ALGPOWER-v2-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ALGPOWER-v2-MIB.

59
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

59 total
Object Name
algcom
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136
RFC1213-MIB
Unknown
.1.3.6.1.4.1.49136
upsObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1
output
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.1
outputVoltagero
INTEGER
.1.3.6.1.4.1.49136.1.1.1
outputCurrentro
INTEGER
.1.3.6.1.4.1.49136.1.1.2
oidNotUsed0ro
INTEGER
.1.3.6.1.4.1.49136.1.1.3
oidNotUsed1ro
INTEGER
.1.3.6.1.4.1.49136.1.1.4
battery
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.2
batteryVoltagero
INTEGER
.1.3.6.1.4.1.49136.1.2.1
batteryCurrentro
INTEGER
.1.3.6.1.4.1.49136.1.2.2
chargerStatusro
INTEGER
.1.3.6.1.4.1.49136.1.2.3
input
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.3
alarmOnBatteryro
INTEGER
.1.3.6.1.4.1.49136.1.3.1
acFailro
INTEGER
.1.3.6.1.4.1.49136.1.3.2
batteryChargingro
INTEGER
.1.3.6.1.4.1.49136.1.3.3
batteryDischargingro
INTEGER
.1.3.6.1.4.1.49136.1.3.4
overheatro
INTEGER
.1.3.6.1.4.1.49136.1.3.5
overloadro
INTEGER
.1.3.6.1.4.1.49136.1.3.6
fanAfailro
INTEGER
.1.3.6.1.4.1.49136.1.3.7
fanBfailro
INTEGER
.1.3.6.1.4.1.49136.1.3.8
oidNotUsed2ro
INTEGER
.1.3.6.1.4.1.49136.1.3.9
oidNotUsed3ro
INTEGER
.1.3.6.1.4.1.49136.1.3.10
upTimero
INTEGER
.1.3.6.1.4.1.49136.1.3.11
temperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.4
innerTemperaturero
INTEGER
.1.3.6.1.4.1.49136.1.4.1
outerTemperaturero
INTEGER
.1.3.6.1.4.1.49136.1.4.2
heatSinkTemperaturero
INTEGER
.1.3.6.1.4.1.49136.1.4.3
watchdog
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.5
watchdogPing1ro
INTEGER
.1.3.6.1.4.1.49136.1.5.1
watchdogPing2ro
INTEGER
.1.3.6.1.4.1.49136.1.5.2
watchdogPing3ro
INTEGER
.1.3.6.1.4.1.49136.1.5.3
watchdogPing4ro
INTEGER
.1.3.6.1.4.1.49136.1.5.4
watchdogPing5ro
INTEGER
.1.3.6.1.4.1.49136.1.5.5
watchdogPing6ro
INTEGER
.1.3.6.1.4.1.49136.1.5.6
watchdogPing7ro
INTEGER
.1.3.6.1.4.1.49136.1.5.7
watchdogPing8ro
INTEGER
.1.3.6.1.4.1.49136.1.5.8
watchdogPing9ro
INTEGER
.1.3.6.1.4.1.49136.1.5.9
watchdogPing10ro
INTEGER
.1.3.6.1.4.1.49136.1.5.10
supply
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.6
supplyVoltagero
INTEGER
.1.3.6.1.4.1.49136.1.6.1
installation
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.7
popNamero
DisplayString
.1.3.6.1.4.1.49136.1.7.1
facilityAddrro
DisplayString
.1.3.6.1.4.1.49136.1.7.2
facilityCityro
DisplayString
.1.3.6.1.4.1.49136.1.7.3
instDatero
DisplayString
.1.3.6.1.4.1.49136.1.7.4
batCapacityro
INTEGER
.1.3.6.1.4.1.49136.1.7.5
batBrandro
DisplayString
.1.3.6.1.4.1.49136.1.7.6
batInstDatero
DisplayString
.1.3.6.1.4.1.49136.1.7.7
respPersro
DisplayString
.1.3.6.1.4.1.49136.1.7.8
bat-tst
OBJECT IDENTIFIER
.1.3.6.1.4.1.49136.1.8
btst-datero
DisplayString
.1.3.6.1.4.1.49136.1.8.1
btst-statusro
INTEGER
.1.3.6.1.4.1.49136.1.8.2
btst-durationro
INTEGER
.1.3.6.1.4.1.49136.1.8.3
btst-elapsedro
INTEGER
.1.3.6.1.4.1.49136.1.8.4
btst-volt-iro
INTEGER
.1.3.6.1.4.1.49136.1.8.5
btst-amp-iro
INTEGER
.1.3.6.1.4.1.49136.1.8.6
btst-volt-fro
INTEGER
.1.3.6.1.4.1.49136.1.8.7
btst-amp-fro
INTEGER
.1.3.6.1.4.1.49136.1.8.8

ALGPOWER-v2-MIB Technical Reference Overview

The ALGPOWER-v2-MIB SNMP MIB module published by Algcom defines 59 managed OID objects, including 49 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events.

