Amperion-MIB
AI MIB Summary
The Amperion-MIB provides vendor-specific SNMP access for Amperion Inc. network infrastructure, enabling the monitoring of proprietary device metrics such as power consumption, thermal status, and interface statistics. This private MIB extension facilitates granular management of Amperion hardware components that are not covered by standard IETF MIBs.
Amperion Inc. private MIB
Main OID:
amperion.1.3.6.1.4.1.13995
277
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
277 total| Object Name |
|---|
amperionAmperion Inc. private MIB MODULE-IDENTITY .1.3.6.1.4.1.13995 |
ds2 OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1 |
powerline OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1 |
plMibIIExtension OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.1 |
plCards OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.1.2 |
plCdNumberNumber of Cards available. Maximum index of plCdTablero Integer32 .1.3.6.1.4.1.13995.1.1.1.2.1 |
plCdTablePowerline Cards Table. List of attributes of each Card available in the System. Indexed by the number of the Card (from 1 to plCdNumber). SEQUENCE OF PlCdEntry .1.3.6.1.4.1.13995.1.1.1.2.2 |
plCdEntryRow of table plCdTable PlCdEntry .1.3.6.1.4.1.13995.1.1.1.2.2.1 |
plCdIndexNumber of powerline card. Maximum: plCdNumber Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.1 |
plCdTypeType of card:
0 => HE
1 => CPEro Enumeration .1.3.6.1.4.1.13995.1.1.1.2.2.1.2 |
plCdLinkType of link:
1 => Link 1
2 => Link 2
3 => Link 3
4 => Link 4
5 => Link 5
6 => Link 6rw Enumeration .1.3.6.1.4.1.13995.1.1.1.2.2.1.3 |
plCdShortMacAddressShort MAC Address of the Cardrw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.4 |
plCdLongMacAddressLong MAC Address of the Cardro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.5 |
plCdHardwareVersionHardware Versionro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.6 |
plCdFirmwareVersionFirmware Versionro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.7 |
plCdDriverVersionDriver Versionro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.8 |
plCdResetReset to Saved Values. Soft Reset.rw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.9 |
plCdFactoryResetReset to factory values. Hard Reset.rw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.10 |
plCdSaveAsPermanentSave MIB values as default values: the information of the Remote List (long MAC address and short MAC address of each user) is saved and will be restored after a reboot or a poweroff.rw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.11 |
plCdStatusStatus related to the interface:
0 => OK.ro Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.12 |
plCdRemoteListList of Long MAC Address that can be connected with HE (only HE). Returns a string with the list of long MAC address (not separated by spaces)ro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.13 |
plCdNumRemoteListNumber of CPE in remote list (only HE). This is the maximum value for cpeId in Network table.ro Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.14 |
plNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.2 |
plNetTableNetwork Topology. Indexed by number of card and number of remote user (.plCdIndex.cpeId). Maximum values for indexes: plCdNumber and plCdNumRemoteList. Only available in HE. SEQUENCE OF PlNetEntry .1.3.6.1.4.1.13995.1.1.2.1 |
plNetEntryRow of table plNetTable PlNetEntry .1.3.6.1.4.1.13995.1.1.2.1.1 |
plNetShortMacAddressSMAC of remote CPE. Integer32 .1.3.6.1.4.1.13995.1.1.2.1.1.1 |
plNetLongMacAddressLong Mac Address of Remote Node.rw DisplayString .1.3.6.1.4.1.13995.1.1.2.1.1.3 |
plNetRowStatusRow Statusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13995.1.1.2.1.1.8 |
plTransmission OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.3 |
plInpTableInput Channel Table. Common input characteristics.
Indexed by number of card.
Maximum value of index: plCdNumber SEQUENCE OF PlInpEntry .1.3.6.1.4.1.13995.1.1.3.2 |
plInpEntryRow of table plInpTable PlInpEntry .1.3.6.1.4.1.13995.1.1.3.2.1 |
plInpTotalOctetsTotal number of rx octets (including FEC overhead)ro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.1 |
plInpGainReception gainrw Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.2 |
plInpAGCTo enable or disable Adaptive Rx Gain Control.
