Home/Catalog/Baytech-MIB-403-1

Baytech-MIB-403-1

AI MIB Summary

Standard SNMP MIB module defining data structures for Baytech-MIB-403-1.

261
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

261 total
Object Name
baytech
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779
RFC1213-MIB
Unknown
.1.3.6.1.4.1.4779
communicationLostSEVERE: Communication to the unit has been lost. Steps to reestablish communication are in progress. Argument is timeTicks when communication was lost.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.1
communicationEstablishedINFORMATION: Communication with the unit has been established. Argument is timeTicks when communication was established.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.2
outletOnWARNING: The specified RPC outlet has turned on. If sBTAOutletIndex equals zero, then all outlets have turned on.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.3
outletOffWARNING: The specified RPC outlet has turned off. If sBTAOutletIndex equals zero, then all outlets have turned off.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.4
outletRebootWARNING: The specified RPC outlet has rebooted. If sBTAOutletIndex equals zero, then all outlets have rebooted.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.5
outletLockedWARNING: The specified RPC outlet has been locked. If sBTAOutletIndex equals zero, then all outlets have been locked.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.6
outletUnlockedWARNING: The specified RPC outlet has been unlocked. If sBTAOutletIndex equals zero, then all outlets have been unlocked.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.7
configChangeSNMPWARNING: The SNMP configuration has been changed.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.8
configChangeOutletWARNING: The specified outlet has changed configuration.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.9
accessViolationConsoleWARNING: Someone has attempted to login via the console with the incorrect password.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.10
accessViolationNetworkWARNING: Someone has attempted to login via the network with the incorrect password.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.11
userPasswordChangeWARNING: The password for the specified user has been changed.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.12
userAddedWARNING: The specified user has been added.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.13
userLoggedInINFORMATIONAL: The specified user has logged in.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.14
temperatureThresholdViolationWARNING: A temperature threshold has been violated. The argument is the rpc index.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.15
temperatureThresholdViolationClearedINFORMATIONAL: A temperature threshold violated has been cleared. The argument is the rpc index.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.16
currentThresholdViolationWARNING: The preset current threshold has been violated. The argument is the rpc index.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.17
currentThresholdViolationClearedINFORMATIONAL: A current threshold violation has been cleared. The argument is the rpc index.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.18
resetModulesEventWARNING: A reset modules (RM) command has been executed.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.19
resetModulesCompleteWARNING: A reset modules (RM) command has been completed.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.20
errorExecutingSNMPCommandWARNING: unable to execute SNMP command. String contains reason and command.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.21
fileTransferCompleteINFORMATIONAL: file transfer to unit complete.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.22
userTerminatedWARNING: user terminated. Argument specifies user.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.23
voltageOverThresholdViolationWARNING: Over voltage. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.24
voltageOverThresholdViolationClearedINFORMATIONAL: Over voltage cleared. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.25
voltageUnderThresholdViolationWARNING: Under voltage. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.26
voltageUnderThresholdViolationClearedINFORMATIONAL: Under voltage cleared. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.27
circuitBreakerAlarmWARNING: Circuit breaker is blown. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.28
rpcFailureAlarmWARNING: Unable to communicate to an RPC. Argument specifies port number of RPC.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.29
userDeletedINFORMATIONAL: The specified user has logged in.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.30
warningThresholdViolation
TRAP-TYPE
.1.3.6.1.4.1.4779.0.31
warningThresholdViolationClear
TRAP-TYPE
.1.3.6.1.4.1.4779.0.32
emergencyThresholdViolation
TRAP-TYPE
.1.3.6.1.4.1.4779.0.33
emergencyThresholdViolationClear
TRAP-TYPE
.1.3.6.1.4.1.4779.0.34
circuitBreakerAlarmClearTrapCircuit breaker has been reset. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.35
currentUnderThresholdViolationWARNING: Low current. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.36
currentUnderThresholdViolationClearedINFORMATIONAL: Low current cleared. Argument specifies rpc.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.37
voltageSourceChangeAlarmWARNING: RPC voltage source has changed. Arguments specify modules index, current voltage source, and count of number of times source has been switched.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.38
sensorTempThreshHiAlarmTrapWARNING: Hi threshold exceeded. Arguments specify module, sensor number
TRAP-TYPE
.1.3.6.1.4.1.4779.0.39
sensorTempThreshHiAlarmClearedTrapWARNING: Hi threshold alarm cleared. Arguments specify module, sensor number
TRAP-TYPE
.1.3.6.1.4.1.4779.0.40
sensorTempThreshLoAlarmTrapWARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
TRAP-TYPE
.1.3.6.1.4.1.4779.0.41
sensorTempThreshLoAlarmClearedTrapWARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
TRAP-TYPE
.1.3.6.1.4.1.4779.0.42
sensorStateChangeTrapWARNING: Sensor state (contact, detector, etc) has changed. Arguments specify module, sensor number
TRAP-TYPE
.1.3.6.1.4.1.4779.0.43
configChangeSensorWARNING: The specified environmental sensor has changed configuration.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.44
sensorTypeChangeWARNING: The specified environmental sensor is now a different type.
