Amperion-MIB
The Amperion-MIB provides vendor-specific SNMP access for Amperion Inc. network infrastructure, enabling the monitoring of proprietary device metrics such as power consumption, thermal status, and interface statistics. This private MIB extension facilitates granular management of Amperion hardware components that are not covered by standard IETF MIBs.
Imported Objects
Objects
277 total| Object Name |
|---|
amperion MODULE-IDENTITY .1.3.6.1.4.1.13995 |
ds2 OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1 |
powerline OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1 |
plMibIIExtension OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.1 |
plCards OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.1.2 |
plCdNumberro Integer32 .1.3.6.1.4.1.13995.1.1.1.2.1 |
plCdTable SEQUENCE OF PlCdEntry .1.3.6.1.4.1.13995.1.1.1.2.2 |
plCdEntry PlCdEntry .1.3.6.1.4.1.13995.1.1.1.2.2.1 |
plCdIndex Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.1 |
plCdTypero Enumeration .1.3.6.1.4.1.13995.1.1.1.2.2.1.2 |
plCdLinkrw Enumeration .1.3.6.1.4.1.13995.1.1.1.2.2.1.3 |
plCdShortMacAddressrw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.4 |
plCdLongMacAddressro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.5 |
plCdHardwareVersionro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.6 |
plCdFirmwareVersionro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.7 |
plCdDriverVersionro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.8 |
plCdResetrw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.9 |
plCdFactoryResetrw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.10 |
plCdSaveAsPermanentrw Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.11 |
plCdStatusro Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.12 |
plCdRemoteListro DisplayString .1.3.6.1.4.1.13995.1.1.1.2.2.1.13 |
plCdNumRemoteListro Integer32 .1.3.6.1.4.1.13995.1.1.1.2.2.1.14 |
plNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.2 |
plNetTable SEQUENCE OF PlNetEntry .1.3.6.1.4.1.13995.1.1.2.1 |
plNetEntry PlNetEntry .1.3.6.1.4.1.13995.1.1.2.1.1 |
plNetShortMacAddress Integer32 .1.3.6.1.4.1.13995.1.1.2.1.1.1 |
plNetLongMacAddressrw DisplayString .1.3.6.1.4.1.13995.1.1.2.1.1.3 |
plNetRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13995.1.1.2.1.1.8 |
plTransmission OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.3 |
plInpTable SEQUENCE OF PlInpEntry .1.3.6.1.4.1.13995.1.1.3.2 |
plInpEntry PlInpEntry .1.3.6.1.4.1.13995.1.1.3.2.1 |
plInpTotalOctetsro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.1 |
plInpGainrw Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.2 |
plInpAGCrw Enumeration .1.3.6.1.4.1.13995.1.1.3.2.1.3 |
plInpMaxGainrw Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.4 |
plInpThresholdsrw DisplayString .1.3.6.1.4.1.13995.1.1.3.2.1.5 |
plInpAttenuationGainrw Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.6 |
plInpSamsDecodero Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.7 |
plInpSamsGoodro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.8 |
plInpSamsBadro Integer32 .1.3.6.1.4.1.13995.1.1.3.2.1.9 |
plInpNodeTable SEQUENCE OF PlInpNodeEntry .1.3.6.1.4.1.13995.1.1.3.4 |
plInpNodeEntry PlInpNodeEntry .1.3.6.1.4.1.13995.1.1.3.4.1 |
plInpNodeReceivedPktsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.1 |
plInpNodeReceivedUnrecPktsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.2 |
plInpNodeReceivedCorrectedPktsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.3 |
plInpNodeReceivedOctetsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.4 |
plInpNodeReceivedCorrectedOctetsro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.5 |
plInpNodeReceivedPowerro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.6 |
