ALGPOWER-v2-MIB
Standard SNMP MIB module defining data structures for ALGPOWER-v2-MIB.
Imported Objects
Objects
59 total| Object Name |
|---|
algcom OBJECT IDENTIFIER .1.3.6.1.4.1.49136 |
RFC1213-MIB Unknown .1.3.6.1.4.1.49136 |
upsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1 |
output OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.1 |
outputVoltagero INTEGER .1.3.6.1.4.1.49136.1.1.1 |
outputCurrentro INTEGER .1.3.6.1.4.1.49136.1.1.2 |
oidNotUsed0ro INTEGER .1.3.6.1.4.1.49136.1.1.3 |
oidNotUsed1ro INTEGER .1.3.6.1.4.1.49136.1.1.4 |
battery OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.2 |
batteryVoltagero INTEGER .1.3.6.1.4.1.49136.1.2.1 |
batteryCurrentro INTEGER .1.3.6.1.4.1.49136.1.2.2 |
chargerStatusro INTEGER .1.3.6.1.4.1.49136.1.2.3 |
input OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.3 |
alarmOnBatteryro INTEGER .1.3.6.1.4.1.49136.1.3.1 |
acFailro INTEGER .1.3.6.1.4.1.49136.1.3.2 |
batteryChargingro INTEGER .1.3.6.1.4.1.49136.1.3.3 |
batteryDischargingro INTEGER .1.3.6.1.4.1.49136.1.3.4 |
overheatro INTEGER .1.3.6.1.4.1.49136.1.3.5 |
overloadro INTEGER .1.3.6.1.4.1.49136.1.3.6 |
fanAfailro INTEGER .1.3.6.1.4.1.49136.1.3.7 |
fanBfailro INTEGER .1.3.6.1.4.1.49136.1.3.8 |
oidNotUsed2ro INTEGER .1.3.6.1.4.1.49136.1.3.9 |
oidNotUsed3ro INTEGER .1.3.6.1.4.1.49136.1.3.10 |
upTimero INTEGER .1.3.6.1.4.1.49136.1.3.11 |
temperature OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.4 |
innerTemperaturero INTEGER .1.3.6.1.4.1.49136.1.4.1 |
outerTemperaturero INTEGER .1.3.6.1.4.1.49136.1.4.2 |
heatSinkTemperaturero INTEGER .1.3.6.1.4.1.49136.1.4.3 |
watchdog OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.5 |
watchdogPing1ro INTEGER .1.3.6.1.4.1.49136.1.5.1 |
watchdogPing2ro INTEGER .1.3.6.1.4.1.49136.1.5.2 |
watchdogPing3ro INTEGER .1.3.6.1.4.1.49136.1.5.3 |
watchdogPing4ro INTEGER .1.3.6.1.4.1.49136.1.5.4 |
watchdogPing5ro INTEGER .1.3.6.1.4.1.49136.1.5.5 |
watchdogPing6ro INTEGER .1.3.6.1.4.1.49136.1.5.6 |
watchdogPing7ro INTEGER .1.3.6.1.4.1.49136.1.5.7 |
watchdogPing8ro INTEGER .1.3.6.1.4.1.49136.1.5.8 |
watchdogPing9ro INTEGER .1.3.6.1.4.1.49136.1.5.9 |
watchdogPing10ro INTEGER .1.3.6.1.4.1.49136.1.5.10 |
supply OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.6 |
supplyVoltagero INTEGER .1.3.6.1.4.1.49136.1.6.1 |
installation OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.7 |
popNamero DisplayString .1.3.6.1.4.1.49136.1.7.1 |
facilityAddrro DisplayString .1.3.6.1.4.1.49136.1.7.2 |
facilityCityro DisplayString .1.3.6.1.4.1.49136.1.7.3 |
instDatero DisplayString .1.3.6.1.4.1.49136.1.7.4 |
batCapacityro INTEGER .1.3.6.1.4.1.49136.1.7.5 |
batBrandro DisplayString .1.3.6.1.4.1.49136.1.7.6 |
batInstDatero DisplayString .1.3.6.1.4.1.49136.1.7.7 |
respPersro DisplayString .1.3.6.1.4.1.49136.1.7.8 |
bat-tst OBJECT IDENTIFIER .1.3.6.1.4.1.49136.1.8 |
btst-datero DisplayString .1.3.6.1.4.1.49136.1.8.1 |
btst-statusro INTEGER .1.3.6.1.4.1.49136.1.8.2 |
btst-durationro INTEGER .1.3.6.1.4.1.49136.1.8.3 |
btst-elapsedro INTEGER .1.3.6.1.4.1.49136.1.8.4 |
btst-volt-iro INTEGER .1.3.6.1.4.1.49136.1.8.5 |
btst-amp-iro INTEGER .1.3.6.1.4.1.49136.1.8.6 |
btst-volt-fro INTEGER .1.3.6.1.4.1.49136.1.8.7 |
btst-amp-fro INTEGER .1.3.6.1.4.1.49136.1.8.8 |
ALGPOWER-v2-MIB Technical Reference Overview
The ALGPOWER-v2-MIB SNMP MIB module published by Algcom defines 59 managed OID objects, including 49 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events.