TRAP-TYPE
.1.3.6.1.4.1.4779.0.45
btadevices
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1
sBTAIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.1
sBTAIdentFirmwareRevAn 8 byte ID string identifying the DS72 firmware revision. This value is set at the factory.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.1.1
sBTAIdentSerialNumberA number identifying the serial number of the DS72. This value is set at the factory.ro
INTEGER
.1.3.6.1.4.1.4779.1.1.2
sBTAIdentUnitNameA 64-character string identifying the name (UnitID) of the DS72. This value is set at the factory to a default of DS72.rw
DisplayString
.1.3.6.1.4.1.4779.1.1.3
sBTANetworkConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.2
sBTANetworkConfigBootpEnableEnables/disables bootp. Bootp will not take effect until the unit is reseted.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.1
sBTANetworkConfigDHCPEnableEnables/disables DHCP. DHCP will not take effect until the unit is reseted.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.2
sBTANetworkConfigSSHEnableEnables/disables SSH logins. Disable/enable SSH will take effect after the unit is reseted.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.3
sBTANetworkConfigTelnetEnableEnables/disables telnet.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.4
sBTANetworkConfigActivityTimeoutA value from 0 to 120. 0 disables activity timeouts. Value represents minutes of non-activity before telnet / SSH sessions are automatically logged out. Default is 0.rw
INTEGER
.1.3.6.1.4.1.4779.1.2.5
sBTANetworkConfigDirectConnEnableEnables/disables direct port connection upon login.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.6
sBTANetworkConfigSNMP
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.2.8
sBTANetworkConfigSNMPReadOnlyCommunityThe community name to use for read only access. Maximum len 16 bytes.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.2.8.1
sBTANetworkConfigSNMPReadWriteCommunityThe community name to use for read-write access. Maximum len 16 bytes.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.2.8.2
sBTANetworkConfigSNMPNumTrapReceiversThe maximum number of managers to send traps to. Currently 4.ro
INTEGER
.1.3.6.1.4.1.4779.1.2.8.3
sBTANetworkConfigSNMPTrapReceiverTableA list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four.
SEQUENCE OF SDSNetworkConfigSNMPTrapReceiverEntry
.1.3.6.1.4.1.4779.1.2.8.4
sBTANetworkConfigSNMPTrapReceiverEntryTable of managers to send traps to.
