The AVICI-BAY-MIB facilitates SNMP-based monitoring and management of Avici Bay broadband aggregation routers, exposing critical operational metrics such as subscriber session states, interface traffic counters, CPU utilization, and system temperature sensors. This module enables network operators to track high-volume DSL or cable subscriber aggregation performance and diagnose hardware or link failures within the Avici access infrastructure.
Imported Objects
Objects
100 total| Object Name |
|---|
aviciBayMIB MODULE-IDENTITY .1.3.6.1.4.1.2474.1.4 |
aviciBayObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.1 |
aviciBayTable SEQUENCE OF AviciBayEntry .1.3.6.1.4.1.2474.1.4.1.1 |
aviciBayEntry AviciBayEntry .1.3.6.1.4.1.2474.1.4.1.1.1 |
aviciBayIndexro AviciBayType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.1.1.1 |
aviciBayCriticalLedro AviciLedValue (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.1.1.2 |
aviciBayMajorLedro AviciLedValue (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.1.1.3 |
aviciBayMinorLedro AviciLedValue (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.1.1.4 |
aviciBayAlarmCutOffro Enumeration .1.3.6.1.4.1.2474.1.4.1.1.1.5 |
aviciBayModTempCriticalThresholdro Integer32 .1.3.6.1.4.1.2474.1.4.1.1.1.6 |
aviciBayModTempMajorThresholdro Integer32 .1.3.6.1.4.1.2474.1.4.1.1.1.7 |
aviciBayModTempMinorThresholdro Integer32 .1.3.6.1.4.1.2474.1.4.1.1.1.8 |
aviciBayTempCriticalThresholdro Integer32 .1.3.6.1.4.1.2474.1.4.1.1.1.9 |
aviciBayTempMajorThresholdro Integer32 .1.3.6.1.4.1.2474.1.4.1.1.1.10 |
aviciBayTempMinorThresholdro Integer32 .1.3.6.1.4.1.2474.1.4.1.1.1.11 |
aviciBayControllerTable SEQUENCE OF AviciBayControllerEntry .1.3.6.1.4.1.2474.1.4.1.2 |
aviciBayControllerEntry AviciBayControllerEntry .1.3.6.1.4.1.2474.1.4.1.2.1 |
aviciBayControllerIndexro INTEGER .1.3.6.1.4.1.2474.1.4.1.2.1.1 |
aviciBayControllerOperStatusro Enumeration .1.3.6.1.4.1.2474.1.4.1.2.1.2 |
aviciBayControllerAdminStatusrw Enumeration .1.3.6.1.4.1.2474.1.4.1.2.1.3 |
aviciBayControllerPartNumberro AviciPartNumberType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.2.1.4 |
aviciBayControllerSerialNumberro AviciSerialNumberType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.2.1.5 |
aviciBayControllerRevisionro AviciRevisionType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.2.1.6 |
aviciBayControllerSoftwareVersionro DisplayString .1.3.6.1.4.1.2474.1.4.1.2.1.7 |
aviciBayControllerFirmwareVersionro DisplayString .1.3.6.1.4.1.2474.1.4.1.2.1.8 |
aviciBayControllerProductIdro AviciProductIdType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.2.1.9 |
aviciBayControllerProductSerialNumberro AviciSerialNumberType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.2.1.10 |
aviciBayControllerProductRevisionro AviciRevisionType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.2.1.11 |
aviciBayControllerDescrro DisplayString .1.3.6.1.4.1.2474.1.4.1.2.1.12 |
aviciBayVoltageTable SEQUENCE OF AviciBayVoltageEntry .1.3.6.1.4.1.2474.1.4.1.3 |
aviciBayVoltageEntry AviciBayVoltageEntry .1.3.6.1.4.1.2474.1.4.1.3.1 |
aviciBayVoltageIndexro INTEGER .1.3.6.1.4.1.2474.1.4.1.3.1.1 |
aviciBayVoltageTypero AviciVoltageType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.3.1.2 |
aviciBayVoltagero Integer32 .1.3.6.1.4.1.2474.1.4.1.3.1.3 |
aviciBayVoltageStatusro Enumeration .1.3.6.1.4.1.2474.1.4.1.3.1.4 |
aviciBayVoltageDescrro DisplayString .1.3.6.1.4.1.2474.1.4.1.3.1.5 |
aviciBayFanTable SEQUENCE OF AviciBayFanEntry .1.3.6.1.4.1.2474.1.4.1.4 |
aviciBayFanEntry AviciBayFanEntry .1.3.6.1.4.1.2474.1.4.1.4.1 |
