COLUBRIS-SYSTEM-MIB
Imported Objects
Objects
66 total| Object Name |
|---|
colubrisSystemMIB MODULE-IDENTITY .1.3.6.1.4.1.8744.5.6 |
colubrisSystemMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.1 |
systemInfo OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.1.1 |
systemProductNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.1 |
systemFirmwareRevisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.2 |
systemBootRevisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.3 |
systemHardwareRevisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.4 |
systemSerialNumberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.5 |
systemConfigurationVersionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.6 |
systemUpTimero Counter32 UNITS "seconds" .1.3.6.1.4.1.8744.5.6.1.1.7 |
systemMacAddressro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.8 |
systemWanPortIpAddressro IpAddress .1.3.6.1.4.1.8744.5.6.1.1.9 |
systemProductFlavorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.10 |
systemDeviceIdentificationro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.11 |
systemFirmwareBuildDatero OCTET STRING .1.3.6.1.4.1.8744.5.6.1.1.12 |
systemControllerModero Enumeration .1.3.6.1.4.1.8744.5.6.1.1.13 |
systemCDPOperStatero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.14 |
systemLLDPOperStatero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.1.15 |
systemTime OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.1.2 |
systemTimeUpdateModerw Enumeration .1.3.6.1.4.1.8744.5.6.1.2.1 |
systemTimeLostWhenRebootingro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.2.2 |
systemTimeDSTOnrwdeprecated TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.2.3 |
systemDaterw OCTET STRING .1.3.6.1.4.1.8744.5.6.1.2.4 |
systemTimeOfDayrw OCTET STRING .1.3.6.1.4.1.8744.5.6.1.2.5 |
systemTimeZonerw OCTET STRING .1.3.6.1.4.1.8744.5.6.1.2.6 |
systemTimeServerTable SEQUENCE OF SystemTimeServerEntry .1.3.6.1.4.1.8744.5.6.1.2.7 |
systemTimeServerEntry SystemTimeServerEntry .1.3.6.1.4.1.8744.5.6.1.2.7.1 |
systemTimeServerIndex Integer32 .1.3.6.1.4.1.8744.5.6.1.2.7.1.1 |
systemTimeServerAddressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.2.7.1.2 |
systemTimeServerNotificationEnabledrw ColubrisNotificationEnable (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.2.8 |
adminAccess OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.1.3 |
adminAccessAuthenModerw ColubrisAuthenticationMode (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.3.1 |
adminAccessAuthenProfileIndexrw ColubrisProfileIndexOrZero (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.3.2 |
adminAccessMaxLoginAttemptsrw Integer32 .1.3.6.1.4.1.8744.5.6.1.3.3 |
adminAccessLockOutPeriodrw Integer32 .1.3.6.1.4.1.8744.5.6.1.3.4 |
adminAccessLoginNotificationEnabledrw ColubrisNotificationEnable (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.3.5 |
adminAccessAuthFailureNotificationEnabledrw ColubrisNotificationEnable (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.3.6 |
adminAccessInforo DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8744.5.6.1.3.7 |
adminAccessProfileTable SEQUENCE OF AdminAccessProfileEntry .1.3.6.1.4.1.8744.5.6.1.3.8 |
adminAccessProfileEntry AdminAccessProfileEntry .1.3.6.1.4.1.8744.5.6.1.3.8.1 |
adminAccessProfileIndex Integer32 .1.3.6.1.4.1.8744.5.6.1.3.8.1.1 |
adminAccessUserNamero OCTET STRING .1.3.6.1.4.1.8744.5.6.1.3.8.1.2 |
adminAccessAdministrativeRightsro Enumeration .1.3.6.1.4.1.8744.5.6.1.3.8.1.3 |
adminAccessLogoutNotificationEnabledrw ColubrisNotificationEnable (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.3.9 |
heartbeat OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.1.4 |
heartbeatPeriodrw Integer32 .1.3.6.1.4.1.8744.5.6.1.4.1 |
heartbeatNotificationEnabledrw ColubrisNotificationEnable (COLUBRIS-TC) .1.3.6.1.4.1.8744.5.6.1.4.2 |
colubrisSystemMIBNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.2 |
colubrisSystemMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.2.0 |
adminAccessAuthFailureNotification NOTIFICATION-TYPE .1.3.6.1.4.1.8744.5.6.2.0.1 |
adminAccessLoginNotification NOTIFICATION-TYPE .1.3.6.1.4.1.8744.5.6.2.0.2 |
systemColdStart NOTIFICATION-TYPE .1.3.6.1.4.1.8744.5.6.2.0.3 |
systemHeartbeatNotification NOTIFICATION-TYPE .1.3.6.1.4.1.8744.5.6.2.0.4 |
adminAccessLogoutNotification NOTIFICATION-TYPE .1.3.6.1.4.1.8744.5.6.2.0.5 |
timeServerFailure NOTIFICATION-TYPE .1.3.6.1.4.1.8744.5.6.2.0.6 |
colubrisSystemMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.3 |
colubrisSystemMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.3.1 |
colubrisSystemMIBCompliance Unknown .1.3.6.1.4.1.8744.5.6.3.1.1 |
colubrisSystemMIBComplianceDeprecateddeprecated Unknown .1.3.6.1.4.1.8744.5.6.3.1.2 |
colubrisSystemMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.8744.5.6.3.2 |
colubrisSystemMIBGroup Unknown .1.3.6.1.4.1.8744.5.6.3.2.1 |
colubrisAdminAccessProfileGroup Unknown .1.3.6.1.4.1.8744.5.6.3.2.2 |
colubrisSystemNotificationGroup Unknown .1.3.6.1.4.1.8744.5.6.3.2.3 |
colubrisAdminAccessNotificationGroup Unknown .1.3.6.1.4.1.8744.5.6.3.2.4 |
colubrisTimeNotificationGroup Unknown .1.3.6.1.4.1.8744.5.6.3.2.5 |
colubrisSystemMIBDeprecatedGroupdeprecated Unknown .1.3.6.1.4.1.8744.5.6.3.2.6 |
COLUBRIS-SYSTEM-MIB Technical Reference Overview
The COLUBRIS-SYSTEM-MIB SNMP MIB module published by Colubris defines 66 managed OID objects, including 45 scalar/column metrics, 2 SNMP tables, and 6 trap/notification events anchored at base OID .1.3.6.1.4.1.8744.5.6. Key tabular structures include adminAccessProfileTable, systemTimeServerTable. Monitored SNMP traps/notifications include adminAccessAuthFailureNotification, adminAccessLoginNotification, adminAccessLogoutNotification, systemColdStart, systemHeartbeatNotification, timeServerFailure.