SDSNetworkConfigSNMPTrapReceiverEntry
.1.3.6.1.4.1.4779.1.2.8.4.1
trapIndexThe index to a trap receiver entry.ro
INTEGER
.1.3.6.1.4.1.4779.1.2.8.4.1.1
receiverAddressThe IP address of the manager to send traps to.rw
IpAddress
.1.3.6.1.4.1.4779.1.2.8.4.1.2
sBTANetworkConfigRadius
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.2.9
sBTANetworkConfigRadiusEnableEnables / disables RADIUS telnet logins.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.9.1
sBTANetworkConfigRadiusPrimaryServerIp address of the primary RADIUS server.rw
IpAddress
.1.3.6.1.4.1.4779.1.2.9.2
sBTANetworkConfigRadiusSecondaryServerIp address of the back-up RADIUS server.rw
IpAddress
.1.3.6.1.4.1.4779.1.2.9.3
sBTANetworkConfigRadiusLocalLoginEnables / disables the use of local (usernames stored in the DS72) logins in the case that both the primary and secondary RADIUS server are not available.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.9.4
sBTANetworkConfigWEB
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.2.10
sBTANetworkConfigWebEnableEnables WEB.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.10.1
sBTANetworkConfigWebSecureEnableEnables WEB Security.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.10.2
sBTANetworkConfigWebLoginEnableEnables WEB Login.rw
Enumeration
.1.3.6.1.4.1.4779.1.2.10.3
sBTANetworkConfigWebActivityTimeoutA value from 0 to 120. 0 disables WEB activity timeouts. Value represents minutes of non-activity before WEB sessions are automatically logged out. Default is 0.rw
INTEGER
.1.3.6.1.4.1.4779.1.2.10.4
sBTAModules
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.3
sBTAModulesNumberOfModulesNumber of modules installed into the DS unit.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.1
sBTAModulesModulesInstalledA character string listing the modules installed seperated by commas. Each module is identifed by a two digit number indicating the slot. For example 02,03,04,06 means modules 2,3,4 and 6 are installed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.2
sBTAModulesResetModulesCmdThis command is no longer supported.rodeprecated
INTEGER
.1.3.6.1.4.1.4779.1.3.3
sBTAModulesNumberOfIntelligentModulesThe number of Intelligent Modules installed in the DS Unit.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.4
sBTAModulesRPC
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.3.5
sBTAModulesNumberOfRPCModulesThe number of DS30 Modules installed in the DS Unit.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.1
sBTAModulesRPCTableAllows for control of individual outlets and individual RPC modules.
SEQUENCE OF SDSModulesRPCEntry
.1.3.6.1.4.1.4779.1.3.5.2
sBTAModulesRPCEntryThe RPCs to control and get status on.
SDSModulesRPCEntry
.1.3.6.1.4.1.4779.1.3.5.2.1
sBTAModulesRPCIndexThe index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula: ((module - 2) * 4) + port. For example module 3 port 1 = index 5.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.1
sBTAModulesRPCNameThe name (unit id) of the rpc.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.2.1.2
sBTAModulesRPCFirmwareVersionThe firware version of the rpc.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.2.1.3
sBTAModulesRPCCurrentThe current reading for the power strip. If current measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.4
sBTAModulesRPCMaxCurrentThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.5
sBTAModulesRPCVoltageThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.6
sBTAModulesRPCPowerThe power reading for the power strip. If power measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.7
sBTAModulesRPCTemperatureThe temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.8
sBTAModulesRPCRebootTimeoutThe length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.9
sBTAModulesRPCAllOutletsCmdTurns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot A get will return unknown (6).rw
Enumeration
.1.3.6.1.4.1.4779.1.3.5.2.1.10
sBTAModulesRPCAllOutletsStatusReports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked offro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.2.1.11
sBTAModulesRPCCurrentAlarmThresholdThe current alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.12
sBTAModulesRPCOverVoltageThresholdThe over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.13
sBTAModulesRPCUnderVoltageThresholdThe under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.14
sBTAModulesRPCNumberOfOutletsNumber of outlets for this RPC. This will be the size of outlet table for this RPC index.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.15
sBTAModulesRPCCircuitBreakerStatus of circuit breaker in power strip. 0=off 1=on.ro
Enumeration
.1.3.6.1.4.1.4779.1.3.5.2.1.16
sBTAModulesRPCOverTempThresholdThe over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.17
sBTAModulesRPCUnitVATotal Volt-Amps for this RPC.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.18
sBTAModulesRPCNumberOfBreakersNumber of breakers for this RPC.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.19
sBTAModulesRPCLowCurrentThresholdLow current threshold for this RPC.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.20
sBTAModulesRPCVoltageSourceVoltage source for this RPC.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.21
sBTAModulesRPCSourceSwitchCountCount of Voltage Source Switches for this RPC.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.22
sBTAModulesRPCNumberOfSensorsNumber of environmental sensors for this RPC.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.2.1.23
sBTAModulesRPCTypeThe type of RPC installed at the indexed location.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.2.1.24
sBTAModulesRPCOutletTableAllows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
SEQUENCE OF SDSModulesRPCOutletEntry
.1.3.6.1.4.1.4779.1.3.5.3
sBTAModulesRPCOutletEntryThe outlets to control and get status on.