aviciBayFanIndexro INTEGER .1.3.6.1.4.1.2474.1.4.1.4.1.1 |
aviciBayFanAdminStatusro Enumeration .1.3.6.1.4.1.2474.1.4.1.4.1.2 |
aviciBayFanOperStatusro Enumeration .1.3.6.1.4.1.2474.1.4.1.4.1.3 |
aviciBayFanSpeedro Integer32 .1.3.6.1.4.1.2474.1.4.1.4.1.4 |
aviciBayFanCurrTempro Integer32 .1.3.6.1.4.1.2474.1.4.1.4.1.5 |
aviciBayFanMaxTempro Gauge32 .1.3.6.1.4.1.2474.1.4.1.4.1.6 |
aviciBayFanLedStatusro AviciLedValue (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.4.1.7 |
aviciBayFanCurrFailuresro Integer32 .1.3.6.1.4.1.2474.1.4.1.4.1.8 |
aviciBayFanDescrro DisplayString .1.3.6.1.4.1.2474.1.4.1.4.1.9 |
aviciBaySlotTable SEQUENCE OF AviciBaySlotEntry .1.3.6.1.4.1.2474.1.4.1.5 |
aviciBaySlotEntry AviciBaySlotEntry .1.3.6.1.4.1.2474.1.4.1.5.1 |
aviciSlotIndexro AviciSlotType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.5.1.1 |
aviciBaySlotStatusro Enumeration .1.3.6.1.4.1.2474.1.4.1.5.1.2 |
aviciBaySlotRxOctetsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.3 |
aviciBaySlotRxMessagesro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.4 |
aviciBaySlotRxDiscardsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.5 |
aviciBaySlotRxProtoErrsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.6 |
aviciBaySlotRxIOErrsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.7 |
aviciBaySlotRxTimeoutsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.8 |
aviciBaySlotTxOctetsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.9 |
aviciBaySlotTxMessagesro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.10 |
aviciBaySlotTxDiscardsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.11 |
aviciBaySlotTxProtoErrsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.12 |
aviciBaySlotTxIOErrsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.13 |
aviciBaySlotTxTimeoutsro Counter32 .1.3.6.1.4.1.2474.1.4.1.5.1.14 |
aviciBayBreakerTable SEQUENCE OF AviciBayBreakerEntry .1.3.6.1.4.1.2474.1.4.1.6 |
aviciBayBreakerEntry AviciBayBreakerEntry .1.3.6.1.4.1.2474.1.4.1.6.1 |
aviciBayBreakerIndexro Integer32 .1.3.6.1.4.1.2474.1.4.1.6.1.1 |
aviciBayBreakerTypero AviciHighAvailabilityType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.6.1.2 |
aviciBayBreakerStatusro Enumeration .1.3.6.1.4.1.2474.1.4.1.6.1.3 |
aviciBayBreakerDescrro DisplayString .1.3.6.1.4.1.2474.1.4.1.6.1.4 |
aviciBayCoAlarmSystem OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.1.7 |
aviciBayCoActiveAlarmCountro Integer32 .1.3.6.1.4.1.2474.1.4.1.7.1 |
aviciBayCoAlarmLastChangero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.2474.1.4.1.7.2 |
aviciBayCoAlarmTable SEQUENCE OF AviciBayCoAlarmEntry .1.3.6.1.4.1.2474.1.4.1.8 |
aviciBayCoAlarmEntry AviciBayCoAlarmEntry .1.3.6.1.4.1.2474.1.4.1.8.1 |
aviciBayCoAlarmIndexro INTEGER .1.3.6.1.4.1.2474.1.4.1.8.1.1 |
aviciBayCoAlarmTypero Enumeration .1.3.6.1.4.1.2474.1.4.1.8.1.2 |
aviciBayCoAlarmDescrro DisplayString .1.3.6.1.4.1.2474.1.4.1.8.1.3 |
aviciBayCoAlarmTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.2474.1.4.1.8.1.4 |
aviciBayCoAlarmUnitNumro Integer32 .1.3.6.1.4.1.2474.1.4.1.8.1.5 |
aviciBayCoAlarmUnitTypero AviciUnitType (AVICI-TC) .1.3.6.1.4.1.2474.1.4.1.8.1.6 |
aviciBayNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.2 |
aviciBayNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.2.0 |
aviciBayVoltageNotification NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.2.0.1 |
aviciBayFanNotification NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.2.0.2 |
aviciBayBreakerNotification NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.2.0.3 |
