CONTIVITY-TRAPS-V1-MIB
AI MIB Summary
The CONTIVITY-TRAPS-V1-MIB module defines SNMP trap notifications and associated binding objects for VPN routers to report critical connectivity events and session state changes. These traps enable network management systems to detect and react to VPN tunnel failures, authentication errors, or link status transitions in real time.
This MIB defines the traps, and bind objects used in the traps, that are sent by the VPN Router.
Main OID:
contivityTrapsV1.1.3.6.1.4.1.2505.1.0
143
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
143 total| Object Name |
|---|
coldStartA coldStart trap signifies that the SNMPv2 entity, acting
in an agent role, is reinitializing itself and that its
configuration may have been altered. TRAP-TYPE .1.3.6.1.2.1.11.0.0 |
linkDownA linkDown trap signifies that the sending
protocol entity recognizes a failure in one of
the communication links represented in the
agent's configuration.
Varbind list:
ifIndex
ifAdminStatus
ifOperStatus
ifDescr
ifType
ifReasonForStatus-ces
ifPhysLocation-ces
ifPhysRelPos-ces
ifIpAddr-ces
ifName-ces
ifTunnelRemoteIpAddr-ces
sysObjectID
sysName TRAP-TYPE .1.3.6.1.2.1.11.0.2 |
linkUpA linkUp trap signifies that the sending
protocol entity recognizes that one of the
communication links represented in the agent's
configuration has come up.
Varbind list:
ifIndex
ifAdminStatus
ifOperStatus
ifDescr
ifType
ifReasonForStatus-ces
ifPhysLocation-ces
ifPhysRelPos-ces
ifIpAddr-ces
ifName-ces
ifTunnelRemoteIpAddr-ces
sysObjectID
sysName TRAP-TYPE .1.3.6.1.2.1.11.0.3 |
authenticationFailureAn authenticationFailure trap signifies that the SNMPv2
entity, acting in an agent role, has received a protocol
message that is not properly authenticated.
The snmpEnableAuthenTraps object indicates
whether this trap will be generated.
snmpAuthenOperation-ces identifies the operation( ie. GetRequest,
GetNextRequest,... ) was being attempted.
snmpAuthenIpAddress-ces identifies the source IP address of
the operation.
snmpAuthenCommString-ces identifies the community string that
was used in the operation. TRAP-TYPE .1.3.6.1.2.1.11.0.5 |
contivityTrapsV1This MIB defines the traps, and bind objects used in the traps,
that are sent by the VPN Router. MODULE-IDENTITY .1.3.6.1.4.1.2505.1.0 |
RFC1213-MIBThis MIB defines the traps, and bind objects used in the traps,
that are sent by the VPN Router. Unknown .1.3.6.1.4.1.2505.1.0 |
powerUpTrapEntryPower Up TRAP-TYPE .1.3.6.1.4.1.2505.1.0.401 |
periodicHeartbeatTrapPeriodic Heartbeat TRAP-TYPE .1.3.6.1.4.1.2505.1.0.601 |
hardwareCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.1 |
hardDisk1StatusTrapHard Disk Number 1 Status TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1001 |
hardDisk0StatusTrapHard Disk Number 0 Status TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1002 |
memoryUsageTrapMemory Usage Status TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1003 |
lanCardStatusTrapStatus of any LAN cards on the system TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1004 |
cpuTwoStatusTrapStatus of second CPU. TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1005 |
fanOneStatusTrapStatus of the first CPU fan TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1006 |
fanTwoStatusTrapStatus of the second CPU fan TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1007 |
chassisFanStatusTrapStatus of the chassis fan. TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1008 |
fiveVoltsPosStatusTrapStatus of the +5 Volt power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.1009 |
fiveVoltsMinusTrapStatus of -5 Volt power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10010 |
threeVoltsPositiveTrapStatus of +3 Volt power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10011 |
twoDotFiveVATrapStatus of 2.5VA power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10012 |
twoDotFiveVBTrapStatus of 2.5VB power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10013 |
twelveVoltsPositveTrapStatus of +12 Volt power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10014 |
twelveVoltsMinsTrapStatus of -12 Volt power TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10015 |
normalTemperatureTrapStatus of the normal temperature reading TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10016 |
criticalTemperatureTrapStatus of the critical temperature reading TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10017 |
chassisIntrusionTrapThe chassis intrusion sensor indicates that the unit has been physically opened TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10018 |
dualPowerSupplyTrapStatus of the redundant power supplies TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10019 |
t1WANStatusTrapStatus of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
Warning: Device WanicX not initialized
Warning: Device WanicX PPP negotiating
Alert: Device WanicX PPP down
Alert: Device WanicX FR no support
Alert: Device WanicX Unknown DL
For T1:
Alert: Invalid Device X
Warning: Device LMCDTEX disabled
Alert: Device LMCDTEX down
Warning: Device LMCDTEX not initialized
For CSU/DSU:
Alert: Invalid Device X
Warning: Device LMCCDX disabled
Alert: Device LMCCDX down
Warning: Device LMCCDX not initialized TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10020 |
t3WANStatusTrapStatus of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP down
Warning: Device HSSIX PP initializing TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10021 |
hwAccelTrapStatus of hardware accelerator card.
