Home/Catalog/ARISTA-PFC-MIB

ARISTA-PFC-MIB

AI MIB Summary

The ARISTA-PFC-MIB monitors IEEE 802.1Qbb Priority-based Flow Control states and per-class-of-service counters on Arista switches to detect and manage congestion-induced packet drops within specific traffic classes.

Extensions for managing IEEE 802.1Qbb Priority-based Flow Control on Arista devices. This module extends IEEE8021-PFC-MIB by providing per class-of-service information for the supported Arista platforms.
Main OID:
aristaPfcMIB.1.3.6.1.4.1.30065.3.11
13
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

13 total
Object Name
aristaPfcMIBExtensions for managing IEEE 802.1Qbb Priority-based Flow Control on Arista devices. This module extends IEEE8021-PFC-MIB by providing per class-of-service information for the supported Arista platforms.
MODULE-IDENTITY
.1.3.6.1.4.1.30065.3.11
aristaPfc
OBJECT IDENTIFIER
.1.3.6.1.4.1.30065.3.11.1
aristaPfcPriorityTableThis table contains the per class-of-service priority-flow-control information of an interface.
SEQUENCE OF AristaPfcPriorityEntry
.1.3.6.1.4.1.30065.3.11.1.1
aristaPfcPriorityEntryA list of attributes of each ingress class-of-service of an interface.
AristaPfcPriorityEntry
.1.3.6.1.4.1.30065.3.11.1.1.1
aristaPfcIfIndexThe interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.30065.3.11.1.1.1.1
aristaPfcPriorityIndexThe Ethernet class-of-service index for accessing the per-priority information of an interface.
AristaPfcCOSIndex
.1.3.6.1.4.1.30065.3.11.1.1.1.2
aristaPfcPriorityRequestsA count of the invoked PFC M_CONTROL.request primitives with this priority class asserted. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.ro
Counter64 UNITS "Requests"
.1.3.6.1.4.1.30065.3.11.1.1.1.3
aristaPfcPriorityIndicationsA count of the received PFC M_CONTROL.indication primitives with this priority class asserted. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.ro
Counter64 UNITS "Indications"
.1.3.6.1.4.1.30065.3.11.1.1.1.4
aristaPfcConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.30065.3.11.2
aristaPfcCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.30065.3.11.2.1
aristaPfcComplianceThe compliance statement for Arista switches that support Priority Flow Control (PFC).
Unknown
.1.3.6.1.4.1.30065.3.11.2.1.1
aristaPfcGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.30065.3.11.2.2
aristaPfcGroupThe group of required PFC objects.
Unknown
.1.3.6.1.4.1.30065.3.11.2.2.1