Home/Catalog/Amperion-MIB

Amperion-MIB

AI MIB Summary

The Amperion-MIB provides vendor-specific SNMP access for Amperion Inc. network infrastructure, enabling the monitoring of proprietary device metrics such as power consumption, thermal status, and interface statistics. This private MIB extension facilitates granular management of Amperion hardware components that are not covered by standard IETF MIBs.

Amperion Inc. private MIB
Main OID:
amperion.1.3.6.1.4.1.13995
277
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

277 total
Object Name
amperionAmperion Inc. private MIB
MODULE-IDENTITY
.1.3.6.1.4.1.13995
ds2
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1
powerline
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1
plMibIIExtension
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1.1
plCards
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1.1.2
plCdNumberNumber of Cards available. Maximum index of plCdTablero
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.1
plCdTablePowerline Cards Table. List of attributes of each Card available in the System. Indexed by the number of the Card (from 1 to plCdNumber).
SEQUENCE OF PlCdEntry
.1.3.6.1.4.1.13995.1.1.1.2.2
plCdEntryRow of table plCdTable
PlCdEntry
.1.3.6.1.4.1.13995.1.1.1.2.2.1
plCdIndexNumber of powerline card. Maximum: plCdNumber
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.1
plCdTypeType of card: 0 => HE 1 => CPEro
Enumeration
.1.3.6.1.4.1.13995.1.1.1.2.2.1.2
plCdShortMacAddressShort MAC Address of the Cardrw
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.4
plCdLongMacAddressLong MAC Address of the Cardro
DisplayString
.1.3.6.1.4.1.13995.1.1.1.2.2.1.5
plCdHardwareVersionHardware Versionro
DisplayString
.1.3.6.1.4.1.13995.1.1.1.2.2.1.6
plCdFirmwareVersionFirmware Versionro
DisplayString
.1.3.6.1.4.1.13995.1.1.1.2.2.1.7
plCdDriverVersionDriver Versionro
DisplayString
.1.3.6.1.4.1.13995.1.1.1.2.2.1.8
plCdResetReset to Saved Values. Soft Reset.rw
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.9
plCdFactoryResetReset to factory values. Hard Reset.rw
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.10
plCdSaveAsPermanentSave MIB values as default values: the information of the Remote List (long MAC address and short MAC address of each user) is saved and will be restored after a reboot or a poweroff.rw
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.11
plCdStatusStatus related to the interface: 0 => OK.ro
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.12
plCdRemoteListList of Long MAC Address that can be connected with HE (only HE). Returns a string with the list of long MAC address (not separated by spaces)ro
DisplayString
.1.3.6.1.4.1.13995.1.1.1.2.2.1.13
plCdNumRemoteListNumber of CPE in remote list (only HE). This is the maximum value for cpeId in Network table.ro
Integer32
.1.3.6.1.4.1.13995.1.1.1.2.2.1.14
plNetwork
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1.2
plNetTableNetwork Topology. Indexed by number of card and number of remote user (.plCdIndex.cpeId). Maximum values for indexes: plCdNumber and plCdNumRemoteList. Only available in HE.
SEQUENCE OF PlNetEntry
.1.3.6.1.4.1.13995.1.1.2.1
plNetEntryRow of table plNetTable
PlNetEntry
.1.3.6.1.4.1.13995.1.1.2.1.1
plNetShortMacAddressSMAC of remote CPE.