SDSModulesRPCOutletEntry
.1.3.6.1.4.1.4779.1.3.5.3.1
sBTAModulesRPCOutletModuleIndexThe index to the outlet entry.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.3.1.1
sBTAModulesRPCOutletIndexThe index to the outlet entry.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.3.1.2
sBTAModulesRPCOutletStateGetting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.rw
Enumeration
.1.3.6.1.4.1.4779.1.3.5.3.1.3
sBTAModulesRPCOutletNameThe name of the outlet. Maximum size is 16 characters.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.3.1.4
sBTAModulesRPCGroupCmdA character string listing the outlets that need to be controlled, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.outlet. For example 2 2.1,2.12,3.1 will reboot module 2 outlet 2&12 module 3 outlet 1.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.4
sBTAModulesRPCModPortTableAllows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
SEQUENCE OF SDSModulesRPCModPortEntry
.1.3.6.1.4.1.4779.1.3.5.5
sBTAModulesRPCModPortEntryThe RPCs to control and get status on.
SDSModulesRPCModPortEntry
.1.3.6.1.4.1.4779.1.3.5.5.1
sRPCModuleIndexThe module number index into the RPC table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.1
sRPCPortIndexThe port number index into the RPC table. In the case of ds30 modules this number is always 1.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.2
sRPCTypeType of RPC at the module, port index.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.5.1.3
sRPCNameThe name (unit id) of the rpc module.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.5.1.4
sRPCFirmwareVersionThe firware version of the rpc module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.5.1.5
sRPCCurrentThe current reading for the power strip. If current measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.6
sRPCMaxCurrentThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.7
sRPCVoltageThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.8
sRPCPowerThe power reading for the power strip. If power measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.9
sRPCTemperatureThe temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.10
sRPCRebootTimeoutThe length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.11
sRPCAllOutletsCmdTurns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will return unknown (6).rw
Enumeration
.1.3.6.1.4.1.4779.1.3.5.5.1.12
sRPCAllOutletsStatusReports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked offro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.5.1.13
sRPCCurrentAlarmThresholdThe current alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.14
sRPCOverVoltageThresholdThe over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.15
sRPCUnderVoltageThresholdThe under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.16
sRPCNumberOfOutletsNumber of outlets for this RPC. This will be the size of outlet table for this RPC index.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.17
sRPCCircuitBreakerStatus of circuit breaker in power strip. 0=off 1=on.ro
Enumeration
.1.3.6.1.4.1.4779.1.3.5.5.1.18
sRPCOverTempThresholdThe over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.19
sRPCUnitVANumber of outlets for this RPC. This will be the size of outlet table for this RPC index.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.20
sRPCNumberOfBreakersNumber of breakers for this RPC.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.21
sRPCLowCurrentThresholdLow current threshold for this RPC.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.22
sRPCVoltageSourceVoltage source for this RPC.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.23
sRPCSourceSwitchCountVoltage source switch count for this RPC.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.24
sRPCNumberOfSensorsNumber of sensors for this RPC.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.5.1.25
sBTAModulesRPCModPortOutletTableAllows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
SEQUENCE OF SDSModulesRPCModPortOutletEntry
.1.3.6.1.4.1.4779.1.3.5.6
sBTAModulesRPCModPortOutletEntryThe outlets to control and get status on.
SDSModulesRPCModPortOutletEntry
.1.3.6.1.4.1.4779.1.3.5.6.1
sRPCOutletModuleIndexThe module index to the outlet entry.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.6.1.1
sRPCOutletPortIndexThe port index to the outlet entry. In the case of ds30s this number is always 1.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.6.1.2
sRPCOutletIndexThe outlet index to the outlet entry.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.6.1.3
sRPCOutletStateGetting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.rw
Enumeration
.1.3.6.1.4.1.4779.1.3.5.6.1.4
sRPCOutletNameThe name of the outlet. Maximum size is 16 characters.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.6.1.5
sBTAModulesRPCModPortGroupCmdA character string listing the outlets that need to be rebooted, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.port.outlet. For example 2 2.1.1,2.1.12,3.4.1 will reboot module 2 port 1 outlet 2&12 module 3 port 4 outlet 1.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.7
sBTAModulesRPCCurrentGroupsCurrentTableA list of total current for RPCs in each current group
SEQUENCE OF SDSModulesRPCCurrentGroupsCurrentEntry
.1.3.6.1.4.1.4779.1.3.5.8
sBTAModulesRPCCurrentGroupsCurrentEntryTable of total current measurement by group
SDSModulesRPCCurrentGroupsCurrentEntry
.1.3.6.1.4.1.4779.1.3.5.8.1
groupCurrentIndexThe index to a group total current.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.8.1.1
groupCurrentCurrent total for all RPCs in group.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.8.1.2
rpcGroupA character string listing the RPCs, by port index, that will be included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to warning and emergency thresholds, generating appropriate traps as required by transit of a threshold. A maximum of 8 RPCs may be monitored within a group. The RPC must be connected and operating and the corresponding DS74 serial port must be configured for an RPC-SNMP device type to be allowed group membership.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.8.1.3
warningThresholdThe current level, in tenths of an amp, that will cause a Current Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent whent the total group current falls below the threshold.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.8.1.4
emergencyThresholdThe current level, in tenths of an amp, that will cause a Current Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sent whent the total group current falls below the threshold.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.8.1.5
sBTAModulesRPCBreakersTableAllows monitoring of individual outlet strips on RPCs.