Possible Values:
Invalid hardware accelerator unit %d;
Unknown hardware accelerator unit %d;
Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED;
Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED;
Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE;
Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING;
Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN;
Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED; TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10022 |
v90WANStatusTrapStatus of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
Healthy: Device IntModem-X: PPP is UP.
Alert: Device IntModem-X down
Warning: Device IntModem-X not initialized
Alert: Device IntModem-X: Call is UP. Internal Error.
Warning: Device IntModem-X is Down. Last dial-out attempt FAILED.
Healthy: Device IntModem-X is Down (No Active calls)
Warning: Device IntModem-X is in an UNKNOWN state TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10024 |
briWANStatusTrapStatus of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. Needs Host Reboot.
Disabled: Device BRI-X disabled
Alert: Device BRI-X down
Warning: Device BRI-X not initialized
Healthy: Device BRI-X: PPP is UP.
Alert: Device BRI-X: Call is UP. Internal Error.
Warning: Device BRI-X is Down. Last dial-out attempt FAILED.
Healthy: Device BRI-X is Down (No Active calls)
Alert: Device BRI-X is in an UNKNOWN state TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10025 |
serUartStatusTrapStatus of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device COMX is set for Serial Menu.
Disabled: Device COMX disabled
Warning: Device COMX not initialized
Healthy: Device COMX: PPP is UP.
Alert: Device COMX: Call is UP. Internal Error.
Warning: Device COMX is Down. Last dial-out attempt FAILED.
Healthy: Device COMX is Down (No Active calls)
Alert: Device COMX is in an UNKNOWN state TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10026 |
adslWANStatusTrapStatus of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disabled: Device ADIADSLX disabled
Alert: Device ADIADSLX down
Warning: Device ADIADSLX not initialized
Healthy: Device ADIADSLX up TRAP-TYPE .1.3.6.1.4.1.2505.1.1.0.10027 |
hardDisk1StatusHard Disk Number 1 Status.
Possible Values:
Warning: Hard Disk 1 : Device /ide1/ not available
Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/
Alert: Hard Disk 1 : Utilization exceeds 87.5%% on /ide1/ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.1 |
hardDisk0StatusHard Disk Number 0 Status.
Possible Values:
Warning: Hard Disk 0 : Device /ide0/ not available
Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/
Alert: Hard Disk 0 : Utilization exceeds 87.5%% on /ide0/ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.2 |
memoryUsageMemory Usage Status.
Possible Values:
Warning: Memory Usage : Utilization exceeds 75%
Alert: Memory Usage : Utilization exceeds 87.5%ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.3 |
lanCardStatusStatus of any LAN cards on the system.
Possible Values:
Please note that X corresponds to the Xth slot in the system.
Please note that Y corresponds to the relative position of the port
on the card in the Xth slot in the system.
Warning: LAN on Slot X Interface Y: Device feiX has no IP address;
Warning: LAN on Slot X Interface Y: Device feiX disabled;
Alert: LAN on Slot X Interface Y: Device feiX down;
Alert: LAN on Slot X Interface Y: Device feiX Invalid Device X
The Alert status above indicates that the interface has no
link when it should. Possible causes are improper connection
speeds and duplex, improper cabling or a configuration issue.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.4 |
cpuTwoStatusStatus of second CPU.