Integer32
.1.3.6.1.4.1.13995.1.1.2.1.1.1
plNetLongMacAddressLong Mac Address of Remote Node.rw
DisplayString
.1.3.6.1.4.1.13995.1.1.2.1.1.3
plNetRowStatusRow Statusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.13995.1.1.2.1.1.8
plTransmission
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1.3
plInpTableInput Channel Table. Common input characteristics. Indexed by number of card. Maximum value of index: plCdNumber
SEQUENCE OF PlInpEntry
.1.3.6.1.4.1.13995.1.1.3.2
plInpEntryRow of table plInpTable
PlInpEntry
.1.3.6.1.4.1.13995.1.1.3.2.1
plInpTotalOctetsTotal number of rx octets (including FEC overhead)ro
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.1
plInpGainReception gainrw
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.2
plInpAGCTo enable or disable Adaptive Rx Gain Control. 0 => AGC disabled 1 => AGC enabled.rw
Enumeration
.1.3.6.1.4.1.13995.1.1.3.2.1.3
plInpMaxGainMaximum reception gainrw
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.4
plInpThresholdsSNR Thresholds in dB. Returns a string containing 4 integers.rw
DisplayString
.1.3.6.1.4.1.13995.1.1.3.2.1.5
plInpAttenuationGainAttenuation Gain (only HE)rw
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.6
plInpSamsDecodeNumber of decoded SAMS (only CPE)ro
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.7
plInpSamsGoodNumber of used SAMS (only CPE)ro
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.8
plInpSamsBadNumber of discarded SAMS (only CPE)ro
Integer32
.1.3.6.1.4.1.13995.1.1.3.2.1.9
plInpNodeTableInput Characteristics Remote equipments connected
SEQUENCE OF PlInpNodeEntry
.1.3.6.1.4.1.13995.1.1.3.4
plInpNodeEntryRow of table plInpNodeTable
PlInpNodeEntry
.1.3.6.1.4.1.13995.1.1.3.4.1
plInpNodeReceivedPktsNumber of Packets received from cpeId userro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.1
plInpNodeReceivedUnrecPktsNumber of Unrecoverable received packetsro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.2
plInpNodeReceivedCorrectedPktsNumber of Corrected (by FEC) received packetsro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.3
plInpNodeReceivedOctetsNumber of Received bytesro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.4
plInpNodeReceivedCorrectedOctetsNumber of Corrected (by FEC) received bytesro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.5
plInpNodeReceivedPowerTotal received powerro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.6
plInpNodePLRPacket Loss Ratero
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.7
plInpNodeMeanBPCMean BPC: sum of current bits configurationro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.8
plInpNodeSNRChangesChanges of SNRro
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.9
plInpNodeSNRString with SNR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.ro
DisplayString
.1.3.6.1.4.1.13995.1.1.3.4.1.10
plInpNodeBPCString with BPC per carrier configuration: contains 256 bytes if it is a HE or 384 if it is a CPE.ro
DisplayString
.1.3.6.1.4.1.13995.1.1.3.4.1.11
plInpNodeCFRString with CFR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.ro
DisplayString
.1.3.6.1.4.1.13995.1.1.3.4.1.12
plInpNodeEnableCarriersString with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.rw
DisplayString
.1.3.6.1.4.1.13995.1.1.3.4.1.13
plInpNodeProtocolEnableCarriersString with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.ro
DisplayString
.1.3.6.1.4.1.13995.1.1.3.4.1.14
plInpNodeEnableProtocolEnableCarriersEnable protocol (1) and disable protocol (0).rw
Integer32
.1.3.6.1.4.1.13995.1.1.3.4.1.15
plTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1.4
plRemoteCPE
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.1.5
internal
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.1.2
amperionSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.2
serialNumberThe serial number of the board, which is unique per part numberro
DisplayString
.1.3.6.1.4.1.13995.2.1
partNumberThe part number of the board, which identifies the board typero
DisplayString
.1.3.6.1.4.1.13995.2.2
rombootVersionThe string that identifies the Romboot softwarero
DisplayString
.1.3.6.1.4.1.13995.2.3
alarmsDynamic alarm table - shows all the outstanding alarms on the system
SEQUENCE OF AlarmsEntry
.1.3.6.1.4.1.13995.2.4
alarmsEntryRow of table alarms
AlarmsEntry
.1.3.6.1.4.1.13995.2.4.1
alarmIndexThe alarmIndex uniquely identifies alarms on the system
