ALTIGA-HARDWARE-STATS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ALTIGA-HARDWARE-STATS-MIB.

70
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

70 total
Object Name
altigaHardwareStatsMibModule
OBJECT IDENTIFIER
.1.3.6.1.4.1.3076.1.1.27.2
RFC1155-SMI
Unknown
.1.3.6.1.4.1.3076.1.1.27.2
altigaHardwareStatsMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.3076.1.1.27.2.1
altigaHardwareStatsMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.3076.1.1.27.2.1.1
altigaHardwareStatsMibCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.3076.1.1.27.2.1.1.1
altigaHardwareStatsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.3076.2.1.1.1.22.2
alStatsHardwareGlobal
OBJECT IDENTIFIER
.1.3.6.1.4.1.3076.2.1.2.22.1
alHardwareCpuVoltagero
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.1
alHardwareCpuVoltageAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.2
alHardwareCpuVoltageCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.3
alHardwareCpuVoltageTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.4
alHardwarePs1Voltage3vro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.5
alHardwarePs1Voltage3vAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.6
alHardwarePs1Voltage3vCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.7
alHardwarePs1Voltage3vTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.8
alHardwarePs1Voltage5vro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.9
alHardwarePs1Voltage5vAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.10
alHardwarePs1Voltage5vCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.11
alHardwarePs1Voltage5vTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.12
alHardwarePs2Voltage3vro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.13
alHardwarePs2Voltage3vAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.14
alHardwarePs2Voltage3vCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.15
alHardwarePs2Voltage3vTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.16
alHardwarePs2Voltage5vro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.17
alHardwarePs2Voltage5vAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.18
alHardwarePs2Voltage5vCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.19
alHardwarePs2Voltage5vTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.20
alHardwareBoardVoltage3vro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.21
alHardwareBoardVoltage3vAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.22
alHardwareBoardVoltage3vCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.23
alHardwareBoardVoltage3vTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.24
alHardwareBoardVoltage5vro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.25
alHardwareBoardVoltage5vAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.26
alHardwareBoardVoltage5vCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.27
alHardwareBoardVoltage5vTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.28
alHardwareCpuTempro
INTEGER(-40..120) -- Units -- degrees Celsius
.1.3.6.1.4.1.3076.2.1.2.22.1.29
alHardwareCpuTempAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.30
alHardwareCpuTempCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.31
alHardwareCpuTempTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.32
alHardwareCageTempro
INTEGER(-40..120) -- Units -- degrees Celsius
.1.3.6.1.4.1.3076.2.1.2.22.1.33
alHardwareCageTempAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.34
alHardwareCageTempCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.35
alHardwareCageTempTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.36
alHardwareFan1Rpmro
Gauge -- Units -- RPM
.1.3.6.1.4.1.3076.2.1.2.22.1.37
alHardwareFan1RpmAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.38
alHardwareFan1RpmCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.39
alHardwareFan1RpmTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.40
alHardwareFan2Rpmro
Gauge -- Units -- RPM
.1.3.6.1.4.1.3076.2.1.2.22.1.41
alHardwareFan2RpmAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.42
alHardwareFan2RpmCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.43
alHardwareFan2RpmTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.44
alHardwareFan3Rpmro
Gauge -- Units -- RPM
.1.3.6.1.4.1.3076.2.1.2.22.1.45
alHardwareFan3RpmAlarmro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.46
alHardwareFan3RpmCountro
Counter
.1.3.6.1.4.1.3076.2.1.2.22.1.47
alHardwareFan3RpmTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3076.2.1.2.22.1.48
alHardwarePs1Typero
Enumeration
.1.3.6.1.4.1.3076.2.1.2.22.1.49
alHardwarePs2Typero
Enumeration
.1.3.6.1.4.1.3076.2.1.2.22.1.50
alHardwareSlot1Cardro
ConcentratorCard -- Rsyntax INTEGER { -- none(1), -- sep(2), -- dualT1Wan(3) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.51
alHardwareSlot2Cardro
ConcentratorCard -- Rsyntax INTEGER { -- none(1), -- sep(2), -- dualT1Wan(3) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.52
alHardwareSlot3Cardro
ConcentratorCard -- Rsyntax INTEGER { -- none(1), -- sep(2), -- dualT1Wan(3) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.53
alHardwareSlot4Cardro
ConcentratorCard -- Rsyntax INTEGER { -- none(1), -- sep(2), -- dualT1Wan(3) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.54
alHardwareSlot1Operationalro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.55
alHardwareSlot2Operationalro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.56
alHardwareSlot3Operationalro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.57
alHardwareSlot4Operationalro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.58
alHardwareRamSizero
Gauge -- Units -- MB
.1.3.6.1.4.1.3076.2.1.2.22.1.59
alHardwareChassisro
ConcentratorType -- Rsyntax INTEGER { -- cxx(1), -- c5(2), -- c1(3) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.60
alHardwareCpuVoltageNominalro
Gauge -- Units -- centivolts
.1.3.6.1.4.1.3076.2.1.2.22.1.61
alHardwareClientEthPrivSwitchro
TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- }
.1.3.6.1.4.1.3076.2.1.2.22.1.62
alHardwareSerialNumberro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.3076.2.1.2.22.1.63

ALTIGA-HARDWARE-STATS-MIB Technical Reference Overview

The ALTIGA-HARDWARE-STATS-MIB SNMP MIB module published by Altiga defines 70 managed OID objects, including 64 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events.

