BroadworksMaintenance
AI MIB Summary
The BroadworksMaintenance MIB enables monitoring and management of system health, maintenance status, and operational metrics for BroadSoft enterprise communication platforms. It facilitates the tracking of critical service availability, software version states, and maintenance window configurations to ensure continuous VoIP and unified communications service delivery.
This is the System Management Information structure for the Broadsoft enterprise.
Main OID:
broadsoft.1.3.6.1.4.1.6431
109
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
109 total| Object Name |
|---|
broadsoftThis is the System Management Information structure for the Broadsoft enterprise. MODULE-IDENTITY .1.3.6.1.4.1.6431 |
broadworks OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1 |
common OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1 |
managedObjects OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.2 |
moServerModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.2.1 |
bwServerTypeGives the broadworks server type: { Application Server | Network Server | Media Server | Relay Server }ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.1.1 |
bwRedundancyTypeGives the broadworks server redundancy type: { Primary | Secondary | NotRedundant }ro Enumeration .1.3.6.1.4.1.6431.1.1.2.1.2 |
bwActiveSoftwareVersionGives the version of the active software version. An operator can change the active software version by setting this field.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.1.3 |
bwAdminStateServer admin state. 0- Lock, 1- Locking, 2- Unlock, 3- ShuttingDown, 4- Stopped, 5- Forced Lockrw Enumeration .1.3.6.1.4.1.6431.1.1.2.1.4 |
bwOperationalStateServer operational state. 0- Enabled, 1- Disabledro Enumeration .1.3.6.1.4.1.6431.1.1.2.1.5 |
bwResetServerRemotely reset the BroadWorks server. The reset action kicks in when the counter is set to 1.rw Enumeration .1.3.6.1.4.1.6431.1.1.2.1.6 |
bwSubComponentTableThis table exposes some key BroadWorks server sub components. It may or may not be empty depending on the server SEQUENCE OF BwSubComponentEntry .1.3.6.1.4.1.6431.1.1.2.1.7 |
bwSubComponentEntryThis row contains information about a software component in the system BwSubComponentEntry .1.3.6.1.4.1.6431.1.1.2.1.7.1 |
bwSubComponentIndexThis integer represents the a software component index in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.1.7.1.1 |
bwSubComponentNameThe name of an exposed subcomponentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.1.7.1.2 |
bwSubComponentInfoDisplays status information about the componentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.1.7.1.3 |
bwTargetSoftwareVersionGives the target software version. If the server is reset, the active server software version will be updated.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.1.8 |
bwRevertBackupLocationGives the location of the backup file to use if using the revert option of the reset command.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.1.9 |
moSoftwareVersionModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.2.2 |
bwUpdateSoftwareVersionTableThis counter is used to reload the installed software table. To do so, just set this register to 1 (reload)rw Enumeration .1.3.6.1.4.1.6431.1.1.2.2.1 |
bwSoftwareVersionTableThis table has an entry per software version installed on the server SEQUENCE OF BwSoftwareVersionEntry .1.3.6.1.4.1.6431.1.1.2.2.2 |
bwSoftwareVersionEntryThis row contains information on a particular braodworks software version installed on the server BwSoftwareVersionEntry .1.3.6.1.4.1.6431.1.1.2.2.2.1 |
bwSoftwareVersionIndexThis integer represents the a group index in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.2.2.1.1 |
bwSoftwareVersionNameThe name of a software load installed on the server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.2.1.2 |
bwSoftwareVersionInstallDateInstallation date for this software version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.2.1.3 |
