APNL-MODULAR-PDU-MIB
AI MIB Summary
The APNL-MODULAR-PDU-MIB enables SNMP-based monitoring and management of AP Nederland modular Power Distribution Units (PDUs), providing access to granular metrics including per-outlet power consumption, voltage, current, temperature, and individual outlet status states.
This MIB module defines the modular PDU version of AP Nederland.
Main OID:
apNederland.1.3.6.1.4.1.29640
89
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
89 total| Object Name |
|---|
apNederlandThis MIB module defines the modular PDU version of AP Nederland. MODULE-IDENTITY .1.3.6.1.4.1.29640 |
apnlDirectory OBJECT IDENTIFIER .1.3.6.1.4.1.29640.1 |
apnlMib OBJECT IDENTIFIER .1.3.6.1.4.1.29640.2 |
apnlTmp OBJECT IDENTIFIER .1.3.6.1.4.1.29640.3 |
apnlModules OBJECT IDENTIFIER .1.3.6.1.4.1.29640.4 |
cm OBJECT IDENTIFIER .1.3.6.1.4.1.29640.4.1 |
cmTraps OBJECT IDENTIFIER .1.3.6.1.4.1.29640.4.2 |
pdu OBJECT IDENTIFIER .1.3.6.1.4.1.29640.4.3 |
pduTypeType of the Pdu. PduModular (0) Modulaire OEC2 PDU communication through SNMPV3, MOD-BUS or AP-BUS in emulation mode. PduGateway1 (1) Gateway to connect OEC1 products with external AP-BUS protocol to OEC2 Manager (SNMPV3). PduGateway2 (2) Gateway to connect OEC2 products with external MOD-BUS to OEC Manager (SNMPV3).ro Enumeration .1.3.6.1.4.1.29640.4.3.1 |
pduProductIdentifierUnique serial number to identify a pdu, the number is between 1 and 65535.ro Integer32 .1.3.6.1.4.1.29640.4.3.2 |
pduSerialNumberPDU onboard Serial Number.ro DisplayString .1.3.6.1.4.1.29640.4.3.3 |
pduStatusStatus of the Pdu. pduBusy (0) Indicates that an admin command is in progress. pduReady (1) The execution of an admin command was successfull. pduAlarm (2) This state is not in use. pduError (3) The execution of an admin command failed.ro Enumeration .1.3.6.1.4.1.29640.4.3.4 |
pduPowerThe total measured pdu power in Kilo Watt's*Hour.ro Unsigned32 UNITS "kiloWattHours" .1.3.6.1.4.1.29640.4.3.5 |
pduPowerL1The total measured pdu power in Kilo Watt's*Hour for phase 1.ro Unsigned32 UNITS "kiloWattHours" .1.3.6.1.4.1.29640.4.3.6 |
pduPowerL2The total measured pdu power in Kilo Watt's*Hour for phase 2.ro Unsigned32 UNITS "kiloWattHours" .1.3.6.1.4.1.29640.4.3.7 |
pduPowerL3The total measured pdu power in Kilo Watt's*Hour for phase 3.ro Unsigned32 UNITS "kiloWattHours" .1.3.6.1.4.1.29640.4.3.8 |
pduKvarThe total Reactive Power of the pdu. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.ro Unsigned32 UNITS "KiloWattHours" .1.3.6.1.4.1.29640.4.3.9 |
pduKvarL1The total Reactive Power of the pdu for phase 1. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.ro Unsigned32 UNITS "KiloWattHours" .1.3.6.1.4.1.29640.4.3.10 |
pduKvarL2The total Reactive Power of the pdu for phase 2. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.ro Unsigned32 UNITS "KiloWattHours" .1.3.6.1.4.1.29640.4.3.11 |
pduKvarL3The total Reactive Power of the pdu for phase 3. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.ro Unsigned32 UNITS "KiloWattHours" .1.3.6.1.4.1.29640.4.3.12 |
pdulAcurrentThe total measured ac current for the pdu (in 1/10th Amperes) .ro Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.13 |
pduAcurrentL1The total measured ac current for phase 1 (in 1/10th Amperes).ro Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.14 |