SEQUENCE OF SDSModulesRPCBreakersEntry
.1.3.6.1.4.1.4779.1.3.5.9
sBTAModulesRPCBreakersEntryStatus organization by breaker.
SDSModulesRPCBreakersEntry
.1.3.6.1.4.1.4779.1.3.5.9.1
sBTAModulesRPCBreakersModulesIndexThe index into the RPC table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.1
sBTAModulesRPCBreakersBreakersIndexThe index into the RPC breaker table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.2
sBTAModulesRPCBreakersCircuitBreakerStatus of circuit breaker in power strip. 0=off 1=on.ro
Enumeration
.1.3.6.1.4.1.4779.1.3.5.9.1.3
sBTAModulesRPCBreakersCurrentThe detected current reading for the power strip. If current measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.4
sBTAModulesRPCBreakersMaxCurrentThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.5
sBTAModulesRPCBreakersVoltageThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.6
sBTAModulesRPCBreakersPowerThe power reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.7
sBTAModulesRPCBreakersVAThe volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.8
sBTAModulesRPCBreakersCurrentAlarmThresholdThe current alarm threshold level *10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.9.1.9
sRPCModPortBreakersTableAllows monitoring of individual outlet strips on RPCs.
SEQUENCE OF SRPCModPortBreakersEntry
.1.3.6.1.4.1.4779.1.3.5.10
sRPCModPortBreakersEntryStatus organization by breaker.
SRPCModPortBreakersEntry
.1.3.6.1.4.1.4779.1.3.5.10.1
sRPCBreakersModIndexThe module index into the RPC breaker table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.1
sRPCBreakersPortIndexThe port index into the RPC breaker table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.2
sRPCBreakersBreakersIndexThe breaker index into the RPC breaker table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.3
sRPCBreakersCircuitBreakerStatus of circuit breaker in power strip. 0=off 1=on.ro
Enumeration
.1.3.6.1.4.1.4779.1.3.5.10.1.4
sRPCBreakersCurrentThe detected current reading for the power strip. If current measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.5
sRPCBreakersMaxCurrentThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.6
sRPCBreakersVoltageThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.7
sRPCBreakersPowerThe power reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.8
sRPCBreakersVAThe volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.9
sRPCBreakersCurrentAlarmThresholdThe current alarm threshold level x10. A value of 105 will set the level to 10.5.rw
INTEGER
.1.3.6.1.4.1.4779.1.3.5.10.1.10
sRPCOutletGroupTableAllows control of outlets via a group of up to four outlets.
SEQUENCE OF SRPCOutletGroupEntry
.1.3.6.1.4.1.4779.1.3.5.11
sRPCOutletGroupEntryOrganized by group number.
SRPCOutletGroupEntry
.1.3.6.1.4.1.4779.1.3.5.11.1
sRPCOutletGroupIndexThe index into the outlet group table.ro
INTEGER
.1.3.6.1.4.1.4779.1.3.5.11.1.1
sRPCOutletGroupNameThe name of the outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.11.1.2
sRPCOutletGroupOutletsThe list of outlets in the outlet group. Format is mod.port.outlet,mod.port.outlet up to 4 outlets.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.3.5.11.1.3
sRPCOutletGroupCmdCommand for outlet group. Same rules as rpc commands.rw
Enumeration
.1.3.6.1.4.1.4779.1.3.5.11.1.4
sBTAModulesSerial
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.3.6
sBTAModulesModem
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.3.7
sBTAControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.4
sBTAControlResetUnitSetting this value to 1 will cause the unit to reset. A get of this OID will return 0.rw
Enumeration
.1.3.6.1.4.1.4779.1.4.1
sBTAControlResetModulesSetting this value to 1 will cause the unit to reset modules simular to the telnet RM command. A get of this OID will return 0.rw
Enumeration
.1.3.6.1.4.1.4779.1.4.2
sBTAControlNumOfLoggedUsersNumber of users logged in via telnet or SSH.ro
INTEGER
.1.3.6.1.4.1.4779.1.4.3
sBTAControlUserTableA list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
SEQUENCE OF SDSControlUserEntry
.1.3.6.1.4.1.4779.1.4.4
sBTAControlUserEntryThe users to get status on.