0 => AGC disabled
1 => AGC enabled.rw Enumeration .1.3.6.1.4.1.13995.1.1.3.2.1.3 |
plInpMaxGainMaximum reception gainrw Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.4 |
plInpThresholdsSNR Thresholds in dB. Returns a string containing 4 integers.rw DisplayString .1.3.6.1.4.1.13995.1.1.3.2.1.5 |
plInpAttenuationGainAttenuation Gain (only HE)rw Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.6 |
plInpSamsDecodeNumber of decoded SAMS (only CPE)ro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.7 |
plInpSamsGoodNumber of used SAMS (only CPE)ro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.8 |
plInpSamsBadNumber of discarded SAMS (only CPE)ro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.9 |
plInpNodeTableInput Characteristics Remote equipments connected SEQUENCE OF PlInpNodeEntry .1.3.6.1.4.1.13995.1.1.3.4 |
plInpNodeEntryRow of table plInpNodeTable PlInpNodeEntry .1.3.6.1.4.1.13995.1.1.3.4.1 |
plInpNodeReceivedPktsNumber of Packets received from cpeId userro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.1 |
plInpNodeReceivedUnrecPktsNumber of Unrecoverable received packetsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.2 |
plInpNodeReceivedCorrectedPktsNumber of Corrected (by FEC) received packetsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.3 |
plInpNodeReceivedOctetsNumber of Received bytesro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.4 |
plInpNodeReceivedCorrectedOctetsNumber of Corrected (by FEC) received bytesro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.5 |
plInpNodeReceivedPowerTotal received powerro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.6 |
plInpNodePLRPacket Loss Ratero Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.7 |
plInpNodeMeanBPCMean BPC: sum of current bits configurationro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.8 |
plInpNodeSNRChangesChanges of SNRro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.9 |
plInpNodeSNRString with SNR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.ro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.10 |
plInpNodeBPCString with BPC per carrier configuration: contains 256 bytes if it is a HE or 384 if it is a CPE.ro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.11 |
plInpNodeCFRString with CFR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.ro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.12 |
plInpNodeEnableCarriersString with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.rw DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.13 |
plInpNodeProtocolEnableCarriersString with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.ro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.14 |
plInpNodeEnableProtocolEnableCarriersEnable protocol (1) and disable protocol (0).rw Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.15 |
plTraps OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.4 |
plRemoteCPE OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.5 |
internal OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.2 |
amperionSystem OBJECT IDENTIFIER .1.3.6.1.4.1.13995.2 |
serialNumberThe serial number of the board, which is unique per part numberro DisplayString .1.3.6.1.4.1.13995.2.1 |
partNumberThe part number of the board, which identifies the board typero DisplayString .1.3.6.1.4.1.13995.2.2 |
rombootVersionThe string that identifies the Romboot softwarero DisplayString .1.3.6.1.4.1.13995.2.3 |
alarmsDynamic alarm table - shows all the outstanding alarms on
the system SEQUENCE OF AlarmsEntry .1.3.6.1.4.1.13995.2.4 |
alarmsEntryRow of table alarms AlarmsEntry .1.3.6.1.4.1.13995.2.4.1 |
alarmIndexThe alarmIndex uniquely identifies alarms on the system Integer32 .1.3.6.1.4.1.13995.2.4.1.1 |
descriptionTextual description of the alarmro DisplayString .1.3.6.1.4.1.13995.2.4.1.2 |
productTypeinjector/extractor/repeatorro Enumeration .1.3.6.1.4.1.13995.2.5 |
userGpsInfoStringUser defined string for the user to put the GPS info of this devicerw DisplayString .1.3.6.1.4.1.13995.2.6 |
linuxVersionThe string that identifies the Linux kernel softwarero DisplayString .1.3.6.1.4.1.13995.2.8 |
amperionSysDescrA textual description of the entity. This value
should include the full name and version
identification of the system's hardware type,
software operating-system, and networking
software. It is mandatory that this only contain
printable ASCII characters.ro DisplayString .1.3.6.1.4.1.13995.2.10 |
amperionSysObjectIDThe vendor's authoritative identification of the
network management subsystem contained in the
entity. This value is allocated within the SMI
enterprises subtree (1.3.6.1.4.1) and provides an
easy and unambiguous means for determining `what
kind of box' is being managed. For example, if
vendor `Flintstones, Inc.' was assigned the
subtree 1.3.6.1.4.1.4242, it could assign the
identifier 1.3.6.1.4.1.4242.1.1 to its `Fred
Router'.ro OBJECT IDENTIFIER .1.3.6.1.4.1.13995.2.11 |
amperionSysUpTimeThe time (in hundredths of a second) since the
network management portion of the system was last
re-initialized.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.13995.2.12 |
amperionSysContactThe textual identification of the contact person
for this managed node, together with information
on how to contact this person.rw DisplayString .1.3.6.1.4.1.13995.2.13 |
amperionSysNameAn administratively-assigned name for this
managed node. By convention, this is the node's
fully-qualified domain name.rw DisplayString .1.3.6.1.4.1.13995.2.14 |
amperionSysLocationThe physical location of this node (e.g.,
`telephone closet, 3rd floor').rw DisplayString .1.3.6.1.4.1.13995.2.15 |
amperionSysServicesA value which indicates the set of services that
this entity primarily offers.