Integer32
.1.3.6.1.4.1.13995.2.4.1.1
descriptionTextual description of the alarmro
DisplayString
.1.3.6.1.4.1.13995.2.4.1.2
productTypeinjector/extractor/repeatorro
Enumeration
.1.3.6.1.4.1.13995.2.5
userGpsInfoStringUser defined string for the user to put the GPS info of this devicerw
DisplayString
.1.3.6.1.4.1.13995.2.6
linuxVersionThe string that identifies the Linux kernel softwarero
DisplayString
.1.3.6.1.4.1.13995.2.8
amperionSysDescrA textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters.ro
DisplayString
.1.3.6.1.4.1.13995.2.10
amperionSysObjectIDThe vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.2.11
amperionSysUpTimeThe time (in hundredths of a second) since the network management portion of the system was last re-initialized.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.13995.2.12
amperionSysContactThe textual identification of the contact person for this managed node, together with information on how to contact this person.rw
DisplayString
.1.3.6.1.4.1.13995.2.13
amperionSysNameAn administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name.rw
DisplayString
.1.3.6.1.4.1.13995.2.14
amperionSysLocationThe physical location of this node (e.g., `telephone closet, 3rd floor').rw
DisplayString
.1.3.6.1.4.1.13995.2.15
amperionSysServicesA value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted.ro
Integer32
.1.3.6.1.4.1.13995.2.16
amperionTrapMgr1IP address of Manager receceiving trapsrw
IpAddress
.1.3.6.1.4.1.13995.2.18
amperionTrapMgr2IP address of Manager receceiving trapsrw
IpAddress
.1.3.6.1.4.1.13995.2.19
amperionTrapMgr3amperionTrapMgr3rw
IpAddress
.1.3.6.1.4.1.13995.2.20
softwareUpgrade
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.3
serverAddressName or IP Address of the primary file server from which to retrieve new software.rw
DisplayString
.1.3.6.1.4.1.13995.3.1
primaryPartitionContentsDescription of image in primary partition.ro
DisplayString
.1.3.6.1.4.1.13995.3.2
currentStateCurrent state of the software upgrade.ro
Enumeration
.1.3.6.1.4.1.13995.3.3
bootPartitionImage in this partition will be used when the system boots.rw
Enumeration
.1.3.6.1.4.1.13995.3.4
upgradePartitionDefault partition to erase and load with a new image.rw
Enumeration
.1.3.6.1.4.1.13995.3.5
currentPartitionPartition from which currently running software was loaded.ro
Enumeration
.1.3.6.1.4.1.13995.3.6
commandOptionsSoftware upgrade options: Reserved for future userw
DisplayString
.1.3.6.1.4.1.13995.3.7
backupPartitionContentsDescription of image in backup partition.ro
DisplayString
.1.3.6.1.4.1.13995.3.8
primaryCRCCRC status of image in primary partition.ro
Enumeration
.1.3.6.1.4.1.13995.3.9
backupCRCCRC status of image in backup partition.ro
Enumeration
.1.3.6.1.4.1.13995.3.10
lastStatusStatus of current or last software upgrade performed (since last reboot).ro
DisplayString
.1.3.6.1.4.1.13995.3.11
filenamePath to filename to retrieve for software upgraderw
DisplayString
.1.3.6.1.4.1.13995.3.12
server1AddressName or IP Address of the alternate file server from which to retrieve new software.rw
DisplayString
.1.3.6.1.4.1.13995.3.13
server2AddressName or IP Address of the second alternate file server from which to retrieve new software.rw
DisplayString
.1.3.6.1.4.1.13995.3.14
upgradeScheduleScheduled upgrade date and time in MMDDhhmm format.rw
DisplayString
.1.3.6.1.4.1.13995.3.15
rebootScheduleScheduled reboot date and time in MMDDhhmm format.rw
DisplayString
.1.3.6.1.4.1.13995.3.16
loginlogin to use for software upgrade file server access.rw
DisplayString
.1.3.6.1.4.1.13995.3.17
passwordpassword to use for software upgrade file server access.rw
DisplayString
.1.3.6.1.4.1.13995.3.18
swupgradeCompletedswupgradeCompleted
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.3.19
psGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.4
acLineVoltageState of AC Line voltage (on/off)ro
Enumeration
.1.3.6.1.4.1.13995.4.1
plus12vRegulated 12 volt supplyro
DisplayString
.1.3.6.1.4.1.13995.4.2
minus8point5vRegulated -8.5 volt supplyro
DisplayString
.1.3.6.1.4.1.13995.4.3
plus5vRegulated +5 volt supplyro
DisplayString
.1.3.6.1.4.1.13995.4.4
plus3point3vRegulated +3.3 volt supplyro
DisplayString
.1.3.6.1.4.1.13995.4.5
batteryCaseTempBattery Case Temperaturero
DisplayString
.1.3.6.1.4.1.13995.4.6
internalMcuTempInternal Micro Controller Unit Temperaturero