Key OID Definitions in ALTIGA-HARDWARE-STATS-MIB

alHardwareCpuVoltageGaugeread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.1

The current CPU voltage in centivolts.

alHardwareCpuVoltageAlarmTruthValueread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.2

The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range.

alHardwareCpuVoltageCountCounterread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.3

The number of alarm events for CPU voltage.

alHardwareCpuVoltageTimeTimeTicksread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.4

The sysUptime at the time of the last change of alarm status for CPU voltage.

alHardwarePs1Voltage3vGaugeread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.5

The current 3V voltage of Power Supply 1 in centivolts.

alHardwarePs1Voltage3vAlarmTruthValueread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.6

The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range.

alHardwarePs1Voltage3vCountCounterread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.7

The number of alarm events for PS1 3v voltage.

alHardwarePs1Voltage3vTimeTimeTicksread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.8

The sysUptime at the time of the last change of alarm status for PS1 3v voltage.

alHardwarePs1Voltage5vGaugeread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.9

The current 5V voltage of Power Supply 1 in centivolts.

alHardwarePs1Voltage5vAlarmTruthValueread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.10

The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range.

alHardwarePs1Voltage5vCountCounterread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.11

The number of alarm events for PS1 5v voltage.

alHardwarePs1Voltage5vTimeTimeTicksread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.12

The sysUptime at the time of the last change of alarm status for PS1 5v voltage.

alHardwarePs2Voltage3vGaugeread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.13

The current 3V voltage of Power Supply 2 in centivolts.

alHardwarePs2Voltage3vAlarmTruthValueread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.14

The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range.

alHardwarePs2Voltage3vCountCounterread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.15

The number of alarm events for PS2 3v voltage.

alHardwarePs2Voltage3vTimeTimeTicksread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.16

The sysUptime at the time of the last change of alarm status for PS2 3v voltage.

alHardwarePs2Voltage5vGaugeread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.17

The current 5V voltage of Power Supply 2 in centivolts.

alHardwarePs2Voltage5vAlarmTruthValueread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.18

The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range.

alHardwarePs2Voltage5vCountCounterread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.19

The number of alarm events for PS2 5v voltage.

alHardwarePs2Voltage5vTimeTimeTicksread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.20

The sysUptime at the time of the last change of alarm status for PS2 5v voltage.

alHardwareBoardVoltage3vGaugeread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.21

The current 3V voltage of the mainboard in centivolts.

alHardwareBoardVoltage3vAlarmTruthValueread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.22

The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range.

alHardwareBoardVoltage3vCountCounterread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.23

The number of alarm events for the mainboard 3v voltage.

alHardwareBoardVoltage3vTimeTimeTicksread-only
.1.3.6.1.4.1.3076.2.1.2.22.1.24

The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage.

More MIBs from Altiga

Browse all AltigaMIBs →
ALTIGA-MIB

The ALTIGA-MIB provides SNMP management access to counters and operational objects for Alte Networks (formerly NetScreen/Alteon) Altiga application delivery controllers and web acceleration appliances. It enables monitoring of device-specific performance metrics, including traffic throughput, connection session states, and hardware resource utilization for these legacy application delivery platforms.

255 objects→
ALTIGA-SESSION-STATS-MIB

Standard SNMP MIB module defining data structures for ALTIGA-SESSION-STATS-MIB.

134 objects→
ALTIGA-L2TP-STATS-MIB

The ALTIGA-L2TP-STATS-MIB provides vendor-specific monitoring for Altiga L2TP Access Concentrators (LAC) and Network Servers (LNS) by exposing granular counters for Layer 2 Tunnel Protocol session states, Attribute/Value Pair (AVP) exchanges, and tunnel throughput metrics. This module enables the tracking of critical L2TP operational parameters, including Calling Line ID (CLID) and Dialed Number Identification Service (DNIS) associations, to facilitate precise troubleshooting of tunnel establishment failures and data transfer anomalies.

105 objects→
ALTIGA-GLOBAL-REG

Standard SNMP MIB module defining data structures for ALTIGA-GLOBAL-REG.

73 objects→
ALTIGA-PPTP-STATS-MIB

The ALTIGA-PPTP-STATS-MIB provides SNMP-manageable counters for monitoring Point-to-Point Tunneling Protocol (PPTP) tunnel statistics on Altiga network appliances. This module enables the tracking of tunnel session states, throughput metrics, and error conditions specific to the Altiga PPTP implementation.

69 objects→
ALTIGA-TELNET-STATS-MIB

Standard SNMP MIB module defining data structures for ALTIGA-TELNET-STATS-MIB.

51 objects→