ASYNCOS-MAIL-MIB
AI MIB Summary
The ASYNCOS-MAIL-MIB module enables SNMP-based monitoring and management of Cisco IronPort Email Security Appliances, providing access to critical mail flow statistics, queue depths, connection states, and system resource utilization metrics specific to the AsyncOS mail gateway environment.
MIB for Cisco IronPort Mail Gateway/Email Security Appliances
Main OID:
asyncOSMailObjects.1.3.6.1.4.1.15497.1.1.1
64
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
64 total| Object Name |
|---|
asyncOSMailObjectsMIB for Cisco IronPort Mail Gateway/Email Security Appliances MODULE-IDENTITY .1.3.6.1.4.1.15497.1.1.1 |
perCentMemoryUtilizationThis object provides a general idea of how much memory is being consumed by the appliance software.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.1 |
perCentCPUUtilizationThis object provides a general idea of how busy the CPU is according to the appliance software, within the last 5 seconds of utilization. This measurement may or may not reflect the overall CPU utilization of the appliance, and may or may not be a per-process or a per-thread CPU utilization value.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.2 |
perCentDiskIOUtilizationThis object provides a general idea of how much disk I/O has been generated within the last 5-15 seconds.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.3 |
perCentQueueUtilizationPercent of total queue capacity used.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.4 |
queueAvailabilityStatusQueue space status: enough space, queue near full or queue full.ro Enumeration .1.3.6.1.4.1.15497.1.1.1.5 |
resourceConservationReasonReason system is in Resource Conservation Mode.ro Enumeration .1.3.6.1.4.1.15497.1.1.1.6 |
memoryAvailabilityStatusMail Transfer process's memory availability status.ro Enumeration .1.3.6.1.4.1.15497.1.1.1.7 |
powerSupplyTableA table of one or power supply entries. SEQUENCE OF PowerSupplyEntry .1.3.6.1.4.1.15497.1.1.1.8 |
powerSupplyEntryEntry containing the status of a power supply and the corresponding power supply configuration redundancy state. PowerSupplyEntry .1.3.6.1.4.1.15497.1.1.1.8.1 |
powerSupplyIndexUnique index for a power supply source. This index is for SNMP purposes only; it has no intrinsic value.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.8.1.1 |
powerSupplyStatusRepresents the status of a power supply. powerSupplyNotInstalled - The power supply is not detected by the chassis as being physically present. powerSupplyHealthy - The power supply is physically present and is actively servicing the appliance with power. powerSupplyNoAC - The power supply is physically present but is not actively servicing the appliance with power. powerSupplyFaulty - The power supply is failed per the vendor defined operating specifications for the power supply.ro Enumeration .1.3.6.1.4.1.15497.1.1.1.8.1.2 |
powerSupplyRedundancyRepresents the status of a collection of one or more power supplies. powerSupplyRedundancyOK - All power supplies are in a powerSupplyHealthy state. powerSupplyRedundancyLost - One or more power supplies are in a powerSupplyNotInstalled, powerSupplyNoAC, or powerSupplyFaulty state.ro Enumeration .1.3.6.1.4.1.15497.1.1.1.8.1.3 |
powerSupplyNameA textual name for a power supply.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.8.1.4 |
temperatureTableA table of chassis temperature sensor states. SEQUENCE OF TemperatureEntry .1.3.6.1.4.1.15497.1.1.1.9 |
temperatureEntryAn entry in the temperature sensor table representing the status of the corresponding sensor in or on the appliance. TemperatureEntry .1.3.6.1.4.1.15497.1.1.1.9.1 |
temperatureIndexUnique index for the temperature sensor being instrumented. This index is for SNMP purposes only; it has no intrinsic value. Integer32 .1.3.6.1.4.1.15497.1.1.1.9.1.1 |
degreesCelsiusTemperature reading for the sensor being instrumented in Centrigrade units. This is correct according to the relative accuracy of the sensor being instrumented.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.9.1.2 |
temperatureNameTextual description for sensor being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.9.1.3 |
fanTableA table of chassis fan entries. SEQUENCE OF FanEntry .1.3.6.1.4.1.15497.1.1.1.10 |
fanEntryAn entry in the chassis fan table with the speed of a fan in the chassis, as well as the name of the corresponding fan. FanEntry .1.3.6.1.4.1.15497.1.1.1.10.1 |