Possible Values:
Alert: CPU 2: Program load failed;
Alert: CPU 2: Bootup did not complete;
Alert: CPU 2: Communication lost;
Alert: CPU 2: Failed. Reason unknown;
Each of these indicates that the application CPU is
not functioning correctly. The system will continue to
function without the application processor. This can only
be sent from a system with multiple CPUs. See the Admin
Guide for a list of systems that contain multiple CPUs.
The CES will emit an audible alarm and the networking
performance will be degraded. A Nortel support
representative should be contacted if rese ing the CES
does not correct the problem.
The effect is the same in each case. The system will be
running with only one CPU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.5 |
fanOneStatusStatus of the first CPU fan.
Possible Values:
Alert: CPU One Fan: Fan not functioning;
This indicates that the fan on the primary processor is
running either below the specified speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
This is a high priority event which can prove catastrophic
to the processor as well as the system. This trap can only
be sent by systems which contain an actual fan on the
primary CPU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.6 |
fanTwoStatusStatus of the second CPU fan
Possible Values:
Alert: CPU Two Fan: Fan not functioning;
This indicates that the fan on the auxiliary processor is
running either below the specified speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
This is a high priority event which can prove catastrophic
to the processor as well as the system. This trap can only
be sent by systems which contain an actual fan on the
auxiliary CPU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.7 |
chassisFanStatusStatus of the chassis fan.
Possible Values:
Alert: Chassis Fan: Fan not functioning;
Alert: Chassis Fan 2: Fan not functioning;
This indicates that one of the chassis fans is running
either below the specified range of speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
If either of the fans are not working properly, the box
must be looked at by a service technician as soon as
possible. Not doing so will result in overheating of
the system, improper system operation, and possible
component failure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.8 |
fiveVoltsPositiveStatus of +5 Volt power.
Possible Values:
Alert: Voltage 5 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.9 |
fiveVoltsMinusStatus of -5 Volt power.
Possible Values:
Alert: Voltage 5 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.10 |
threeVoltsPositiveStatus of +3 Volt power.
Possible Values:
Alert: Voltage 3.3 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.11 |
twoDotFiveVAStatus of 2.5VA power.
Possible Values:
Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor.
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.12 |
twoDotFiveVBStatus of 2.5VB power.
Possible Values:
Alert: Voltage 2.5 VB: Voltage out of range;
This is the voltage supplied to the seconary processor.
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.13 |
twelveVoltsPositiveStatus of +12 Volt power.
Possible Values:
Alert: Voltage 12 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.14 |
twelveVoltsMinusStatus of -12 Volt power.
Possible Values:
Alert: Voltage 12 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.15 |
normalTemperatureStatus of normal temperature reading.
Possible Values:
Alert: Normal Temperature: Normal temperature out of range;
This indicates that the box is running above its rated
normal operating temperature. This may be the result of
an improperly working fan or a high ambient temperature.
The box is not guaranteed to run properly while running
above the normal operating temperature range. Performance
will be degraded. Not taking action to correct this
situation can result in component failure. Do not rely
on waiting for the criticalTemperatureTrap as that is
only supported by certain platforms.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.16 |
criticalTemperatureStatus of critical temperature reading.
Possible Values:
Alert: Critical Temperature: Critial temperature out of range;
This indicates that the box is running at a critically high
temperature above the normal operating range. This is only
supported on certain platforms. See the Admin Guide for a
list of platforms which support this.
The box must be shut down immediately. Component failure
may already have occurred. If the reason for such a high
operating temperature cannot be determined, contact a
qualified Nortel representative.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.17 |
chassisIntrusionThe chassis intrusion sensor indicates that the unit has been opened.
Possible Values:
Alert: Intrusion: Box has been opened;
The cover to the CES has been opened or is in the
process of being opened. This indicates a possible
physical security intrusion.
The system will continue to operate while the box
is opened. Check to insure that no unauthorized
persons have opened the unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.18 |
dualPowerSupplyStatus of the redundant power supplies.
Possible Values:
Alert: Dual Power Supply: Redundant supply faulted
This indicates that, on systems with redundant power
supplies, one of the power supplies is not working.
This trap can only be sent from systems which have
redundant power supplies. The system will continue
to run with only one power supply working. A new
power supply must be obtained via an authorized
Nortel representative as quickly as possible.