Key OID Definitions in COLUBRIS-SYSTEM-MIB
.1.3.6.1.4.1.8744.5.6Generic system information for Colubris Networks devices.
.1.3.6.1.4.1.8744.5.6.1.3.8This table handles the profile of several administrator users. In tabular form in order to allow multiple instances on an agent.
.1.3.6.1.4.1.8744.5.6.1.2.7A table containing the list of SNTP time servers that can be used to synchronize the system time. In tabular form to allow multiple instances on an agent.
.1.3.6.1.4.1.8744.5.6.2.0.1Sent after an administrator authentication failure.
.1.3.6.1.4.1.8744.5.6.2.0.2Sent after an administrator is successfully authenticated.
.1.3.6.1.4.1.8744.5.6.2.0.5Sent after an administrator has logout.
.1.3.6.1.4.1.8744.5.6.2.0.3Sent at system boot up.
.1.3.6.1.4.1.8744.5.6.2.0.4Sent every heartbeatPeriod.
.1.3.6.1.4.1.8744.5.6.2.0.6Sent when a time server in the system time table is unreachable.
.1.3.6.1.4.1.8744.5.6.1.3.6Specifies if an adminAccessAuthFailureNotification event is generated when the number of successive unsuccessful authentications attempts exceed the value of adminAccessMaxLoginAttempts.
.1.3.6.1.4.1.8744.5.6.1.3.1Specifies if administrator authentication is performed locally or via a RADIUS server. You must have configured a RADIUS profile and the adminAccessAuthenProfileIndex attribute before you can select a profile or an error will be returned.
.1.3.6.1.4.1.8744.5.6.1.3.2Specifies the RADIUS profile to be used in order to authenticate the administrator. This parameter only applies when the adminAccessAuthenMode is set to 'profile'. When the special value zero is specified, no RADIUS server profile is selected.
.1.3.6.1.4.1.8744.5.6.1.3.7Contains various information about the administrator. This parameter is used in the adminAccessAuthFailureNotification event to return the administrator status to a management system.
.1.3.6.1.4.1.8744.5.6.1.3.4Specifies the duration when further login attempts are blocked after adminAccessMaxLoginAttempts has been reached. Setting this value to zero disables the lock out feature.
.1.3.6.1.4.1.8744.5.6.1.3.5Specifies if an adminAccessLoginNotification event is generated after an administrator is successfully authenticated.
.1.3.6.1.4.1.8744.5.6.1.3.9Specifies if an adminAccessLogoutNotification event is generated after an administrator logs out from the web interface.
.1.3.6.1.4.1.8744.5.6.1.3.3Specifies the number of successive unsuccessful authentications that must occur to generate an adminAccessAuthFailureNotification event.
.1.3.6.1.4.1.8744.5.6.3.2.4A collection of supported notifications
.1.3.6.1.4.1.8744.5.6.3.2.2A collection of objects providing the administrator access configuration capability.
.1.3.6.1.4.1.8744.5.6.3.1.1The compliance statement for entities which implement the Colubris Networks System MIB.
.1.3.6.1.4.1.8744.5.6.3.1.2The compliance statement for deprecated entities which implement the Colubris Networks System MIB.
.1.3.6.1.4.1.8744.5.6.3.2.6A collection of deprecated objects providing the System MIB capability.
.1.3.6.1.4.1.8744.5.6.3.2.1A collection of objects providing the System MIB capability.
.1.3.6.1.4.1.8744.5.6.3.2.3A collection of supported notifications
More MIBs from Colubris
Browse all ColubrisMIBs →SNMP MIB module
SNMP MIB module
SNMP MIB module
The COLUBRIS-PUBLIC-ACCESS-MIB facilitates the monitoring and management of Colubris Networks wireless access points and controllers, specifically exposing metrics related to public access session states, user authentication status, and bandwidth utilization for guest networks.
SNMP MIB module
The COLUBRIS-WDS-MIB facilitates SNMP-based monitoring and management of Colubris Wireless Distribution System (WDS) bridges, specifically tracking WDS link status, peer association states, and throughput statistics for point-to-point or point-to-multipoint wireless backhaul links.