BRWAVE-RADIO-MIB
The BRWAVE-RADIO-MIB module enables monitoring and management of Broadcom Wave radio hardware interfaces, specifically tracking RF link status, signal strength, channel utilization, and transmission statistics for wireless access points and radio modules.
Imported Objects
Objects
62 total| Object Name |
|---|
bridgeWave OBJECT IDENTIFIER .1.3.6.1.4.1.6080 |
brwaveReg OBJECT IDENTIFIER .1.3.6.1.4.1.6080.1 |
brwaveMibs OBJECT IDENTIFIER .1.3.6.1.4.1.6080.1.1 |
brwaveRadioMibModule MODULE-IDENTITY .1.3.6.1.4.1.6080.1.1.3 |
brwaveModules OBJECT IDENTIFIER .1.3.6.1.4.1.6080.1.2 |
brwaveRadioFE60 OBJECT IDENTIFIER .1.3.6.1.4.1.6080.1.2.1 |
brwaveRadioGE60 OBJECT IDENTIFIER .1.3.6.1.4.1.6080.1.2.2 |
brwaveRadioAR60 OBJECT IDENTIFIER .1.3.6.1.4.1.6080.1.2.3 |
brwaveCommon OBJECT IDENTIFIER .1.3.6.1.4.1.6080.2 |
brwaveRadioSnro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6080.2.1 |
brwaveUnitModelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6080.2.2 |
brwaveBbSnro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6080.2.3 |
brwaveIfSnro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6080.2.4 |
brwaveMmwSnro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6080.2.5 |
brwaveTrapCountro Unsigned32 .1.3.6.1.4.1.6080.2.6 |
brwaveProducts OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3 |
brwaveRadio OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1 |
brwaveRadioFactorySetup OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.2 |
brwaveRadioTxBandro Enumeration .1.3.6.1.4.1.6080.3.1.2.1 |
brwaveRadioFactoryRatero Enumeration .1.3.6.1.4.1.6080.3.1.2.3 |
brwaveRadioClearStatsrw Integer32 .1.3.6.1.4.1.6080.3.1.2.4 |
brwaveRadioStatus OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.3 |
brwaveRadioInVoltagero Integer32 .1.3.6.1.4.1.6080.3.1.3.1 |
brwaveRadioUnitTemperaturero Integer32 .1.3.6.1.4.1.6080.3.1.3.2 |
brwaveRadioTxTemperaturero Integer32 .1.3.6.1.4.1.6080.3.1.3.3 |
brwaveRadioRSLro Integer32 .1.3.6.1.4.1.6080.3.1.3.4 |
brwaveRadioRSLVoltagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6080.3.1.3.5 |
brwaveRadioAbsRSLro Integer32 .1.3.6.1.4.1.6080.3.1.3.6 |
brwaveRadioRSLVoltageIntro Integer32 .1.3.6.1.4.1.6080.3.1.3.7 |
brwaveCopperUtilizationro Integer32 .1.3.6.1.4.1.6080.3.1.3.8 |
brwaveFiberUtilizationro Integer32 .1.3.6.1.4.1.6080.3.1.3.9 |
brwaveRadioUtilizationro Integer32 .1.3.6.1.4.1.6080.3.1.3.10 |
brwaveRadioFecErrorro Enumeration .1.3.6.1.4.1.6080.3.1.3.11 |
brwaveRadioPreFecFlagro Integer32 .1.3.6.1.4.1.6080.3.1.3.12 |
brwaveRadioPostFecFlagro Integer32 .1.3.6.1.4.1.6080.3.1.3.13 |
brwaveRadioLinkRatero Integer32 .1.3.6.1.4.1.6080.3.1.3.14 |
brwaveRadioEvents OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.9 |
brwaveRadioEventsV2 OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.9.0 |
brwaveErrorsOverThreshold NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.1 |
brwaveErrorsUnderThreshold NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.2 |
brwaveUnitTemperatureAbnormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.3 |
brwaveUnitTemperatureNormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.4 |
brwaveTxTemperatureAbnormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.5 |
brwaveTxTemperatureNormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.6 |
brwaveInputVoltageAbnormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.7 |
brwaveInputVoltageNormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.8 |
brwaveRslNormal NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.10 |