SDSControlUserEntry
.1.3.6.1.4.1.4779.1.4.4.1
sBTAControlUserIndexThe index to the user entry.ro
INTEGER
.1.3.6.1.4.1.4779.1.4.4.1.1
sBTAControlUserNameThe username of the user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.4.4.1.2
sBTAControlUserAddressThe IP address of the user.ro
IpAddress
.1.3.6.1.4.1.4779.1.4.4.1.3
sBTAControlUserConnectionType of connection. If unknown, user is logging out or the connection is invalid.ro
Enumeration
.1.3.6.1.4.1.4779.1.4.4.1.4
sBTAControlUserConnModuleIf the user is connected to a module, this value will report the module number connected to. If the value is 0 the user is not connected to a module.ro
INTEGER
.1.3.6.1.4.1.4779.1.4.4.1.5
sBTAControlUserConnPortThe port number with in a module that the user is connected to. This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not connected to a module.ro
INTEGER
.1.3.6.1.4.1.4779.1.4.4.1.6
sBTAControlUserTerminateUserSettings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.rw
Enumeration
.1.3.6.1.4.1.4779.1.4.4.1.7
sBTAFileTransfer
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.5
sBTAFileTransferEnableUpgradeFTPFileTransferSetting this OID to enableUpgradeFileTransferDownloadViaFTP (1) will start the FTP server and place the DS72 in upgrade mode. An FTP connection may then be established for the purpose of transmitting a firmware upgrade file.rw
Enumeration
.1.3.6.1.4.1.4779.1.5.1
sBTAEnvironmental
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.1.6
sBTAModulesEnvironmentalObjectsTableAllows monitoring of individual outlet strips on RPCs.
SEQUENCE OF SDSModulesEnvironmentalObjectsEntry
.1.3.6.1.4.1.4779.1.6.1
sBTAModulesEnvironmentalObjectsEntryStatus organization by sensor.
SDSModulesEnvironmentalObjectsEntry
.1.3.6.1.4.1.4779.1.6.1.1
sBTAModulesEnvironmentalModulesIndexModule Index for Environemntal tablero
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.1
sBTAModulesEnvironmentalSensorsIndexSensor Index for Environemntal tablero
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.2
sBTAModulesEnvironmentalTypeEnvironmental Object Type.ro
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.3
sBTAModulesEnvironmentalNameThe name for the environmental object.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.6.1.1.4
sBTAModulesEnvironmentalMeasurementThe measurement or state for the object.ro
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.5
sBTAModulesEnvironmentalHiThresholdHi threshold for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.6
sBTAModulesEnvironmentalLoThresholdLo threshold for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.7
sBTAModulesEnvironmentalMaxMax value recorded for object since last reset.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.8
sBTAModulesEnvironmentalMinMin value recorded for object since last reset.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.9
sBTAModulesEnvironmentalHiThresholdEnHi threshold enable for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.10
sBTAModulesEnvironmentalLoThresholdEnLo threshold enable for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.11
sBTAModulesEnvironmentalStateTrapEnTrap enable for environmental sensors with contacts.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.1.1.12
sRPCEnvironmentalObjectsTableAllows monitoring of individual outlet strips on RPCs.
SEQUENCE OF SRPCEnvironmentalObjectsEntry
.1.3.6.1.4.1.4779.1.6.2
sRPCEnvironmentalObjectsEntryStatus organization by sensor.