pduAcurrentL2The total measured ac current for phase 2 (in 1/10th Amperes).ro Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.15 |
pduAcurrentL3The total measured ac current for phase 3 (in 1/10th Amperes).ro Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.16 |
pduCurIpAddressThe current PDU IPv4 Address by which TCP/IP access is available.ro IpAddress UNITS "IPv4 Addr" .1.3.6.1.4.1.29640.4.3.17 |
pduCurSubNetMaskThe current PDU IPv4 Subnet Mask used by the Ipstack (e.g: 255.255.255.0).ro IpAddress UNITS "IPv4 Addr" .1.3.6.1.4.1.29640.4.3.18 |
pduCurDefGwAddressThe current PDU IPv4 default gateway address used by the Ipstack (e.g: 192.168.1.1).ro IpAddress UNITS "IPv4 Addr" .1.3.6.1.4.1.29640.4.3.19 |
pduNumberOfNodesNumber of items in the node table.ro Integer32 .1.3.6.1.4.1.29640.4.3.20 |
pduNumberOfSensorsNumber of items in the sensor table.ro Integer32 .1.3.6.1.4.1.29640.4.3.21 |
pduSoftwareVersionPDU software version number.ro DisplayString .1.3.6.1.4.1.29640.4.3.22 |
pduFirmwareVersionPDU firmware version number.ro DisplayString .1.3.6.1.4.1.29640.4.3.23 |
pduBusProtocolSelected protocol used on the external bus of the pdu. AP-BUS (0) Protocol used by OEC1 products or by OEC2 products in emulation mode. MOD-BUS (1) Protocol used by OEC2 products.ro Enumeration .1.3.6.1.4.1.29640.4.3.24 |
pduAdminCommandPDU admin management Commands: noOp (0) No operation. rebootPdu (1) Reboot the PDU (to execute new settings). rediscover (2) Not supported. updateSofware (3) Not supported. resetConfig (4) Node and group tables will be cleared . resetSNMPv3Config (5) Not supported. resetNetworkSetting (6) Reset network params: ip address, defualt gatewy, subnet mask. readDataFromBusPdu (7) Read data from a PDU connected to the external bus (address is set in pduBusAddress). writeDataToBusPdu (8) With this command modified data is writen back to the bus PDU (address is set in pduBusAddress).rw Enumeration .1.3.6.1.4.1.29640.4.3.25 |
pduStartupIpAddressNot supported.rw IpAddress UNITS "IPv4 Addr" .1.3.6.1.4.1.29640.4.3.26 |
pduStartupSubNetMaskNot supported.rw IpAddress UNITS "IPv4 Addr" .1.3.6.1.4.1.29640.4.3.27 |
pduStartupDefGwAddressNot supported.rw IpAddress UNITS "IPv4 Addr" .1.3.6.1.4.1.29640.4.3.28 |
pduRealTimeClockPDU Real-Time Clock. Maybe set by the manager.rw DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.29640.4.3.29 |
pduEnableFeaturesArray of bits each one an specific feature within the pdu: globalWebEnabled (0) This bit enables the PDU webpages. globalUsbEnabled (1) This bit enables the USB menu. globalSwitchEnabled (2) This bit enables switching in general. displaySwitchEnabled (3) This bit enables switching through the presentation module. webSwitchEnabled (4) This bit enables switching throuhg the web inteface.rw Bits .1.3.6.1.4.1.29640.4.3.30 |
pduBusAddressAddress used to access this PDU via the external bus. When MOD-BUS protocol is used the address is valid between 1-247. When AP-BUS protocol is used the address is valid between 1-65535.rw Integer32 .1.3.6.1.4.1.29640.4.3.31 |
pduNameName of the PDU.rw DisplayString .1.3.6.1.4.1.29640.4.3.32 |
nodeTableA table of the modules on the PDU. Each entry represents an module unit. SEQUENCE OF NodeEntry .1.3.6.1.4.1.29640.4.3.33 |