fanIndexUnique index of the chassis fan being instrumented. This index is for SNMP purposes only; it has no intrinsic value. Integer32 .1.3.6.1.4.1.15497.1.1.1.10.1.1 |
fanRPMsSpeed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow requirements for the appliance it's instrumented in, but in general when fanRPMs reports 0 RPMs the respective fan has failed.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.10.1.2 |
fanNameA textual name of the chassis fan being instrumented.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.10.1.3 |
workQueueMessagesNumber of messages in the work queue.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.11 |
keyExpirationTableA table of Feature Key expiration entries. SEQUENCE OF KeyExpirationEntry .1.3.6.1.4.1.15497.1.1.1.12 |
keyExpirationEntryEntry containing a Feature Key, its expiration status, and whether or not the Feature Key is perpetual. KeyExpirationEntry .1.3.6.1.4.1.15497.1.1.1.12.1 |
keyExpirationIndexUnique index for a Feature Key applicable to the appliance. This index is for SNMP purposes only; it has no intrinsic value.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.12.1.1 |
keyDescriptionTextual description for a Feature Key applicable to the appliance.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.12.1.2 |
keyIsPerpetualBoolean value represented by True if Feature Key is perpetual, or False if the Feature Key is normal or expired.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.12.1.3 |
keySecondsUntilExpireSeconds until the valid Feature Key expires. Only applies to non-perpetual Feature Keys, and is 0 when the Feature Key has expired.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.12.1.4 |
updateTableA table of one or more update entries. SEQUENCE OF UpdateEntry .1.3.6.1.4.1.15497.1.1.1.13 |
updateEntryEntry containing a name and number of successful and failed updates for a service, including but not limited to: spam or virus definitions and timezone updates. UpdateEntry .1.3.6.1.4.1.15497.1.1.1.13.1 |
updateIndexUnique index for an update service. This index is for SNMP purposes only; it has no intrinsic value.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.13.1.1 |
updateServiceNameA textual name for an update entry.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.13.1.2 |
updatesThe number of successful attempts that have occurred when updating a service.ro Counter32 .1.3.6.1.4.1.15497.1.1.1.13.1.3 |
updateFailuresThe number of failed attempts that have occurred when updating a service.ro Counter32 .1.3.6.1.4.1.15497.1.1.1.13.1.4 |
oldestMessageAgeThe number of seconds the oldest message has been in queuero Gauge32 .1.3.6.1.4.1.15497.1.1.1.14 |
outstandingDNSRequestsNumber of DNS requests that have been sent but for which no reply has been received.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.15 |
pendingDNSRequestsNumber of DNS requests waiting to be sent.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.16 |
raidEventsThe total number of RAID events that have occurred since the last appliance power on event.ro Counter32 .1.3.6.1.4.1.15497.1.1.1.17 |
raidTableUnique index for a drive being instrumented in the appliance. This index is for SNMP purposes only; it has no intrinsic value. SEQUENCE OF RaidEntry .1.3.6.1.4.1.15497.1.1.1.18 |
raidEntryAn entry in the RAID table representing the status of a drive attached to a RAID controller in the appliance. RaidEntry .1.3.6.1.4.1.15497.1.1.1.18.1 |
raidIndexUnique index for a drive attached to a RAID controller in the appliance. This index is for SNMP purposes only; it has no intrinsic value.ro Integer32 .1.3.6.1.4.1.15497.1.1.1.18.1.1 |
raidStatusRepresents the status of a a drive attached to a RAID controller in the appliance. driveHealthy - The corresponding drive is connected to the RAID controller and functioning as a healthy member in the RAID volume. driveFailure - The drive is either disconnected from the RAID controller, or has failed to operate within thresholds defined in vendor specifications for the drive and the controller. driveRebuild - The corresponding drive is connected to the RAID controller. It is being rebuilt according to the RAID controller specific rebuild algorithm for the current operating mode of the RAID volume.ro Enumeration .1.3.6.1.4.1.15497.1.1.1.18.1.2 |
raidIDA textual name for a drive attached to a RAID controller in the appliance.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.18.1.3 |
