The CHATEAU-CD-PRODUCT-MIB provides SNMP management nodes for Chateau Systems CD player hardware, enabling the monitoring of device-specific operational states and performance counters. This module facilitates remote diagnostics and configuration of optical media playback units within a networked environment.

This MIB defines Nodes and Data Objects to support Chateau Systems CD Players. This MIB has been distributed as part of the handout materials from the SNMP Technology Seminar presented by Chateau Systems. Any person or organization making use of this example MIB is responsible for ensuring its complete suitability for their own purposes. This includes the text of the legal disclaimers below, as well as all other aspects. Chateau Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should contact Chateau Systems to determine whether or not such changes have been made. In no event shall Chateau Systems be liable for any incidental, indirect, special, or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this document or the information contained in it, even if Chateau Systems has been advised of, known, or should have known, the possibility of such damages. Chateau Systems grants vendors, end-users, and other interested parties a non-exclusive license to use this specification in connection with the management of Chateau Systems products. Copyright November 2005 Chateau Systems, Inc.
Main OID:
chateauCDProductMIB.1.3.6.1.4.1.10910.2.2.3.1.1
56
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

56 total
Object Name
chateauCDProductMIB
MODULE-IDENTITY
.1.3.6.1.4.1.10910.2.2.3.1.1
chateauCDProdConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.1
cdStaticConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.1.1
cdStCfgManufacturerro
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.1.1.1
cdStCfgModelro
DisplayString
.1.3.6.1.4.1.10910.2.2.3.1.1.1.1.2
cdStCfgFirmwareRevro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10910.2.2.3.1.1.1.1.10
cdDynamicConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.1.2
cdDynCfgUserAliasrw
DisplayString
.1.3.6.1.4.1.10910.2.2.3.1.1.1.2.1
chateauCDProdControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.2
cdCtlPowerrw
Enumeration
.1.3.6.1.4.1.10910.2.2.3.1.1.2.1
cdCtlTrayDoorrw
Enumeration
.1.3.6.1.4.1.10910.2.2.3.1.1.2.2
cdCtlPlayingrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.10910.2.2.3.1.1.2.3
chateauCDProdStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.3
cdChassisStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1
cdChStPowerOnHoursro
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.1
cdChStLaserOnHoursro
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.2
cdChStCrcErrorCtrro
Counter32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.3
cdChStTemperaturero
Integer32 UNITS "Celcius"
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.4
cdChStPowerSupplyro
Enumeration
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.5
cdChangerStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2
cdChangerNbrCdSlotsro
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.1
cdChangerSlotTable
SEQUENCE OF CdChangerSlotEntry
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2
cdChangerSlotEntry
CdChangerSlotEntry
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1
cdChangerSlotNbr
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.1
cdChangerSlotStatusro
Enumeration
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.2
cdChangerSlotCDTrackPlayingro
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.3
cdChangerCDNbrTracksro
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2.1.4
cdChangerCDTrackTable
SEQUENCE OF CdChangerCDTrackEntry
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3
cdChangerCDTrackEntry
CdChangerCDTrackEntry
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1
cdChangerCDTrackNbr
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.1
cdChangerCDTrackPlayingro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.2
cdChangerCDTrackLengthSecsro
Unsigned32
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.3
cdChangerCDTrackLengthStrro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.4
cdChangerCDTrackTitlero
DisplayString
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.5
cdChangerCDTrackArtistro
DisplayString
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3.1.6
chateauCDProdEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.10
cdEventList
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0
cdChassisTempAlarmEv
NOTIFICATION-TYPE
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0.10
cdChassisTempOkayEv
NOTIFICATION-TYPE
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0.11
cdPowerSupplyEv
NOTIFICATION-TYPE
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0.20
cdEventControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1
cdEvCtlAgtPollFreqrw
Unsigned32 UNITS "seconds"
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.1
cdChassisTempAlarmThreshrw
Integer32 UNITS "Celcius"
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.2
cdChassisTempEvTrapEnrw
ChateauTrapControl (CHATEAUSYSTEMS-REGISTRATIONS-MIB)
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.10
cdPowerSupplyEvTrapEnrw
ChateauTrapControl (CHATEAUSYSTEMS-REGISTRATIONS-MIB)
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.20
cdEventDescriptors
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.10.2
cdEvSeverityro
ChateauEventSeverity (CHATEAUSYSTEMS-REGISTRATIONS-MIB)
.1.3.6.1.4.1.10910.2.2.3.1.1.10.2.1
cdEvDescriptionro
DisplayString
.1.3.6.1.4.1.10910.2.2.3.1.1.10.2.2
chateauCDProdConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.20
cdConformanceGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1
cdProdConfigGroup
Unknown
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1.1
cdProdControlGroup
Unknown
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1.2
cdProdStatusGroup
Unknown
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1.3
cdProdEventGroup
Unknown
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1.4
cdProdNotificationsGroup
Unknown
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1.5
cdCompliance
Unknown
.1.3.6.1.4.1.10910.2.2.3.1.1.20.2

CHATEAU-CD-PRODUCT-MIB Technical Reference Overview

The CHATEAU-CD-PRODUCT-MIB SNMP MIB module published by Chateau defines 56 managed OID objects, including 35 scalar/column metrics, 2 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.10910.2.2.3.1.1. Key tabular structures include cdChangerCDTrackTable, cdChangerSlotTable. Monitored SNMP traps/notifications include cdChassisTempAlarmEv, cdChassisTempOkayEv, cdPowerSupplyEv.

