BARIX-ABCL-TRAPS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for BARIX-ABCL-TRAPS-MIB.

9
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

9 total
Object Name
BARIX-MIB
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1
amplifier1AlarmCleared
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1000
amplifier1Alarm
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1001
amplifier2AlarmCleared
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1002
amplifier2Alarm
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1003
partnerMissingCleared
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1004
partnerMissing
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1005
noAudioCleared
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1006
noAudio
TRAP-TYPE
.1.3.6.1.4.1.17491.1.5.0.1007

BARIX-ABCL-TRAPS-MIB Technical Reference Overview

The BARIX-ABCL-TRAPS-MIB SNMP MIB module published by Barix defines 9 managed OID objects, including 0 scalar/column metrics, 0 SNMP tables, and 9 trap/notification events. Monitored SNMP traps/notifications include BARIX-MIB, amplifier1AlarmCleared, amplifier1Alarm, amplifier2AlarmCleared, amplifier2Alarm, partnerMissingCleared.

Key OID Definitions in BARIX-ABCL-TRAPS-MIB

BARIX-MIBTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1

A keepalive trap signalises that the system is still alive.

amplifier1AlarmClearedTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1000

An amplifier1AlarmCleared trap signalises end of error condition 'Amplifier 1 Alarm' and is sent when the amplifier error of the first amplifier is resolved (the respective digital input is inactive). The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

amplifier1AlarmTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1001

An amplifier1Alarm trap signalises an alarm condition on the first amplifier. The trap is triggered by activity on the respective digital input. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

amplifier2AlarmClearedTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1002

An amplifier2AlarmCleared trap signalises end of error condition 'Amplifier 2 Alarm' and is sent when the amplifier error of the second amplifier is resolved (the respective digital input is inactive). The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

amplifier2AlarmTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1003

An amplifier2Alarm trap signalises an alarm condition on the second amplifier. The trap is triggered by activity on the respective digital input. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

partnerMissingClearedTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1004

A partnerMissingCleared trap signalises end of error condition 'Partner Missing' and is sent when the respective partner comes on-line. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

partnerMissingTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1005

A partnerMissing trap signalises a loss of the communication partner. The trap is sent only once when the partner is not responding for more than 60 seconds. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

noAudioClearedTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1006

A noAudioCleared trap signalises end of error condition 'No Audio' and is sent when the output audio level raises above the minimum level. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

noAudioTRAP-TYPEnot-accessible
.1.3.6.1.4.1.17491.1.5.0.1007

A noAudio trap is sent if the audio output peak level is too low for a certain (configured) period of time while a valid audio stream is being received. This condition signalises a potential error in analog circuitry. The details of the alert are sent as general purpose text strings that contain the following information in the given order: Human readable timestamp of the alarm, alarm severity, textual host name and a textual alarm description.

More MIBs from Barix