bwSoftwareVersionStatusThe status of a software version.ro Enumeration .1.3.6.1.4.1.6431.1.1.2.2.2.1.4 |
bwSoftwarePatchTableThis table has an entry per service packs installed for each sofware versions SEQUENCE OF BwSoftwarePatchEntry .1.3.6.1.4.1.6431.1.1.2.2.3 |
bwSoftwarePatchEntryThis row contains information on a particular braodworks patch installed on the server BwSoftwarePatchEntry .1.3.6.1.4.1.6431.1.1.2.2.3.1 |
bwSoftwarePatchIndexThis integer an index of a patch installed in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.2.3.1.1 |
bwSoftwarePatchVersionNameThe name of a software load for which this patch applies. This field was obsoleted in BroadWorks release 14.0.roobsolete DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.3.1.2 |
bwSoftwarePatchNamePatch name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.3.1.3 |
bwSoftwarePatchTypePatch type. This field was obsoleted in BroadWorks release 14.0.roobsolete DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.3.1.4 |
bwSoftwarePatchInstallDateThis field was obsoleted in BroadWorks release 14.0.roobsolete DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.3.1.5 |
bwSoftwarePatchStateThe state of the patch.ro Enumeration .1.3.6.1.4.1.6431.1.1.2.2.3.1.6 |
bwSoftwarePatchOperationThis field was obsoleted in BroadWorks release 14.0.rwobsolete Enumeration .1.3.6.1.4.1.6431.1.1.2.2.3.1.7 |
bwSoftwarePatchBundlePatch Bundle name of the patch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.3.1.8 |
bwSoftwareThirdPartyTableThis table has an entry for third party software version used by the BroadWorks server SEQUENCE OF BwSoftwareThirdPartyEntry .1.3.6.1.4.1.6431.1.1.2.2.4 |
bwSoftwareThirdPartyEntryThis row contains information on an installed 3rd party software version BwSoftwareThirdPartyEntry .1.3.6.1.4.1.6431.1.1.2.2.4.1 |
bwSoftwareThirdPartyIndexThis integer represents the a group index in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.2.4.1.1 |
bwSoftwareThirdPartyNameThe name of a software load for which this service pack appliesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.4.1.2 |
bwSoftwareThirdPartyVersionA 3rd party software version idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.4.1.3 |
bwSoftwareThirdPartyStatusThe status of a 3rd party software version.ro Enumeration .1.3.6.1.4.1.6431.1.1.2.2.4.1.4 |
bwSoftwarePatchHistoryTableThis table contains information about all operation performed on patches. SEQUENCE OF BwSoftwarePatchHistoryEntry .1.3.6.1.4.1.6431.1.1.2.2.5 |
bwSoftwarePatchHistoryEntryEntry of the patch history table containing history of operations applied to patches. BwSoftwarePatchHistoryEntry .1.3.6.1.4.1.6431.1.1.2.2.5.1 |
bwSoftwarePatchHistoryIndexThis integer an index of a patch operation history.ro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.2.5.1.1 |
bwSoftwarePatchHistPatchNameThe name of the patch against which the operation was applied.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.5.1.2 |
bwSoftwarePatchHistTimeStampThe time stamp of the patch operation.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.5.1.3 |
bwSoftwarePatchHistNewStateThe new state of the patch.ro Enumeration .1.3.6.1.4.1.6431.1.1.2.2.5.1.4 |
bwSoftwarePatchImpactedFileTableThis table contains information about files modified by the patches applied on the system. SEQUENCE OF BwSoftwarePatchImpactedFileEntry .1.3.6.1.4.1.6431.1.1.2.2.6 |
bwSoftwarePatchImpactedFileEntryEntry of the patch impacted file table containing information about files modified by patches. BwSoftwarePatchImpactedFileEntry .1.3.6.1.4.1.6431.1.1.2.2.6.1 |
bwSoftwarePatchImpactedFileIndexThis integer an index of an impacted file/patch name.ro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.2.6.1.1 |
bwSoftwarePatchImpactedFilePatchNameThe name of the patch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.6.1.2 |
