Home/Catalog/COMM-BOARD-MIB

COMM-BOARD-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for COMM-BOARD-MIB.

139
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

139 total
Object Name
pentairTechProd
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609
RFC1155-SMI
Unknown
.1.3.6.1.4.1.26609
carelBoardMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2
menuInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1
coolSetPoint
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.1
cspNameCooling Setpoint menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.1.1
cspValueCooling Setpoint menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.rw
INTEGER
.1.3.6.1.4.1.26609.2.1.1.2
coolSetPointMin
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.2
csplNameCooling Setpoint Low Limit menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.2.1
csplValueCooling Setpoint Low Limit menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.ro
INTEGER
.1.3.6.1.4.1.26609.2.1.2.2
coolSetPointMax
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.3
csphNameCooling Setpoint High Limit menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.3.1
csphValueCooling Setpoint High Limit menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.ro
INTEGER
.1.3.6.1.4.1.26609.2.1.3.2
coolDifferential
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.4
cdNameCooling Differential menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.4.1
cdValueCooling Differential menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.rw
INTEGER
.1.3.6.1.4.1.26609.2.1.4.2
heatSetPoint
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.5
hspNameHeater Setpoint menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.5.1
hspValueHeater Setpoint menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.rw
INTEGER
.1.3.6.1.4.1.26609.2.1.5.2
heatSetPointMin
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.6
hsplNameHeater Setpoint Low Limit menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.6.1
hsplValueHeater Setpoint Low Limit menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.ro
INTEGER
.1.3.6.1.4.1.26609.2.1.6.2
heatSetPointMax
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.7
hsphNameHeater Setpoint High Limit menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.7.1
hsphValueHeater Setpoint High Limit menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.ro
INTEGER
.1.3.6.1.4.1.26609.2.1.7.2
heatDifferential
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.8
hdNameHeater Differential menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.8.1
hdValueHeater Differential menu value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.rw
INTEGER
.1.3.6.1.4.1.26609.2.1.8.2
unitOfMeasure
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.1.9
umNameUnit of Measure menu name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.1.9.1
umValueUnit of Measure menu value.ro
INTEGER
.1.3.6.1.4.1.26609.2.1.9.2
highTempSetPset point for high temp alarm.rw
INTEGER
.1.3.6.1.4.1.26609.2.1.10
lowTempSetPset point for low temp alarm.rw
INTEGER
.1.3.6.1.4.1.26609.2.1.11
faultInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2
frostAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.1
faNameFrost Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.1.1
faEnableFrost Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.1.2
faStateFrost Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.1.3
highTempAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.4
htaNameHigh Temp Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.4.1
htaEnableHigh Temp Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.4.2
htaStateHigh Temp Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.4.3
lowTempAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.5
ltaNameLow Temp Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.5.1
ltaEnableLow Temp Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.5.2
ltaStateLow Temp Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.5.3
inletFailAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.6
isfaNameInlet sensor failure Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.6.1
isfaEnableInlet sensor failure Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.6.2
isfaStateInlet sensor failure Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.6.3
outletFailAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.7
osfaNameOutlet Sensor Failure Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.7.1
osfaEnableOutlet Sensor Failure Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.7.2
osfaStateOutlet Sensor Failure Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.7.3
doorSmokeAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.8
dsaNameDoor Open / Smoke alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.8.1
dsaEnableDoor Open / Smoke alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.8.2
dsaStateDoor Open / Smoke alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.8.3
highPressureAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.9
hpaNameHigh Pressure Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.9.1
hpaEnableHigh Pressure Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.9.2
hpaStateHigh Pressure Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.9.3
contCommFailAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.2.10
ccfaNameController Comm Fail Alarm name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.10.1
ccfaEnableController Comm Fail Alarm enable object. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.10.2
ccfaStateController Comm Fail Alarm state object. True=1, False=2.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.2.10.3
faultLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.3
log1ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.1
log2ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.2