This will help reduce the risk window of system failure
in the event that the working power supply ceases to
function.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.19 |
t1WANStatusStatus of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
Warning: Device WanicX not initialized
Warning: Device WanicX PPP negotiating
Alert: Device WanicX PPP down
Alert: Device WanicX FR no support
Alert: Device WanicX Unknown DL
For T1:
Alert: Invalid Device X
Warning: Device LMCDTEX disabled
Alert: Device LMCDTEX down
Warning: Device LMCDTEX not initialized
For CSU/DSU:
Alert: Invalid Device X
Warning: Device LMCCDX disabled
Alert: Device LMCCDX down
Warning: Device LMCCDX not initializedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.20 |
t3WANStatusStatus of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP down
Warning: Device HSSIX PP initializingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.21 |
hwAccelStatusStatus of hardware accelerator card.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.22 |
v90WANStatusStatus of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
Healthy: Device IntModem-X: PPP is UP.
Alert: Device IntModem-X down
Warning: Device IntModem-X not initialized
Alert: Device IntModem-X: Call is UP. Internal Error.
Warning: Device IntModem-X is Down. Last dial-out attempt FAILED.
Healthy: Device IntModem-X is Down (No Active calls)
Warning: Device IntModem-X is in an UNKNOWN statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.24 |
briWANStatusStatus of ISDN BRI Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. Needs Host Reboot.
Disabled: Device BRI-X disabled
Alert: Device BRI-X down
Warning: Device BRI-X not initialized
Healthy: Device BRI-X: PPP is UP.
Alert: Device BRI-X: Call is UP. Internal Error.
Warning: Device BRI-X is Down. Last dial-out attempt FAILED.
Healthy: Device BRI-X is Down (No Active calls)
Alert: Device BRI-X is in an UNKNOWN statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.25 |
serUartStatusStatus of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device COMX is set for Serial Menu.
Disabled: Device COMX disabled
Warning: Device COMX not initialized
Healthy: Device COMX: PPP is UP.
Alert: Device COMX: Call is UP. Internal Error.
Warning: Device COMX is Down. Last dial-out attempt FAILED.
Healthy: Device COMX is Down (No Active calls)
Alert: Device COMX is in an UNKNOWN statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.26 |
adslWANStatusStatus of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disabled: Device ADIADSLX disabled
Alert: Device ADIADSLX down
Warning: Device ADIADSLX not initialized
Healthy: Device ADIADSLX upro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.1.27 |
serverCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.2 |
radiusAcctServerTrapStatus of External Radius Accounting Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3001 |
backupServerTrapStatus of External Disk Backup Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3002 |
diskRedundencyTrapStatus of Local Disk Redundency TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3003 |
intLDAPServerTrapStatus of Internal LDAP Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3004 |
loadBalancingServerTrapStatus of Load Balancing Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3005 |
dnsServerTrapStatus of DNS Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3006 |
snmpServerTrapStatus of SNMP Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3007 |
ipAddressPoolTrapStatus of the IP address pool TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3008 |
extLDAPServerTrapStatus of External LDAP Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.3009 |
radiusAuthServerTrapStatus of Radius Authentication Server TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30010 |
certificateServerTrapStatus of Certificates Validity
Possible Values:
Healthy: Certificates Validity: Operational;
Alert: Certificates Validity: All certificates are going to expire/expired;
Warning: Certificates Validity: One/more certificate is invalid;
Disabled: Certificates Validity: No certificate defined; TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30011 |
extLDAPAuthServerTrapStatus of External LDAP Authentication Server.
Possible Values:
Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable);
Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable); TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30012 |
cmpServerTrapStatus of CMP Server.
Possible Values:
One/more Certificate Requests error: there is at least one request error;
One/more Certificate Requests processing: there is at least one request in processing;
No Certificate Requests submitted: there is no request sent; TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30013 |
dhcpServerTrapStatus of DHCP Server
Possible Values:
Disabled: DHCP Server is Disabled
Alert: DHCP Server is NOT configured
Alert: DHCP Server is configured and operational, Using backup config
Alert: No IP Address available for subnet
Alert: DHCP Server is configured and server is DOWN
Healthy: DHCP Server is Operational
Warning: Subnet low on IP Addresses
Warning: DHCP Server Initializing
Warning: DHCP Server is Enabled, but status Unknown cannot be determined TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30014 |
crlServerTrapStatus of CRL Server. TRAP-TYPE .1.3.6.1.4.1.2505.1.2.0.30015 |
radiusAcctServerStatus of External Radius Accounting Server.