DisplayString
.1.3.6.1.4.1.13995.4.7
batteryCurrentBattery Currentro
DisplayString
.1.3.6.1.4.1.13995.4.8
batteryVoltageBattery Voltagero
DisplayString
.1.3.6.1.4.1.13995.4.9
mcuSoftwareVersionMicro Controller Unit Software Versionro
DisplayString
.1.3.6.1.4.1.13995.4.10
powerCycleNpuPower Cycle the Network Processor Unitrw
Enumeration
.1.3.6.1.4.1.13995.4.11
psModePower Supply mode, normal mode is protocol; dump mode is a debug mode which displays debug prints from the MCUro
Enumeration
.1.3.6.1.4.1.13995.4.12
shutdownNpuShut down 12v, -8.5v, 3.3v and 5v regulators driving the Network Processor Unit. This should only be used if one of the voltages is too high.rw
Enumeration
.1.3.6.1.4.1.13995.4.13
psImageChecksumErrorThe power supply is notifying the main digital board that its main image crc is incorrect. The main digital board needs to reprogram the new power supply image again, or revert back to an older good image
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.14
criticalBatteryShutdownWarningThe power supply is warning the main digital board that we have lost AC Line voltage and the battery is running low. The system will be shutting down in seconds. Perform necessary backup.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.15
p12vOutOfRangeThe power supply is warning the main digital board that the +12v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.16
m8point5vOutOfRangeThe power supply is warning the main digital board that the -8.5v regulator is out of range. Note that the -8.5v regulator is the same regulator as the +12v. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.17
p5vOutOfRangeThe power supply is warning the main digital board that the +5v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.18
p3point3vOutOfRangeThe power supply is warning the main digital board that the +3.3v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.19
batteryVoltsOutOfRangeThe power supply is warning the main digital board that the battery voltage is out of range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.20
mcuTempOutOfRangeThe power supply is warning the main digital board that the microcontroller unit core temperature is out of range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.21
batteryTempOutOfRangeThe power supply is warning the main digital board that the battery temperature is out of range
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.22
psDetectedCommLapsePower Supply notifies main digital board that it did not communnicate to the power supply within the agreed upon periodic interval
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.23
criticalRequestAbortedThe power supply is notifying the main digital board that one of the critical requests was aborted due to not receiving it twice in a row.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.24
powerSupplyInternalErrorPower Supply / netmgt (PS thread) detected an internal error condition
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.25
psBatteryNotConnectedPower Supply Battery Not Connected. There is no battery backup for the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.26
psAcOnOffPower Supply detected AC going ON / OFF
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.27
psHardwareVersionHardware Version of the Power SUpplyro
DisplayString
.1.3.6.1.4.1.13995.4.28
psHardwareErrorThe power supply is notifying the main digital board that it incurred a hardware error
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.29
psEtPower Supply elapsed time since powerupro
DisplayString
.1.3.6.1.4.1.13995.4.30
npuEtPower Supply elapsed time since powerupro
DisplayString
.1.3.6.1.4.1.13995.4.31
npuPuTimesNumber of times the Network Processing Unit has been powered up.ro
Integer32
.1.3.6.1.4.1.13995.4.32
eventDescriptionDescription of the Last Event - Used in sending trapsro
DisplayString
.1.3.6.1.4.1.13995.4.33
npuDetectedCommLapseNetwork processing unit could not communnicate to the power supply
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.4.34
amperionInterfaces
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.5
amperionifNumberThe number of network interfaces (regardless of their current state) present on this system.ro
Integer32
.1.3.6.1.4.1.13995.5.1
amperionifTableA list of interface entries. The number of entries is given by the value of ifNumber.