nodeEntryAn port entry in the port table. NodeEntry .1.3.6.1.4.1.29640.4.3.33.1 |
nodeIndexThe node table Index. Unsigned32 .1.3.6.1.4.1.29640.4.3.33.1.1 |
nodeTypeType of the node. TypeUnknown (0) Unknown node. TypePresModChar (1) PM LCD Character Module. TypePresModMono (2) PM Mono Graphics Module. TypePresModGraph (3) PM Color Graphics Module. TypePowerMeter (4) Power meter. TypePowerMeterSwitch (5) Switchable power meter. TypeSwitch (6) Switch only.ro Enumeration .1.3.6.1.4.1.29640.4.3.33.1.2 |
nodeOutletThe number associated with the physical outlet of the node. The special value of 0 indicates that this entry is not associated with a physical port.ro Unsigned32 .1.3.6.1.4.1.29640.4.3.33.1.3 |
nodeAlarmStatusArray of bits each one indicates an alarm activated in the alarm selector value. TrapCurrHi (0) The current is to high against the high current threshold. TrapCurrLo (1) The current is to low against the low current threshold. TrapVoltHi (2) The voltage is to high against the high voltage threshold. TrapVoltLo (3) The volage is to low against the low voltage threshold. SwitchOn (4) The switch is on against the switch on bitfield. SwitchOff (5) The switch is off against the switch off bitfield.ro Bits .1.3.6.1.4.1.29640.4.3.33.1.4 |
nodePowerThe measured node power in Kilo Watt's*Hour.ro Unsigned32 UNITS "kiloWattHours" .1.3.6.1.4.1.29640.4.3.33.1.5 |
nodeAcurrentThe measured ac current at the node (in 1/10th Amperes).ro Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.33.1.6 |
nodePeakCurrentThe measured max current since last reset of the node (in 1/10th Amperes).ro Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.33.1.7 |
nodeVoltageThe measured voltage on the node.ro Unsigned32 UNITS "Volts" .1.3.6.1.4.1.29640.4.3.33.1.8 |
nodeMinVoltageThe measured minimum voltage at the node since last reset.ro Unsigned32 UNITS "Volts" .1.3.6.1.4.1.29640.4.3.33.1.9 |
nodeKvarThe Reactive Power. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.ro Unsigned32 UNITS "KiloWattHours" .1.3.6.1.4.1.29640.4.3.33.1.10 |
nodeFrequencyThe frequency of alternating current in Hertz. e.g 50 in Europe or 60 in USA.ro Unsigned32 UNITS "Hertz" .1.3.6.1.4.1.29640.4.3.33.1.11 |
nodePowerFactorThe effective power facton (Cosinus Phi) in percents of the node.ro Unsigned32 UNITS "Percent" .1.3.6.1.4.1.29640.4.3.33.1.12 |
nodeSwitchOperStatusThe actual operational Status of the node. Unknown (0) not known status. Off (1) switch is off. On (2) switch is on.ro Enumeration .1.3.6.1.4.1.29640.4.3.33.1.13 |
nodeSwitchAdminStatusThe desired admin Status of the switch. Unknown (0) not known. Off (1) switch is off. On (2) switch is on.rw Enumeration .1.3.6.1.4.1.29640.4.3.33.1.14 |
nodeCurrHiThreshThe current high threshold (in 1/10th Amperes).rw Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.33.1.15 |
nodeCurrLoThreshThe current low threshold (in 1/10th Amperes).rw Unsigned32 UNITS "DeciAmpers" .1.3.6.1.4.1.29640.4.3.33.1.16 |
nodeVoltHiThreshThe voltage high threshold.rw Unsigned32 UNITS "Volts" .1.3.6.1.4.1.29640.4.3.33.1.17 |
nodeVoltLoThreshThe voltage low threshold.rw Unsigned32 UNITS "Volts" .1.3.6.1.4.1.29640.4.3.33.1.18 |