Possible Values:
Warning: RADIUS Accounting Server: Server not configured
Alert: RADIUS Accounting Server: Error
Alert: RADIUS Accounting Server: Not Configuredro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.1 |
backupServerStatus of External Disk Backup Server.
Possible Values:
Warning: Auto Backup Servers: Server not configured.
Warning: Auto Backup Servers: Can't backup to xxx yyy zzz
Alert: Auto Backup Servers: Can't backup to xxx yyy zzz
Can't backup to xxx yyy zzz is issued as an alert
when none of the servers can be reached.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.2 |
diskRedundencyStatus of Local Disk Redundency.
Possible Values:
Alert: Disk Redundancy: Not Configured
Alert: Disk Redundancy: Errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.3 |
intLDAPServerStatus of Internal LDAP Server.
Possible Values:
Warning : Internal LDAP Server : Restore in progress
Alert : Internal LDAP Server : Server is downro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.4 |
loadBalancingServerStatus of Load Balancing Server.
Possible Values:
Disabled: Load Balancing Service: Server not enabled;
Warning: Load Balancing Service: Timed out waiting for response from server;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.5 |
dnsServerStatus of DNS Server.
Possible Values:
Warning: DNS Servers : Error
Warning: DNS Servers : Operational
Alert: DNS Servers : Configured
Alert: DNS Servers : Error
The values have the following meaning:
Warning: DNS Servers : Error
Warning: DNS Servers : Operational
Alert: DNS Servers : Configured
Alert: DNS Servers : Errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.6 |
snmpServerStatus of SNMP Server.
Possible Values:
Warning: SNMP Servers : Error
Warning: SNMP Servers : Can't reach xxx.xxx.xxx.xxx or yyy.yyy.yyy.yyy
Alert: SNMP Servers : Error
The values have the following meaning:
Warning: SNMP Servers : Error
Alert: SNMP Servers : Errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.7 |
ipAddressPoolStatus of the IP address pool.
Possible Values:
Warning: IP Address Pool : Reserved address count is low.
Warning: IP Address Pool : DHCP server(s) unavailable
Alert: IP Address Pool : Server is down
Alert: IP Address Pool : Not Configured
Alert: IP Address Pool : No IP address available.
Alert: IP Address Pool : Reserved address count is low.
Alert: IP Address Pool : Associated system task failed.
Alert: IP Address Pool : Server not configured
Alert: IP Address Pool : Error
The values have the following meaning:
Warning: IP Address Pool : Reserved address count is low.
Alert: IP Address Pool : Server is down
Alert: IP Address Pool : Not Configured
Alert: IP Address Pool : No IP address available.
Alert: IP Address Pool : Associated system task failed.
Alert: IP Address Pool : Server not configured
Alert: IP Address Pool : Errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.8 |
extLDAPServerStatus of External LDAP Server.
Possible Values:
Warning: External LDAP Servers : Server is down
Alert: External LDAP Servers : Server is down
The values have the following meaning:
Warning: External LDAP Servers : Server is down
Alert: External LDAP Servers : Server is downro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.9 |
radiusAuthServerStatus of Radius Authentication Server.
Possible Values:
Warning: RADIUS Authentication Servers : Error
Alert: RADIUS Authentication Servers : Error
The values have the following meaning:
Warning: RADIUS Authentication Servers : Error
Alert: RADIUS Authentication Servers : Errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.10 |
certificateServerStatus of Certificates Validity.
Possible Values:
Alert: Certificates Validity: All certificates are going to expire/expired;
Warning: Certificates Validity: One/more certificate is invalid;
Disabled: Certificates Validity: No certificate defined;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.11 |
extLDAPAuthServerStatus of External LDAP Authentication Server.
Possible Values:
Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable);
Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.12 |
cmpServerStatus of CMP Server.
Possible Values:
One/more Certificate Requests error: there is at least one request error;
One/more Certificate Requests processing: there is at least one request in processing;
No Certificate Requests submitted: there is no request sent;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.13 |
dhcpServerStatus of DHCP Server.
