BARIX-ABCL-TRAPS-MIB
Standard SNMP MIB module defining data structures for BARIX-ABCL-TRAPS-MIB.
Imported Objects
Objects
9 total| Object Name |
|---|
BARIX-MIB TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1 |
amplifier1AlarmCleared TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1000 |
amplifier1Alarm TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1001 |
amplifier2AlarmCleared TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1002 |
amplifier2Alarm TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1003 |
partnerMissingCleared TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1004 |
partnerMissing TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1005 |
noAudioCleared TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1006 |
noAudio TRAP-TYPE .1.3.6.1.4.1.17491.1.5.0.1007 |
BARIX-ABCL-TRAPS-MIB Technical Reference Overview
The BARIX-ABCL-TRAPS-MIB SNMP MIB module published by Barix defines 9 managed OID objects, including 0 scalar/column metrics, 0 SNMP tables, and 9 trap/notification events. Monitored SNMP traps/notifications include BARIX-MIB, amplifier1AlarmCleared, amplifier1Alarm, amplifier2AlarmCleared, amplifier2Alarm, partnerMissingCleared.
Key OID Definitions in BARIX-ABCL-TRAPS-MIB
.1.3.6.1.4.1.17491.1.5.0.1A keepalive trap signalises that the system is still alive.
.1.3.6.1.4.1.17491.1.5.0.1000An amplifier1AlarmCleared trap signalises end of error condition 'Amplifier 1 Alarm' and is sent when the amplifier error of the first amplifier is resolved (the respective digital input is inactive). The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1001An amplifier1Alarm trap signalises an alarm condition on the first amplifier. The trap is triggered by activity on the respective digital input. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1002An amplifier2AlarmCleared trap signalises end of error condition 'Amplifier 2 Alarm' and is sent when the amplifier error of the second amplifier is resolved (the respective digital input is inactive). The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1003An amplifier2Alarm trap signalises an alarm condition on the second amplifier. The trap is triggered by activity on the respective digital input. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1004A partnerMissingCleared trap signalises end of error condition 'Partner Missing' and is sent when the respective partner comes on-line. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1005A partnerMissing trap signalises a loss of the communication partner. The trap is sent only once when the partner is not responding for more than 60 seconds. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1006A noAudioCleared trap signalises end of error condition 'No Audio' and is sent when the output audio level raises above the minimum level. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.
.1.3.6.1.4.1.17491.1.5.0.1007A noAudio trap is sent if the audio output peak level is too low for a certain (configured) period of time while a valid audio stream is being received. This condition signalises a potential error in analog circuitry. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.