-X down Warning: Device BRI-X not initialized Healthy: Device BRI-X: PPP is UP. Alert: Device BRI-X: Call is UP. Internal Error. Warning: Device BRI-X is Down. Last dial-out attempt FAILED. Healthy: Device BRI-X is Down (No Active calls) Alert: Device BRI-X is in an UNKNOWN statero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.25
serUartStatusStatus of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index X Healthy: Device COMX is set for Serial Menu. Disabled: Device COMX disabled Warning: Device COMX not initialized Healthy: Device COMX: PPP is UP. Alert: Device COMX: Call is UP. Internal Error. Warning: Device COMX is Down. Last dial-out attempt FAILED. Healthy: Device COMX is Down (No Active calls) Alert: Device COMX is in an UNKNOWN statero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.26
adslWANStatusStatus of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid index X Alert: Device ADIADSLX off line Disabled: Device ADIADSLX disabled Alert: Device ADIADSLX down Warning: Device ADIADSLX not initialized Healthy: Device ADIADSLX upro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.1.27
serverCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.2
radiusAcctServerTrapStatus of External Radius Accounting Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3001
backupServerTrapStatus of External Disk Backup Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3002
diskRedundencyTrapStatus of Local Disk Redundency
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3003
intLDAPServerTrapStatus of Internal LDAP Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3004
loadBalancingServerTrapStatus of Load Balancing Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3005
dnsServerTrapStatus of DNS Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3006
snmpServerTrapStatus of SNMP Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3007
ipAddressPoolTrapStatus of the IP address pool
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3008
extLDAPServerTrapStatus of External LDAP Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.3009
radiusAuthServerTrapStatus of Radius Authentication Server
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30010
certificateServerTrapStatus of Certificates Validity Possible Values: Healthy: Certificates Validity: Operational; Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: One/more certificate is invalid; Disabled: Certificates Validity: No certificate defined;
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30011
extLDAPAuthServerTrapStatus of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable); Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30012
cmpServerTrapStatus of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: there is at least one request in processing; No Certificate Requests submitted: there is no request sent;
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30013
dhcpServerTrapStatus of DHCP Server Possible Values: Disabled: DHCP Server is Disabled Alert: DHCP Server is NOT configured Alert: DHCP Server is configured and operational, Using backup config Alert: No IP Address available for subnet Alert: DHCP Server is configured and server is DOWN Healthy: DHCP Server is Operational Warning: Subnet low on IP Addresses Warning: DHCP Server Initializing Warning: DHCP Server is Enabled, but status Unknown cannot be determined
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30014
crlServerTrapStatus of CRL Server.
TRAP-TYPE
.1.3.6.1.4.1.2505.1.2.0.30015
radiusAcctServerStatus of External Radius Accounting Server. Possible Values: Warning: RADIUS Accounting Server: Server not configured Alert: RADIUS Accounting Server: Error Alert: RADIUS Accounting Server: Not Configuredro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.1
backupServerStatus of External Disk Backup Server. Possible Values: Warning: Auto Backup Servers: Server not configured. Warning: Auto Backup Servers: Can't backup to xxx yyy zzz Alert: Auto Backup Servers: Can't backup to xxx yyy zzz Can't backup to xxx yyy zzz is issued as an alert when none of the servers can be reached.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.2
diskRedundencyStatus of Local Disk Redundency. Possible Values: Alert: Disk Redundancy: Not Configured Alert: Disk Redundancy: Errorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.3
intLDAPServerStatus of Internal LDAP Server. Possible Values: Warning : Internal LDAP Server : Restore in progress Alert : Internal LDAP Server : Server is downro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.4
loadBalancingServerStatus of Load Balancing Server. Possible Values: Disabled: Load Balancing Service: Server not enabled; Warning: Load Balancing Service: Timed out waiting for response from server;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.5
dnsServerStatus of DNS Server. Possible Values: Warning: DNS Servers : Error Warning: DNS Servers : Operational Alert: DNS Servers : Configured Alert: DNS Servers : Error The values have the following meaning: Warning: DNS Servers : Error Warning: DNS Servers : Operational Alert: DNS Servers : Configured Alert: DNS Servers : Errorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.6
snmpServerStatus of SNMP Server. Possible Values: Warning: SNMP Servers : Error Warning: SNMP Servers : Can't reach xxx.xxx.xxx.xxx or yyy.yyy.yyy.yyy Alert: SNMP Servers : Error The values have the following meaning: Warning: SNMP Servers : Error Alert: SNMP Servers : Errorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.7