The value is a sum. This sum initially takes the
value zero, Then, for each layer, L, in the range
1 through 7, that this node performs transactions
for, 2 raised to (L - 1) is added to the sum. For
example, a node which performs primarily routing
functions would have a value of 4 (2^(3-1)). In
contrast, a node which is a host offering
application services would have a value of 72
(2^(4-1) + 2^(7-1)). Note that in the context of
the Internet suite of protocols, values should be
calculated accordingly:
layer functionality
1 physical (e.g., repeaters)
2 datalink/subnetwork (e.g., bridges)
3 internet (e.g., IP gateways)
4 end-to-end (e.g., IP hosts)
7 applications (e.g., mail relays)
For systems including OSI protocols, layers 5 and
6 may also be counted.ro Integer32 .1.3.6.1.4.1.13995.2.16 |
amperionTrapMgr1IP address of Manager receceiving trapsrw IpAddress .1.3.6.1.4.1.13995.2.18 |
amperionTrapMgr2IP address of Manager receceiving trapsrw IpAddress .1.3.6.1.4.1.13995.2.19 |
amperionTrapMgr3amperionTrapMgr3rw IpAddress .1.3.6.1.4.1.13995.2.20 |
softwareUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.13995.3 |
serverAddressName or IP Address of the primary file server from which to retrieve new software.rw DisplayString .1.3.6.1.4.1.13995.3.1 |
primaryPartitionContentsDescription of image in primary partition.ro DisplayString .1.3.6.1.4.1.13995.3.2 |
currentStateCurrent state of the software upgrade.ro Enumeration .1.3.6.1.4.1.13995.3.3 |
bootPartitionImage in this partition will be used when the system boots.rw Enumeration .1.3.6.1.4.1.13995.3.4 |
upgradePartitionDefault partition to erase and load with a new image.rw Enumeration .1.3.6.1.4.1.13995.3.5 |
currentPartitionPartition from which currently running software was loaded.ro Enumeration .1.3.6.1.4.1.13995.3.6 |
commandOptionsSoftware upgrade options: Reserved for future userw DisplayString .1.3.6.1.4.1.13995.3.7 |
backupPartitionContentsDescription of image in backup partition.ro DisplayString .1.3.6.1.4.1.13995.3.8 |
primaryCRCCRC status of image in primary partition.ro Enumeration .1.3.6.1.4.1.13995.3.9 |
backupCRCCRC status of image in backup partition.ro Enumeration .1.3.6.1.4.1.13995.3.10 |
lastStatusStatus of current or last software upgrade performed (since last reboot).ro DisplayString .1.3.6.1.4.1.13995.3.11 |
filenamePath to filename to retrieve for software upgraderw DisplayString .1.3.6.1.4.1.13995.3.12 |
server1AddressName or IP Address of the alternate file server from which to retrieve new software.rw DisplayString .1.3.6.1.4.1.13995.3.13 |
server2AddressName or IP Address of the second alternate file server from which to retrieve new software.rw DisplayString .1.3.6.1.4.1.13995.3.14 |
upgradeScheduleScheduled upgrade date and time in MMDDhhmm format.rw DisplayString .1.3.6.1.4.1.13995.3.15 |
rebootScheduleScheduled reboot date and time in MMDDhhmm format.rw DisplayString .1.3.6.1.4.1.13995.3.16 |
loginlogin to use for software upgrade file server access.rw DisplayString .1.3.6.1.4.1.13995.3.17 |
passwordpassword to use for software upgrade file server access.rw DisplayString .1.3.6.1.4.1.13995.3.18 |
swupgradeCompletedswupgradeCompleted NOTIFICATION-TYPE .1.3.6.1.4.1.13995.3.19 |
psGroup OBJECT IDENTIFIER .1.3.6.1.4.1.13995.4 |
acLineVoltageState of AC Line voltage (on/off)ro Enumeration .1.3.6.1.4.1.13995.4.1 |
plus12vRegulated 12 volt supplyro DisplayString .1.3.6.1.4.1.13995.4.2 |
minus8point5vRegulated -8.5 volt supplyro DisplayString .1.3.6.1.4.1.13995.4.3 |
plus5vRegulated +5 volt supplyro DisplayString .1.3.6.1.4.1.13995.4.4 |
plus3point3vRegulated +3.3 volt supplyro DisplayString .1.3.6.1.4.1.13995.4.5 |
batteryCaseTempBattery Case Temperaturero DisplayString .1.3.6.1.4.1.13995.4.6 |
internalMcuTempInternal Micro Controller Unit Temperaturero DisplayString .1.3.6.1.4.1.13995.4.7 |
batteryCurrentBattery Currentro DisplayString .1.3.6.1.4.1.13995.4.8 |
batteryVoltageBattery Voltagero DisplayString .1.3.6.1.4.1.13995.4.9 |
mcuSoftwareVersionMicro Controller Unit Software Versionro DisplayString .1.3.6.1.4.1.13995.4.10 |
powerCycleNpuPower Cycle the Network Processor Unitrw Enumeration .1.3.6.1.4.1.13995.4.11 |
psModePower Supply mode, normal mode is protocol;
dump mode is a debug mode which displays debug prints from the MCUro Enumeration .1.3.6.1.4.1.13995.4.12 |
shutdownNpuShut down 12v, -8.5v, 3.3v and 5v regulators driving the
Network Processor Unit. This should only be used if one of the voltages
is too high.rw Enumeration .1.3.6.1.4.1.13995.4.13 |
psImageChecksumErrorThe power supply is notifying the main digital board that its main image
crc is incorrect. The main digital board needs to reprogram the new
power supply image again, or revert back to an older good image NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.14 |
criticalBatteryShutdownWarningThe power supply is warning the main digital board that we have
lost AC Line voltage and the battery is running low. The system will be
shutting down in seconds. Perform necessary backup. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.15 |
p12vOutOfRangeThe power supply is warning the main digital board that the +12v
regulator is out of range. If the condition is such that it is too high,