log3ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.3
log4ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.4
log5ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.5
log6ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.6
log7ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.7
log8ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.8
log9ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.9
log10ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.10
log11ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.11
log12ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.12
log13ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.13
log14ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.14
log15ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.15
log16ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.16
log17ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.17
log18ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.18
log19ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.19
log20ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.20
log21ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.21
log22ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.22
log23ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.23
log24ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.24
log25ValueLog1 = newest, Log25 = oldest, Alarms: 1=Frost, 4=High Temp, 5=Low Temp, 6=Inlet Fail, 7=Outlet Fail, 8=DoorSmoke, 9=High Pressurero
INTEGER
.1.3.6.1.4.1.26609.2.3.25
dataLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.4
inletSensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.4.1
p1iNameData Log Probe 1 name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.4.1.1
p1iValueData Log Probe 1 value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.ro
INTEGER
.1.3.6.1.4.1.26609.2.4.1.2
outletSensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.4.2
p2iNameData Log Probe 2 name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.4.2.1
p2iValueData Log Probe 2 value. Divide by 10. Read (26609.2.1.9.2) for unit of measure.ro
INTEGER
.1.3.6.1.4.1.26609.2.4.2.2
cbNotification
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.5
trapFreq
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.5.1
trapRateSet rate at which traps will be sent.rw
Enumeration
.1.3.6.1.4.1.26609.2.5.1.1
trapIntervalInterval at which traps will be repeated. Multiple of 10 seconds.rw
INTEGER
.1.3.6.1.4.1.26609.2.5.1.2
trapList
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.5.2
frostAlarmEVFrost Alarm trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.51
startUpHiTempEVHigh Temp Alarm at Start-up trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.52
startUpLowTempEVLow Temp Alarm at Start-up trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.53
highTempAlarmEVHigh Temp Alarm trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.54
lowTempAlarmEVLow Temp Alarm trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.55
inletSensAlarmEVInlet sensor failure Alarm trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.56
outletSensAlarmEVOutlet sensor failure Alarm trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.57
doorSmokeEVDoor Smoke trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.58
highPressureEVHigh Pressure trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.59
contcommfailEVController Comm Fail trap object
TRAP-TYPE
.1.3.6.1.4.1.26609.2.5.2.0.60
frostTrapFrost Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.1
startUpHiTempTrapStartup High Temp Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.2
startUpLowTempTrapStartup Low Temp Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.3
highTempTrapHigh Temp Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.4
lowTempTrapLow Temp Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.5
inletSensFailTrapInlet Sensor Failure Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.6
outletSensFailTrapOutlet Sensor Failure Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.7
doorSmokeTrapDoor Open / Smoke Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.8
highPressureTrapHigh Pressure Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.9
contcommfailTrapController Comm Fail Alarm Trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.5.2.10
addressInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.20
deviceIPDevice IP Address.rw
IpAddress
.1.3.6.1.4.1.26609.2.20.1
gatewayIPgateway IP Address.rw
IpAddress
.1.3.6.1.4.1.26609.2.20.2
subnetMaskSubnet Mask Address.rw
IpAddress
.1.3.6.1.4.1.26609.2.20.3
trapIPtrap IP Address.rw
IpAddress
.1.3.6.1.4.1.26609.2.20.4
dhcpServerDefine dhcp server's state. True means dhcp is in use. True=1, False=2.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.20.5
snmpCommcommunity string. must be between 4 and 8 chars. char must be > 0x20.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.20.6
revisionIDInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.26609.2.21
identificationUnit's identification. must be between 1 and 8 chars. char must be > 0x20.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.21.1
commRevcommunication board revision. First char is Major and second is Minor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.21.2
controlRevcontroller revision number.ro
INTEGER
.1.3.6.1.4.1.26609.2.21.3
commSerialNumComm Board serial number. upto 12 number chars.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.21.4
unitSerialNumUnit serial number. upto 16 chars.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.21.5
unitModelNumUnit Model number. upto 16 chars.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.21.6
stationNameStation name. upto 240 chars.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.26609.2.21.7
COMM-BOARD-MIB - SNMP MIB Reference | MIBs Explorer