brwaveRslMinor NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.11 |
brwaveRslMajor NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.13 |
brwaveConfigChange NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.26 |
brwaveLoginSuccessfull NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.27 |
brwaveGeToFeSwitch NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.28 |
brwaveFeToGeSwitch NOTIFICATION-TYPE .1.3.6.1.4.1.6080.3.1.9.0.29 |
brwaveRadioTrapObjs OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.9.1 |
managerIPro OCTET STRING .1.3.6.1.4.1.6080.3.1.9.1.1 |
userNamero OCTET STRING .1.3.6.1.4.1.6080.3.1.9.1.2 |
brwaveConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.10 |
brwaveRadioGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.10.1 |
brwaveCommonGroup Unknown .1.3.6.1.4.1.6080.3.1.10.1.1 |
brwaveFactoryGroup Unknown .1.3.6.1.4.1.6080.3.1.10.1.2 |
brwaveStatusGroup Unknown .1.3.6.1.4.1.6080.3.1.10.1.3 |
brwaveCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6080.3.1.10.2 |
BRWAVE-RADIO-MIB Technical Reference Overview
The BRWAVE-RADIO-MIB SNMP MIB module published by BridgeWave defines 62 managed OID objects, including 28 scalar/column metrics, 0 SNMP tables, and 15 trap/notification events anchored at base OID .1.3.6.1.4.1.6080.1.1.3. Monitored SNMP traps/notifications include brwaveConfigChange, brwaveErrorsOverThreshold, brwaveErrorsUnderThreshold, brwaveFeToGeSwitch, brwaveGeToFeSwitch, brwaveInputVoltageAbnormal.
Key OID Definitions in BRWAVE-RADIO-MIB
.1.3.6.1.4.1.6080.1.1.3Radio MIB module.
.1.3.6.1.4.1.6080.3.1.9.0.26Configuration changes are performed by WEB client.
.1.3.6.1.4.1.6080.3.1.9.0.1Link has error rate over threshold.
.1.3.6.1.4.1.6080.3.1.9.0.2Link error rate changed from over to under threshold .
.1.3.6.1.4.1.6080.3.1.9.0.29Tx Rate switched from FE to GE.
.1.3.6.1.4.1.6080.3.1.9.0.28Tx Rate switched from GE to FE.
.1.3.6.1.4.1.6080.3.1.9.0.7Unit's input voltage is not in normal range. Normal input voltage > 16 Volts.
.1.3.6.1.4.1.6080.3.1.9.0.8Unit's input voltage is restored to normal range.
.1.3.6.1.4.1.6080.3.1.9.0.27NMS Loged in successfully.
.1.3.6.1.4.1.6080.3.1.9.0.13RSL droppped to the level of major event. RSL < -59.00 dBm (GE Radio) or RSL < -65 dBm (FE radio).
.1.3.6.1.4.1.6080.3.1.9.0.11Received Signal Leve droped to the level of minor event. RSL from -55.00 to -59.00 dBm (GE Radio) RSL from -59.00 to -65.00 dBm (FE radio).
.1.3.6.1.4.1.6080.3.1.9.0.10Received Signal Level is normal. Normal signal level RSL > -55.00 dBm (Gigabit) and RSL > -59.00 dBm (Fast Ethernet).
.1.3.6.1.4.1.6080.3.1.9.0.5Transmitter temperature is not in normal operating range. Normal range is: -20 to +75 degree Centigrade.
.1.3.6.1.4.1.6080.3.1.9.0.6Transmitter temperature is restored to normal range.
.1.3.6.1.4.1.6080.3.1.9.0.3Radio unit temperature not in normal operating range. Normal range is: -20 to +75 degree Centigrade.
.1.3.6.1.4.1.6080.3.1.9.0.4Unit temperature restores from abnormal to normal range.
.1.3.6.1.4.1.6080.2.3Base Band hardware serial number
.1.3.6.1.4.1.6080.3.1.10.1.1Collection of common objects.
.1.3.6.1.4.1.6080.3.1.3.8Link utilization calculated every polling interval.
.1.3.6.1.4.1.6080.3.1.10.1.2Collection of factory setup objects.
.1.3.6.1.4.1.6080.3.1.3.9Link utilization calculated every polling interval.
.1.3.6.1.4.1.6080.2.4IF hardware serial number
.1.3.6.1.4.1.6080.2.5MMW Hardware serial number
.1.3.6.1.4.1.6080.3.1.3.6Received Signal Level. The signal level of the received radio frequency in dBm x 100