the decision may be to shutdown the regulator to avoid destroying the hardware NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.16 |
m8point5vOutOfRangeThe power supply is warning the main digital board that the -8.5v
regulator is out of range. Note that the -8.5v regulator is the same
regulator as the +12v. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.17 |
p5vOutOfRangeThe power supply is warning the main digital board that the +5v
regulator is out of range. If the condition is such that it is too high,
the decision may be to shutdown the regulator to avoid destroying
the hardware. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.18 |
p3point3vOutOfRangeThe power supply is warning the main digital board that the +3.3v
regulator is out of range. If the condition is such that it is too high,
the decision may be to shutdown the regulator to avoid destroying
the hardware. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.19 |
batteryVoltsOutOfRangeThe power supply is warning the main digital board that the
battery voltage is out of range. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.20 |
mcuTempOutOfRangeThe power supply is warning the main digital board that the
microcontroller unit core temperature is out of range. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.21 |
batteryTempOutOfRangeThe power supply is warning the main digital board that the battery
temperature is out of range NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.22 |
psDetectedCommLapsePower Supply notifies main digital board that it did not communnicate to the power supply within the agreed upon periodic interval NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.23 |
criticalRequestAbortedThe power supply is notifying the main digital board that one of the
critical requests was aborted due to not receiving it twice in a row. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.24 |
powerSupplyInternalErrorPower Supply / netmgt (PS thread) detected an internal error condition NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.25 |
psBatteryNotConnectedPower Supply Battery Not Connected. There is no battery backup for the system. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.26 |
psAcOnOffPower Supply detected AC going ON / OFF NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.27 |
psHardwareVersionHardware Version of the Power SUpplyro DisplayString .1.3.6.1.4.1.13995.4.28 |
psHardwareErrorThe power supply is notifying the main digital board that it incurred a hardware error NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.29 |
psEtPower Supply elapsed time since powerupro DisplayString .1.3.6.1.4.1.13995.4.30 |
npuEtPower Supply elapsed time since powerupro DisplayString .1.3.6.1.4.1.13995.4.31 |
npuPuTimesNumber of times the Network Processing Unit has been powered up.ro Integer32 .1.3.6.1.4.1.13995.4.32 |
eventDescriptionDescription of the Last Event - Used in sending trapsro DisplayString .1.3.6.1.4.1.13995.4.33 |
npuDetectedCommLapseNetwork processing unit could not communnicate to the power supply NOTIFICATION-TYPE .1.3.6.1.4.1.13995.4.34 |
amperionInterfaces OBJECT IDENTIFIER .1.3.6.1.4.1.13995.5 |
amperionifNumberThe number of network interfaces (regardless of
their current state) present on this system.ro Integer32 .1.3.6.1.4.1.13995.5.1 |
amperionifTableA list of interface entries. The number of
entries is given by the value of ifNumber. SEQUENCE OF AmperionifEntry .1.3.6.1.4.1.13995.5.2 |
amperionifEntryRow of table amperionifTable AmperionifEntry .1.3.6.1.4.1.13995.5.2.1 |
amperionWirelessActivateCommand to activate 802.11 parameters on demand.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13995.5.2.1.1 |
amperionifDescrA textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface.ro DisplayString .1.3.6.1.4.1.13995.5.2.1.2 |
amperionifTypeThe type of interface, distinguished according to
the physical/link protocol(s) immediately `below'
the network layer in the protocol stack.ro Enumeration .1.3.6.1.4.1.13995.5.2.1.3 |
amperionifMtuThe size of the largest datagram which can be
sent/received on the interface, specified in
octets. For interfaces that are used for
transmitting network datagrams, this is the size
of the largest network datagram that can be sent
on the interface.ro Integer32 .1.3.6.1.4.1.13995.5.2.1.4 |
amperionifSpeedAn estimate of the interface's current bandwidth
in bits per second. For interfaces which do not
vary in bandwidth or for those where no accurate
estimation can be made, this object should contain
the nominal bandwidth.ro Gauge32 .1.3.6.1.4.1.13995.5.2.1.5 |
amperionifPhysAddressThe interface's address at the protocol layer
immediately `below' the network layer in the
protocol stack. For interfaces which do not have
such an address (e.g., a serial line), this object
should contain an octet string of zero length.ro DisplayString .1.3.6.1.4.1.13995.5.2.1.6 |
amperionifAdminStatusThe desired state of the interface. The
testing(3) state indicates that no operational
packets can be passed.rw Enumeration .1.3.6.1.4.1.13995.5.2.1.7 |
amperionifOperStatusThe current operational state of the interface.