ipAddressPoolStatus of the IP address pool. Possible Values: Warning: IP Address Pool : Reserved address count is low. Warning: IP Address Pool : DHCP server(s) unavailable Alert: IP Address Pool : Server is down Alert: IP Address Pool : Not Configured Alert: IP Address Pool : No IP address available. Alert: IP Address Pool : Reserved address count is low. Alert: IP Address Pool : Associated system task failed. Alert: IP Address Pool : Server not configured Alert: IP Address Pool : Error The values have the following meaning: Warning: IP Address Pool : Reserved address count is low. Alert: IP Address Pool : Server is down Alert: IP Address Pool : Not Configured Alert: IP Address Pool : No IP address available. Alert: IP Address Pool : Associated system task failed. Alert: IP Address Pool : Server not configured Alert: IP Address Pool : Errorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.8
extLDAPServerStatus of External LDAP Server. Possible Values: Warning: External LDAP Servers : Server is down Alert: External LDAP Servers : Server is down The values have the following meaning: Warning: External LDAP Servers : Server is down Alert: External LDAP Servers : Server is downro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.9
radiusAuthServerStatus of Radius Authentication Server. Possible Values: Warning: RADIUS Authentication Servers : Error Alert: RADIUS Authentication Servers : Error The values have the following meaning: Warning: RADIUS Authentication Servers : Error Alert: RADIUS Authentication Servers : Errorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.10
certificateServerStatus of Certificates Validity. Possible Values: Alert: Certificates Validity: All certificates are going to expire/expired; Warning: Certificates Validity: One/more certificate is invalid; Disabled: Certificates Validity: No certificate defined;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.11
extLDAPAuthServerStatus of External LDAP Authentication Server. Possible Values: Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable); Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.12
cmpServerStatus of CMP Server. Possible Values: One/more Certificate Requests error: there is at least one request error; One/more Certificate Requests processing: there is at least one request in processing; No Certificate Requests submitted: there is no request sent;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.13
dhcpServerStatus of DHCP Server. Possible Values: Disabled: DHCP Server is Disabled Alert: DHCP Server is NOT configured Alert: DHCP Server is configured and operational, Using backup config Alert: No IP Address available for subnet Alert: DHCP Server is configured and server is DOWN Healthy: DHCP Server is Operational Warning: Subnet low on IP Addresses Warning: DHCP Server Initializing Warning: DHCP Server is Enabled, but status Unknown cannot be determinedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.14
crlServerStatus of CRL Server.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.2.15
serviceCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.3
netBuffersTrapNetwork buffer usage
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5001
fireWallTrapStatus of internal firewall
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5002
fipsStatusTrapStatus of FIPS
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5003
licensingStatusTrapStatus temporary SW Licenses
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5004
natStatusTrapStatus of Network Address Translator
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5005
antiSpoofingStatusTrapStatus of Anti Spoofing Feature
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5006
sslVpnStatusTrapStatus of SSL-VPN Accelerator
TRAP-TYPE
.1.3.6.1.4.1.2505.1.3.0.5007
netBuffersNetwork buffer usage. Possible Values: Warning: Buffer Usage : Utilization exceeds 75% Alert: Buffer Usage : Utilization exceeds 87.5%ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.1
fireWallStatus of internal firewall. Possible Values: Disabled: Firewall: Firewall disabled; Disabled: Firewall: Firewall stopped; Warning: Firewall: Current Firewall is %s. Reboot is required to start %s; Warning: Firewall: Firewall state is not known!; Warning: Firewall: Daemon loading policy; Alert: Firewall: Firewall requires reboot to start; Alert: Firewall: Daemon task does not exist; Alert: Firewall: Daemon task is suspended; The values have the following meaning: Disabled: Firewall: Firewall disabled; Warning: Firewall: Current Firewall is %s. Reboot is required to start %s; Warning: Firewall: Firewall state is not known!; Disabled: Firewall: Firewall stopped; Warning: Firewall: Daemon loading policy; Alert: Firewall: Firewall requires reboot to start; Alert: Firewall: Daemon task does not exist; Alert: Firewall: Daemon task is suspended;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.2
fipsStatusStatus of FIPS. Possible Values: Warning: FIPS: Random generator test failed; Warning: FIPS: DESMAC check on executables Failed; Warning: FIPS: DES KAT Test Failed; Warning: FIPS: SHA1 Self Test Failed; Alert: FIPS: status not known;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.3
licensingStatusStatus of temporary SW Licenses. Possible Values: Warning: Licensing: Temporary key will expire within 5 days; Alert: Licensing: Temporary key has expired;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.4