SEQUENCE OF AmperionifEntry
.1.3.6.1.4.1.13995.5.2
amperionifEntryRow of table amperionifTable
AmperionifEntry
.1.3.6.1.4.1.13995.5.2.1
amperionWirelessActivateCommand to activate 802.11 parameters on demand.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13995.5.2.1.1
amperionifDescrA textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the hardware interface.ro
DisplayString
.1.3.6.1.4.1.13995.5.2.1.2
amperionifTypeThe type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack.ro
Enumeration
.1.3.6.1.4.1.13995.5.2.1.3
amperionifMtuThe size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface.ro
Integer32
.1.3.6.1.4.1.13995.5.2.1.4
amperionifSpeedAn estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth.ro
Gauge32
.1.3.6.1.4.1.13995.5.2.1.5
amperionifPhysAddressThe interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length.ro
DisplayString
.1.3.6.1.4.1.13995.5.2.1.6
amperionifAdminStatusThe desired state of the interface. The testing(3) state indicates that no operational packets can be passed.rw
Enumeration
.1.3.6.1.4.1.13995.5.2.1.7
amperionifOperStatusThe current operational state of the interface. The testing(3) state indicates that no operational packets can be passed.ro
Enumeration
.1.3.6.1.4.1.13995.5.2.1.8
amperionifLastChangeThe value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re- initialization of the local network management subsystem, then this object contains a zero value.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.13995.5.2.1.9
amperionifInOctetsThe total number of octets received on the interface, including framing characters.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.10
amperionifInUcastPktsThe number of subnetwork-unicast packets delivered to a higher-layer protocol.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.11
amperionifInNUcastPktsThe number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.12
amperionifInDiscardsThe number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.13
amperionifInErrorsThe number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.14
amperionifInUnknownProtosThe number of packets received via the interface which were discarded because of an unknown or unsupported protocol.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.15
amperionifOutOctetsThe total number of octets transmitted out of the interface, including framing characters.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.16
amperionifOutUcastPktsThe total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.17
amperionifOutNUcastPktsThe total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.18
amperionifOutDiscardsThe number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.19
amperionifOutErrorsThe number of outbound packets that could not be transmitted because of errors.ro
Counter32
.1.3.6.1.4.1.13995.5.2.1.20
amperionifOutQLenThe length of the output packet queue (in packets).ro
Gauge32
.1.3.6.1.4.1.13995.5.2.1.21
amperionifSpecificA reference to MIB definitions specific to the particular media being used to realize the interface. For example, if the interface is realized by an ethernet, then the value of this object refers to a document defining objects specific to ethernet. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.5.2.1.22
amperionWirelessConfigEssid802.11 network namerw
DisplayString
.1.3.6.1.4.1.13995.5.2.1.23
amperionWirelessConfigMode802.11 station operational moderw
Enumeration
.1.3.6.1.4.1.13995.5.2.1.24
amperionWirelessConfigChanFreq802.11 Channel IDrw
Unsigned32
.1.3.6.1.4.1.13995.5.2.1.25
amperionWirelessConfigKey802.11 encryption or scrambling keys and encryption mode.rw
DisplayString
.1.3.6.1.4.1.13995.5.2.1.26
amperionWirelessLinkQualityA measure of how good the received signal is.ro
Unsigned32
.1.3.6.1.4.1.13995.5.2.1.27
amperionWirelessSignalLevelReceived signal strength (how strong the received signal is).ro
Unsigned32
.1.3.6.1.4.1.13995.5.2.1.28
amperionWirelessNoiseLevelBackground noise level (when no packet is transmited).ro
Unsigned32
.1.3.6.1.4.1.13995.5.2.1.29
amperionWirelessConfigWifType802.11 protocol type.rw
Enumeration
.1.3.6.1.4.1.13995.5.2.1.30
amperionWirelessConfigBitRateThe bit transmission rate in Megabits per second. (0 = autonegotiated)rw
Integer32
.1.3.6.1.4.1.13995.5.2.1.31
amperionWirelessConfigWDSPeerThe MAC address of any WDS peer.rw
DisplayString
.1.3.6.1.4.1.13995.5.2.1.32
interfaceAdminDownAdmin of Interface being set down
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.5.3
interfaceAdminUpInterface is being set up
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.5.4
amperionWireless
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.6
accessControlStatusStatus of the access control tablerw
Enumeration
.1.3.6.1.4.1.13995.6.1
ampMacAcceptTableList of Mac address to be accepted
SEQUENCE OF AmpMacAcceptEntry
.1.3.6.1.4.1.13995.6.3
ampMacAcceptEntryRow of table ampMacAcceptTable
AmpMacAcceptEntry
.1.3.6.1.4.1.13995.6.3.1
macAcceptTableMacAddressMac address to be acceptedrw
DisplayString
.1.3.6.1.4.1.13995.6.3.1.1
macAcceptTableRowStatusRow Statusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.13995.6.3.1.2
macAcceptTableIndexUnique index
Unsigned32
.1.3.6.1.4.1.13995.6.3.1.3
macAcceptTableWirelessIfThe wireless interface (e.g. wlan0) that ACL table is applied to.rw
Unsigned32
.1.3.6.1.4.1.13995.6.3.1.4
amperionipAddrTableThe table of addressing information relevant to this entity's IP addresses.