Key OID Definitions in ALGPOWER-v2-MIB
.1.3.6.1.4.1.49136.1.1.1Numeric value of instantaneous output voltage from the source in tenths of a volt. To get the value actual in volt should be divided by 10. Example: Read value 241, actual value 24.1V.
.1.3.6.1.4.1.49136.1.1.2Numeric value of current output of converter AC/DC. Real value reading in milli ampere. Example: Read value 1087, Actual value 1.087 milli ampere or 1.087A. If the output is '0' the AC/DC is off and the output for the equipments is provide from batteries
.1.3.6.1.4.1.49136.1.1.3OID not used.
.1.3.6.1.4.1.49136.1.1.4OID not used.
.1.3.6.1.4.1.49136.1.2.1Numeric value of instantaneous voltage of battery bank. To get the actual value in volt must be divided by 10. Example: Read value 240, actual value 24.0V.
.1.3.6.1.4.1.49136.1.2.2Numeric value of current in Battery bank. Real value reading in milli ampere. If the value is negative the Battery bank is provide energy for the output. If the value is positive the Battery bank is under charger Example: Read value -2230, Actual value 2,230 ampere and the battery bank is provide this current. Read value 3000, Actual value 3.000 milli ampere and the battery bank is absorve this current.
.1.3.6.1.4.1.49136.1.2.3Show the status of battery charger: 0 - The battery is not connected in DC UPS; 1 - The battery is voltage incompatible with DC UPS; 2 - The DC UPS is in nobreak mode; 3 - The charger of Battery is in Bulk stage; 4 - The charger of Battery is Absorption stage; 5 - The charger of Battery is Float stage; 6 - The Battery will be disconnected in 30s due to low voltage and the DC-UPS output will be turned off. 7 - The Battery is under test
.1.3.6.1.4.1.49136.1.3.1Shows the operation mode of DC-UPS: 0 - The DC-UPS output is provide by AC energy. 1 - The DC-UPS output is provide by Battery
.1.3.6.1.4.1.49136.1.3.2Alarm that alert about AC outages in the last 10 minutes: 0 - DC-UPS in normal operation. 1 - Occur a AC fail in the last 10 minutes.
.1.3.6.1.4.1.49136.1.3.3Show the status of charging Battery: 1 - The battery is on charging. 0 - The battery is on discharging.
.1.3.6.1.4.1.49136.1.3.4Show the status of discharging Battery: 1 - The battery is on discharging. 0 - The battery is on charging.
.1.3.6.1.4.1.49136.1.3.5Alarm that alert about overtemperature of DC-UPS 1 - The DC-UPS is in condition of overtemperature. 0 - The DC-UPS is in normal condition.
.1.3.6.1.4.1.49136.1.3.6Alarm that alert about overload of DC-UPS 1 - The DC-UPS is in condition of overload. 0 - The DC-UPS is in normal condition.
.1.3.6.1.4.1.49136.1.3.7Alarm that alert about fail in internal FAN A 1 - Internal FAN with fail. 0 - Internal FAN ok
.1.3.6.1.4.1.49136.1.3.8Alarm that alert about fail in internal FAN B 1 - Internal FAN with fail. 0 - Internal FAN ok
.1.3.6.1.4.1.49136.1.3.9OID not used.
.1.3.6.1.4.1.49136.1.3.10OID not used.
.1.3.6.1.4.1.49136.1.3.11System Up time in hours
.1.3.6.1.4.1.49136.1.4.1Show the internal temperature of power supply. Uses the unit degree Celsius. Example Read value: 25, temperature is 25degC.
.1.3.6.1.4.1.49136.1.4.2Show the temperature of external sensor (cable that comes with power supply). Uses the unit degree Celsius. Example Read value: 25, temperature is 25degC.
.1.3.6.1.4.1.49136.1.4.3Show the temperature of sensor in the heatsink of power supply use the unit degree Celsius. Example Read value: 25, temperature is 25degC.
.1.3.6.1.4.1.49136.1.5.1Alarm indicating the action of watchdog 1 programmed in the last 10 minutes. The watchdog acts on the output by turning it off when not receive response from IP ping command configured. 1 - The watchdog 1 acted on the output the last 10 minutes. 0 - The Watchdog 1 has not acted in the last 10 minutes.
.1.3.6.1.4.1.49136.1.5.2Alarm indicating the action of watchdog 2 programmed in the last 10 minutes. The watchdog acts on the output by turning it off when not receive response from IP ping command configured. 1 - The watchdog 2 acted on the output the last 10 minutes. 0 - The Watchdog 2 has not acted in the last 10 minutes.
.1.3.6.1.4.1.49136.1.5.3Alarm indicating the action of watchdog 3 programmed in the last 10 minutes. The watchdog acts on the output by turning it off when not receive response from IP ping command configured. 1 - The watchdog 3 acted on the output the last 10 minutes. 0 - The Watchdog 3 has not acted in the last 10 minutes.