natStatusStatus of Network Address Translator. Possible Values: Disabled: NAT: NAT disabled; Warning: NAT: Reboot is required to start Interface NAT; Warning: NAT: NAT state is not known!; Alert: NAT: All Addresses in the Address Translation pool are used; Alert: NAT: LDAP policy parse failed - Using system default policy; The values have the following meaning: Disabled: NAT: NAT disabled; Existing NAT sessions are not deleted, but Warning: NAT: Reboot is required to start Interface NAT;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.5
antiSpoofingStatusStatus of Anti Spoofing Feature. Possible Values: Disabled: Anti-Spoofing is Disabled; Warning: Anti-Spoofing : Packets Dropped; Alert: Anti-Spoofing state not known!; The values have the following meaning:ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.6
sslVpnStatusStatus of SSL-VPN Accelerator. Possible Values: Disabled: Disabled Disabled: HW not installed Warning: Initialization in progress. Warning: Configuration Errors - see eventlog for details. Healthy: Operational Alert: Unreachable: Error Comminicating with SSL-VPNro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.3.7
loginCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.4
failedLoginTrapFailed Login Attempt
TRAP-TYPE
.1.3.6.1.4.1.2505.1.4.0.101
failedLoginFailed Login Attempt. Possible Values: Failed Login Attempt: Username=IPSEC Encrypted: Date/Time=(xx) ; Failed Login Attempt: Username=(userid): Date/Time=(xx) ; Failed Login Attempt. Invalid Account: Username=(userid): Date/Time=(xx) ; Failed Remote Network Login: Username=(userid): Date/Time=(xx) ; Failed Remote Application Login: Username=(userid): Date/Time=(xx) ; The values have the following meaning:ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.4.1
intrusionCESTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.5
securityIntrusionTrapSecurity Intrusion
TRAP-TYPE
.1.3.6.1.4.1.2505.1.5.0.201
securityIntrusionSecurity Intrusion. Possible Values: Intruder: : Source: %s, Destination: %s;ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.5.1
powerUpTrapPower Up. Possible Values: Cold Startrodeprecated
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.6
severityLevelSeverity of specific trap.ro
Unknown
.1.3.6.1.4.1.2505.1.7
systemNameSystem Name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.8
systemDateSystem Date.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.9
systemTimeSystem Time.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.10
systemUpTimeSystem Up Time.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.11
periodicHeartbeatPeriodic Heartbeat. Possible Values: Has been executed n timesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.12
snmpAgentTrapInfo-ces
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.14
snmpAgentAuthTrapInfo-ces
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.14.1
snmpAuthenOperation-cesSNMP operation attempted.ro
Enumeration
.1.3.6.1.4.1.2505.1.14.1.1
snmpAuthenIpAddress-cesIP address of host trying to access the CES.ro
IpAddress
.1.3.6.1.4.1.2505.1.14.1.2
snmpAuthenCommString-cesCommunity string used to access the CES.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.14.1.3
snmpAgentInterfaceInfo-ces
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.14.2
ifReasonForStatus-cesThe reason for the status change. These include: unknown(1) timed-out(2)ro
IfReasonForStatus-ces
.1.3.6.1.4.1.2505.1.14.2.1
ifPhysLocation-cesThe physical location of the port. This has the values of motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5.ro
PortLocation-ces
.1.3.6.1.4.1.2505.1.14.2.2
ifPhysRelPos-cesThe relative position of the physical port at the location defined by interfacePhysLocation.ro
INTEGER
.1.3.6.1.4.1.2505.1.14.2.3
ifIpAddr-cesFor physical ports this is the associated IP address. For a tunnel connection it is the local IP address.ro
IpAddress
.1.3.6.1.4.1.2505.1.14.2.4
ifName-cesThe name of the interface, same as ifName.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2505.1.14.2.5
ifTunnelRemoteIpAddr-cesThe remote IP address of a tunnel connection.ro
IpAddress
.1.3.6.1.4.1.2505.1.14.2.6
snmpAgentFirewallInfo-ces
OBJECT IDENTIFIER
.1.3.6.1.4.1.2505.1.14.3
firewallRuleTriggeredTrapAn event sent at the user's request to signal that a rule has been matched. firewallPolicyType-ces firewallRuleType-ces firewallRuleNumber-ces ifIndex ifName-ces firewallSrcAddr-ces firewallSrcPort-ces firewallDestAddr-ces firewallDestPort-ces firewallProtocolID-ces firewallRuleAction-ces
TRAP-TYPE
.1.3.6.1.4.1.2505.1.14.3.0.1
firewallPolicyType-cesPolicy type.ro
FirewallPolicyType-ces
.1.3.6.1.4.1.2505.1.14.3.1
firewallRuleType-cesType of rule that triggered this event.ro
FirewallRuleType-ces
.1.3.6.1.4.1.2505.1.14.3.2
firewallRuleNumber-cesNumber of the rule that triggered this event.ro
INTEGER
.1.3.6.1.4.1.2505.1.14.3.3
firewallSrcAddr-cesSource IP address of the packet.ro
IpAddress
.1.3.6.1.4.1.2505.1.14.3.6
firewallSrcPort-cesSource port address of the packet.ro
INTEGER
.1.3.6.1.4.1.2505.1.14.3.7
firewallDestAddr-cesDestination IP address of the packet.ro
IpAddress
.1.3.6.1.4.1.2505.1.14.3.8
firewallDestPort-cesDestination port of the packet.ro
INTEGER
.1.3.6.1.4.1.2505.1.14.3.9
firewallProtocolID-cesThe value of the protocol field in the IP header.ro
INTEGER
.1.3.6.1.4.1.2505.1.14.3.10
firewallRuleAction-cesAction defined for the triggered rule.ro
FirewallRuleAction-ces
.1.3.6.1.4.1.2505.1.14.3.11
CONTIVITY-TRAPS-V1-MIB - SNMP MIB Reference | MIBs Explorer