Key OID Definitions in CHATEAU-CD-PRODUCT-MIB

chateauCDProductMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1

This MIB defines Nodes and Data Objects to support Chateau Systems CD Players. This MIB has been distributed as part of the handout materials from the SNMP Technology Seminar presented by Chateau Systems. Any person or organization making use of this example MIB is responsible for ensuring its complete suitability for their own purposes. This includes the text of the legal disclaimers below, as well as all other aspects. Chateau Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should contact Chateau Systems to determine whether or not such changes have been made. In no event shall Chateau Systems be liable for any incidental, indirect, special, or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this document or the information contained in it, even if Chateau Systems has been advised of, known, or should have known, the possibility of such damages. Chateau Systems grants vendors, end-users, and other interested parties a non-exclusive license to use this specification in connection with the management of Chateau Systems products. Copyright November 2005 Chateau Systems, Inc.

cdChangerCDTrackTableSEQUENCEnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.3

Changer Track Table for a single CD.

cdChangerSlotTableSEQUENCEnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.2

CD Changer Slot Table.

cdChassisTempAlarmEvNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0.10

Sent when cdChStTemperature > cdChassisTempAlarmThresh. Will not be resent until cdChStTemperature drops below cdChasisTempAlarmThresh less 10%. This trap can be disabled by setting cdChassisTempEvTrapEn = trapDisable.

cdChassisTempOkayEvNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0.11

Sent when cdChStTemperature drops below cdChassisTempAlarmThresh. This trap can be disabled by setting cdChassisTempEvTrapEn = trapDisable.

cdPowerSupplyEvNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.10.0.20

Sent when cdChStPowerSupply changes from okay to voltageError, or from voltageError to okay. This trap can be disabled by setting cdPowerSupplyEvTrapEn = trapDisable.

cdChStCrcErrorCtrCounter32read-only
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.3

Counter for CRC errors encountered reading CDs. This Counter is initialized whenever the CD Player is powered on.

cdChStLaserOnHoursUnsigned32read-only
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.2

The total number of hours that this CD Player's Laser has been powered on in its lifetime. Trending this value may predict Laser failures.

cdChStPowerOnHoursUnsigned32read-only
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.1

The total number of hours that this CD Player has been powered on in its lifetime.

cdChStPowerSupplyINTEGERread-only
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.5

CD Player Power Supply status.

cdChStTemperatureInteger32read-only
.1.3.6.1.4.1.10910.2.2.3.1.1.3.1.4

CD Player internal chassis temperature.

cdChangerNbrCdSlotsUnsigned32read-only
.1.3.6.1.4.1.10910.2.2.3.1.1.3.2.1

The maximum number of CDs that can be loaded into this CD player. The size of (number of indexed entries in) the cdChangerSlotTable.

cdChassisTempAlarmThreshInteger32read-write
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.2

User settable to define the Chassis Temperature past which a Chassis Temperature Alarm will occur. Agent semantics will apply hysterisis logic so that traps to not repeat unecessarily when the chassis temperature is very close to this threshold. Persistent through system resets.

cdChassisTempEvTrapEnChateauTrapControlread-write
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.10

User settable to disable/enable Chassis Temperature alarms and okay events. Persistent through system resets.

cdComplianceunknownnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.20.2

Specification of mandatory & non-mandatory MIB objects.

cdCtlPlayingTruthValueread-write
.1.3.6.1.4.1.10910.2.2.3.1.1.2.3

CD Player 'play' status. Can be modified by the user. If cdCtlPower = off OR cdCtlTrayDoor = open, then the user cannot modify this value.

cdCtlPowerINTEGERread-write
.1.3.6.1.4.1.10910.2.2.3.1.1.2.1

Indicated CD Player Power status. Can be modified by the user.

cdCtlTrayDoorINTEGERread-write
.1.3.6.1.4.1.10910.2.2.3.1.1.2.2

CD Player tray door status. Can be modified by the user. If cdCtlPower = off, then the user cannot modify this value.

cdDynCfgUserAliasDisplayStringread-write
.1.3.6.1.4.1.10910.2.2.3.1.1.1.2.1

Any user assigned name for this CD player

cdEvCtlAgtPollFreqUnsigned32read-write
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.1

How often the Agent polls the CD Player for trappable conditions. Set = 0 to disable all traps. Persistent through system resets.

cdEvDescriptionDisplayStringaccessible-for-notify
.1.3.6.1.4.1.10910.2.2.3.1.1.10.2.2

Text which may provide the user with further diagnostic information.

cdEvSeverityChateauEventSeverityaccessible-for-notify
.1.3.6.1.4.1.10910.2.2.3.1.1.10.2.1

This value is sent with each trap as an indication of the intended severity of the event.

cdPowerSupplyEvTrapEnChateauTrapControlread-write
.1.3.6.1.4.1.10910.2.2.3.1.1.10.1.20

User settable to disable/enable Power Supply alarms and okay events. Persistent through system resets.

cdProdConfigGroupunknownnot-accessible
.1.3.6.1.4.1.10910.2.2.3.1.1.20.1.1

cdProdConfigGroup

More MIBs from Chateau

Browse all ChateauMIBs →