The testing(3) state indicates that no operational
packets can be passed.ro Enumeration .1.3.6.1.4.1.13995.5.2.1.8 |
amperionifLastChangeThe value of sysUpTime at the time the interface
entered its current operational state. If the
current state was entered prior to the last re-
initialization of the local network management
subsystem, then this object contains a zero
value.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.13995.5.2.1.9 |
amperionifInOctetsThe total number of octets received on the
interface, including framing characters.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.10 |
amperionifInUcastPktsThe number of subnetwork-unicast packets
delivered to a higher-layer protocol.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.11 |
amperionifInNUcastPktsThe number of non-unicast (i.e., subnetwork-
broadcast or subnetwork-multicast) packets
delivered to a higher-layer protocol.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.12 |
amperionifInDiscardsThe number of inbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being deliverable to a
higher-layer protocol. One possible reason for
discarding such a packet could be to free up
buffer space.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.13 |
amperionifInErrorsThe number of inbound packets that contained
errors preventing them from being deliverable to a
higher-layer protocol.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.14 |
amperionifInUnknownProtosThe number of packets received via the interface
which were discarded because of an unknown or
unsupported protocol.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.15 |
amperionifOutOctetsThe total number of octets transmitted out of the
interface, including framing characters.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.16 |
amperionifOutUcastPktsThe total number of packets that higher-level
protocols requested be transmitted to a
subnetwork-unicast address, including those that
were discarded or not sent.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.17 |
amperionifOutNUcastPktsThe total number of packets that higher-level
protocols requested be transmitted to a non-
unicast (i.e., a subnetwork-broadcast or
subnetwork-multicast) address, including those
that were discarded or not sent.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.18 |
amperionifOutDiscardsThe number of outbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being transmitted. One
possible reason for discarding such a packet could
be to free up buffer space.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.19 |
amperionifOutErrorsThe number of outbound packets that could not be
transmitted because of errors.ro Counter32 .1.3.6.1.4.1.13995.5.2.1.20 |
amperionifOutQLenThe length of the output packet queue (in
packets).ro Gauge32 .1.3.6.1.4.1.13995.5.2.1.21 |
amperionifSpecificA reference to MIB definitions specific to the
particular media being used to realize the
interface. For example, if the interface is
realized by an ethernet, then the value of this
object refers to a document defining objects
specific to ethernet. If this information is not
present, its value should be set to the OBJECT
IDENTIFIER { 0 0 }, which is a syntatically valid
object identifier, and any conformant
implementation of ASN.1 and BER must be able to
generate and recognize this value.ro OBJECT IDENTIFIER .1.3.6.1.4.1.13995.5.2.1.22 |
amperionWirelessConfigEssid802.11 network namerw DisplayString .1.3.6.1.4.1.13995.5.2.1.23 |
amperionWirelessConfigMode802.11 station operational moderw Enumeration .1.3.6.1.4.1.13995.5.2.1.24 |
amperionWirelessConfigChanFreq802.11 Channel IDrw Unsigned32 .1.3.6.1.4.1.13995.5.2.1.25 |
amperionWirelessConfigKey802.11 encryption or scrambling keys and encryption mode.rw DisplayString .1.3.6.1.4.1.13995.5.2.1.26 |
amperionWirelessLinkQualityA measure of how good the received signal is.ro Unsigned32 .1.3.6.1.4.1.13995.5.2.1.27 |
amperionWirelessSignalLevelReceived signal strength (how strong the received signal is).ro Unsigned32 .1.3.6.1.4.1.13995.5.2.1.28 |
amperionWirelessNoiseLevelBackground noise level (when no packet is transmited).ro Unsigned32 .1.3.6.1.4.1.13995.5.2.1.29 |
amperionWirelessConfigWifType802.11 protocol type.rw Enumeration .1.3.6.1.4.1.13995.5.2.1.30 |
amperionWirelessConfigBitRateThe bit transmission rate in Megabits per second. (0 = autonegotiated)rw Integer32 .1.3.6.1.4.1.13995.5.2.1.31 |
amperionWirelessConfigWDSPeerThe MAC address of any WDS peer.rw DisplayString .1.3.6.1.4.1.13995.5.2.1.32 |
interfaceAdminDownAdmin of Interface being set down NOTIFICATION-TYPE .1.3.6.1.4.1.13995.5.3 |
interfaceAdminUpInterface is being set up NOTIFICATION-TYPE .1.3.6.1.4.1.13995.5.4 |
amperionWireless OBJECT IDENTIFIER .1.3.6.1.4.1.13995.6 |
accessControlStatusStatus of the access control tablerw Enumeration .1.3.6.1.4.1.13995.6.1 |
ampMacAcceptTableList of Mac address to be accepted SEQUENCE OF AmpMacAcceptEntry .1.3.6.1.4.1.13995.6.3 |
ampMacAcceptEntryRow of table ampMacAcceptTable AmpMacAcceptEntry .1.3.6.1.4.1.13995.6.3.1 |
macAcceptTableMacAddressMac address to be acceptedrw DisplayString .1.3.6.1.4.1.13995.6.3.1.1 |
macAcceptTableRowStatusRow Statusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13995.6.3.1.2 |
macAcceptTableIndexUnique index Unsigned32 .1.3.6.1.4.1.13995.6.3.1.3 |
macAcceptTableWirelessIfThe wireless interface (e.g. wlan0) that ACL table is applied to.rw Unsigned32 .1.3.6.1.4.1.13995.6.3.1.4 |
amperionipAddrTableThe table of addressing information relevant to
this entity's IP addresses. SEQUENCE OF AmperionipAddrEntry .1.3.6.1.4.1.13995.7 |
amperionipAddrEntryRow of table amperionipAddrTable AmperionipAddrEntry .1.3.6.1.4.1.13995.7.1 |