aviciBayMultiFanFailures NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.2.0.4 |
aviciBayMultiBayControllerFailures NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.2.0.5 |
aviciBayControllerNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.3 |
aviciBayControllerNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.3.0 |
aviciBayControllerColdStart NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.3.0.1 |
aviciBayControllerWarmStart NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.3.0.2 |
aviciBayControllerDown NOTIFICATION-TYPE .1.3.6.1.4.1.2474.1.4.3.0.3 |
aviciBayMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.4 |
aviciBayMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.4.1 |
aviciBayMIBCompliance Unknown .1.3.6.1.4.1.2474.1.4.4.1.1 |
aviciBayMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2474.1.4.4.2 |
aviciBayGroup Unknown .1.3.6.1.4.1.2474.1.4.4.2.1 |
aviciBayControllerGroup Unknown .1.3.6.1.4.1.2474.1.4.4.2.2 |
aviciBayCentralOfficeGroup Unknown .1.3.6.1.4.1.2474.1.4.4.2.3 |
aviciBayNotificationGroup Unknown .1.3.6.1.4.1.2474.1.4.4.2.4 |
AVICI-BAY-MIB Technical Reference Overview
The AVICI-BAY-MIB SNMP MIB module published by Avici defines 100 managed OID objects, including 68 scalar/column metrics, 7 SNMP tables, and 8 trap/notification events anchored at base OID .1.3.6.1.4.1.2474.1.4. Key tabular structures include aviciBayBreakerTable, aviciBayCoAlarmTable, aviciBayControllerTable, aviciBayFanTable, aviciBaySlotTable, aviciBayTable. Monitored SNMP traps/notifications include aviciBayBreakerNotification, aviciBayControllerColdStart, aviciBayControllerDown, aviciBayControllerWarmStart, aviciBayFanNotification, aviciBayMultiBayControllerFailures.
Key OID Definitions in AVICI-BAY-MIB
.1.3.6.1.4.1.2474.1.4The MIB module for an Avici Bay.
.1.3.6.1.4.1.2474.1.4.1.6This table contains parameters and state variables for the 48-volt breakers at the top of the TSR chassis. There are 4 mains and 4 backups, one pair for each of the 4 shelves.
.1.3.6.1.4.1.2474.1.4.1.8This table contains any currently active central office alarms.
.1.3.6.1.4.1.2474.1.4.1.2This table contains parameters and state variables for the bay controller.
.1.3.6.1.4.1.2474.1.4.1.4This table contains parameters and state variables for blowers. There are up to 4 fans in a shelf installed at the bottom of each bay.
.1.3.6.1.4.1.2474.1.4.1.5This table contains parameters and state variables for the slots.
.1.3.6.1.4.1.2474.1.4.1.1This table contains parameters and state variables for each Avici bay.
.1.3.6.1.4.1.2474.1.4.1.3This table contains parameters and state variables for voltage lines and rails. Each bay contains eight voltage rails used for backplane communication.
.1.3.6.1.4.1.2474.1.4.2.0.3A Breaker notification is sent when the specified breaker has tripped or been manually reset. The breaker may have tripped due to a short circuit, excessive current being drawn, or by an excessively high incoming voltage. This failure is cleared when the breaker is manually reset. If the breaker is manually opened, no trap will be sent.
.1.3.6.1.4.1.2474.1.4.3.0.1The aviciBayControllerColdStart notification signifies that the bay controller has powered-up.
.1.3.6.1.4.1.2474.1.4.3.0.3The aviciBayControllerDown notification signifies that a server is no longer communicating with the bay controller after having established communication.
.1.3.6.1.4.1.2474.1.4.3.0.2The aviciBayControllerWarmStart notification signifies that the bay controller has been restarted.