bwSoftwarePatchImpactedFileFileNameThe name of an impacted file.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.2.6.1.3 |
moDeviceModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.2.3 |
bwManagedObjectsTableTable of all sub-managed objects under BroadWorks control SEQUENCE OF BwManagedObjectsEntry .1.3.6.1.4.1.6431.1.1.2.3.1 |
bwManagedObjectsEntryThis row contains information on a particular sub-managed object BwManagedObjectsEntry .1.3.6.1.4.1.6431.1.1.2.3.1.1 |
bwManagedObjectsIndexThis integer represents the a managed object index in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.2.3.1.1.1 |
bwManagedObjectsNameThe name of a managed object controlled by BroadWorksro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.3.1.1.2 |
bwManagedObjectsProtocolThe protocol supported by a managed object controlled by BroadWorksro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.3.1.1.3 |
bwManagedObjectsTypeThe type of a managed object controlled by BroadWorksro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.2.3.1.1.4 |
bwManagedObjectsAdminStateThe administrative state of a managed object controlled by BroadWorks. 0- Lock, 1- locking, 2- Unlockrw Enumeration .1.3.6.1.4.1.6431.1.1.2.3.1.1.5 |
bwManagedObjectsOperationalStateThe operational state of a managed object controlled by BroadWorks. 0- Enabled, 1- Disabledro Enumeration .1.3.6.1.4.1.6431.1.1.2.3.1.1.6 |
thresholds OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.3 |
thCounterModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.3.1 |
bwCounterThresholdTableTable of all the thresholds set against counters in the system SEQUENCE OF BwCounterThresholdEntry .1.3.6.1.4.1.6431.1.1.3.1.1 |
bwCounterThresholdEntryThis row contains information on a particular counter threshold BwCounterThresholdEntry .1.3.6.1.4.1.6431.1.1.3.1.1.1 |
bwCounterThresholdIndexThis integer represents the index of a counter threshold in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.3.1.1.1.1 |
bwCounterThresholdDescriptionA description for this threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.3.1.1.1.2 |
bwCounterThresholdNameThe name of a counter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.3.1.1.1.3 |
bwCounterThresholdInitialValueThe initial counter threshold valuerw Integer32 .1.3.6.1.4.1.6431.1.1.3.1.1.1.4 |
bwCounterThresholdOffsetValueThe offset to be added to the current threshold value once an alarm has been sentrw Integer32 .1.3.6.1.4.1.6431.1.1.3.1.1.1.5 |
bwCounterThresholdCurrentValueThe threshold value at which the next alarm will be generatedro Gauge32 .1.3.6.1.4.1.6431.1.1.3.1.1.1.6 |
bwCounterThresholdSeverityThe severity of the alarm to be sentrw Enumeration .1.3.6.1.4.1.6431.1.1.3.1.1.1.7 |
bwCounterThresholdControlThis scalar controls the life cycle of the threshold. Setting this counter to create(3) using an unused index creates a row with the specified index. Setting it with an already used index has no effect. Setting this counter to delete(2) removes the entry.rw Enumeration .1.3.6.1.4.1.6431.1.1.3.1.1.1.8 |
thGaugeModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.3.2 |
bwGaugeThresholdTableTable of all the thresholds set against gauges in the system SEQUENCE OF BwGaugeThresholdEntry .1.3.6.1.4.1.6431.1.1.3.2.1 |
bwGaugeThresholdEntryThis row contains information on a particular gauge threshold BwGaugeThresholdEntry .1.3.6.1.4.1.6431.1.1.3.2.1.1 |
bwGaugeThresholdIndexThis integer represents the index of a gauge threshold in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.3.2.1.1.1 |
bwGaugeThresholdDescriptionA description for this threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.3.2.1.1.2 |
bwGaugeThresholdNameThe name of a gauge.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.3.2.1.1.3 |
bwGaugeThresholdNotifyLowThe gauge value at which an alarm will be generated when the gauge value reaches or crosses the NotifyHigh level in a rising direction. Subsequent similar crossings of the NotifyHigh level will not generate an alarm until the gauge has reached or crossed the corresponding NotifyLow level.rw Integer32 .1.3.6.1.4.1.6431.1.1.3.2.1.1.4 |