amperionipAdEntAddrThe IP address to which this entry's addressing
information pertains. IpAddress .1.3.6.1.4.1.13995.7.1.1 |
amperionipAdEntIfNameThe name which uniquely identifies the
interface to which this entry is applicable.ro DisplayString .1.3.6.1.4.1.13995.7.1.2 |
amperionipAdEntNetMaskThe subnet mask associated with the IP address of
this entry. The value of the mask is an IP
address with all the network bits set to 1 and all
the hosts bits set to 0.ro IpAddress .1.3.6.1.4.1.13995.7.1.3 |
amperionipAdEntBcastAddrThe value of the least-significant bit in the IP
broadcast address used for sending datagrams on
the (logical) interface associated with the IP
address of this entry. For example, when the
Internet standard all-ones broadcast address is
used, the value will be 1. This value applies to
both the subnet and network broadcasts addresses
used by the entity on this (logical) interface.ro Integer32 .1.3.6.1.4.1.13995.7.1.4 |
amperionipAdEntReasmMaxSizeThe size of the largest IP datagram which this
entity can re-assemble from incoming IP fragmented
datagrams received on this interface.ro Integer32 .1.3.6.1.4.1.13995.7.1.5 |
amperionipAdRowStatusRow statusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13995.7.1.6 |
amperionipAdEntActivateCommand to activate the new IP address/netmask on demand.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13995.7.1.7 |
qualityOfService OBJECT IDENTIFIER .1.3.6.1.4.1.13995.8 |
serviceClassAService Class A (Bandwidth in Kbps)rw Unsigned32 .1.3.6.1.4.1.13995.8.1 |
serviceClassBService Class B (Bandwidth in Kbps)rw Unsigned32 .1.3.6.1.4.1.13995.8.2 |
serviceClassCService Class C (Bandwidth in Kbps)rw Unsigned32 .1.3.6.1.4.1.13995.8.3 |
serviceClassDService Class D (Bandwidth in Kbps)rw Unsigned32 .1.3.6.1.4.1.13995.8.4 |
subscriberTableList of subscribers SEQUENCE OF SubscriberEntry .1.3.6.1.4.1.13995.8.5 |
subscriberEntryRow of table subscriberTable SubscriberEntry .1.3.6.1.4.1.13995.8.5.1 |
indexSubscriber unique identification Unsigned32 .1.3.6.1.4.1.13995.8.5.1.1 |
nameSubscriber Namerw DisplayString .1.3.6.1.4.1.13995.8.5.1.2 |
ipAddressSubscriber IP addressrw IpAddress .1.3.6.1.4.1.13995.8.5.1.3 |
macAddressSubscriber MAC addressrw DisplayString .1.3.6.1.4.1.13995.8.5.1.4 |
serviceClassSubscriber Server Classrw Enumeration .1.3.6.1.4.1.13995.8.5.1.5 |
rowStatusA special field used to create new rows.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13995.8.5.1.6 |
upstreamDownstreamRatioUpstream bandwidth to downstream bandwidth ratiorw DisplayString .1.3.6.1.4.1.13995.8.6 |
qosStatusEnable or disable status of Qosrw Enumeration .1.3.6.1.4.1.13995.8.7 |
afe OBJECT IDENTIFIER .1.3.6.1.4.1.13995.9 |
afeExtractor OBJECT IDENTIFIER .1.3.6.1.4.1.13995.9.1 |
afeExtTxGainafeExtTxGainrw Integer32 .1.3.6.1.4.1.13995.9.1.1 |
afeExtRxGainafeExtRxGainrw Integer32 .1.3.6.1.4.1.13995.9.1.2 |
afeExtDownstreamafeExtDownstreamrw DisplayString .1.3.6.1.4.1.13995.9.1.3 |
afeExtUpstreamafeExtUpstreamrw DisplayString .1.3.6.1.4.1.13995.9.1.4 |
afeExtActivateafeExtActivaterw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13995.9.1.5 |
afeInjector OBJECT IDENTIFIER .1.3.6.1.4.1.13995.9.2 |
afeInjTxGainafeInjTxGainrw Integer32 .1.3.6.1.4.1.13995.9.2.1 |
afeInjRxGainafeInjRxGainrw Integer32 .1.3.6.1.4.1.13995.9.2.2 |
afeInjDownstreamafeInjDownstreamrw DisplayString .1.3.6.1.4.1.13995.9.2.3 |
afeInjUpstreamafeInjUpstreamrw DisplayString .1.3.6.1.4.1.13995.9.2.4 |
afeInjActivateafeInjActivaterw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13995.9.2.5 |
amperionRoutes OBJECT IDENTIFIER .1.3.6.1.4.1.13995.10 |
amperionRouteTableThis entity's IP Routing table. SEQUENCE OF AmperionRouteEntry .1.3.6.1.4.1.13995.10.1 |
amperionRouteEntryRow of table amperionRouteTable AmperionRouteEntry .1.3.6.1.4.1.13995.10.1.1 |
ipRouteDestThe destination IP address of this route. An
entry with a value of 0.0.0.0 is considered a
default route. Multiple routes to a single
destination can appear in the table, but access to
such multiple entries is dependent on the table-
access mechanisms defined by the network
management protocol in use.ro IpAddress .1.3.6.1.4.1.13995.10.1.1.1 |
ipRouteIfIndexThe index value which uniquely identifies the
local interface through which the next hop of this
route should be reached. The interface identified
by a particular value of this index is the same
interface as identified by the same value of
ifIndex.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.2 |
ipRouteMetric1The primary routing metric for this route. The
semantics of this metric are determined by the
routing-protocol specified in the route's
ipRouteProto value. If this metric is not used,
its value should be set to -1.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.3 |
ipRouteMetric2An alternate routing metric for this route. The
semantics of this metric are determined by the
routing-protocol specified in the route's
ipRouteProto value. If this metric is not used,
its value should be set to -1.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.4 |
ipRouteMetric3An alternate routing metric for this route. The
semantics of this metric are determined by the
routing-protocol specified in the route's
ipRouteProto value. If this metric is not used,
its value should be set to -1.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.5 |
ipRouteMetric4An alternate routing metric for this route. The
semantics of this metric are determined by the
routing-protocol specified in the route's
ipRouteProto value. If this metric is not used,
its value should be set to -1.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.6 |
ipRouteNextHopThe IP address of the next hop of this route.