.1.3.6.1.4.1.2474.1.4.2.0.2A Fan notification is sent when the specified fan detects a fault or clears a fault. The current ambient air temperature entering the fan is reported in the aviciBayFanCurrTemp object. All existing fan faults are reported in the aviciBayFanCurrFailures object as a bitmap. If no failures exist, this object contains a 0. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object. Communication Failure: This failure indicates that the cooling module has been removed or the cooling module firmware is no longer communicating with the bay controller. If a communication failure occurs, the fans will run in autonomous mode until communication with the bay controller is reestablished. Once communication is established, the failure is cleared. General Failure: This failure indicates that the cooling module firmware is able to communicate with the bay controller and is reporting a broken fan. This could mean that the fan is burned out, jammed, or the firmware is unable to sense fan speed due to tachometer failure. When the problem is corrected, the failure is cleared. Filter Blocked: This failure indicates that the fan detected that the filter is blocked. When the obstruction is removed from the filter or the clogged air filter is replaced, this failure will clear. Bad or absent internal thermistor: This failure indicates that the fan internal thermistor is missing or is not functioning. If the thermister is not functioning, the fan cannot sense the incoming ambient air temperature. The ambient temperature is used to control fan speed in autonomous mode and when there are no modules reporting their current temperature. Bad or absent external thermistor: This failure indicates that the fan external thermistor is expected to be installed and is not functioning. Minor temperature threshold: This failure indicates that the incoming ambient air temperature is above the minor threshold temperature, but below the major threshold temperature. Either the cooling system in the building has failed, or it has insufficient cooling capacity for the equipment in the room. A rapid rise in temperature usually indicates cooling system failure whereas a slow rise usually indicates insufficient cooling capacity. When the temperature drops below the minor threshold, this failure will clear. Major temperature threshold: This failure indicates that the incoming ambient air temperature is above the major threshold temperature, but below the critical threshold temperature. Either the cooling system in the building has failed, or it has insufficient cooling capacity for the equipment in the room. A rapid rise in temperature usually indicates cooling system failure whereas a slow rise usually indicates insufficient cooling capacity. When the temperature drops below the major threshold, this failure will clear. Critical temperature threshold: This failure indicates that the incoming ambient air temperature is above the critical threshold temperature. Either the cooling system in the building has failed, or it has insufficient cooling capacity for the equipment in the room. A rapid rise in temperature usually indicates cooling system failure whereas a slow rise usually indicates insufficient cooling capacity. When the temperature drops below the critical threshold, this failure will clear.
.1.3.6.1.4.1.2474.1.4.2.0.5Both bay controllers have failed in this bay.
.1.3.6.1.4.1.2474.1.4.2.0.4Two or more fans have failed in this bay.
.1.3.6.1.4.1.2474.1.4.2.0.1A Voltage notification is sent when a change is detected in the 5 volt backplane communication rails. These backplane communication rails are used by the bay controller to communicate with the occupant of a given slot. There are 8 rails, each servicing the slots in one half of a shelf in the bay (aviciBayVoltageIndex == rail): Rail Slots ============== 1 1 - 5 2 6 - 10 3 11 - 15 4 16 - 20 5 21 - 25 6 26 - 30 7 31 - 35 8 36 - 40 If the voltage is out of specification, the communication path will not function. When a given backplane communication channel is not functioning, modules serviced by this rail cannot be discovered (if a module is inserted) and will not be authorized to boot (if an existing module reboots). The current voltage is reported in the aviciBayVoltage object. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object.
.1.3.6.1.4.1.2474.1.4.4.2.3Objects for the central office.
.1.3.6.1.4.1.2474.1.4.1.7.1The number of current events causing central office alarms in this Avici bay. If there are no such current events, this object contains the value 0
.1.3.6.1.4.1.2474.1.4.1.7.2The value of sysUpTime at the time the aviciBayCoAlarmTable changed.
.1.3.6.1.4.1.2474.1.4.4.2.2Objects for the bayController.
.1.3.6.1.4.1.2474.1.4.4.2.1Objects for the bay.
.1.3.6.1.4.1.2474.1.4.4.1.1The compliance statement for the aviciBay.
.1.3.6.1.4.1.2474.1.4.4.2.4Notifications for the bay.
.1.3.6.1.4.1.2474.1.4.1.1.1.5Central office alarms are triggered by a hardware condition. A write can only use the value off. This turns off the Central Office audible alarms.
More MIBs from Avici
Browse all AviciMIBs →The AVICI-MODULE-MIB defines managed objects for monitoring and controlling forwarding modules within Avici Systems broadband aggregation routers, specifically tracking interface statistics, packet forwarding rates, and hardware module status.
Standard SNMP MIB module defining data structures for AVICI-SONET-MIB.
The AVICI-FABRIC-MIB module provides standard SNMP management capabilities for Avici Systems (now part of Cisco) fabric routers, enabling the monitoring of high-speed switching fabric internal states, port statistics, and line card health metrics.
The AVICI-SYSTEM-MIB provides proprietary management interfaces for Avici Systems broadband routers and aggregation platforms, enabling monitoring of system-level telemetry such as CPU utilization, memory consumption, interface status, and session table statistics. This module facilitates the collection of device health metrics and operational state data required for maintaining high-availability service provider network infrastructure.
The AVICI-SERVER-MIB provides managed objects to monitor and control Avici route servers, specifically tracking BGP session states, routing table statistics, and server operational status for network infrastructure management.
The AVICI-TC MIB module defines the standardized data types and enumerations required for monitoring Avici broadband access routers and their associated session management, interface statistics, and system resources. It serves as the foundational type library for Avici-specific MIBs, ensuring consistent interpretation of counters, gauges, and status codes across the vendor's hardware platform.