bwGaugeThresholdNotifyHighThe gauge value at which an alarm will be generated when the gauge value reaches or crosses the NotifyLow level in a falling direction. Subsequent similar crossings of the NotifyLow level will not generate an alarm until the gauge has reached or crossed the corresponding NotifyHigh level.rw Integer32 .1.3.6.1.4.1.6431.1.1.3.2.1.1.5 |
bwGaugeThresholdSeverityThe severity of the alarm to be sentrw Enumeration .1.3.6.1.4.1.6431.1.1.3.2.1.1.6 |
bwGaugeThresholdControlThis scalar controls the life cycle of the threshold. Setting this gauge to delete(2) removes the entry.rw Enumeration .1.3.6.1.4.1.6431.1.1.3.2.1.1.7 |
thAlarmModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.3.3 |
bwAlarmThresholdTableTable of all the thresholds set against alarms in the system SEQUENCE OF BwAlarmThresholdEntry .1.3.6.1.4.1.6431.1.1.3.3.1 |
bwAlarmThresholdEntryThis row contains information on a particular alarm threshold BwAlarmThresholdEntry .1.3.6.1.4.1.6431.1.1.3.3.1.1 |
bwAlarmThresholdIndexThis integer represents the index of an alarm threshold in the systemro Unsigned32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.1 |
bwAlarmThresholdNameThe name of an alarm or DEFAULT if the threshold applies to all alarms in the systemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6431.1.1.3.3.1.1.2 |
bwAlarmThresholdMaxNumTrapsPerTimePeriodThe maximum number of traps that the system outputs per sliding time period. If set to 0 (zero), the alarm is suppressed and the system does not output any trap for this alarm filter.rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.3 |
bwAlarmThresholdTimePeriodInSecondsThe time period used for threshold calculation, in seconds.rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.4 |
bwAlarmThresholdProblemTextVarNum1To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.5 |
bwAlarmThresholdProblemTextVarNum2To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.6 |
bwAlarmThresholdProblemTextVarNum3To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.7 |
bwAlarmThresholdProblemTextVarNum4To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.8 |
bwAlarmThresholdProblemTextVarNum5To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).rw Integer32 .1.3.6.1.4.1.6431.1.1.3.3.1.1.9 |
bwAlarmThresholdMinimumSeverityThis is the minimum alarm severity under which alarms start to be discarded.rw Enumeration .1.3.6.1.4.1.6431.1.1.3.3.1.1.10 |
bwAlarmThresholdControlThis scalar controls the life cycle of the threshold. Setting this threshold to create(3) using an unused index creates a row with the specified index. Setting it with an already used index has no effect. Setting this threshold to delete(2) removes the entry.rw Enumeration .1.3.6.1.4.1.6431.1.1.3.3.1.1.11 |
reservedModule OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.10 |
bwReservedScalarThis is a reserved counterro Enumeration .1.3.6.1.4.1.6431.1.1.10.1 |
bwMtcMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.20 |
bwMtcMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.20.1 |
bwMoServerGroupThis group defines managed object server attributes. Unknown .1.3.6.1.4.1.6431.1.1.20.1.1 |
bwMoSoftwareVersionsGroupThis group defines the software version attributes for the managed object. Unknown .1.3.6.1.4.1.6431.1.1.20.1.2 |
bwMoDeviceGroupThis group defines the counters used to manage the access or network devices monitored by this managed object. Unknown .1.3.6.1.4.1.6431.1.1.20.1.3 |
bwMoThresholdsGroupThis group defines the threshold control for this managed object. Unknown .1.3.6.1.4.1.6431.1.1.20.1.4 |
bwMoReserveGroupMIB reserved section. Unknown .1.3.6.1.4.1.6431.1.1.20.1.10 |
bwMtcMibCompliancy OBJECT IDENTIFIER .1.3.6.1.4.1.6431.1.1.20.2 |
bwMoBasicComplianceBroadWorks Common managed object MIB compliance Unknown .1.3.6.1.4.1.6431.1.1.20.2.1 |