SRPCEnvironmentalObjectsEntry
.1.3.6.1.4.1.4779.1.6.2.1
sRPCEnvironmentalModuleIndexModule Index for Environemntal tablero
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.1
sRPCEnvironmentalPortIndexPort Index for Environemntal tablero
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.2
sRPCEnvironmentalSensorsIndexSensor Index for Environemntal tablero
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.3
sRPCEnvironmentalTypeEnvironmental Object Type.ro
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.4
sRPCEnvironmentalNameThe name for the environmental object.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.1.6.2.1.5
sRPCEnvironmentalMeasurementThe measurement or state for the object.ro
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.6
sRPCEnvironmentalHiThresholdHi threshold for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.7
sRPCEnvironmentalLoThresholdLo threshold for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.8
sRPCEnvironmentalMaxMax value recorded for object since last reset.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.9
sRPCEnvironmentalMinMin value recorded for object since last reset.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.10
sRPCEnvironmentalHiThresholdEnHi threshold enable for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.11
sRPCEnvironmentalLoThresholdEnLo threshold enable for object.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.12
sRPCEnvironmentalStateTrapEnTrap enable for environmental sensors with contacts.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.2.1.13
sBTAEnvironmentalAllTemperatureSensorsHiThresholdHi Threshold for all temperature sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.3
sBTAEnvironmentalAllTemperatureSensorsLoThresholdLo Threshold for all temperature sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.4
sBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnableHi Threshold trap enable for all temperature sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.5
sBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnableLo Threshold trap enable for all temperature sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.6
sBTAEnvironmentalAllSensorsStateTrapEnableState change environmental sensor (ex: contact) trap enable.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.7
sBTAEnvironmentalAllHumiditySensorsHiThresholdHi Threshold for all humidity sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.8
sBTAEnvironmentalAllHumiditySensorsLoThresholdLo Threshold for all humidity sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.9
sBTAEnvironmentalAllHumiditySensorsHiThresholdTrapEnableHi Threshold trap enable for all humidity sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.10
sBTAEnvironmentalAllHumiditySensorsLoThresholdTrapEnableLo Threshold trap enable for all humidity sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.11
sBTAEnvironmentalAllAirflowSensorsHiThresholdHi Threshold for all airflow sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.12
sBTAEnvironmentalAllAirflowSensorsLoThresholdLo Threshold for all airflow sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.13
sBTAEnvironmentalAllAirflowSensorsHiThresholdTrapEnableHi Threshold trap enable for all airflow sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.14
sBTAEnvironmentalAllAirflowSensorsLoThresholdTrapEnableLo Threshold trap enable for all airflow sensors.rw
INTEGER
.1.3.6.1.4.1.4779.1.6.15
mtrapargs
OBJECT IDENTIFIER
.1.3.6.1.4.1.4779.3
mtrapargsIntegerThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.1
mtrapargsIpAddressThis OID allows bayteh traps to be sent with an IP address argument that may not be defined in the baytech MIB. A get of this OID will return 0.0.0.0.ro
IpAddress
.1.3.6.1.4.1.4779.3.2
mtrapargsStringThis OID allows baytech traps to be sent with an octet string argument that may not be defined in the baytech MIB. A get of this OID will return a NULL string.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4779.3.3
mtrapargsGaugeThis OID allows baytech traps to be sent with a Gauge argument that may not be defined in the baytech MIB. A get of this OID will return 0.ro
Gauge
.1.3.6.1.4.1.4779.3.4
mtrapargsTimeTicksThis OID allows baytech traps to be sent with a TimeTicks argument that may not be defined in the baytech MIB. A get of this OID will return 0.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.4779.3.5
sBTAModuleIndexThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific DS module. Value will equal the slot of the module. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.6
sBTAOutletIndexThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.7
sBTAPortIndexThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.8
sBTAVoltageSourceThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the voltage source in an RPC. Value is 1 or 2, depending on which voltage source is powering the RPC. A get of this OID will return 0.rw
INTEGER
.1.3.6.1.4.1.4779.3.9
sBTASourceSwitchCountThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the number of voltage source transitions in an RPC. Value is 0 to 255, an 8-bit w/rollover count of number of times voltage source has been switched from one source to another. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.10
sBTASensorIndexThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific sensor in a DS module. Value is 1 to number of sensors controlled by the ds module. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.11
sBTABreakerIndexThis is an object which is sent along with a trap to designate a breaker number pertinent to a particular trap. This value will range from 1 to the total number of breakers inside the particular RPC. A get of this OID will return 0.ro
INTEGER
.1.3.6.1.4.1.4779.3.12
Baytech-MIB-403-1 - SNMP MIB Reference | MIBs Explorer