SEQUENCE OF AmperionipAddrEntry
.1.3.6.1.4.1.13995.7
amperionipAddrEntryRow of table amperionipAddrTable
AmperionipAddrEntry
.1.3.6.1.4.1.13995.7.1
amperionipAdEntAddrThe IP address to which this entry's addressing information pertains.
IpAddress
.1.3.6.1.4.1.13995.7.1.1
amperionipAdEntIfNameThe name which uniquely identifies the interface to which this entry is applicable.ro
DisplayString
.1.3.6.1.4.1.13995.7.1.2
amperionipAdEntNetMaskThe subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.ro
IpAddress
.1.3.6.1.4.1.13995.7.1.3
amperionipAdEntBcastAddrThe value of the least-significant bit in the IP broadcast address used for sending datagrams on the (logical) interface associated with the IP address of this entry. For example, when the Internet standard all-ones broadcast address is used, the value will be 1. This value applies to both the subnet and network broadcasts addresses used by the entity on this (logical) interface.ro
Integer32
.1.3.6.1.4.1.13995.7.1.4
amperionipAdEntReasmMaxSizeThe size of the largest IP datagram which this entity can re-assemble from incoming IP fragmented datagrams received on this interface.ro
Integer32
.1.3.6.1.4.1.13995.7.1.5
amperionipAdRowStatusRow statusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.13995.7.1.6
amperionipAdEntActivateCommand to activate the new IP address/netmask on demand.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13995.7.1.7
qualityOfService
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.8
serviceClassAService Class A (Bandwidth in Kbps)rw
Unsigned32
.1.3.6.1.4.1.13995.8.1
serviceClassBService Class B (Bandwidth in Kbps)rw
Unsigned32
.1.3.6.1.4.1.13995.8.2
serviceClassCService Class C (Bandwidth in Kbps)rw
Unsigned32
.1.3.6.1.4.1.13995.8.3
serviceClassDService Class D (Bandwidth in Kbps)rw
Unsigned32
.1.3.6.1.4.1.13995.8.4
subscriberTableList of subscribers
SEQUENCE OF SubscriberEntry
.1.3.6.1.4.1.13995.8.5
subscriberEntryRow of table subscriberTable
SubscriberEntry
.1.3.6.1.4.1.13995.8.5.1
indexSubscriber unique identification
Unsigned32
.1.3.6.1.4.1.13995.8.5.1.1
nameSubscriber Namerw
DisplayString
.1.3.6.1.4.1.13995.8.5.1.2
ipAddressSubscriber IP addressrw
IpAddress
.1.3.6.1.4.1.13995.8.5.1.3
macAddressSubscriber MAC addressrw
DisplayString
.1.3.6.1.4.1.13995.8.5.1.4
serviceClassSubscriber Server Classrw
Enumeration
.1.3.6.1.4.1.13995.8.5.1.5
rowStatusA special field used to create new rows.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.13995.8.5.1.6
upstreamDownstreamRatioUpstream bandwidth to downstream bandwidth ratiorw
DisplayString
.1.3.6.1.4.1.13995.8.6
qosStatusEnable or disable status of Qosrw
Enumeration
.1.3.6.1.4.1.13995.8.7
afe
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.9
afeExtractor
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.9.1
afeExtTxGainafeExtTxGainrw
Integer32
.1.3.6.1.4.1.13995.9.1.1
afeExtRxGainafeExtRxGainrw
Integer32
.1.3.6.1.4.1.13995.9.1.2
afeExtDownstreamafeExtDownstreamrw
DisplayString
.1.3.6.1.4.1.13995.9.1.3
afeExtUpstreamafeExtUpstreamrw
DisplayString
.1.3.6.1.4.1.13995.9.1.4
afeExtActivateafeExtActivaterw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13995.9.1.5
afeInjector
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.9.2
afeInjTxGainafeInjTxGainrw
Integer32
.1.3.6.1.4.1.13995.9.2.1
afeInjRxGainafeInjRxGainrw
Integer32
.1.3.6.1.4.1.13995.9.2.2
afeInjDownstreamafeInjDownstreamrw
DisplayString
.1.3.6.1.4.1.13995.9.2.3
afeInjUpstreamafeInjUpstreamrw
DisplayString
.1.3.6.1.4.1.13995.9.2.4
afeInjActivateafeInjActivaterw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13995.9.2.5
amperionRoutes
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.10
amperionRouteTableThis entity's IP Routing table.