plInpNodePLRro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.7 |
plInpNodeMeanBPCro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.8 |
plInpNodeSNRChangesro Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.9 |
plInpNodeSNRro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.10 |
plInpNodeBPCro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.11 |
plInpNodeCFRro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.12 |
plInpNodeEnableCarriersrw DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.13 |
plInpNodeProtocolEnableCarriersro DisplayString .1.3.6.1.4.1.13995.1.1.3.4.1.14 |
plInpNodeEnableProtocolEnableCarriersrw Integer32 .1.3.6.1.4.1.13995.1.1.3.4.1.15 |
plTraps OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.4 |
plRemoteCPE OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.1.5 |
internal OBJECT IDENTIFIER .1.3.6.1.4.1.13995.1.2 |
amperionSystem OBJECT IDENTIFIER .1.3.6.1.4.1.13995.2 |
serialNumberro DisplayString .1.3.6.1.4.1.13995.2.1 |
partNumberro DisplayString .1.3.6.1.4.1.13995.2.2 |
rombootVersionro DisplayString .1.3.6.1.4.1.13995.2.3 |
alarms SEQUENCE OF AlarmsEntry .1.3.6.1.4.1.13995.2.4 |
alarmsEntry AlarmsEntry .1.3.6.1.4.1.13995.2.4.1 |
alarmIndex Integer32 .1.3.6.1.4.1.13995.2.4.1.1 |
descriptionro DisplayString .1.3.6.1.4.1.13995.2.4.1.2 |
productTypero Enumeration .1.3.6.1.4.1.13995.2.5 |
userGpsInfoStringrw DisplayString .1.3.6.1.4.1.13995.2.6 |
linuxVersionro DisplayString .1.3.6.1.4.1.13995.2.8 |
amperionSysDescrro DisplayString .1.3.6.1.4.1.13995.2.10 |
amperionSysObjectIDro OBJECT IDENTIFIER .1.3.6.1.4.1.13995.2.11 |
amperionSysUpTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.13995.2.12 |
amperionSysContactrw DisplayString .1.3.6.1.4.1.13995.2.13 |
amperionSysNamerw DisplayString .1.3.6.1.4.1.13995.2.14 |
amperionSysLocationrw DisplayString .1.3.6.1.4.1.13995.2.15 |
amperionSysServicesro Integer32 .1.3.6.1.4.1.13995.2.16 |
amperionTrapMgr1rw IpAddress .1.3.6.1.4.1.13995.2.18 |
amperionTrapMgr2rw IpAddress .1.3.6.1.4.1.13995.2.19 |
amperionTrapMgr3rw IpAddress .1.3.6.1.4.1.13995.2.20 |
softwareUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.13995.3 |
serverAddressrw DisplayString .1.3.6.1.4.1.13995.3.1 |
primaryPartitionContentsro DisplayString .1.3.6.1.4.1.13995.3.2 |
currentStatero Enumeration .1.3.6.1.4.1.13995.3.3 |
bootPartitionrw Enumeration .1.3.6.1.4.1.13995.3.4 |
upgradePartitionrw Enumeration .1.3.6.1.4.1.13995.3.5 |
currentPartitionro Enumeration .1.3.6.1.4.1.13995.3.6 |
commandOptionsrw DisplayString .1.3.6.1.4.1.13995.3.7 |
backupPartitionContentsro DisplayString .1.3.6.1.4.1.13995.3.8 |
primaryCRCro Enumeration .1.3.6.1.4.1.13995.3.9 |
backupCRCro Enumeration .1.3.6.1.4.1.13995.3.10 |
lastStatusro DisplayString .1.3.6.1.4.1.13995.3.11 |
filenamerw DisplayString .1.3.6.1.4.1.13995.3.12 |
server1Addressrw DisplayString .1.3.6.1.4.1.13995.3.13 |
server2Addressrw DisplayString .1.3.6.1.4.1.13995.3.14 |
upgradeSchedulerw DisplayString .1.3.6.1.4.1.13995.3.15 |
rebootSchedulerw DisplayString .1.3.6.1.4.1.13995.3.16 |
loginrw DisplayString .1.3.6.1.4.1.13995.3.17 |
passwordrw DisplayString .1.3.6.1.4.1.13995.3.18 |
Amperion-MIB Technical Reference Overview
The Amperion-MIB SNMP MIB module published by Amperion defines 277 managed OID objects, including 206 scalar/column metrics, 11 SNMP tables, and 25 trap/notification events anchored at base OID .1.3.6.1.4.1.13995. Key tabular structures include plCdTable, plNetTable, plInpTable, plInpNodeTable, alarms, amperionifTable. Monitored SNMP traps/notifications include swupgradeCompleted, psImageChecksumError, criticalBatteryShutdownWarning, p12vOutOfRange, m8point5vOutOfRange, p5vOutOfRange.