raidLastErrorThe textual description of the last error message reported by the RAID controller or corresponding driver if one has occurred. This is 'No Error' if the corresponding drive's state is driveHealthy, or a controller or driver defined specific textual description if the drive's state is not driveHealthy.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.18.1.4 |
openFilesOrSocketsThis object notes how many files or sockets are open on the appliance. In normal operating conditions, the measurement is taken at least once every 5-15 seconds.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.19 |
mailTransferThreadsNumber of threads that perform some task related to transferring mail.ro Gauge32 .1.3.6.1.4.1.15497.1.1.1.20 |
connectionURLThe URL which will be used to test HTTP URL connectivity.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.21 |
hsmErrorReasonA textual reason describing the last HSM authentication error.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.15497.1.1.1.22 |
asyncOSMailNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.15497.1.1.2 |
resourceConservationModeMemory or queue utilization caused system to enter resource conservation mode. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.1 |
powerSupplyStatusChangeA powerSupplyStatusChange notification is sent when power supply with powerSupplyName changes states, as per one of the states available in powerSupplyStatus. This notification contains the opaque type for powerSupplyName of the power supply which has changed state. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.2 |
highTemperatureA highTemperature notification is sent when the temperature of an instrumented sensor in the chassis has exceeded vendor defined specifications. This notification contains the opaque type for the temperatureName of the sensor which has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.3 |
fanFailureA fanFailure notification is sent when the speed of the fan is not operating per the vendor defined specifications, as discussed in fanRPMs. This notification contains the opaque type for the fanName of the fan which has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.4 |
keyExpirationA keyExpiration notification is sent when the corresponding Feature Key is pending expiration or has expired. This notification contains the opaque type for the keyDescription of the Feature Key that is pending expiration or has expired. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.5 |
updateFailureAn updateFailure notification is sent when a service fails to update properly. This notification contains the opaque type for the updateServiceName of the update service that has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.6 |
raidStatusChangeA raidStatusChange notification is sent when drive with raidID changes states, as per one of the states available in raidStatus. This notification contains the opaque type for raidID of the drive which has changed state. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.7 |
connectivityFailureA connectivityFailure notification is sent when the URL denoted by configured connectionURL is unreachable, or the request returned an HTTP code was not between 200, inclusive, and 300, exclusive. The connectionURL configured is returned when the notification is triggered. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.8 |
memoryUtilizationExceededA memoryUtilizationExceeded notification is sent when the value in perCentMemoryUtilization has exceeded the configured memory usage threshold. The percentage that exceeded the threshold in perCentMemoryUtilization is returned via the notification. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.9 |
cpuUtilizationExceededA cpuUtilizationExceeded notification is sent when the value in perCentCPUUtilization has exceeded the configured CPU usage threshold. The percentage that exceeded the threshold in perCentCPUUtilization is returned via the notification. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.10 |
hsmInitializationFailureA hsmInitializationFailure notification is sent when the Hardware Security Module card cannot be initialized. The initialization error in hsmErrorReason is returned via the notification. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.11 |
hsmResetLoginFailureA hsmResetLoginFailure notification is sent when the Hardware Security Module card is reset due to multiple Crypto Officer login failures. The reset login error in hsmErrorReason is returned via the notification. NOTIFICATION-TYPE .1.3.6.1.4.1.15497.1.1.2.12 |