BATM-DRY-CONTACTS-MIB
The BATM-DRY-CONTACTS-MIB defines managed objects and notifications for monitoring the state of external dry-contact alarm inputs on network hardware. It enables the polling of contact closure status and the generation of SNMP traps to alert management systems when physical alarm sensors trigger.
Imported Objects
Objects
15 total| Object Name |
|---|
batmDryContactsMIBInitial version. This MIB provides external-alarm management and notifications MODULE-IDENTITY .1.3.6.1.4.1.738.1.5.112 |
dryContactsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.112.1 |
inputsCfgTableA table containing inputs configuration and statuses SEQUENCE OF InputsCfgEntry .1.3.6.1.4.1.738.1.5.112.1.1 |
inputsCfgEntry InputsCfgEntry .1.3.6.1.4.1.738.1.5.112.1.1.1 |
extAlarmIDExternal alarm index uniquely identifies this row.
An integer with supported range of values 1-4. Index. Not-accessiblero INTEGER .1.3.6.1.4.1.738.1.5.112.1.1.1.1 |
nameName of alarm. An OCTET-STRING with max. 16 OCTETS.
Default value null string. Read-writerw OCTET STRING .1.3.6.1.4.1.738.1.5.112.1.1.1.2 |
descriptionAlarm description. An OCTET-STRING with max. 64 OCTETS.
Default value null string. Read-writerw OCTET STRING .1.3.6.1.4.1.738.1.5.112.1.1.1.3 |
enableStatusSenging alarms status. An enumeration with two values: enabled(1), disabled(2).
Default value is disabled(2). Read-writerw Enumeration .1.3.6.1.4.1.738.1.5.112.1.1.1.4 |
alarmStatusAlarm status. An enumeration with two values: no-alarm(1), alarm(2).
Default value is no-alarm(1). Read-only.ro Enumeration .1.3.6.1.4.1.738.1.5.112.1.1.1.5 |
alarmSeverityConfigured alarm severity. An enumeration with 4 values:
info(1), minor(2), major(3) and critical(4).
Default value is info(1). Read-writerw Enumeration .1.3.6.1.4.1.738.1.5.112.1.1.1.6 |
polarityConfigured polarity.
An enumeration with 2 values: normally-opened(1), normally-closed(2).
Default value is normally-opened(1). Read-writerw Enumeration .1.3.6.1.4.1.738.1.5.112.1.1.1.7 |
lastChangeThe value of sysUpTime at the time of the last operational status change.
TimeTicks. Read-onlyro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.738.1.5.112.1.1.1.8 |
dryContactsNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.112.2 |
inputStateChanged OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.112.2.1 |
inputStateChangedTrapSend notification when operational status of the input changes NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.112.2.1.1 |
More MIBs from BATM Advanced Communication
Browse all BATM Advanced CommunicationMIBs →SNMP MIB module
The PRVT-HQOS-MIB provides vendor-specific SNMP access to configure and monitor hierarchical Quality of Service (HQoS) parameters, including traffic class definitions, queue scheduling policies, and bandwidth allocation limits on network devices. This module enables granular control over packet prioritization, shaping, and policing mechanisms across multiple traffic levels to enforce service level agreements.
The PRVT-MPLS-TE-MIB module enables the monitoring and management of MPLS Traffic Engineering Label Switched Paths (LSPs) by exposing RSVP-TE and Constraint-Based LDP tunnel attributes, including bandwidth reservations, explicit route objects, and LSP state transitions. It facilitates the collection of operational metrics such as tunnel setup status, resource utilization, and constraint violations to support network capacity planning and fault isolation within MPLS core infrastructures.
SNMP MIB module
The PRVT-SWITCH-ACCESS-LIST-MIB module provides programmatic management of Layer 3 switch access control list (ACL) parameters, enabling the configuration and monitoring of packet filtering rules, rule ordering, and hit counters on private network switches.
PRVT-SWITCH-MIB provides the management interface for private switch hardware parameters, enabling the monitoring of port states, traffic counters, and configuration attributes via SNMP. This module facilitates the collection of operational metrics required for switch performance analysis and fault isolation in private network environments.