Possible Values:
Disabled: DHCP Server is Disabled
Alert: DHCP Server is NOT configured
Alert: DHCP Server is configured and operational, Using backup config
Alert: No IP Address available for subnet
Alert: DHCP Server is configured and server is DOWN
Healthy: DHCP Server is Operational
Warning: Subnet low on IP Addresses
Warning: DHCP Server Initializing
Warning: DHCP Server is Enabled, but status Unknown cannot be determinedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.14 |
crlServerStatus of CRL Server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.2.15 |
serviceCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.3 |
netBuffersTrapNetwork buffer usage TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5001 |
fireWallTrapStatus of internal firewall TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5002 |
fipsStatusTrapStatus of FIPS TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5003 |
licensingStatusTrapStatus temporary SW Licenses TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5004 |
natStatusTrapStatus of Network Address Translator TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5005 |
antiSpoofingStatusTrapStatus of Anti Spoofing Feature TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5006 |
sslVpnStatusTrapStatus of SSL-VPN Accelerator TRAP-TYPE .1.3.6.1.4.1.2505.1.3.0.5007 |
netBuffersNetwork buffer usage.
Possible Values:
Warning: Buffer Usage : Utilization exceeds 75%
Alert: Buffer Usage : Utilization exceeds 87.5%ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.1 |
fireWallStatus of internal firewall.
Possible Values:
Disabled: Firewall: Firewall disabled;
Disabled: Firewall: Firewall stopped;
Warning: Firewall: Current Firewall is %s. Reboot is required to start %s;
Warning: Firewall: Firewall state is not known!;
Warning: Firewall: Daemon loading policy;
Alert: Firewall: Firewall requires reboot to start;
Alert: Firewall: Daemon task does not exist;
Alert: Firewall: Daemon task is suspended;
The values have the following meaning:
Disabled: Firewall: Firewall disabled;
Warning: Firewall: Current Firewall is %s. Reboot is required to start %s;
Warning: Firewall: Firewall state is not known!;
Disabled: Firewall: Firewall stopped;
Warning: Firewall: Daemon loading policy;
Alert: Firewall: Firewall requires reboot to start;
Alert: Firewall: Daemon task does not exist;
Alert: Firewall: Daemon task is suspended;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.2 |
fipsStatusStatus of FIPS.
Possible Values:
Warning: FIPS: Random generator test failed;
Warning: FIPS: DESMAC check on executables Failed;
Warning: FIPS: DES KAT Test Failed;
Warning: FIPS: SHA1 Self Test Failed;
Alert: FIPS: status not known;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.3 |
licensingStatusStatus of temporary SW Licenses.
Possible Values:
Warning: Licensing: Temporary key will expire within 5 days;
Alert: Licensing: Temporary key has expired;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.4 |
natStatusStatus of Network Address Translator.
Possible Values:
Disabled: NAT: NAT disabled;
Warning: NAT: Reboot is required to start Interface NAT;
Warning: NAT: NAT state is not known!;
Alert: NAT: All Addresses in the Address Translation pool are used;
Alert: NAT: LDAP policy parse failed - Using system default policy;
The values have the following meaning:
Disabled: NAT: NAT disabled; Existing NAT sessions are not deleted, but
Warning: NAT: Reboot is required to start Interface NAT;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.5 |
antiSpoofingStatusStatus of Anti Spoofing Feature.
Possible Values:
Disabled: Anti-Spoofing is Disabled;
Warning: Anti-Spoofing : Packets Dropped;
Alert: Anti-Spoofing state not known!;
The values have the following meaning:ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.6 |
sslVpnStatusStatus of SSL-VPN Accelerator.
Possible Values:
Disabled: Disabled
Disabled: HW not installed
Warning: Initialization in progress.
Warning: Configuration Errors - see eventlog for details.
Healthy: Operational
Alert: Unreachable: Error Comminicating with SSL-VPNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.3.7 |
loginCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.4 |
failedLoginTrapFailed Login Attempt TRAP-TYPE .1.3.6.1.4.1.2505.1.4.0.101 |
failedLoginFailed Login Attempt.
Possible Values:
Failed Login Attempt: Username=IPSEC Encrypted: Date/Time=(xx) ;
Failed Login Attempt: Username=(userid): Date/Time=(xx) ;
Failed Login Attempt. Invalid Account: Username=(userid): Date/Time=(xx) ;
Failed Remote Network Login: Username=(userid): Date/Time=(xx) ;
Failed Remote Application Login: Username=(userid): Date/Time=(xx) ;
The values have the following meaning:ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.4.1 |
intrusionCESTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.5 |
securityIntrusionTrapSecurity Intrusion TRAP-TYPE .1.3.6.1.4.1.2505.1.5.0.201 |
securityIntrusionSecurity Intrusion.