SEQUENCE OF AmperionRouteEntry
.1.3.6.1.4.1.13995.10.1
amperionRouteEntryRow of table amperionRouteTable
AmperionRouteEntry
.1.3.6.1.4.1.13995.10.1.1
ipRouteDestThe destination IP address of this route. An entry with a value of 0.0.0.0 is considered a default route. Multiple routes to a single destination can appear in the table, but access to such multiple entries is dependent on the table- access mechanisms defined by the network management protocol in use.ro
IpAddress
.1.3.6.1.4.1.13995.10.1.1.1
ipRouteIfIndexThe index value which uniquely identifies the local interface through which the next hop of this route should be reached. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.2
ipRouteMetric1The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.3
ipRouteMetric2An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.4
ipRouteMetric3An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.5
ipRouteMetric4An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.6
ipRouteNextHopThe IP address of the next hop of this route. (In the case of a route bound to an interface which is realized via a broadcast media, the value of this field is the agent's IP address on that interface.)rw
IpAddress
.1.3.6.1.4.1.13995.10.1.1.7
ipRouteTypeThe type of route. Note that the values direct(3) and indirect(4) refer to the notion of direct and indirect routing in the IP architecture. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipRouteTable object. That is, it effectively dissasociates the destination identified with said entry from the route identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipRouteType object.ro
Enumeration
.1.3.6.1.4.1.13995.10.1.1.8
ipRouteProtoThe routing mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols.ro
Enumeration
.1.3.6.1.4.1.13995.10.1.1.9
ipRouteAgeThe number of seconds since this route was last updated or otherwise determined to be correct. Note that no semantics of `too old' can be implied except through knowledge of the routing protocol by which the route was learned.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.10
ipRouteMaskIndicate the mask to be logical-ANDed with the destination address before being compared to the value in the ipRouteDest field. For those systems that do not support arbitrary subnet masks, an agent constructs the value of the ipRouteMask by determining whether the value of the correspondent ipRouteDest field belong to a class-A, B, or C network, and then using one of: mask network 255.0.0.0 class-A 255.255.0.0 class-B 255.255.255.0 class-C If the value of the ipRouteDest is 0.0.0.0 (a default route), then the mask value is also 0.0.0.0. It should be noted that all IP routing subsystems implicitly use this mechanism.rw
IpAddress
.1.3.6.1.4.1.13995.10.1.1.11
ipRouteMetric5An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.rw
Integer32
.1.3.6.1.4.1.13995.10.1.1.12
ipRouteInfoA reference to MIB definitions specific to the particular routing protocol which is responsible for this route, as determined by the value specified in the route's ipRouteProto value. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.10.1.1.13
ipDefRouteActivateCommand to activate the new default route.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13995.10.1.1.14
plc
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.11
plcExtractor
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.11.1
plcExtTxGainplcExtTxGainrw
Integer32
.1.3.6.1.4.1.13995.11.1.1
plcExtRxGainplcExtRxGainrw
Integer32
.1.3.6.1.4.1.13995.11.1.2
plcInjector
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.11.2
plcInjTxGainplcInjTxGainrw
Integer32
.1.3.6.1.4.1.13995.11.2.1
plcInjRxGainplcInjRxGainrw
Integer32
.1.3.6.1.4.1.13995.11.2.2
plcUpExtractor's PLC interface came up
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.11.3
plcDownExtractor's PLC interface went down
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.11.4
afeCpldResetCountafe Cpld Reset Countro
Counter32
.1.3.6.1.4.1.13995.11.5
plcLossCountplc Loss Countro
Counter32
.1.3.6.1.4.1.13995.11.6
resetCountersreset Countersrw
Enumeration
.1.3.6.1.4.1.13995.11.7
optimizationTableIf Injector - This table contains the frequencies(channels) / gains / throughput of all the extractors down stream. If Extractor - This table should contain frequencies(channels) / gains / throughput for the the plc segment between this extractor and the injector/repeator upstream.