nodeAlarmSelectorArray of bits each one controls one alarm. TrapCurrHi (0) Enable/disable the high current alarm. TrapCurrLo (1) Enable/disable the low current alarm. TrapVoltHi (2) Enable/disable the high voltage alarm. TrapVoltLo (3) Enable/disable the low voltage alarm. SwitchOn (4) Enable/disable the specific switch on alarm. SwitchOff (5) Enable/disable the specific switch off alarm.rw Bits .1.3.6.1.4.1.29640.4.3.33.1.19 |
nodeNameThe node name. My be set by manager.rw DisplayString .1.3.6.1.4.1.29640.4.3.33.1.20 |
nodePhaseThe measured phase of the node. Maybe assigned when not configured in production. PhaseUnknown (0). PhaseL1 (1). PhaseL2 (2). PhaseL3 (3).rw Enumeration .1.3.6.1.4.1.29640.4.3.33.1.21 |
sensorTableA table of the Sensors on the PDU. Each entry represents an an Sensor unit. SEQUENCE OF SensorEntry .1.3.6.1.4.1.29640.4.3.34 |
sensorEntryAn Sensor Entry in the Sensor table SensorEntry .1.3.6.1.4.1.29640.4.3.34.1 |
sensorIndexThe Sensor table Index. Unsigned32 .1.3.6.1.4.1.29640.4.3.34.1.1 |
sensorTypeSensor Typ: Measured values are used according to sensor type. Other (0) unknown sensor type. Temperature (1) . Humidity (2). Smoke (3). CO1 (4). Vibration (5). Doorstatus (6).ro Enumeration .1.3.6.1.4.1.29640.4.3.34.1.2 |
sensorAlarmStatusArray of bits each one indicates an alarm activated in the alarm selector value.ro Bits .1.3.6.1.4.1.29640.4.3.34.1.3 |
sensorValueThe measured value of the sensor, units are depending on sensor type.ro Integer32 UNITS "by type" .1.3.6.1.4.1.29640.4.3.34.1.4 |
sensorSwitchOperStatusThe actual operational Status of the switch.ro Enumeration .1.3.6.1.4.1.29640.4.3.34.1.5 |
sensorSwitchAdminStatusThe desired admin Status of the switch.rw Enumeration .1.3.6.1.4.1.29640.4.3.34.1.6 |
sensorHiThreshHigh threshold.rw Integer32 UNITS "by type" .1.3.6.1.4.1.29640.4.3.34.1.7 |
sensorLoThreshLow threshold.rw Integer32 UNITS "by type" .1.3.6.1.4.1.29640.4.3.34.1.8 |
sensorAlarmSelectorArray of bits each one controls one alarm. E.g trap, beeper etc.rw Bits .1.3.6.1.4.1.29640.4.3.34.1.9 |
sensorNameThe sensor name. May be set by the manager.rw DisplayString .1.3.6.1.4.1.29640.4.3.34.1.10 |
pduTraps OBJECT IDENTIFIER .1.3.6.1.4.1.29640.4.4 |
trapTypeAn enumation value to indicate an Alarm trap: pduPduAlarm.ro Enumeration .1.3.6.1.4.1.29640.4.4.1 |
pduTableTypeThe table type.ro Enumeration .1.3.6.1.4.1.29640.4.4.2 |
trapTableIndexThe index of the table entry for which the trap is issued.ro Integer32 .1.3.6.1.4.1.29640.4.4.3 |
trapThreshHoldTypeThe threshold type for which the trap is made.ro Enumeration .1.3.6.1.4.1.29640.4.4.4 |
trapThreshHoldThe threshold reference value.ro Integer32 .1.3.6.1.4.1.29640.4.4.5 |
pduVoltageAlarmVoltage alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.29640.4.4.6 |
pduCurrentAlarmCurrent alaram. NOTIFICATION-TYPE .1.3.6.1.4.1.29640.4.4.7 |
pduPowerAlarmPower alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.29640.4.4.8 |
sensorAlarmSensor Alarm: Temperature, Humidity or another type. The sensorType indicates the type of alarm. The sensorValue indicate the measured value. NOTIFICATION-TYPE .1.3.6.1.4.1.29640.4.4.9 |
pduSwitchAlarmNot supported. NOTIFICATION-TYPE .1.3.6.1.4.1.29640.4.4.10 |
apnlTest OBJECT IDENTIFIER .1.3.6.1.4.1.29640.5 |
apnlDemo OBJECT IDENTIFIER .1.3.6.1.4.1.29640.6 |