(In the case of a route bound to an interface
which is realized via a broadcast media, the value
of this field is the agent's IP address on that
interface.)rw IpAddress .1.3.6.1.4.1.13995.10.1.1.7 |
ipRouteTypeThe type of route. Note that the values
direct(3) and indirect(4) refer to the notion of
direct and indirect routing in the IP
architecture.
Setting this object to the value invalid(2) has
the effect of invalidating the corresponding entry
in the ipRouteTable object. That is, it
effectively dissasociates the destination
identified with said entry from the route
identified with said entry. It is an
implementation-specific matter as to whether the
agent removes an invalidated entry from the table.
Accordingly, management stations must be prepared
to receive tabular information from agents that
corresponds to entries not currently in use.
Proper interpretation of such entries requires
examination of the relevant ipRouteType object.ro Enumeration .1.3.6.1.4.1.13995.10.1.1.8 |
ipRouteProtoThe routing mechanism via which this route was
learned. Inclusion of values for gateway routing
protocols is not intended to imply that hosts
should support those protocols.ro Enumeration .1.3.6.1.4.1.13995.10.1.1.9 |
ipRouteAgeThe number of seconds since this route was last
updated or otherwise determined to be correct.
Note that no semantics of `too old' can be implied
except through knowledge of the routing protocol
by which the route was learned.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.10 |
ipRouteMaskIndicate the mask to be logical-ANDed with the
destination address before being compared to the
value in the ipRouteDest field. For those systems
that do not support arbitrary subnet masks, an
agent constructs the value of the ipRouteMask by
determining whether the value of the correspondent
ipRouteDest field belong to a class-A, B, or C
network, and then using one of:
mask network
255.0.0.0 class-A
255.255.0.0 class-B
255.255.255.0 class-C
If the value of the ipRouteDest is 0.0.0.0 (a
default route), then the mask value is also
0.0.0.0. It should be noted that all IP routing
subsystems implicitly use this mechanism.rw IpAddress .1.3.6.1.4.1.13995.10.1.1.11 |
ipRouteMetric5An alternate routing metric for this route. The
semantics of this metric are determined by the
routing-protocol specified in the route's
ipRouteProto value. If this metric is not used,
its value should be set to -1.rw Integer32 .1.3.6.1.4.1.13995.10.1.1.12 |
ipRouteInfoA reference to MIB definitions specific to the
particular routing protocol which is responsible
for this route, as determined by the value
specified in the route's ipRouteProto value. If
this information is not present, its value should
be set to the OBJECT IDENTIFIER { 0 0 }, which is
a syntatically valid object identifier, and any
conformant implementation of ASN.1 and BER must be
able to generate and recognize this value.ro OBJECT IDENTIFIER .1.3.6.1.4.1.13995.10.1.1.13 |
ipDefRouteActivateCommand to activate the new default route.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13995.10.1.1.14 |
plc OBJECT IDENTIFIER .1.3.6.1.4.1.13995.11 |
plcExtractor OBJECT IDENTIFIER .1.3.6.1.4.1.13995.11.1 |
plcExtTxGainplcExtTxGainrw Integer32 .1.3.6.1.4.1.13995.11.1.1 |
plcExtRxGainplcExtRxGainrw Integer32 .1.3.6.1.4.1.13995.11.1.2 |
plcInjector OBJECT IDENTIFIER .1.3.6.1.4.1.13995.11.2 |
plcInjTxGainplcInjTxGainrw Integer32 .1.3.6.1.4.1.13995.11.2.1 |
plcInjRxGainplcInjRxGainrw Integer32 .1.3.6.1.4.1.13995.11.2.2 |
plcUpExtractor's PLC interface came up NOTIFICATION-TYPE .1.3.6.1.4.1.13995.11.3 |
plcDownExtractor's PLC interface went down NOTIFICATION-TYPE .1.3.6.1.4.1.13995.11.4 |
afeCpldResetCountafe Cpld Reset Countro Counter32 .1.3.6.1.4.1.13995.11.5 |
plcLossCountplc Loss Countro Counter32 .1.3.6.1.4.1.13995.11.6 |
resetCountersreset Countersrw Enumeration .1.3.6.1.4.1.13995.11.7 |
optimizationTableIf Injector -
This table contains the frequencies(channels) / gains /
throughput of all the extractors down stream.