Possible Values:
Intruder: : Source: %s, Destination: %s;ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.5.1 |
powerUpTrapPower Up.
Possible Values:
Cold Startrodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.6 |
severityLevelSeverity of specific trap.ro Unknown .1.3.6.1.4.1.2505.1.7 |
systemNameSystem Name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.8 |
systemDateSystem Date.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.9 |
systemTimeSystem Time.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.10 |
systemUpTimeSystem Up Time.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.11 |
periodicHeartbeatPeriodic Heartbeat.
Possible Values:
Has been executed n timesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.12 |
snmpAgentTrapInfo-ces OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.14 |
snmpAgentAuthTrapInfo-ces OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.14.1 |
snmpAuthenOperation-cesSNMP operation attempted.ro Enumeration .1.3.6.1.4.1.2505.1.14.1.1 |
snmpAuthenIpAddress-cesIP address of host trying to access the CES.ro IpAddress .1.3.6.1.4.1.2505.1.14.1.2 |
snmpAuthenCommString-cesCommunity string used to access the CES.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.14.1.3 |
snmpAgentInterfaceInfo-ces OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.14.2 |
ifReasonForStatus-cesThe reason for the status change. These include:
unknown(1)
timed-out(2)ro IfReasonForStatus-ces .1.3.6.1.4.1.2505.1.14.2.1 |
ifPhysLocation-cesThe physical location of the port. This has the values of
motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5.ro PortLocation-ces .1.3.6.1.4.1.2505.1.14.2.2 |
ifPhysRelPos-cesThe relative position of the physical port at the
location defined by interfacePhysLocation.ro INTEGER .1.3.6.1.4.1.2505.1.14.2.3 |
ifIpAddr-cesFor physical ports this is the associated IP address.
For a tunnel connection it is the local IP address.ro IpAddress .1.3.6.1.4.1.2505.1.14.2.4 |
ifName-cesThe name of the interface, same as ifName.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2505.1.14.2.5 |
ifTunnelRemoteIpAddr-cesThe remote IP address of a tunnel connection.ro IpAddress .1.3.6.1.4.1.2505.1.14.2.6 |
snmpAgentFirewallInfo-ces OBJECT IDENTIFIER .1.3.6.1.4.1.2505.1.14.3 |
firewallRuleTriggeredTrapAn event sent at the user's request to signal that a rule has
been matched.
firewallPolicyType-ces
firewallRuleType-ces
firewallRuleNumber-ces
ifIndex
ifName-ces
firewallSrcAddr-ces
firewallSrcPort-ces
firewallDestAddr-ces
firewallDestPort-ces
firewallProtocolID-ces
firewallRuleAction-ces TRAP-TYPE .1.3.6.1.4.1.2505.1.14.3.0.1 |
firewallPolicyType-cesPolicy type.ro FirewallPolicyType-ces .1.3.6.1.4.1.2505.1.14.3.1 |
firewallRuleType-cesType of rule that triggered this event.ro FirewallRuleType-ces .1.3.6.1.4.1.2505.1.14.3.2 |
firewallRuleNumber-cesNumber of the rule that triggered this event.ro INTEGER .1.3.6.1.4.1.2505.1.14.3.3 |
firewallSrcAddr-cesSource IP address of the packet.ro IpAddress .1.3.6.1.4.1.2505.1.14.3.6 |
firewallSrcPort-cesSource port address of the packet.ro INTEGER .1.3.6.1.4.1.2505.1.14.3.7 |
firewallDestAddr-cesDestination IP address of the packet.ro IpAddress .1.3.6.1.4.1.2505.1.14.3.8 |
firewallDestPort-cesDestination port of the packet.ro INTEGER .1.3.6.1.4.1.2505.1.14.3.9 |
firewallProtocolID-cesThe value of the protocol field in the IP header.ro INTEGER .1.3.6.1.4.1.2505.1.14.3.10 |
firewallRuleAction-cesAction defined for the triggered rule.ro FirewallRuleAction-ces .1.3.6.1.4.1.2505.1.14.3.11 |