Key OID Definitions in Amperion-MIB
.1.3.6.1.4.1.13995Amperion Inc. private MIB
.1.3.6.1.4.1.13995.1.1.1.2.2Powerline Cards Table. List of attributes of each Card available in the System. Indexed by the number of the Card (from 1 to plCdNumber).
.1.3.6.1.4.1.13995.1.1.2.1Network Topology. Indexed by number of card and number of remote user (.plCdIndex.cpeId). Maximum values for indexes: plCdNumber and plCdNumRemoteList. Only available in HE.
.1.3.6.1.4.1.13995.1.1.3.2Input Channel Table. Common input characteristics. Indexed by number of card. Maximum value of index: plCdNumber
.1.3.6.1.4.1.13995.1.1.3.4Input Characteristics Remote equipments connected
.1.3.6.1.4.1.13995.2.4Dynamic alarm table - shows all the outstanding alarms on the system
.1.3.6.1.4.1.13995.5.2A list of interface entries. The number of entries is given by the value of ifNumber.
.1.3.6.1.4.1.13995.6.3List of Mac address to be accepted
.1.3.6.1.4.1.13995.7The table of addressing information relevant to this entity's IP addresses.
.1.3.6.1.4.1.13995.8.5List of subscribers
.1.3.6.1.4.1.13995.10.1This entity's IP Routing table.
.1.3.6.1.4.1.13995.11.8If Injector - This table contains the frequencies(channels) / gains / throughput of all the extractors down stream. If Extractor - This table should contain frequencies(channels) / gains / throughput for the the plc segment between this extractor and the injector/repeator upstream.
.1.3.6.1.4.1.13995.3.19swupgradeCompleted
.1.3.6.1.4.1.13995.4.14The power supply is notifying the main digital board that its main image crc is incorrect. The main digital board needs to reprogram the new power supply image again, or revert back to an older good image
.1.3.6.1.4.1.13995.4.15The power supply is warning the main digital board that we have lost AC Line voltage and the battery is running low. The system will be shutting down in seconds. Perform necessary backup.
.1.3.6.1.4.1.13995.4.16The power supply is warning the main digital board that the +12v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware
.1.3.6.1.4.1.13995.4.17The power supply is warning the main digital board that the -8.5v regulator is out of range. Note that the -8.5v regulator is the same regulator as the +12v. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
.1.3.6.1.4.1.13995.4.18The power supply is warning the main digital board that the +5v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
.1.3.6.1.4.1.13995.4.19The power supply is warning the main digital board that the +3.3v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
.1.3.6.1.4.1.13995.4.20The power supply is warning the main digital board that the battery voltage is out of range.
.1.3.6.1.4.1.13995.4.21The power supply is warning the main digital board that the microcontroller unit core temperature is out of range.
.1.3.6.1.4.1.13995.4.22The power supply is warning the main digital board that the battery temperature is out of range
.1.3.6.1.4.1.13995.4.23Power Supply notifies main digital board that it did not communnicate to the power supply within the agreed upon periodic interval
.1.3.6.1.4.1.13995.4.24The power supply is notifying the main digital board that one of the critical requests was aborted due to not receiving it twice in a row.