Key OID Definitions in ALGPOWER-v2-MIB

outputVoltageINTEGERread-only
.1.3.6.1.4.1.49136.1.1.1

Numeric value of instantaneous output voltage from the source in tenths of a volt. To get the value actual in volt should be divided by 10. Example: Read value 241, actual value 24.1V.

outputCurrentINTEGERread-only
.1.3.6.1.4.1.49136.1.1.2

Numeric value of current output of converter AC/DC. Real value reading in milli ampere. Example: Read value 1087, Actual value 1.087 milli ampere or 1.087A. If the output is '0' the AC/DC is off and the output for the equipments is provide from batteries

oidNotUsed0INTEGERread-only
.1.3.6.1.4.1.49136.1.1.3

OID not used.

oidNotUsed1INTEGERread-only
.1.3.6.1.4.1.49136.1.1.4

OID not used.

batteryVoltageINTEGERread-only
.1.3.6.1.4.1.49136.1.2.1

Numeric value of instantaneous voltage of battery bank. To get the actual value in volt must be divided by 10. Example: Read value 240, actual value 24.0V.

batteryCurrentINTEGERread-only
.1.3.6.1.4.1.49136.1.2.2

Numeric value of current in Battery bank. Real value reading in milli ampere. If the value is negative the Battery bank is provide energy for the output. If the value is positive the Battery bank is under charger Example: Read value -2230, Actual value 2,230 ampere and the battery bank is provide this current. Read value 3000, Actual value 3.000 milli ampere and the battery bank is absorve this current.

chargerStatusINTEGERread-only
.1.3.6.1.4.1.49136.1.2.3

Show the status of battery charger: 0 - The battery is not connected in DC UPS; 1 - The battery is voltage incompatible with DC UPS; 2 - The DC UPS is in nobreak mode; 3 - The charger of Battery is in Bulk stage; 4 - The charger of Battery is Absorption stage; 5 - The charger of Battery is Float stage; 6 - The Battery will be disconnected in 30s due to low voltage and the DC-UPS output will be turned off. 7 - The Battery is under test

alarmOnBatteryINTEGERread-only
.1.3.6.1.4.1.49136.1.3.1

Shows the operation mode of DC-UPS: 0 - The DC-UPS output is provide by AC energy. 1 - The DC-UPS output is provide by Battery

acFailINTEGERread-only
.1.3.6.1.4.1.49136.1.3.2

Alarm that alert about AC outages in the last 10 minutes: 0 - DC-UPS in normal operation. 1 - Occur a AC fail in the last 10 minutes.

batteryChargingINTEGERread-only
.1.3.6.1.4.1.49136.1.3.3

Show the status of charging Battery: 1 - The battery is on charging. 0 - The battery is on discharging.

batteryDischargingINTEGERread-only
.1.3.6.1.4.1.49136.1.3.4

Show the status of discharging Battery: 1 - The battery is on discharging. 0 - The battery is on charging.

overheatINTEGERread-only
.1.3.6.1.4.1.49136.1.3.5

Alarm that alert about overtemperature of DC-UPS 1 - The DC-UPS is in condition of overtemperature. 0 - The DC-UPS is in normal condition.

overloadINTEGERread-only
.1.3.6.1.4.1.49136.1.3.6

Alarm that alert about overload of DC-UPS 1 - The DC-UPS is in condition of overload. 0 - The DC-UPS is in normal condition.

fanAfailINTEGERread-only
.1.3.6.1.4.1.49136.1.3.7

Alarm that alert about fail in internal FAN A 1 - Internal FAN with fail. 0 - Internal FAN ok

fanBfailINTEGERread-only
.1.3.6.1.4.1.49136.1.3.8

Alarm that alert about fail in internal FAN B 1 - Internal FAN with fail. 0 - Internal FAN ok

oidNotUsed2INTEGERread-only
.1.3.6.1.4.1.49136.1.3.9

OID not used.

oidNotUsed3INTEGERread-only
.1.3.6.1.4.1.49136.1.3.10

OID not used.

upTimeINTEGERread-only
.1.3.6.1.4.1.49136.1.3.11

System Up time in hours

innerTemperatureINTEGERread-only
.1.3.6.1.4.1.49136.1.4.1

Show the internal temperature of power supply. Uses the unit degree Celsius. Example Read value: 25, temperature is 25degC.

outerTemperatureINTEGERread-only
.1.3.6.1.4.1.49136.1.4.2

Show the temperature of external sensor (cable that comes with power supply). Uses the unit degree Celsius. Example Read value: 25, temperature is 25degC.

heatSinkTemperatureINTEGERread-only
.1.3.6.1.4.1.49136.1.4.3

Show the temperature of sensor in the heatsink of power supply use the unit degree Celsius. Example Read value: 25, temperature is 25degC.

watchdogPing1INTEGERread-only
.1.3.6.1.4.1.49136.1.5.1

Alarm indicating the action of watchdog 1 programmed in the last 10 minutes. The watchdog acts on the output by turning it off when not receive response from IP ping command configured. 1 - The watchdog 1 acted on the output the last 10 minutes. 0 - The Watchdog 1 has not acted in the last 10 minutes.

watchdogPing2INTEGERread-only
.1.3.6.1.4.1.49136.1.5.2

Alarm indicating the action of watchdog 2 programmed in the last 10 minutes. The watchdog acts on the output by turning it off when not receive response from IP ping command configured. 1 - The watchdog 2 acted on the output the last 10 minutes. 0 - The Watchdog 2 has not acted in the last 10 minutes.

watchdogPing3INTEGERread-only
.1.3.6.1.4.1.49136.1.5.3

Alarm indicating the action of watchdog 3 programmed in the last 10 minutes. The watchdog acts on the output by turning it off when not receive response from IP ping command configured. 1 - The watchdog 3 acted on the output the last 10 minutes. 0 - The Watchdog 3 has not acted in the last 10 minutes.