SEQUENCE OF OptimizationEntry
.1.3.6.1.4.1.13995.11.8
optimizationEntryRow of table optimizationTable
OptimizationEntry
.1.3.6.1.4.1.13995.11.8.1
extrIpaddressextractor's ipaddressro
IpAddress
.1.3.6.1.4.1.13995.11.8.1.1
extrChannelNumberExtractor Channel Numberro
Integer32
.1.3.6.1.4.1.13995.11.8.1.2
upstreamFreqUpstream Frequencyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13995.11.8.1.3
downstreamFreqDownstream Frequencyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13995.11.8.1.4
rxGainrxGain settingro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13995.11.8.1.5
txGainTx Gain Settingro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13995.11.8.1.6
plcThroughputplcThroughputro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13995.11.8.1.7
upStreamDownStreamThis to indicate if this entry pertains to the upstream segment or the downstream segmentro
Enumeration
.1.3.6.1.4.1.13995.11.8.1.8
gpsInfoGPS co-ordinates. Currently this is a string which means the machine just picks up whatever GPS info is defined in it's system group and sends it to the extractorro
DisplayString
.1.3.6.1.4.1.13995.11.8.1.9
plcEventDescriptionString to be sent in the plc up/down event. Will contain ip address of the unit which just went down or will say 'local system' if current systemro
DisplayString
.1.3.6.1.4.1.13995.11.9
tempGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13995.12
tempFanStateThe fans may be on or off.ro
Enumeration
.1.3.6.1.4.1.13995.12.1
tempFanTargetTempThe target temperature is the average temperature we would like the system to operate at if possible. It is used to calculate how long the fans should stay on during a cycle which is part of a duty cycle algorithm. Temperature is in degrees celsius.rw
Integer32
.1.3.6.1.4.1.13995.12.2
tempHighWarnLimitThe system temperature has exceeded a high temperature warning threshold. Temperature is in degrees Celsius.rw
Integer32
.1.3.6.1.4.1.13995.12.3
tempHighWarnLimitTrapThe system temperature has exceeded the High Warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.12.4
tempEventDescriptionString to be sent with the temperature trap events.ro
DisplayString
.1.3.6.1.4.1.13995.12.5
tempHighErrorLimitTrapThe system temperature has exceeded the High Error Threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.12.6
tempLowWarnLimitTrapThe system temperature has gone below the Low Warning Threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.12.7
tempLowErrorLimitTrapThe system temperature has gone below the Low Error Threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13995.12.8
tempHighErrorLimitThe system temperature has exceeded a high temperature error threshold. Temperature is in degrees Celsius.rw
Integer32
.1.3.6.1.4.1.13995.12.9
tempLowWarnLimitThe system temperature has gone below a low temperature warning threshold. Temperature is in degrees Celscius.rw
Integer32(-100..60) UNITS "degrees Celscius"
.1.3.6.1.4.1.13995.12.10
tempLowErrorLimitThe system temperature has gone below the Low Temperature Error Threshold. The temperature is in degrees Celscius.rw
Integer32(-100..60) UNITS "degrees Celscius"
.1.3.6.1.4.1.13995.12.11
tempHighWarnHistHysteresis value for the High Temperature Warning Condition. Once the system temperature has reached or exceeded the High Temperature Warning threshold, it must go down to or below the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.rw
Integer32(-10..150) UNITS "degrees Celsius"
.1.3.6.1.4.1.13995.12.12
tempHighErrorHistHysteresis value for the High Temperature Error Condition. Once the system temperature has reached or exceeded the High Temperature Error Threshold, it must go down to or below the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.rw
Integer32(-10..150) UNITS "degrees Celscius"
.1.3.6.1.4.1.13995.12.13
tempLowWarnHistHysteresis value for the Low Temperature Warning Condition. Once the system temperature is less than or equal to the LowTemperature Warning threshold, it must go up to or above the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.rw
Integer32(-100..60) UNITS "degrees Celscius"
.1.3.6.1.4.1.13995.12.14
tempLowErrorHistHysteresis value for the Low Temperature Error Condition. Once the system temperature is less than or equal to the LowTemperature Error threshold, it must go up to or above the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.rw
Integer32(-100..60) UNITS "degrees Celsius"
.1.3.6.1.4.1.13995.12.15
tempSystemTempThe temperature of the Main Digital Board. The temperature is obtained by reading a chip located on the digital board.ro
Integer32
.1.3.6.1.4.1.13995.12.16