If Extractor -
This table should contain frequencies(channels) / gains /
throughput for the the plc segment between this extractor
and the injector/repeator upstream. SEQUENCE OF OptimizationEntry .1.3.6.1.4.1.13995.11.8 |
optimizationEntryRow of table optimizationTable OptimizationEntry .1.3.6.1.4.1.13995.11.8.1 |
extrIpaddressextractor's ipaddressro IpAddress .1.3.6.1.4.1.13995.11.8.1.1 |
extrChannelNumberExtractor Channel Numberro Integer32 .1.3.6.1.4.1.13995.11.8.1.2 |
upstreamFreqUpstream Frequencyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13995.11.8.1.3 |
downstreamFreqDownstream Frequencyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13995.11.8.1.4 |
rxGainrxGain settingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13995.11.8.1.5 |
txGainTx Gain Settingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13995.11.8.1.6 |
plcThroughputplcThroughputro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13995.11.8.1.7 |
upStreamDownStreamThis to indicate if this entry pertains to the upstream segment
or the downstream segmentro Enumeration .1.3.6.1.4.1.13995.11.8.1.8 |
gpsInfoGPS co-ordinates. Currently this is a string which means the machine
just picks up whatever GPS info is defined in it's system group and sends it
to the extractorro DisplayString .1.3.6.1.4.1.13995.11.8.1.9 |
plcEventDescriptionString to be sent in the plc up/down event. Will contain ip address of the
unit which just went down or will say 'local system' if current systemro DisplayString .1.3.6.1.4.1.13995.11.9 |
tempGroup OBJECT IDENTIFIER .1.3.6.1.4.1.13995.12 |
tempFanStateThe fans may be on or off.ro Enumeration .1.3.6.1.4.1.13995.12.1 |
tempFanTargetTempThe target temperature is the average temperature we would like the
system to operate at if possible. It is used to calculate how long the fans
should stay on during a cycle which is part of a duty cycle algorithm.
Temperature is in degrees celsius.rw Integer32 .1.3.6.1.4.1.13995.12.2 |
tempHighWarnLimitThe system temperature has exceeded a high temperature warning threshold.
Temperature is in degrees Celsius.rw Integer32 .1.3.6.1.4.1.13995.12.3 |
tempHighWarnLimitTrapThe system temperature has exceeded the High Warning threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.12.4 |
tempEventDescriptionString to be sent with the temperature trap events.ro DisplayString .1.3.6.1.4.1.13995.12.5 |
tempHighErrorLimitTrapThe system temperature has exceeded the High Error Threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.12.6 |
tempLowWarnLimitTrapThe system temperature has gone below the Low Warning Threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.12.7 |
tempLowErrorLimitTrapThe system temperature has gone below the Low Error Threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.13995.12.8 |
tempHighErrorLimitThe system temperature has exceeded a high temperature error threshold.
Temperature is in degrees Celsius.rw Integer32 .1.3.6.1.4.1.13995.12.9 |
tempLowWarnLimitThe system temperature has gone below a low temperature warning threshold.
Temperature is in degrees Celscius.rw Integer32(-100..60) UNITS "degrees Celscius" .1.3.6.1.4.1.13995.12.10 |
tempLowErrorLimitThe system temperature has gone below the Low Temperature Error Threshold.
The temperature is in degrees Celscius.rw Integer32(-100..60) UNITS "degrees Celscius" .1.3.6.1.4.1.13995.12.11 |
tempHighWarnHistHysteresis value for the High Temperature Warning Condition. Once the
system temperature has reached or exceeded the High Temperature
Warning threshold, it must go down to or below the Hysteresis temperature
before sending the trap again.
The hysteresis temperature is in degrees Celcius.rw Integer32(-10..150) UNITS "degrees Celsius" .1.3.6.1.4.1.13995.12.12 |
tempHighErrorHistHysteresis value for the High Temperature Error Condition. Once the
system temperature has reached or exceeded the High Temperature
Error Threshold, it must go down to or below the Hysteresis temperature
before sending the trap again.
The hysteresis temperature is in degrees Celcius.rw Integer32(-10..150) UNITS "degrees Celscius" .1.3.6.1.4.1.13995.12.13 |
tempLowWarnHistHysteresis value for the Low Temperature Warning Condition. Once the
system temperature is less than or equal to the LowTemperature Warning
threshold, it must go up to or above the Hysteresis temperature
before sending the trap again.
The hysteresis temperature is in degrees Celcius.rw Integer32(-100..60) UNITS "degrees Celscius" .1.3.6.1.4.1.13995.12.14 |
tempLowErrorHistHysteresis value for the Low Temperature Error Condition. Once the
system temperature is less than or equal to the LowTemperature Error
threshold, it must go up to or above the Hysteresis temperature
before sending the trap again.
The hysteresis temperature is in degrees Celcius.rw Integer32(-100..60) UNITS "degrees Celsius" .1.3.6.1.4.1.13995.12.15 |
tempSystemTempThe temperature of the Main Digital Board. The temperature is obtained
by reading a chip located on the digital board.ro Integer32 .1.3.6.1.4.1.13995.12.16 |